Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Similar documents
Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

A low-cost, economical solution for distribution feeder protection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Advanced distribution feeder solution with integrated protection, monitoring, and control

High-speed transformer differential protection for up to five terminals

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Lightweight and flexible recloser control for single-phase applications

2 ms arc-flash protection and feeder relay in one platform

Built for speed, security, and simplicity

SEL-421 Data Sheet. Protection, Automation, and Control System With Sampled Values. Major Features and Benefits

Protect induction and synchronous motors with one relay.

2 ms arc-flash protection and feeder relay in one platform

SEL Time-Domain Link (TiDL ) Technology

Maximize process uptime with the SEL-patented motor thermal model.

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

SEL-421-4, -5 Protection and Automation System

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SEL-311C-1 Transmission Protection System

SEL-487B Bus Differential Relay

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

Protect induction and synchronous motors with one relay

NERC PRC-002 Recording Solutions

Comprehensive protection for large, medium, and small generators

Powerful and flexible recloser control for many popular reclosers

Real-time visualization for detecting and solving power system challenges

SEL Protection, Automation, and Bay Control System

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line differential protection RED670 Relion 670 series

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

SEL-401 Data Sheet. Protection, Automation, and Control Merging Unit. Major Features and Benefits

SEL Real-Time Automation Controller (RTAC)

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

One relay for safety and process continuity

Designed, built, and tested for troublefree operation in extreme conditions

Bus Bar Protection Relay B-PRO 4000

SOLUTIONS FOR AN EVOLVING WORLD RFL GARD Protective Relay & Communications System RFL GARD SFPLC 1

Integrated Communications Optical Network. Guarantee fast and dependable operation for power protection and mission-critical

SEL-321 Data Sheet. Phase and Ground Distance Relay, Directional Overcurrent Relay, Fault Locator

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

2008 Many Changes in IEEE C37.2. IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations

SEL-351A Protection System Data Sheet

Transformer Protection Relay

GE Multilin 350 Feeder Protection Relay Specifications

DRTS 33. The new generation of advanced three phase relay test set

IDM DATA ACQUISITION SYSTEM

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

GRID/PRSHT/MU320/EN/1.2014/GBR/1894 ALSTOM All rights reserved.

SEL-2414 Transformer Monitor

SEL-351-5, -6, -7 Protection System Data Sheet

SEL University. Power Through Knowledge. Dr. Héctor J. Altuve Ferrer Dean of SEL University

SEL-2030 Communications Processor

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Automation Services and Solutions

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

SEL-351RS Kestrel Single-Phase Recloser Control Major Features and Benefits

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

UR Universal Relay Series

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

Power Systems Communications Implementation of IEC61850 in a Substation Environment

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

Merging unit ENMU. Manual

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

PG&E 500 kv Protection Standard Design and Development

Power System Monitoring Recorder

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Digital Substation Overview of Technology, Industry

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

SEL-351S Protection System Data Sheet

SEL-587Z High-Impedance Differential and Overcurrent Relay

SEL-400 Series TiDL Quick-Start Guide

ABB Inc. Substation Automation and Protection Division Coral Springs, FL Allentown, PA. Multi-Zoned Distance

Designing a new IEC substation architecture

SEL-2440 Discrete Programmable Automation Controller

Perfect protection smallest space

2 NOVATECH. This page is intentionally left blank.

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

SEL-2411P Pump Automation Controller Data Sheet

Transcription:

Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines. Comprehensive communications protocols and advanced automation functions allow customization for different applications. Two-breaker bay control provides protection flexibility in one device. SEL Time-Domain Link (TiDL ) and Sampled Values (SV) technologies transform the way you modernize your substation.

Functional Overview Bus Line 1 50BF 50 51 25 79 50BF 50 51 SEL-2800 21 81 O U 67 68 27 59 ANSI Numbers/Acronyms and Functions 21 Phase and Ground Distance 25 Synchronism Check 27 Undervoltage 2 Directional Power 50 Overcurrent 50BF Dual Breaker Failure Overcurrent 51 Time-Overcurrent 59 Overvoltage 67 Directional Overcurrent 68 Out-of-Step Block/Trip 79 Single-/Three-Pole Frequency 81 (O,U) Over-/Underfrequency 85 RIO SEL Mirrored Bits Communications DFR Event Reports ENV SEL-2600* HMI Operator Interface LGC Expanded SELogic Control Equations MET High-Accuracy Metering PMU Synchrophasors SER Sequential Events Recorder Bus 1 ENV SEL-2600 4 EIA-22 2 Ethernet 1 * -4/-5 2 Ethernet Ethernet Station Bus Process Bus -7 2 1 IRIG-B Additional Functions BRM LDE LOC SBM SV TiDL Breaker Wear Monitor Load Encroachment Fault Locator Station Battery Monitor IEC 61850-9-2 Sampled Values Technology* Time-Domain Link Technology* 1 Copper or fiber-optic *Optional feature

Key Features Distance and Directional Overcurrent Protection The Protection, Automation, and Control System protects critical transmission lines with high-speed quadrilateral, mho distance, and directional elements. Implement optional subcycle distance elements and series compensation logic to reduce operating times and improve system stability. Comprehensive Monitoring Incorporate IEEE C7.118 synchrophasor measurements into wide-area protection and control systems. High-accuracy time correlation improves event report analysis. Advanced Communications Use serial or Ethernet communications to improve station integration. A variety of protocols are available, including Mirrored Bits communications, DNP LAN/WAN, Modbus, the Simple Network Time Protocol (SNTP), the Parallel Redundancy Protocol (PRP), the IEEE 1588 Precision Time Protocol Version 2 (PTPv2), and IEC 61850 Edition 2. Digital Secondary System Technologies Modernize your substation by applying SEL TiDL technology or SEL SV technology. Both of these digital secondary system solutions replace copper wires with fiber-optic cables to increase safety, reduce costs associated with using copper wires, and limit the impact of electromagnetic interference. TiDL is a simple and secure digital secondary system solution that is easy to implement, with no external time source or network engineering required. Apply the TiDL-enabled -4/-5 in the control house with the SEL-2240 Axion TiDL node in the yard, which provides remote I/O, digitizes analog signals, and sends the signals over fiber-optic cables to the relay. SEL SV is the only digital secondary system solution in the world that combines protection in the merging unit with the flexibility of IEC 61850-9-2 to increase power system reliability. Apply the -7 with SEL SV technology to publish or receive IEC 61850-9-2 SV data.

Product Overview EIA-22 front serial port is quick and convenient for system setup and local access. Front-panel LEDs indicate custom alarms and provide fast and simple information to assist dispatchers and line crews with rapid power restoration. Front-panel display allows operators to control and view the status of disconnects and breakers. Programmable operator pushbuttons with userconfigurable labels allow front-panel customization. User-selectable mimic screens show the system configuration in one-line diagram format. Easy-to-use keypad aids simple navigation.

Communications protocols include FTP, Telnet, synchrophasors, DNP LAN/WAN, PRP, IEEE 1588 PTPv2,** and IEC 61850 Edition 2.* High-current interrupting output contacts increase contact robustness and reliability. Use one front and three rear EIA-22 ports for Mirrored Bits communications, DNP, SCADA, and engineering access. Six current and six voltage analog inputs support complete bay control and protection as well as two-breaker bay applications. Choose from a vertical or horizontal, panel-mount or rack-mount chassis and different size options. Choose from power supply options such as 24 48 Vdc; 48 125 Vdc or 110 120 Vac; or 125 250 Vdc or 110 240 Vac. *Optional feature **For PTPv2 implementation, Ports 5A and 5B must be ordered as an option.

Applications Reliable Distance Protection The has reliable distance protection with five zones of phase and ground (mho and quadrilateral) distance elements. Coupling capacitor voltage transformer (CCVT) transient overreach logic optimizes performance and enhances Zone 1 distance element security. The Best Choice Ground Directional Element logic eliminates the need for multiple settings. In addition, with full pilot scheme settings, it is easy to integrate the into your existing distance protection schemes. Choose from POTT, DCUB, PUTT, DCB, and DTT schemes. Zone / Blocking Zone 5/ Coordination Zone 1/Direct Trip Ia, Ib, Ic POTT, DCB,... Zone 2/Permissive Zone Zone 4/Time Delay System Backup Secure, High-Speed Tripping Optional high-speed elements use a combination of half-cycle filtered inputs with superimposed components to achieve high-speed operation while maintaining security for out-of-zone faults. Use an with standardspeed elements where operation times of under 1.5 cycles are sufficient, with the capability to upgrade to subcycle operation times if system conditions change. Apply Mirrored Bits communications between relays using fiber-optic transceivers for relay-to-relay signal transmission in to 6 ms. CCVT transient detection, fast and secure lossof-potential (LOP) blocking, and loadencroachment logic provide additional security in all models. Time in Cycles Time in Cycles 1.50 1.25 1.0 0.75 0.50 0.25 1.50 1.25 1.0 0.75 0.50 0.25 High-Speed Elements 20% 40% 60% 80% Fault Location as Percent of Reach Setting High-Speed Elements 20% 40% 60% 80% Fault Location as Percent of Reach Setting Single Phase-to-Ground Faults SIR = 10.0 SIR = 1.0 SIR = 0.1 SIR = 10.0 SIR = 1.0 SIR = 0.1 Time in Cycles 1.50 1.25 1.0 0.75 0.50 0.25 Phase-to-Phase Faults Time in Cycles 1.50 1.25 1.0 0.75 0.50 0.25 Standard-Speed Elements 20% 40% 60% 80% Fault Location as Percent of Reach Setting Standard-Speed Elements 20% 40% 60% 80% Fault Location as Percent of Reach Setting SIR = 10.0 SIR = 1.0 SIR = 0.1 SIR = 10.0 SIR = 1.0 SIR = 0.1 High-Speed Elements Three-Phase Faults Standard-Speed Elements 1.50 1.50 Time in Cycles 1.25 1.0 0.75 0.50 0.25 SIR = 1.0, 10.0 SIR = 0.1 Time in Cycles 1.25 1.0 0.75 0.50 0.25 SIR = 10.0 SIR = 1.0 SIR = 0.1 20% 40% 60% 80% 20% 40% 60% 80% Fault Location as Percent of Reach Setting Fault Location as Percent of Reach Setting

Dual CT Applications The works with ring-bus, breaker-and-a-half, or other two-breaker schemes. You can combine currents within the relay from two sets of CTs for protection functions while keeping them separately available for monitoring and station integration applications. Out-of-Step Blocking and Tripping During power swings, the relay automatically selects either out-of-step blocking or tripping. Out-of-step blocking enhances your security by blocking distance elements during stable power swing conditions. During unstable power swing conditions, the implements out-ofstep tripping to maintain generation load balance. Bay Control, Reclosing, and Breaker Failure Detection The provides complete bay control, reclosing, and breaker failure protection, increasing your flexibility for different station configurations. For double-breaker arrangements, you can monitor the current for each breaker separately or combine the currents for protection purposes. You can also monitor the circuit breaker performance, including average and last tripping times, motor run times, and contact interrupting duty. Underfrequency Load Shedding Operate six levels of frequency elements as either an underfrequency or an overfrequency element. The frequency elements are suited for applications such as underfrequency load shedding and restoration control systems.

High-Speed Breaker Failure for Two Breakers The applies fast open-phase detection logic to detect an open phase in less than one cycle, leading to shorter breaker failure margin times. By combining high-speed tripping with shorter breaker failure margin times, the helps increase line loading while maintaining stability. Power Initial System Recovery System Equal Areas Faulted System Critical Clearing Time Angle Total Backup Clearing = 10 Cycles (60 Hz) Breaker Time = 2 Cycles Breaker Failure Margin = 4 Cycles Breaker Backup = 2 Cycles POTT Time = 6 ms Relay Op. Time = ¾ Cycle DTT Tx/Rx = 6 ms (omit for local breaker) Lockout = 8 ms (omit if high-speed outputs used) Secure Protection Under High Loads Prevent operation of the phase distance elements under high-load conditions with built-in load-encroachment logic. This feature permits the load to enter a predefined area of the phase distance characteristic without causing a trip. X Positive- Sequence Line Angle Load-In Region Load-Out Region R Area Where Phase Mho Elements Are Blocked Load-encroachment characteristic.

Synchrophasors To significantly improve your system s performance, SEL offers complete synchrophasor solutions, including hardware, communications, viewing and analysis software, data collection, and data archiving. The provides real-time system state measurement with timesynchronized voltages and currents in the IEEE C7.118 standard format. In addition, SEL-5078-2 synchrowave Central Software or third-party software allows you to view and analyze system phase angles, load oscillations, voltage profiles, and other critical system information. High-Accuracy Time Stamping The time-tags binary COMTRADE event reports with real-time accuracy of better than 10 µs. View system state information at the time of faults or with timed triggers, across the entire system. Use system state information to validate system models as well as to improve transfer limits and system stability. SNTP is capable of 5 ms accuracy over Ethernet and makes a good backup to more accurate IRIG-B or PTP time synchronization. Simplified System Setup and Analysis With acselerator QuickSet SEL-500 Software, you can develop relay settings offline, program SELogic control equations, and analyze post-fault event reports. Enhanced Automation The provides enhanced automation features, including 2 programmable elements for local control, remote control, protection latching, and automation latching. synchrowave Central Software provides visualization and analysis of power system operating conditions. Custom Applications With SELogic Control Equations The enables math and logic combinations of analog and digital values. You can adapt system control based on prefault conditions, scale analog values, and latch momentary inputs for SCADA retrieval. Digital Fault Recording Combine relaying reliability with true digital fault recorder (DFR) functionality. The Relay s high-speed sampling (8 khz) and COMTRADE output provide advanced oscillography. Use the QuickSet graphical user interface for harmonic analysis and easy report generation.

TiDL Technology In a TiDL solution, Axion TiDL nodes are placed in the yard close to the primary equipment to digitize discrete I/O signals and analog data and then transport them over a fiber-optic cable to the TiDL-enabled in the control house. This innovative technology uses point-to-point connections and a nonroutable protocol, providing a simple and secure solution. Because it does not require an external time source or Ethernet switches, it is easy to implement with no network engineering required. TiDL combines the proven protection of the SEL-400 series relays with the modularity of the Axion, reducing training requirements and providing a scalable and flexible solution. It also provides built-in time synchronization and synchronous sampling, ensuring protection is available in the relay regardless of whether or not an external time signal is available. Substation Yard Fiber-Optic Cable SEL-2240 Axion SEL-2240 Axion SEL-2240 Axion Control House 1 SEL-2240 SEL-2240 1 Axion Axion

-4/-5 With TiDL Technology LEDs indicate a valid configuration and successful commissioning. LEDs indicate the connection status to a remote Axion TiDL node on a per-port basis. 4U chassis with mounting options (vertical or horizontal; panel or rack) accommodates your application needs. Eight 100 Mbps fiber-optic ports allow the TiDL-enabled relay to connect with eight remote Axion TiDL nodes and to receive remote analog and digital data. Commission button usage prompts the relay to communicate with the Axion TiDL nodes.

SEL SV Technology In an SEL SV solution, the -7 Merging Unit (publisher) digitizes analog signals from primary equipment and then transmits the signals to an -7 Relay (subscriber) in the control house via a fiber-based Ethernet network. The system uses precise time synchronization via IRIG-B or PTP. The -7 Merging Unit is the only standalone merging unit in the world with complete line protection built in. This allows you to have the protection right next to the primary equipment for increased speed and reliability and to easily duplicate the SV data streams for redundant protection. The -7 Relay offers the traditional protection available in the -5 and can also receive SV data. Because all SEL SV devices are fully compliant with IEC 61850-9-2 and the UCA 61850-9-2LE guideline, they can be used with primary equipment that generates similar SV streams or with other manufacturers SV-compliant units. SEL SV technology allows you to create a robust and flexible Ethernet-based point-to-multipoint network using tools such as software-defined networks or VLANs to fit your application needs. Substation Yard Control House Merging Unit Relay SV Relay Process Bus SV, GOOSE, PTP SEL-2740M 1 SEL-401 Merging Unit SV Merging Unit 1 Ethernet Switch SEL-2488 GPS Clock Fiber-Optic Cable

-7 Merging Unit Chassis options (for up to three I/O boards) and mounting options accommodate hardware needs. Select fiber-optic, copper, or mixed Ethernet with separate ports for SV data and engineering access. Six current and six voltage analog inputs support signal digitization and local protection schemes. Choose from power supply options such as 48 125 Vdc or 110 120 Vac, or 125 250 Vdc or 110 240 Vac. -7 Relay The 4U chassis has various mounting options to accommodate hardware needs. Select fiber-optic, copper, or mixed Ethernet with separate ports for SV data and engineering access. Choose from power supply options such as 48 125 Vdc or 110 120 Vac, or 125 250 Vdc or 110 240 Vac.

Accessibility and Communications Built-In Web Server Access basic information on a standard Ethernet network with the builtin web server. From there you can view relay status, Sequential Events Recorder (SER) data, metering information, and settings. For increased security, web server access requires a relay password and the information is limited to a read-only view. Ethernet-Based Communications The Ethernet ports on the enable you to communicate using a variety of protocols, including FTP, DNP, MMS, PTPv2, and IEC 61850 Edition 2. By using failover, switched mode, or PRP, you can increase your system s reliability. For PTPv2 implementation, Ports 5A and 5B must be ordered as an option in the -4/-5. Engineering Access SEL-451 SEL-2488 GPS Clock SEL-270M Ethernet Switch Wide-Area Network SEL-487B SEL-50 SEL-451 Mirrored Bits Communications Mirrored Bits communications is a field-proven technology that provides simple and powerful bidirectional digital communications between devices. Mirrored Bits communications can transmit/receive information between upstream relays and downstream recloser controls to enhance coordination and generate faster tripping for downstream faults. 52 MIRRORED BITS Communications Digital, Analog, or Virtual Terminal 52

Specifications General AC Current Inputs (6 total) AC Voltage Inputs (6 total) Serial Ethernet 5 A nominal 1 A nominal 00 V L-N continuous, 600 Vac for 10 seconds 1 front-panel and rear-panel EIA-22 serial ports 00 57,600 bps Communications protocols include FTP, Telnet, synchrophasors, DNP LAN/WAN, PRP, PTPv2, and IEC 61850 Edition 2 (optional). Choose from the following port options: Two 10/100BASE-T twisted-pair network ports Two 100BASE-FX fiber-optic network ports One 10/100BASE-T twisted-pair network port and one 100BASE-FX fiber-optic network port TiDL Ports Fiber-optic ports: 8 Range: ~2 km Data rate: 100 Mbps SV Ports Precise-Time Input Synchrophasors Processing Power Supply Operating Temperature Choose from the following communications port options: Four 10/100BASE-T twisted-pair network ports Four 100BASE-FX fiber-optic network ports Two 10/100BASE-T twisted-pair network ports and two 100BASE-FX fiber-optic network ports Subscriber: As many as 4 SV data streams Publisher: As many as 7 SV data streams Data rate: 80 samples per cycle Demodulated IRIG-B time input and PTPv2 IEEE C7.118 Standard Up to 60 messages per second AC voltage and current inputs: 8,000 samples per second Protection and control processing: 8 times per power system cycle -4/-5 24 48 Vdc 48 125 Vdc or 110 120 Vac 125 250 Vdc or 110 240 Vac -7 48 125 Vdc or 110 120 Vac 125 250 Vdc or 110 240 Vac 40 C to +85 C ( 40 to +185 F) Note: LCD contrast is impaired for temperatures below 20 C ( 4 F) and above +70 C (+158 F).

Making Electric Power Safer, More Reliable, and More Economical Tel: +1.509.2.1890 Email: info@selinc.com Web: www.selinc.com 2017 by Schweitzer Engineering Laboratories, Inc. PF00009 20171211