IBM Power Systems 57D7/57B4 Adapter Write Cache

Similar documents
Supported Linux distributions for POWER8 Linux on Power systems

... RAID on Linux on POWER Topics on software and hardware RAID for Linux on POWER

ULTEO OPEN VIRTUAL DESKTOP SUSE LINUX ENTERPRISE SERVER (SLES) 11 SP1 SUPPORT

QuickSpecs. Models. Overview

VMmark V1.0.0 Results

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

Production Installation and Configuration. Openfiler NSA

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview

Storage Controller Information

Using UCS-Server Configuration Utility

Enterprise Server Midrange - Hewlett Packard

Downloading and installing Db2 Developer Community Edition on Red Hat Enterprise Linux Roger E. Sanders Yujing Ke Published on October 24, 2018

PowerVM Lx86 for x86 Linux Applications Administration Guide

Release Notes for (Supporting 3ware 9690SA and 9650SE controllers)

New IBM POWER6 processors for the Power 570 enable you to get more processing power with fewer processors

Installing and Upgrading the Cisco Video Surveillance Operations Manager (VSOM) Release 4.2.1

Dell Host Bus Adaptor User s Guide

Storage Controller Considerations

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

SUPERTRAK EX8300, EX8350 RAID 6 UPGRADE & PRIMER

RocketRAID mini-sas 6G HBA Series Data RAID. Installation Guide

RAID Controller Considerations

IBM Power 520 and 550 Express offer faster processor options and popular, easy-to-order configurations

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

readme.txt README.TXT

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers

Dell EMC OpenManage Deployment Toolkit for

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Storage Controller Considerations

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired

IBM Emulex 16Gb Fibre Channel HBA Evaluation

readme.txt README.TXT

Series Controller_Readme_8_2010.txt README.TXT

SanDisk DAS Cache Compatibility Matrix

Xen Summit Spring 2007

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM i Version 7.3. Systems management Disk management IBM

Deep Dive -PCIe3 RAID SAS Adapters Optimized for SSD s

Install ISE on a VMware Virtual Machine

IBM. Systems management Disk management. IBM i 7.1

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004

Downloading and installing Db2 Developer Community Edition on Ubuntu Linux Roger E. Sanders Yujing Ke Published on October 24, 2018

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

Clearswift SECURE Gateway Installation & Getting Started Guide. Version 4.3 Document Revision 1.0

Backup Solution Testing on UCS B-Series Server for Small-Medium Range Customers (Disk to Tape) Acronis Backup Advanced Suite 11.5

readme.txt README.TXT

Power Systems with POWER8 Scale-out Technical Sales Skills V1

Flush Dns Settings Linux Redhat 5 Step Step

IBM and HP 6-Gbps SAS RAID Controller Performance

Red Hat Network Satellite 5.0.0: Virtualization Step by Step

RocketRAID esata 3G HBA Series Data RAID Installation. Guide

IBM POWER7 Systems Express Blades Quick Reference Guide November 2011

IBM Endpoint Manager. OS Deployment V3.8 User's Guide - DRAFT for Beta V.1.0 (do not distribute)

SUSE Linux Enterprise 12 Service-Pack Migration What is possible and what supported

Backup Solution Testing on UCS for Small-Medium Range Customers (Disk to Tape)-SAS

SAP SD Benchmark with DB2 and Red Hat Enterprise Linux 5 on IBM System x3850 M2

C122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite

IBM s Data Warehouse Appliance Offerings

DUAL OS INSTALLATION

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

IBM InfoSphere Streams v4.0 Performance Best Practices

Configuring Boot Order and RAID Levels

Installing and Upgrading Cisco Video Surveillance Manager Release 6.3

Installation and Using Guide

Client TM 2.0 SP2 for Linux

Running Blockchain in Docker Containers Prerequisites Sign up for a LinuxONE Community Cloud trial account Deploy a virtual server instance

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

QuickSpecs. What's New. Models. Overview

Backup Solution Testing on UCS B and C Series Servers for Small-Medium Range Customers (Disk to Tape) Acronis Backup Advanced Suite 11.

QuickSpecs. What's New. Models. Overview

Backup Solution Testing on UCS for Small Medium Range Customers (Disk-to-Disk) Backup Exec 2012

NetApp SANtricity Cloud Connector 3.1

Getting Started with. Agents for Unix and Linux. Version

McAfee Endpoint Security Threat Prevention Installation Guide - Linux

Migrate Cisco Prime Collaboration Assurance

Dell OpenManage Deployment Toolkit 5.5 for Embedded Linux Release Notes

QuickSpecs. What's New. Models. Overview

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

Red Hat Enterprise Linux 6.4 Security-enhanced. Linux User Guide >>>CLICK HERE<<<

RocketRAID Series Data RAID Set Up Guide

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview

RocketRAID 6G mini SAS HBA + Rocket EJ220 Device. Board Boot Camp Installation Guide

SUSE Cloud Admin Appliance Walk Through. You may download the SUSE Cloud Admin Appliance the following ways.

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Intel Server System SC5400RA

SANS Institute - Operations Essentials. Operating System Installation Guidelines. Windows XP Professional Installation. Creating Boot Disks

PRODUCT DOCUMENTATION. Backup & Replication v5.0. User Guide.

Series-6-Controller_Readme_3_2011.txt

Dell Lifecycle Controller Integration Version 3.0 For Microsoft System Center Configuration Manager User's Guide

Install Oracle 11g Client On Linux Command Line

Install ISE on a VMware Virtual Machine

README.TXT

Dell EMC Host Bus Adapter User's Guide

IBM POWER7 Systems Express Blades Quick Reference Guide October 2012

Clearswift SECURE Gateway Installation & Getting Started Guide. Version Document Revision 1.0

Transcription:

IBM Power Systems 57D7/57B4 Adapter Write Cache 1 of 15

Contents 1 Feature Description 3 2 Software and Hardware Requirements 4 2.0.1 Supported Systems...................................... 4 2.0.2 Supported Storage Adapter Backplanes.......................... 4 2.0.3 Supported Linux Operating System Releases & Configurations............. 4 2.0.4 Minimum SAS RAID Adapter Firmware Level...................... 5 2.0.5 Minimum Linux iprutils Package Level........................... 5 3 Installation Instructions 6 3.1 Linux Software Installation Instructions.............................. 6 3.1.1 YUM Repository....................................... 6 3.1.1.1 Red Hat...................................... 6 3.1.1.2 SUSE........................................ 6 3.1.2 Manual Installation..................................... 7 3.2 Adapter Firmware Installation Instructions............................ 8 4 Feature Enablement 12 4.1 Curses Interface............................................ 12 4.2 Command Line Interface....................................... 14 5 Support 15 2 of 15

Chapter 1 Feature Description This document describes how to enable and use the new volatile adapter write cache feature for the integrated SAS controllers in the #EL3T and #EL3V SAS backplanes on IBM Power 8247-21L and 8247-22L systems, the integrated SAS controllers in the #EJ0N and #EJ0S SAS backplanes on the IBM Power 8247-42L, and the PCIe3 x8 SAS RAID adapter low profile Quad Port 6Gb (#EJ0J and #EJ0M). Once the required adapter firmware and Linux software prerequisites are installed, this feature is enabled by default, but can be manually disabled on a per RAID array basis. This feature enables a volatile write cache in the SAS RAID adapter into which data is written. This data is then later flushed to the underlying disks. This allows the RAID adapter to combine multiple host writes into fewer writes to the disks. It also enables the RAID adapter to issue stripe writes to RAID 5 or 6 arrays, when a full parity stripe of data is available in the cache, which can eliminate read-xor write overhead that may occur when a write cache is not available. This can provide a noticeable performance advantage for some write workloads. The adapter firmware which implements this volatile write caching feature includes support for a SYNCHRONIZE CACHE mechanism. This allows journaled filesystems in the Linux operating system to flush any previously written data prior to updating the filesystem journal. This ensures the filesystem data stays coherent with respect to the journal in the case of an unexpected power loss of the system. For use cases which access the RAID array block devices directly and bypass any filesystems in Linux, it may be desireable to disable this feature, particularly if the software has not been written to issue SYNCHRONIZE CACHE commands. Instructions on how to disable this feature are described later in this document. 3 of 15

Chapter 2 Software and Hardware Requirements The required hardware, firmware, and software levels for this feature are described below. 2.0.1 Supported Systems IBM Power 8247-21L IBM Power 8247-22L IBM Power 8247-42L 2.0.2 Supported Storage Adapter Backplanes #EL3T: PCIe3 x8 SAS RAID internal adapter 6Gb #EL3V: PCIe3 x8 SAS RAID internal adapter 6Gb (Split Backplane) #EJ0N: PCIe3 x8 SAS RAID internal adapter 6Gb (4U) #EJ0S: PCIe3 x8 SAS RAID internal adapter 6Gb (4U) (Split Backplane) #EJ0J: PCIe3 x8 SAS RAID adapter Quad Port 6Gb 1 #EJ0M: PCIe3 x8 SAS RAID adapter low profile Quad Port 6Gb 1 2.0.3 Supported Linux Operating System Releases & Configurations Bare Metal Systems (indicated by #EC16): Ubuntu Server 16.04, or later PowerKVM 3.1 Systems (indicated by #EC40) or PowerKVM 2.1 (#EC20) Not supported Other environments, such as PowerVM (not PowerKVM, not Bare Metal) Red Hat Enterprise Linux 6.5, or later Red Hat Enterprise Linux 7.2, little endian, or later Red Hat Enterprise Linux 7.2, big endian, or later 1 Single adapter configurations only, feature not supported for dual adapter, HA configurations 4 of 15

SUSE Linux Enterprise Server 11, Service Pack 4, or later SUSE Linux Enterprise Server 12, Service Pack 1, or later Ubuntu Server 16.04, or later 2.0.4 Minimum SAS RAID Adapter Firmware Level 14511900 2.0.5 Minimum Linux iprutils Package Level 2.4.11 5 of 15

Chapter 3 Installation Instructions 3.1 Linux Software Installation Instructions 3.1.1 YUM Repository Installing via the IBM Power Tools YUM repository is the preferred method for obtaining the required 2.4.11 version of the iprutils package. Use this method if your system has connectivity to the external network and is able to download files direct from the internet. If you are using Ubuntu 16.04, the requisite version of iprutils should be able to be installed using apt-get, like any other package that is part of the Ubuntu distribution. In this case, you can skip ahead to section 3.2 on updating the adapter firmware. First, configure the IBM Power Tools YUM repository. Go to the following page for instructions on how to download the configuration RPM file and how to configure the repository: http://www14.software.ibm. com/webapp/set2/sas/f/lopdiags/yum.html. Once the repository is configured, upgrade the iprutils package to the 2.4.11 version from the newly configured repository. During this process, you will be prompted to accept the GPG key for the newly added YUM repository. Please allow this new GPG key to be accepted, otherwise the package installation will be aborted. 3.1.1.1 Red Hat # yum update iprutils 3.1.1.2 SUSE # zypper update iprutils The currently installed version of iprutils can be verified with the following command. # iprconfig --version iprconfig: 2.4.11.1 6 of 15

Ensure the iprutils daemons are enabled to start on the next boot. Please note, that the iprinit daemon must be enabled and running for this write cache feature to get enabled at boot time. # chkconfig iprinit on # chkconfig iprupdate on # chkconfig iprdump on 3.1.2 Manual Installation Use this method if either the YUM repository method fails or your system is unable to download files directly from the internet. Download the iprutils package directly from one of the following locations, depending on your OS level, and transfer to the server. RHEL 6.5, or later http://public.dhe.ibm.com/software/server/power/linux/yum/oss/rhel/6/ppc64/iprutils-2.4.11-1. 41.1.ppc64.rpm RHEL 7.2 Little Endian http://public.dhe.ibm.com/software/server/power/linux/yum/oss/rhel/7/ppc64le/iprutils-2.4. 11-1.1.ppc64le.rpm RHEL 7.2 Big Endian http://public.dhe.ibm.com/software/server/power/linux/yum/oss/rhel/7/ppc64/iprutils-2.4.11-1. 41.1.ppc64.rpm SLES 11 SP4 http://public.dhe.ibm.com/software/server/power/linux/yum/oss/sles/11/ppc64/iprutils-2.4.11-1. 41.1.ppc64.rpm SLES 12 SP1 http://public.dhe.ibm.com/software/server/power/linux/yum/oss/sles/12/ppc64le/iprutils-2.4. 11-1.41.1.ppc64le.rpm Next, remove the old iprutils package and then install the 2.4.11 version by running the following commands on the server to which you transferred the iprutils rpm package. # rpm -e iprutils # rpm -ivh iprutils-2.4.11-1.41.1.ppc64.rpm The currently installed version of iprutils can be verified with the following command. # iprconfig --version iprconfig: 2.4.11.1 7 of 15

Ensure the iprutils daemons are enabled to start on the next boot. Please note, that the iprinit daemon must be enabled and running for this write cache feature to get enabled at boot time. # chkconfig iprinit on # chkconfig iprupdate on # chkconfig iprdump on 3.2 Adapter Firmware Installation Instructions The required 14511900 version of SAS adapter firmware to enable this feature can be downloaded from IBM Fix Central at the following URL: http://www.ibm.com/support/fixcentral/main/quickorder?parent= Power%2BIO%2BFirmware&product=ibm/io/featurecode/EJ0T&release=all&platform=all&function=all&source= fc. The pci.1014034a.51-14511900-1.linux.noarch.rpm file should be downloaded. Once downloaded, install to your Linux system with the rpm command. # rpm -ivh pci.1014034a.51-14511900-1.linux.noarch.rpm To begin the process of installing the new adapter firmware, first login as root on the target server, then run iprconfig. You should see a screen similar to this: IBM Power RAID Configuration Utility Select one of the following: 1. Display hardware status 2. Work with disk arrays 3. Work with disk unit recovery 4. Work with configuration options 5. Work with microcode updates 6. Devices Statistics 7. Analyze log Selection: e=exit Select option 5. Work with microcode updates, and press Enter. 8 of 15

Select option 2. Download latest microcode to all devices, and press Enter. Work with microcode updates Select one of the following: 1. Download microcode 2. Download latest microcode to all devices Selection: e=exit q=cancel You should then see a screen similar to the following screen, showing one or more adapters to be updated with the pci.1014034a.51.14511900 firmware image. Confirm Microcode Download The following devices are going to be updated. ATTENTION: System performance may be affected during the microcode download process. Download may take some time. Press Enter to continue. q=cancel to return and change your choice. Name Version Date Image File ------ --------- --------- ----------------------------- sg6 14511900 05/12/16 /lib/firmware/pci.1014034a.51.14511900 sg7 14511900 05/12/16 /lib/firmware/pci.1014034a.51.14511900 q=cancel Press Enter and follow the prompts. Once the operation is completed, return to the main menu by pressing e if necessary. 9 of 15

The current version of the adapter firmware can be confirmed by selecting option 1. status. This should present a screen similar to this: Display hardware Display Hardware Status Type option, press Enter. 1=Display hardware resource information details OPT Name PCI/SCSI Location Description Status --- ------ ------------------------- ---------------------------- ------------ 0003:70:00.0/0: PCI-E SAS RAID Adapter Operational sda 0003:70:00.0/0:2:0:0 RAID 0 Array Optimized 0003:70:00.0/0:0:0:0 RAID 0 Array Member Active sdb 0003:70:00.0/0:2:1:0 RAID 10 Array Optimized 0003:70:00.0/0:0:1:0 RAID 10 Array Member Active 0003:70:00.0/0:0:2:0 RAID 10 Array Member Active sdc 0003:70:00.0/0:2:2:0 RAID 5 Array Optimized 0003:70:00.0/0:0:3:0 RAID 5 Array Member Active 0003:70:00.0/0:0:4:0 RAID 5 Array Member Active 0003:70:00.0/0:0:5:0 RAID 5 Array Member Active More... e=exit q=cancel r=refresh t=toggle f=pagedn b=pageup Using the arrow keys, place the cursor next to the PCI-E SAS RAID Adapter, type 1, and press Enter. 10 of 15

This should display a screen similar to the screen below. IOA Hardware Resource Information Details Manufacturer.............. : IBM Machine Type and Model......... : 57D7001SISIOA Firmware Version............ : 14511900 Serial Number.............. : 00423088 Part Number............... : 0000000E2845 Plant of Manufacturer.......... : 00UE Write Cache Size............ : 256 MB DRAM Size................ : 512 MB Resource Name.............. : /dev/sg12 Physical location PCI Address............... : 0003:70:00.0 Resource Path.............. : FE SCSI Host Number............ : 0 Platform Location............ : U78CB.001.WZS00E2-P1-C14 Cache Protection............ : Synchronize Cache Press Enter to Continue e=exit q=cancel The Firmware Version field should show 14511900. You should now see a Cache Protection field showing a value of Synchronize Cache. Note, you may need to page down using f in order to see this value. 11 of 15

Chapter 4 Feature Enablement 4.1 Curses Interface By default, the write cache should now be set to Write Back, indicating the adapter volatile write cache is enabled. This can be confirmed by selecting option 4. Work with configuration options from the main menu, then pressing Enter. At this point you should see a screen like the following. IBM Power RAID Configuration Utility Select one of the following: 1. Work with SCSI bus configuration 2. Work with driver configuration 3. Work with disk configuration 4. Work with adapter configuration Selection: e=exit q=cancel Next, select option 3. Work with disk configuration from the menu and press Enter. 12 of 15

You should now see a screen similar to the following. Type option, press Enter. 1=Change Disk Configuration Change Disk Configuration OPT Name PCI/SCSI Location Description Status --- ------ ------------------------- ---------------------------- ------------- sda 0003:70:00.0/0:2:0:0 RAID 0 Array Optimized 0003:70:00.0/0:0:0:0 RAID 0 Array Member Active sdb 0003:70:00.0/0:2:1:0 RAID 10 Array Optimized 0003:70:00.0/0:0:1:0 RAID 10 Array Member Active 0003:70:00.0/0:0:2:0 RAID 10 Array Member Active sdc 0003:70:00.0/0:2:2:0 RAID 5 Array Optimized 0003:70:00.0/0:0:3:0 RAID 5 Array Member Active 0003:70:00.0/0:0:4:0 RAID 5 Array Member Active 0003:70:00.0/0:0:5:0 RAID 5 Array Member Active e=exit q=cancel r=refresh t=toggle Here, you will see all the physical disks as well as the logical RAID array devices as well. In this example, we will choose the first RAID array, sda. Using the arrow keys, navigate to the desired RAID array, select the device by entering 1, then press Enter. Change Configuration of Disk Current Disk configurations are shown. To change setting hit c for options menu. Highlight desired option then hit Enter. c=change Setting Queue Depth............... : 4 Device Write Cache Policy........ : Write Back Or leave blank and press Enter to cancel e=exit q=cancel Here we can see the Device Write Cache Policy is set to Write Back, as expected. If it is desired to disable the volatile adapter write cache for a specific RAID array, on this same screen, using the arrow keys, select the Device Write Cache Policy field, then type c to display the possible options. Then use the arrow keys to select the desired caching mode and press Enter. Press Enter again to confirm the change 13 of 15

4.2 Command Line Interface IBM Power Systems 57D7/57B4 Adapter Write Cache Alternatively, the iprconfig command line interface can be used to display and change the current caching mode. To list the current hardware RAID arrays current configured on the system use the following command: # iprconfig -c show-arrays Name PCI/SCSI Location Description Status ------ ------------------------- ------------------------- ----------------- sda 0003:70:00.0/0:2:0:0 RAID 0 Array Optimized sdb 0003:70:00.0/0:2:1:0 RAID 10 Array Optimized sdc 0003:70:00.0/0:2:2:0 RAID 5 Array Optimized To display the current caching mode for the first RAID array, we do the following: # iprconfig -c query-write-cache-policy sda write back Here we can see the write cache policy is set to write back, indicating the volatile adapter write cache is enabled for this array. To change this setting, you can do the following. # iprconfig -c set-write-cache-policy sda writethrough # iprconfig -c query-write-cache-policy sda write through Now let s change it back. # iprconfig -c set-write-cache-policy sda writeback # iprconfig -c query-write-cache-policy sda write back 14 of 15

Chapter 5 Support Problems this feature should be reported using the normal IBM Support process by opening a hardware support ticket. 15 of 15