Perle 10GT Media Converters

Similar documents
Perle 10GT Media Converter Modules

Perle S-10GRT-SFP Media Converter Installation Guide

Perle 10G Media Converter Modules

Perle 10G Media Converter Modules

Perle Cx-10GR-STS Media Converter Modules

Perle MCR200 Installation Guide

Perle Gigabit Media Converters

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

Perle Protocol Transparent Media Converter Modules

Perle PoE/PoE+ 10/100 Ethernet Media Converters

Perle SMI Media Converter Installation Guide

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

Perle Advanced Powered Ethernet Extenders Installation Guide

Perle 10/100/1000 Ethernet Extender Modules. 10/100 10/100/1000 (Gigabit)

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

24-Port Gigabit Ethernet Switches

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

GSW User Manual. 4-Port TP + 1-Port SFP Gigabit Ethernet Switch. Ver

Preface. Manual Revisions. Trademarks

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

pakedgedevice&software inc.

FCC Certifications. CE Mark Warning

FCC Certifications. CE Mark Warning

10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

ex-s1110-xt Gigabit Ethernet Extenders

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

HES-3106-PLUS SERIES

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Owner s Manual. Media Converters Models: N SC & N ST

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

LNX-0702G-SFP Series

Ethernet 10Base-T Hub EH-500 EH-800A EH Rev. 3.0

5/8 Port Gigabit Ethernet Switch

10/100Base-TX to 100Base-FX Media Converter

LevelOne. User s Guide EHU-0507T EHU-0507TB EHU-0807T EHU-0907TB. 5/8/9 Port PalmCon 10M HUB

D-Link Switch User Manual. Table of Contents

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

LevelOne FSW PoE Fast Ethernet Switch User Manual

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

MDI/MDIX) FEP-32005T-2

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

FRG-3105 Series Residential Gateway

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE

IFS MC201-1P/1FS User Manual

GEU-0520 GEU QIG Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

IMC-21GA Quick Installation Guide

Gigabit Desktop. manual Models & Model shown: INT / UM

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

Gigabit Ethernet Media Converter

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

LNX-1002C-SFP Series

Rugged Industrial Media Converter

BiPAC 2073 R2. BiPAC 2074 R2

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

8-Port 10/100TX 802.3at PoE + 2-Port 10/100TX Desktop Switch FSD-1008HP. User s Manual

16-Port Chassis Media Converter System Manual

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

exp-s1110pe PoE+ Gigabit Ethernet Extenders

Transcription:

Perle 10GT Media Converters Installation Guide S-10GT-SFP S-10GT-XFPH Part#5500336-10(Rev B)

OverView This document contains instructions necessary for the installation and operation of the Perle S-10GT Standalone Media Converters. Each media converter contains one pluggable transceiver port that permits insertion of a SFP+ / XFP fiber module or SFP+ / XFP copper module and one integrated RJ-45 (copper) port. These media converter can use either Perle Systems or third party MSA compatible 10G XFP or SFP+ modules including support for the following standards: 10GBase-SR, 10GBase-LR, 10GBase-ER, 10GBase-LRM and 10GBase-ZR. The S-10GT supports one low power transceiver (SFP+), whereas the S-10GT-XFPH supports one high power (up to power level 4) transceiver (XFP). Model Port 1 Port 2 S-10GT-SFP SFP+ RJ-45 S-10GT-XFPH XFP RJ-45 Note: The S-10GT Media Converter can operate as a 1G Media Converter if a 1G fiber transceiver has been inserted into the SFP+ transceiver port. Visit Perle s web site for the most up to date Installation guides, models and specifications: http://www.perle.com/ Getting to know your S-10GT Media Converter Your S-10GT Media Converter consists of the following items: S-10GT chassis with one RJ-45 port and one transceiver port Grounding screws (for improved chassis grounding) Country specific power adapter Power cord strain relief clip Four rubber feet This guide Perle S-10GT Media Converter Installation Guide 2

Front and Rear Panel Components Front View Rear View Perle S-10GT Media Converter Installation Guide 3

Installation The default switch setting (all switches in the UP position) will work for most installations. These are the steps required to configure the Perle S-10GT standalone media converter: 1. Set the DIP switch settings. (optional) 2. Connect the grounding lug. (optional) 3. Connect the power cord strain relief clip. (optional) 4. Insert the fiber module. 5. Connect the fiber. 6. Connect the RJ-45 (copper cable). 7. Using the Perle supplied power adapter, plug the power cord into the power cord connector at the rear of the chassis. 8. Plug the other end of the power adapter into an appropriate power outlet. Note: The S-10GT Chassis should always be grounded for safe and proper operation. See S-10GT-SFP or S-10GT-XFPH Perle S-10GT Media Converter Installation Guide 4

DIP Switch Settings The DIP switches are accessible through the opening in the side of the enclosure. Note: Switch changes made when the product is powered up take effect immediately and will result in a link reset on both ports. Operating Mode (Switch 1) Switch Position Mode Up (default) Down Data Test Data: In Data mode, data will flow between the fiber connection and the copper port. Test: Test Mode is used to run diagnostics, enable loopback and for running the Built In Link Test. Note: The Operation Mode (Switch 1) affects the function of DIP Switch 2 and 3 when in Test Mode. Link Mode (Switch 2 Data Mode) Switch Position Mode Up (default) Down Smart Link Pass-Through Mode Standard Mode Smart Link Pass-Through: In this mode, the link state on one port connection is directly reflected through the media converter to the other port connection. If the link is lost on one of the connections, then the other link will be brought down by the media converter. Standard Mode: In this mode, the links can be brought up and down independently of each other. A loss of link on either connection can occur without affecting the other fiber connection Part#5500336-10(Rev B)

Test Function (Switch 2 Test Mode) Switch Position Up (default) Down Type Built In Link Test (BILT) Loopback Built In Link Test: Set Switch 2 to the UP position for the S-10GT media converter to initiate the Built In Link Test on port 1. These tests consist of the media converter generating test patterns to be sent out on port 1 to the remote media converter. If the remote media converter is also a compatible 10GBaseT media converter then the remote media converter will automatically be put into test mode. Note: The BILT can operate on 10G modules. This feature can also be used with Perle C-10GT or CM-10GT media converters. Loopback: If Switch 2 is down, the specified port will be forced into loopback mode (switch 3 determines the port number). Data received on the receiver (RX) will be looped back to the transmitter (TX) connection. This mode is not used in conjunction with BILT. It can be used when other data generation methods are used. Illustration of the Built In Link Test Local S-10GT Configuration Test Mode (Switch 1 Down) Test Function (Switch 2 Up) Remote-S-10GT Configuration All switches in the Up position Perle S-10GT Media Converter Installation Guide 6

Sequence of Events 1. The Local S-10GT sends the Remote S-10GT a signal to go into test mode. 2. The Remote S-10GT media converter turns on test mode. 3. Built In test data is sent from the Local S-10GT media converter to the Remote S-10GT media converter. 4. The Remote S-10GT media converter analyses the received test data and sends its own test data plus a diagnostic code back to the Local S-10GT media converter. 5. If the PWR LED on the Local S-10GT blinks red, this connection may require further testing. The PWR LED should flash green to indicate that there have been no errors in the last second. 6. The Built in Link Test continues to run until Switch 1 on the Local S-10GT media converter is set to Data mode. Fiber Fault Alert (Switch 3 Data Mode) Switch Position Up (default) Down Mode Enabled Disabled Enabled: If the media converter detects a loss of signal on the fiber port, the media converter notifies the link partner on that same port that an error condition exists by bringing down the link. Disabled: The media converter will not monitor for fiber fault. Illustration of the FFA feature Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Perle S-10GT Media Converter Installation Guide 7

Sequence of Events 1. Media Converter A loses fiber connection (RX). 2. Media Converter A notifies the remote Media Converter that there is a fault on the Link. 3. Media Converter B detects loss of fiber link on receiver RX. 4. Media Converter B turns off transmitter (TX). Port Selection (Switch 3 Test Mode) Switch Position Port Up (default) 1 Down 2 When loopback mode is selected (Switch 1 and Switch 2 down), this switch specifies which port to enable loopback mode on. This switch is not used for BILT test mode, since it only runs on port 1. Energy Efficient Ethernet (EEE) (Switch 4) Switch Position Up (default) Down Mode Enabled Disabled Enabled: When enabled, the media converter will auto negotiate this capability with the attached EEE compliant devices/servers. Disabled: The media converter will not auto negotiate this capability with the attached EEE compliant devices/servers. Perle S-10GT Media Converter Installation Guide 8

Operation Powering up the Perle Media Converter 1. Connect the Perle supplied power adapter to the media converter. 2. Turn on the power at the source. 3. Check that the PWR LED light is lit. Status LED The Perle 10GT Media converters have three status LEDs located on the front panel of the unit. PWR - Power/Test Green On: Power is on and the unit is in normal operation mode. Green blinking slowly: the unit is in test or loopback mode. Red blinking slowly while in Test mode: indicates an error within the last second. Red Solid: During power up: Hardware error detected. (See PWR Red LED Errors) Red Blinking quickly: Error detected. (See LK1/LK2 Errors) Perle S-10GT Media Converter Installation Guide 9

LK1- Port 1 Activity On: Fiber link present. Blinking quickly: Fiber link present and receiving data. Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through. Off: No fiber link present. LK2 Port 2 Activity On: Copper link present. Blinking quickly: Copper link present and receiving data. Blinking slowly: The copper link has been taken down as a result of Smart Link Pass-Through. Off: No copper link present. LK1 LK2 Error Codes LK1 LK2 Meaning Off Off Incompatible SFP+ or XFP Off On Power Budget exceeded XFP s requesting more power than specified port rating. On On Internal Error PWR-Red LED Errors LK1 LK2 Meaning Blinking n/a Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded Off Off Internal Hardware. Grounding the S-10-GT Chassis If your installation requires additional grounding follow this procedure. Grounding the chassis requires the following items: One grounding lug (not provided) One 18-12 AWG wire (not provided) Cross-head screwdriver (not provided) Perle S-10GT Media Converter Installation Guide 10

Note: For your safety, when installing this equipment, always ensure that the chassis ground connection is installed first and disconnected last. Attaching the Grounding Lug 1. Attach the grounding lug to one end of an 18-12 AWG wire. 2. Attach the grounding lug to the chassis and secure with the grounding screw(s). Attaching the Power Cord Strain Relief Clip 1. Feed the power cord through the opening in the power cord relief clip. 2. Attach the power cord relief clip to the chassis and secure with the provided screw. 3. Plug the power cord into the AC power connector at the rear of the chassis. 4. Plug the other end of the power cord into an appropriate power outlet. Perle S-10GT Media Converter Installation Guide 11

Module Temperature Protection Every S-10GT comes equipped with an internal fan to provide cooling to the unit. The fan will come on during power up and then turn off. It will only come on when the temperature inside the case becomes elevated. If the module is operating above its specified maximum operating temperature, the S-10GT will reduce the power to the module. The S-10GT will continue to monitor the operating temperature of the unit until the temperature is below the maximum operating temperature and then the S-10GT will return the module to normal operating. Perle S-10GT Media Converter Installation Guide 12

Troubleshooting General Ensure power is supplied to the media converter use of the Perle supplied power adapter is highly recommended. Ensure that the SFP+ or XFP module is inserted into the transceiver port. Ensure that the copper cabling (RJ-45) meets Ethernet copper cabling requirements. See Copper Cable Requirements in this guide. No connectivity If unable to get full connectivity with all DIP switches in the UP position, these procedures can be used for troubleshooting. Built In Link Test Choose one side of the link to generate the test data (master side) and one side to receive and analyse the test data (slave side). 1. Set Switch 1 down and Switch 2 to the Up position (Built In Link Test) on the master side. 2. The master side automatically sends test data to the slave side. 3. The slave side analyses the received test data and sends its own test data plus a diagnostic code back to the master side. 4. If the PWR LED on the master side blinks red then this connection may require further testing. 5. If the PWR LED on the master side blinks green after several seconds of testing, then the SPF+/XFP link is passing the Built In Link Test. 6. The Built in Link Test continues to run until Switch 1 on the master side is set back to Data mode. Perle S-10GT Media Converter Installation Guide 13

Loopback Test This mode is not used in conjunction with BILT. 1. If either media converter is not a Perle 10GT unit then you need to set loopback mode on one of the media converters. (See the User s Guide that came with that media converter). 2. Use an alternative way to generate data to the unit set in loopback mode. Data received on the receiver (RX) will be looped back to the transmitter (TX) connection. Use a third party application to analyses the received data. Perle S-10GT Media Converter Installation Guide 14

Technical Specifications Maximum Power Consumption 9-30 vdc, unregulated (12vDC Nominal) S-10GT-SFP+ Operating Temperature 0 C -50 C (32 F - 122 F) Maximum Power Consumption 10* Storage Temperature -25 C -70 C (-13 F -158 F) Operating Humidity 5% to 90% non-condensing Storage Humidity 5% to 95% non-condensing Operating Altitude Up to 3,048 m (10,000 ft) Maximum Power Consumption 9-30 vdc, unregulated (12 vdc Nominal) S-10GT-XFPH Operating Temperature 0 C -50 C (32 F - 122 F) Maximum Power Consumption 15* Storage Temperature -25 C -70 C (-13 F -158 F) Operating Humidity 5% to 90% non-condensing Storage Humidity 5% to 95% non-condensing Operating Altitude Up to 3,048 m (10,000 ft) (*See Perle Datasheet for more detailed information) SFP+ and XFP Support MSA Compliant SFP+ MSA complaint Class 1,2,3 and 4 XFP modules for the S- 10GT-XFPH 1G copper modules 1G fiber modules SFP+ supports CX1 modules XFP supports CX4 modules Fiber Cabling Requirements MM: SM: 50/125 microns, 62.5/125 microns 9/125 microns Copper Cable Requirements Category 6A Straight through or Ethernet crossover Perle S-10GT Media Converter Installation Guide 15

Compliance Information FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EN 55022 Class A WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Warranty / Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml Copyright 2017 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited. Perle S-10GT Media Converter Installation Guide 16