Increased Cooling Demand Means More Energy Saving Opportunities. Wednesday, May 25 th, 2016

Similar documents
Efficiency Works: Commercial Assessments and Business Efficiency Grants Drive Results. Rocky Mountain Utility Efficiency Exchange. September 25, 2014

Efficiency Works Business: 2017 Rebates & Goals. January 17, 2017

Efficiency Programs Overview & Update

where we are, where we could be, how we can get there. 12/14/2011

Commercial HVAC Efficiency Regulations and Refrigerants Are Changing: Are You Ready?

Advanced RTU Campaign Webinar June 17, 2013

Efficiency Works Business: 2018 Rebates & Goals. January 25, 2018

2018 Business Cooling Equipment Rebate Application

Upstream Rebate Programs UC Davis Meeting

Optimizing the Existing Building Cx Process:

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Silicon Valley Power Data Center Program Rebate Application

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

SRP Energy Efficiency Program Update SWEEP Regional Energy Efficiency Workshop

Building Tune-Up Program Application

Prescriptive Program Rebate Application

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

How to Get the Most out of Your Rooftop AC

ComEd Retro-Commissioning and Monitoring-Based Commissioning

Advanced RTU Campaign Taking Action Toward Efficient RTUs Michael Deru February 25, 2014

Continuous Energy Improvement. The Pepco C&I Energy Savings Plan Perspective April 12, 2011

Trends in Data Center Energy Efficiency

Energy Engineering: Tools and Trends

CenterPoint Energy Retro-Commissioning Program Application

Energy Efficient Commercial Building Tax Deduction Internal Revenue Code Section 179D

Current and Future Opportunities for Advanced C&I HVAC Systems. High Efficiency Heating RTUs National Symposium on Market Transformation

A New Paradigm for Retrocommissioning: Moving Building Science to Green Collar Trades

Advanced RTU Campaign Webinar

Presentation. Guaranteed Energy Savings Performance Project

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

E e n rgy g y St S ud u y y Pr P og o r g ams December 2011

Critical Facilities Existing Building Commissioning (EBCx)

NCSL Energy Policy Summit

FY19 SRP Business Solutions Standard Program Manual

Advanced RTU Campaign Technical Resources: Evaluating Performance December 10, 2013

Building the Future. Energy Efficiency on Campus Real World Data. ERRAPPA Spill Prevention and Emergency Response/Contingency Plans 7/27/2017

Commercial HVAC and Other Measures for 7P. Outline

HVAC Incentives Application Energy Solutions for Business

HVAC System Energy Savings Opportunities

ASHRAE elearning Course Catalog

Metering and Energy Retrofits for the GSA

Nonresidential HVAC Stakeholder Meeting #3

Data Center. Utilities and data centers: a win-win for energy efficiency. 1 August DNV GL August 2017 SAFER, SMARTER, GREENER

Transformative Wave Technologies Kent, Washington

CARRIER edesign SUITE NEWS

Business Rebates TRADE ALLY TRAINING MANUAL

2013 Building Energy Efficiency Standards Non-Residential HVAC Alterations

Achieving Operational Excellence

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

FirstEnergy Energy Efficiency 2016 Schaedler Yesco Expo. April 26 & 27, 2016

Danfoss Turbocor Learning Center

PARK HILL SCHOOL DISTRICT REQUEST FOR PROPOSAL NW Barry Road Kansas City, MO SUMMER HVAC

Validation and Uncertainty Characterization for Energy Simulation

Application Sections. I. Smart Energy Information II. Energy Efficiency and Distributed Energy Resources... 6

2017 AEP Ohio Business Incentive Programs

PROCESS COOLING STUDY WORKSHEET

Commercial Retro-Commissioning Program Manual for 2016 SECTION 1

RAPID CITY CALL CENTER 1400 TURBINE DRIVE RAPID CITY, SD FOR SALE / FOR LEASE OFFICE / CALL CENTER 133,102 SQ. FT.

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Advanced Rooftop Controller

Board of Directors Meeting. April 27, 2017

Thank you for joining today s webinar: Advancing DR Automation and Standards in Building Codes (CA Title 24)

Developing an Action Plan: Building Energy Metering and Beyond

EER Optimizer for DX Air Conditioners

2-TIER AUTHORIZED INFORMATICA RESELLER PROGRAM GUIDE

Polycom Upgrade Program Video Products

Interfacing with Packaged Equipment

Rooftop Unit HVAC Efficiency:

PARK HILL SCHOOL DISTRICT REQUEST FOR PROPOSAL NW Barry Road Kansas City, MO SUMMER HVAC

1/28/2013. ASHRAE Standard ASHRAE Standard Aiming at 50% Energy Savings For ASHRAE Standard 90.

Experiences Commercializing FDD in the Northwest. Danny Miller, President Transformative Wave

Savings Central. Central Hudson Trade Ally Online Rebate Form Training

Our Local Affiliate Partner. Chillersplus.com

Retro-Commissioning Report

Pilot: Window Air Conditioner Replacement Initiative

Instructions for Participating in ASHRAE s. Commissioning Process Management Professional (CPMP) Certification Program

Doing More with Less: Maintaining, Operating, and Improving your BMS. Bernard Keister, V PE Senior Engineer Guttmann & Blaevoet Consulting Engineers

OUR ACHIEVEMENTS 4/27/2015. Why Certify? AEE Georgia Building Certifications. Pamela Moua, EIT, LEED AP O+M Sustainability Manager, Associate Engineer

Climate Technologies Investor Update

Danfoss Turbocor Learning Center

Water Smart Irrigation Professional Certification Program Pilot Program Application

Up on the Roof Up on the roof I've found a paradise that's trouble proof, up on the roof. C. King/G. Goffin 1962

Utility Incentives for RTU FDD in California. Mel Johnson Southern California Edison

ELITE CONTRACTOR FUJITSU ELITE CONTRACTOR PROGRAM FOR INSTALLERS OF FUJITSU HALCYON AND AIRSTAGE SYSTEMS

Taking Control of your Rooftop Units- Retrofitting RTU Controls. DTE Energy. Presented by

Energy Solutions for Buildings

Why and How to Benchmark Building Energy Use in Office Buildings

Polycom Upgrade Program Video Products

AIA Iowa #A203. NCARB & You: IDP, ARE, & Certification Course Number. Ryan Misner, AIA, NCARB October 15, 2015

1-TIER AUTHORIZED INFORMATICA RESELLER (AIR)

The Premium Economizer: An Idea Whose Time Has Come

Reseller Incentive Terms and Conditions

Contents. Introduction and Company Overview Mission Vision Values Key personnel Our Clients Certificates and Licences...

that may have a direct effect on your bottom line. The question

Gold: points Platinum: 80+ points. Certified: points Silver: points

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

CompTIA Continuing Education (CE) User Guide V13

18 th National Award for Excellence in Energy Management. July 27, 2017

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Transcription:

Increased Cooling Demand Means More Energy Saving Opportunities Wednesday, May 25 th, 2016

AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Increased Cooling Demand Means More Energy Saving Opportunities AIA Course Number: EW03.25.15 Speakers: Bryce Brady and Kelley Gonzales

Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates of Completion for both AIA members and non AIA members are available upon request. for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation. This course is registered with AIA CES

Continuing Education Units (CEUs) and Course Evaluation Sign in Sheet: When you sign the sheet, PLEASE WRITE LEGIBLY! AIA column fill in this column with your AIA ID# if would like us to apply for CEUs on your behalf. BPI column fill in this column with your BPI number if would like us to apply for CEUs on your behalf. If you do not fill in your ID#, it is your responsibility to email it to the CGBG within 3 business days. Certificates of Completion: If you need a Certificate of Completion, please check the appropriate box on the sign in sheet. Course Evaluations: If you would like to fill out a course evaluation form, please email the CGBG within 3 business days to request one. The Colorado Green Building Guild (CGBG) is the Provider for this course: Email: julie.nelson@bgbg.org

Course Description Some of the largest, untapped energy and money saving opportunities are in commercial space cooling. Review local case studies and learn to take advantage of advances in cooling technology such as evaporative and free cooling options. Also learn how Efficiency Works rebates and programs support low cost cooling. Approved for.75 hours BPI and 1.5 hours AIA LU/HSW With over 30 years of experience in the construction, energy efficiency and utility industry, Kelley Gonzales currently manages the commercial Demand Side Management program for Fort Collins Utilities. Gonzales holds a B.S. in Construction Management and is certified as an Energy Manager, Energy Auditor and Demand Side Management professional. Currently a Customer Services Engineer for Platte River Power Authority, Bryce Brady spends the majority of his time on the Efficiency Works for Business incentive programs. Brady has experience working with both energy efficiency contractors and utility customers, implementing energy efficient upgrades that take advantage of the various incentive programs available. Brady holds a B.S. in Architectural Engineering, Masters in Business Administration and is a registered Professional Engineer.

Learning Objectives At the end of the this course, participants will be able to:.. Identify minimum cooling efficiency requirements related to code and incentive programs.. Understand case studies of other Cooling upgrades and the associated energy savings.. Recognize new advances and alternative applications in cooling technologies in commercial space cooling.. Identify upcoming cooling incentive program changes

This concludes The American Institute of Architects Continuing Education Systems Course Provider: Colorado Green Building Guild Contact Information: katherine@coloradogreenbuildingguild.org

Contact Information Kelley Gonzales Fort Collins Utilities Senior Energy Services Engineer 970-221-6857 Kgonzales@fcgov.com Bryce Brady Platte River Power Authority Customer Services Engineer 970-229-4811 bradyb@prpa.org 8

Overview Current Cooling Rebate Offerings from Efficiency Works Program Code Review of Minimum Efficiencies Case Studies How others have saved! Future Incentive Program Offerings and Changes 9

Platte River-City Relationship Residential Commercial Generation Transmission Platte River Power Authority Sole Supplier Joint Ownership / Equity Local Governance Distribution Estes Park Fort Collins Longmont Loveland Industrial Customers 10

Efficiency Works for Business What s Available? Facility Assessments Building Specific Reports Technical Assistance Building Tune-up Integrated Design Assistance Efficiency Improvement Incentives Lighting Cooling Motors Building Envelope Kitchen Equipment Custom Projects 11

Cooling Rebates are Available! 12

Cooling Rebates Tiers on unit size and efficiency 13

Cooling Rebates (cont d) Additional rebates based on features/add-ons 14

Rebate Information is Available www.efficiencyworks.co 15

Get Started! 1. Develop project proposal and obtain customer commitment 2. Complete a rebate application and submit to Efficiency Works for pre-approval with detailed project quote info@efficiencyworks.co 3. Complete Project 4. Submit final paperwork to Efficiency Works Final invoice and W9 Signed request for payment Final application 5. Receive payment with in 4 to 6 weeks Rebate can be paid to contractor or customer 16

Code Requirements IECC 2012 (currently) Equipment Cooling Capacity Cooling Capacity Minimum Code Required Efficiency** Minimum Qualifying Efficiency for Incentives Type (tons) (Btu/h) 2012 IECC (Must Meet Both) Peak Seasonal Peak Seasonal PTAC <4.2 <50,000 Btu/h 9.3 11.7 EER n/a 12.0 EER n/a Split system* <5.4 <65,000 Btu/h n/a 13.0 SEER 12.5 EER 15.0 SEER Unitary* <5.4 <65,000 Btu/h n/a 13.0 SEER 12.0 EER 15.0 SEER Unitary* 5.5 11.2 65,000 134,999 Btu/h 11.2 EER 11.4 IEER 12.0 EER 13.8 IEER Unitary* 11.3 19.9 135,000 239,999 Btu/h 11.0 EER 11.2 IEER 12.0 EER 13.0 IEER Unitary* 20 63.3 240,000 759,999 Btu/h 10.0 EER 10.1 IEER 10.6 EER 12.1 IEER * All systems are air cooled **ASHRAE Standard 90.1 2010 (Table 6.8.1A & D) Note: Cx is required. 17

How are others saving? Types of Upgrades New RTU s Including early retirement Evaporative Cooling Advanced Controls After market retrofits New unit upgrades BTU/Retrocommissioning 18

Case Studies Commercial Customer with Existing Air Cooled Chiller Background: 180,000 square foot office building 3 Story Building Built in 1998 Air cooled McQuay chiller Capacity 425 tons Problem: Existing air cooled chiller suffers from recirculation of warm air and cooling demands that cannot satisfy the tenants. 19

Case Studies Commercial Customer with Existing Air Cooled Chiller Solution: Install an evaporative precooling system to improve condenser and chiller efficiency and restore design cooling tonnage availability. Evaporcool condensing pre cooler Cost $85,000 Utility savings $12,000/yr Electric savings 117,205kWh/yr Rebate $44,500 20

Case Studies Commercial Office Building with Background: 30,000 sq ft office building 3 Story Building Built in the late 1970s Multiple RTUs 15 standard RTUs with DX cooling of various vintage Units are 5.6 to 7.5 tons each Problem: Aged units that have outlived their useful life and are failing. Many do not have economizers or programmable thermostats. 21

Case Studies Commercial Office Building with Multiple RTUs Solution: Replace units one at a time with new high efficiency RTUs (12.6 EER and 14.5 IEER) with economizers and programmable thermostats. Cost range $12,000 $15,000 Utilities savings avg. $200/unit/yr * Electric savings avg. 2,200 kwh/unit/yr* Rebate avg. $1,400/unit * Does not include savings related to programmable thermostat 22

Case Studies Commercial Customer Packaged RTU with Evaporative Condensers Background: 156,000 square foot office building Built in 2002 Standard efficiency DX cooling RTU Four 75 ton units (300 tons total) Problem: Standard efficiency units with maintenance issues and failing compressors. 23

Case Studies Solution: Replace four Trane 75 ton RTUs with higher efficiency units including Premium Ventilation and Evaporative Condensing. Cost $913,000 Utility savings $15,000/yr Electric savings 390,000kWh/yr Rebate $54,250 (includes early retirement) 24

Advanced Controls: Upgrade Potential Why Advanced RTU Controllers? Cost effective for utilities DR ready Cost effective for customers Additional web interface and fault diagnostics for maintenance Energy Saving Measures Integrated Economizer with Differential Changeover Control Variable Speed Fan Control to Match the Needs of the Space Served Elimination of Over-Ventilation via Demand Control Ventilation (DCV) Remediation of Service and Operational Issues 25

Results All Sites Data supplied by Transformative Wave Technologies (Catalyst) 26

Applying the Data Avgerage HVAC Electric Power vs OSA Temp 14 14 12 12 Avg Total Pwr (kw) 10 8 6 4 2 10 8 6 4 2 Runtime @ OSA Temp (Hrs) 0 30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90 94 Outside Air Temperature ( F) 0 Runtime @ OSA Temp Standard Mode Electric CATALYST Mode Electric 27

Another Way to Save: Building Tune-up What is the Building Tune-up Program? Tune-up (or retro-commission) existing building/energy systems Identify and implement low to no cost measures resulting in less than a 2 yr payback Provide financial incentives for cost effective energy savings Identify EE measures not covered by BTU that may qualify for other rebate programs (EW Business) 28

Building Tune-up General prerequisites for all buildings: The facility shall be at least 2 years old Facility is served by four utilities and on commercial rate HVAC equipment shall be between 2-20 years old and must have regular preventive maintenance All Projects require completed application and pre-approval. BTU project must be performed by qualified Retro-commissioning Service Provider (RSP) 29

Building Tune-up All types of Buildings: Schools Office Gov t Heath Club Retail Light industrial Warehouse Industrial 30

Building Tune-up Project Tiers Tier #1 Small Buildings Typically less than 50K sq ft, single zone thermostats, roof top units (RTU) or split systems Tier #2 Medium Typically between 50K to 100K sq ft, BAS and trending, AHU/VAV systems Tier #3 Large Buildings Typically greater than 100K sq ft, BAS and trending, central plant and industrial processes Rebate is based on $0.15 per sq ft for implementation of selected measures and customer commits $0.05 per sq ft. Rebate Rebate is based is based on on 100% 100% of of the cost the of cost RCx of study RCx and study implementation implementation support and support verification and and by verification RSP and customer by RSP and commits $0.05 customer per sq commits ft for implementation sq ft of for selected implementation measures. of $0.05 per selected measures. 31

What s Next (late 2016+) Midstream Cooling Incentive Program (Pilot) What The Efficiency Works Midstream Cooling Incentive Program (EW MCIP) provides incentive payments to HVAC distributers in the region that stock and sell high efficiency cooling units based on a per ton amount for the new equipment sold depending on the size and efficiency of the units. Why Make it easier for the end use customer High Efficiency units right off the shelf. 32

Why target distributors? 1. Distributors control equipment stocking 2. Influences contractors purchase decisions 3. Fewer market actors means lower implementation costs 4. Distributors influence 90% of equipment sales 5. Most qualified sales staff: a) With financial skills b) With technical skills c) With sales skills 10,000s ~9 10-20 100s Manuf. Dist. Contractor Typical HVAC Supply Chain Commercial Customers 33

Does it Work? PG&E HVAC Results: 1993 to 2014 34

Midstream Sales Process Customer 1. HVAC equipment fails 2. Solicits replacement estimate 5. Receives, evaluates and selects bid based on value. Contractor 3. Solicits equipment pricing from HVAC distributors 4C. Provides bid to customers 4B. Provides equipment pricing with incentives factored in Distributor Utility 4A. Provides Incentive to stock and upsell high efficiency equipment 35

Cooling Equipment Incentives Midstream Incentives: PTAC s Split System (<5.4 tons) Unitary Roof Top Units (up to 63.3 tons) 36

Implementation Timeline Current Program and Incentives Midstream Incentive Program Pilot with Incentives going to Distributors June 2016 Oct No More Rebate Paperwork. Distributor will get service address and apply incentives to quote. Code/Permit Requirements do NOT change. Jan 2017 37

Downstream Cooling Incentives Measures to still be eligible for downstream incentives: Measure Description Incentive Early Retirement Evaporative Condensing Advanced Evaporative Cooling Economizer Controls PTAC/PTHP Controls Advanced RTU Controller Incentive is available for retiring working standard air conditioner units less than 20 years old. Commissioning required Pre cools the air entering the condenser of a rooftop unit or aircooled chiller with mist or an evaporative media. Direct, Direct/Indirect, or Indirect evaporative coolers. Continuous water 'bleed' systems for sediment control DO NOT qualify. Must guarantee air quality against bacteria, mold, and include a maintenance plan. Add an economizer to either an existing unit or to a replacement high efficiency unit where an economizer previously did not exist. Motion Sensor or Card Lock control with setback capabilities. After market controllers that utilize variable supply fan control combines with integrated economizer and demand ventilation controls. $100 / ton $100 / ton $0.20 / cfm $250 / unit $75 / unit $2,000 / unit 38

Become an Efficiency Works Provider Requirements: 1. Complete one project including application 2. Customer rating 3. Agreement and Insurance Updated semi-annually Provided to customers On website BTU Retro Commissioning Providers must complete RSP application to qualify 39

Future Trainings (4 th Wednesday) New Financing Options for Commercial Energy Efficiency June 22nd, 2016. 8:30 am 10:00 am Integrated EV and PV July 27th, 2016. 8:30 am 10:00 am Tour of Platte River Power Authority s Rawhide Energy Station and the Silver Sage Windpower Project Sept 28th, TBD New Options for Managing Peak and Facility Demand Oct 26, 8:30 10 am And more at http://efficiencyworks.prpa.org/training/ 40

Thank You Any Questions?? Contact Information Kelley Gonzales Fort Collins Utilities Senior Energy Services Engineer 970-221-6857 Kgonzales@fcgov.com Bryce Brady Platte River Power Authority Customer Services Engineer 970-229-4811 bradyb@prpa.org 41

Efficiency Works Blank Slide 42

Efficiency Works Blank Slide 43

Application Process The software and application process: https://energy solution.com/project/distributor hvac program/ 44

Typical HVAC Sales Process 1. HVAC equipment fails 2. Solicits replacement estimate 5. Receives, evaluates and selects bid based on first cost. 3. Solicits equipment pricing from HVAC distributors 4B. Provides bid to customers 4A. Provides equipment pricing Where s the Utility? 45