ECEN 4606, UNDERGRADUATE OPTICS LAB

Similar documents
ECEN 4606, UNDERGRADUATE OPTICS LAB. Lab 12: Fiber optics

ECEN 4606, UNDERGRADUATE OPTICS LAB

Chapter 10 DIFFRACTION GRADING SAFETY NOTES

Fiber Optic and CAT 5-6 Installer Premise Cabling

Optical Fiber Assemblies

9. Polarization. 1) General observations [Room 310]

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

Figure 1 - Refraction

Geometrical Optics. 1 st year physics laboratories. University of Ottawa

PHYSICS. Chapter 34 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

PH 481/581 Physical Optics Winter 2018

Introduction. Lab Kit Contents

Optics: Reflection and Refraction (approx. completion time: 2.5 h) (3/28/11)

Chapter 12 Notes: Optics

Calibration of a portable interferometer for fiber optic connector endface measurements

Experiment 6. Snell s Law. Use Snell s Law to determine the index of refraction of Lucite.

TF-FS02 BLUETOOTH FUSION SPLICER Marine Street Farmingdale, NY (631) WE-CABLE

FO Field Genuine alternative to splicing

Disadvantages of Fiber-Optic Cabling

1 Laboratory #4: Division-of-Wavefront Interference

Panduit Certified Installer. Fiber Certification Review

March 2018 OM1 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OM4 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OS2 SINGLEMODE DUPLEX FIBRE OPTIC CABLE 500M

2/26/2016. Chapter 23 Ray Optics. Chapter 23 Preview. Chapter 23 Preview

Fiber Optic Communication Systems. Unit-03: Properties of Light.

Speed of light E Introduction

OPTICAL FIBER SOLUTIONS

Constructing a Low-Cost Mobile Eye Tracker

Physics 23 Fall 1988

General Physics Experiment 11

PHY 222 Lab 11 Interference and Diffraction Patterns Investigating interference and diffraction of light waves

Lab 10 - GEOMETRICAL OPTICS

FSM-30PF SPECIFICATIONS FOR FIBER FUSION SPLICER FOR HIGH TENSILE STRENGTH SPLICING 1. GENERAL

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

ipad Mini Wi-Fi Front Facing Camera Replacement

Interference of Light

Onwards and Upwards, Your near space guide. Figure 1. CheapBot Line Follower

Reflection and Refraction

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Fresnel's biprism and mirrors

Physical Optics. 1 st year physics laboratories. University of Ottawa.

Page 1 of 30. beam aligner 28.2 cm. platform with moving photodetector. Laser front at about 21.0 cm. slide holder for grating see recorded value

Light and Mirrors MIRRORS

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

Astronomy Lab Lenses and Telescopes

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

ELECTROSÓN. Data Sheet. HFBR-RXXYYY Series (POF) HFBR-EXXYYY Series (POF) Plastic Optical Fiber Cable and Accessories for Versatile Link

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Geometrical Optics. Theory. N = normal to surface. n r > n i. n i. n r. PHY 192 Geometrical Optics Spring

Setup Information Panosaurus May 3, 2011

Nanoparticle Optics: Light Scattering Size Determination of Polystryene Nanospheres by Light Scattering and Mie Theory

Diffraction and Interference of Plane Light Waves

Connectorized Aspheric Fiber Optic Collimators

Physical Optics. You can observe a lot just by watching. Yogi Berra ( )

Course Outline Cover Page

VISIBLE FIBER OPTIC FAULT LOCATOR

+ + Swift F1+ is a way on future splicers.

PHYSICS 116 INTERFERENCE AND DIFFRACTION

EXPERIMENT 8 PFUND REFRACTION

Polarization Microscope. Omano OM349P Series. User Guide

Lab 8. Interference of Light

Lasers and Femtosecond Lasers

Optics Final Exam Name

M = h' h = #i. n = c v

High Precision Fusion Splicer

Mirror Example Consider a concave mirror radius -10 cm then = = Now consider a 1 cm candle s = 15 cm from the vertex Where is the image.

The goal of this lab is to give you a chance to align and use a Pockel s Cell.

Lesson Plan Outline for Rainbow Science

LARGE DIAMETER SPLICING SYSTEM LDS 2.5

Intermediate Physics PHYS102

ENGR142 PHYS 115 Geometrical Optics and Lenses

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

GPX-3000 SERIES OPTICAL FIBER GLASS PROCESSORS

Lab 4 - The Microscope

Introduction to optical fibers and their applications

FIBRE OPTIC FUSION SPLICING EQUIPMENT SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

Physics 1230 Light and Color Fall 2012 M. Goldman. Practice Exam #1 Tuesday, Sept 25, Your full name: Last First and middle.

Kalahari and Quick Click Manual

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

A wide range of connectors are available to fit very specific needs.

Fiber Optic Prism Switch USER S MANUAL

BLIPS perfectly aligned cleaned by any impurity Gently press the lens

PHYS:1200 LECTURE 32 LIGHT AND OPTICS (4)

3M Fibrlok Optical Splice System

3SAE Large Diameter Splicing (LDS) System

OPTIX Module 3 Basic Interference of two Laser Beams

Interference of Light

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

CleaveMeter TM. Interferometric fiber end-face inspection systems for research, development and production.

P H Y L A B 1 : G E O M E T R I C O P T I C S

Two 2 MP orthogonal video microscopes equipped with double sided telecentric lenses and LED backlighting

Physics 309 Lab 3. where the small angle approximation has been used. This pattern has maxima at. Y Max. n L /d (2)

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

Physics 1202: Lecture 18 Today s Agenda

Signature Core Fiber Optic Cabling System

Textbook Reference: Glencoe Physics: Chapters 16-18

ksa MOS Ultra-Scan Performance Test Data

Homework Set 3 Due Thursday, 07/14

FPC connectors (0.2mm pitch) Back lock

Biology 105 Laboratory 1: Microscope

Transcription:

ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 12: Fiber optics SUMMARY: In this lab you will become familiar with procedures for working with fiber optics including cleaving, splicing and coupling. PRELAB: HOMEWORK PROBLEM 1: Pedrotti 3 10-3. HOMEWORK PROBLEM 2: Pedrotti 3 10-11. Basic loss calculations. HOMEWORK PROBLEM 3: Pedrotti 3 10-15. There are multiple sources of dispersion (pulse spreading) the modal dispersion in this example is one of the easiest to understand. c). Express the results of part b in units of ps (of differential delay) / km (of fiber length). DESIGN PROBLEM: You have a laser beam with 1 mm diameter. (a). Calculate the focal length of the lens needed to couple efficiently into single mode fiber (8.2 micron diameter) and multimode fiber (62.5 micron diameter). Assume that the available lens diameters are equal to the size of your input beam. (b). You observe less-than-perfect coupling to the fiber with your designs of (a). List one potential reason for the extra loss. TECHNICAL RESOURCES: TEXTBOOK: Pedrotti 3 chapter 10 LECTURE NOTES: Lecture 13, Fiber optics. EQUIPMENT AVAILABLE: 125 micron cladding diameter, 62.5 micron core diameter multi-mode fiber. 125 micron cladding diameter, 8.2 micron core diameter SMF-28 fiber. This is single mode at 1550 nm and thus will carry a small number of modes at 632 nm. Coating stripper tools of several varieties. High precision fiber cleaver, Furukawa fiber cutter and fiber splicer. A spatially-filtered, JDS Uniphase 1103P-3020 Helium Neon laser. The laser wavelength is 633 nm. Collimation and focusing lenses. A sheet polarizer. A Newport fiber coupling mount and bare-fiber adaptor. An optical power meter. LAB PROCEDURE: Version 1.2, 9/19/12 McLeod and Gopinath 1

Note: The steps below do not have to be performed in order, so you can start on later steps while waiting for access to the cleaver. Single-mode coupling is difficult, so you should probably leave that step for last. STEP 1: FIBER STRIPPING AND CLEAVING Optical fiber consists of a high index glass core where the light is guided, surrounded by a lower-index glass cladding. The typical outer diameter for that cladding is 125 microns. To protect the delicate glass, this cladding is typically surrounded by a 245 micron diameter polymer coating. Often, further protection is provided by an additional tight buffer of 900 micron diameter. Fiber optic cables and jumpers build out from this structure. Figure 1. Fiber optic cable structure and terminology. Prepare your work-space. You will be accidentally creating a number of ~1 long, 125 micron diameter slivers of glass. Another name for these is the world s most painful splinter. They particularly like to spring away from your tool and land, point up, in the seats of cloth chairs. This adds the adjective embarrassing to the description. So, work on a well-lit work-bench with no clutter (backpacks, coats, general junk) this will give you the best chance of finding errant shards. Clear all fabric chairs from the area. Before working, obtain several lengths of cellophane tape. The moment you create a fiber fragment, capture it on the sticky side of the tape. That means right on the tool if it is still laying there or on the bench or floor if it gets away. This is a real safety issue find and capture them all. Replace the tape as needed. Dispose of the full tape in the garbage. Step one in this process is to get access to the glass by removing the coating from a section of SMF-28 fiber. The tool for this looks and works much like a wire Version 1.2, 9/19/12 McLeod and Gopinath 2

stripper used to remove the insulator from wire, however it must be much more precise since the coating is quite thin and the glass is quite brittle. Even the smallest scratch of the glass cladding will cause the fiber to break you will do this multiple times before you get the hang of it. Try both kinds of strippers including the no-nick and the metal set that look just like wire strippers. Even though they look similar, don t ever use fiber strippers as wire strippers this immediately destroys the knives. Strip back about an inch if coating you may find that several small sections are easier to remove than one large one. VERY important: Use lens tissue and methanol to clean all residue of the coating from the exposed glass. The residue burns in the cleaver and fouls the splicer electrodes which cost thousands of dollars. Be sure to remove all of the coating. Unlike copper wire, the glass that makes up the functional portion of the fiber cannot be just cut with a sharp tool it will shatter. Instead, the glass is forced cleave in a flat plane perpendicular to the fiber axis. This process starts with a microscopic fracture or scratch, much that used to cut plate glass. The fiber is then bent, causing it to break. You want about 4 mm of exposed glass fiber beyond the end of the remaining coating. Remember to immediately capture the excess fragment on your tape. Inspect your cleave using the fiber microscope. You should see a perfectly flat cylinder of glass. If you observe scratches or the plane of the cleave is not flat, strip a new section of fiber and try again. Do this until you have two fiber ends that are both flat. Carefully place both fibers into the fusion splicer and lock them in position with the clamps, then start the machine. A video microscope in both the x and y planes will attempt to locate the fiber cores and automatically align them, then bring the two fibers together in z. Finally, an electrical arc is used to melt the glass, effectively making one fiber. The fuse region is extremely delicate and so is usually re-coated or protected in a special splint. The splicer will report its estimate of the coupling loss record this value. A good splice should have under 0.1 db loss. The loss relates to the xy offset by the formula 2 2 exp x x x 4.34 db 0 0 w w where w 0 is the radius of the fiber mode, about 4 microns. Calculate % loss and the offset for your splice. STEP 2: COUPLING INTO MULTI-MODE FIBER Collimate and focus the HeNe laser at ~0.1 NA. Following the procedures above, obtain 1 to 2 meters of multi-mode fiber from one of the reels and put good cleaves on both ends. Mount the fiber in the chuck on the fiber coupler and place the chuck in the mount at the focus of the HeNe. Lay the fiber on the table making a large, smooth loop and gently tape it down in several locations to keep it motionless and also to help you avoid accidentally snagging it. Place several tape hold-downs near the fiber chuck to serve as strain-relief for later steps. Tape the other end of the fiber to a post top and point it at a white screen. Hint: Fold over the end of each piece of tape as a handle so you can just grab and peel. At the end of the lab, there Version 1.2, 9/19/12 McLeod and Gopinath 3

should be zero tape left on the benches or tables. This is a pet peeve of the professor don t leave tape stuck to bench or optical table or we ll have a cleanup party at the end of the semester and you will use razor blades and acetone to get it all back off. Couple the HeNe into the fiber by observing the output on the screen. This should not be too difficult due to the large core size. Measure your efficiency with the power meter. Observe the pattern on the screen does it appear to be single mode? Estimate the NA of the fiber. Carefully untape the fiber loop, leaving the tape near the fiber chuck to minimize any displacement of the fiber in the chuck. Form the fiber into a loop and gradually decrease the radius. Observe the pattern on the screen and (in the dark) the fiber in the loop. Explain what is going on. Comment on how your observations would impact a) the minimum size of fibercoupled optical systems and b) the use of different modes of the fiber as independent communication channels. STEP 3: COUPLING INTO SINGLE-MODE FIBER Repeat step 2 using the SMF-28. This fiber is single mode in the 1550 nm telecommunications band but will carry several modes in the red. The core size is 8.2 microns, almost a factor of ten smaller than the multi-mode fiber. This alignment will thus be much more challenging. Place an iris in the collimated beam and observe the reflection of the focus from the glass face of the fiber. If the focus is exactly on the glass and normal to it, the Fresnel reflection will retrace the beam path and return through the aperture. Use this to get three degrees of freedom (z, and the two angles) correct. Then scan in x,y until you detect a gleam from the far end of the fiber Then optimize the coupling, much as you did for lab 1. You may have to remove your fingers from the micrometer at each step to avoid perturbing the mount by a few microns. Once you have become sufficiently frustrated, repeat the steps above. Compare the bend radius and observed light leakage to the multi-mode fiber and comment on what this implies about this fiber relative to the multi-mode one. Does this agree with the NA estimates of the two fibers? Version 1.2, 9/19/12 McLeod and Gopinath 4

Grading Expectations Lab Report 12: Fiber Optics (100 total points) Name Name and group members. Abstract (10 points). Introduction (10 points) Methods (35 points) 1. FIBER STRIPPING AND CLEAVING, 5 PTS a. Description of procedure (cleaver and splicer), 5 pts 2. COUPLING INTO MULTI-MODE FIBER, 15 PTS a. Diagram of setup, 5 pts b. Description of setup and measurement 10 pts i. Coupling, 4 pts ii. NA estimate, 3 pts iii. Bend radius, 3 pt 3. COUPLING INTO SINGLE MODE FIBER, 15 PTS a. Diagram of setup, 5 pts b. Description of setup and measurement, 10 pts Results and Analysis (35 points) 1. FIBER STRIPPING AND CLEAVING, 5 PTS a. Discussion of cleaving/splicing results, 2 pts b. Calculation of offset for splice (include equations), 3 pts 2. COUPLING INTO MULTI-MODE FIBER, 15 PTS a. Report of efficiency of coupling, and description of factors that impact it, 3 pts b. Picture/sketch of what saw on screen, 2 pts c. Estimate NA, 3 pts d. Report on mode profile vs bend radius (sketch or photo of results), 3pts e. Explanation of phenomena of (c). Comment on implications for size of communications systems and use of different modes as independent channels, 4 pts 3. COUPLING INTO SINGLE MODE FIBER, 15 PTS a. Report on coupling efficiency and how this compares with theory, 5 pts b. Estimate NA and compare with theory, 5 pts c. Comparison of bend radius and light leakage to multimode fiber results, 5 pts e. Conclusion (10 points) Summary of lab report f. References Include any references that you used. Version 1.2, 9/19/12 McLeod and Gopinath 5