HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Similar documents
CARRIER HOURLY ANALYSIS PROGRAM v5.0

HOURLY ANALYSIS PROGRAM 5.10

NEW FEATURES IN CARRIER BUILDING SYSTEM OPTIMIZER 1.40

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.90

CARRIER edesign SUITE NEWS

TRACE 3D Plus Getting Started - Load Design and Energy and Economics Examples L E T S G O B E YO N D. Trane.com/TRACE3DPlus

Introducing the Heat Wheel to the Data Center

Energy Engineering: Tools and Trends

TRACE 700 Learning Series Module 2: Navigation

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

DEDICATED HEAT RECOVERY UNIT (DHRC)

Data Center Energy Savings By the numbers

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Designing Ultra-Efficient Building Cooling Systems

Table of Contents. Executive Summary Site and Unit Background Chiller Chiller Appendix... 11

Variable Speed IPLV.36 kw/tr

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Air-Cooled Series R Chiller

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Carrier Electronic Catalog Customer Suite Version Release Sheet

New Wisconsin Energy Code: What it Means for Me?

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

IT Air Conditioning Units

Trailblazer AGZ-E air-cooled scroll chillers

ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

Saving Water and Operating Costs at NREL s HPC Data Center

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Ecotel Free Cool 5-15kW

equest Training equest Schematic Design Wizard

Chiller Replacement and System Strategy. Colin Berry Account Manager

MSYS 4480 AC Systems Winter 2015

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Reducing Energy Consumption with

What s on the Horizon for HVAC in Title ? Mark Hydeman, PE, Principal Taylor Engineering, LLC

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Efficiency of Data Center cooling

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Self-Contained Air Conditioning Systems

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Global Optimisation of Chiller Sequencing and Load Balancing Using Shuffled Complex Evolution

Cooling season full and part load performance evaluation of Variable Refrigerant Flow (VRF) system using an occupancy simulated research building

Total Modular Data Centre Solutions

CenterPoint Energy Retro-Commissioning Program Application

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

Identify the Right Applications

Committed to Energy Efficiency

Customer Suite Version Release Sheet

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

HVAC System Energy Savings Opportunities

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

where we are, where we could be, how we can get there. 12/14/2011

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Better Building Controls Through Simulation

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

The challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software

Commercial HVAC and Other Measures for 7P. Outline

ApacheHVAC User Guide part A: Overview and fundamentals

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Samuel Tepp Engineering Seminar Topics

ApacheHVAC User Guide Part A: Overview and Fundamentals

COIL SELECTION PROGRAM

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC. February 17, 2010 Revised

Welcome Association of Energy Engineers to the Microsoft Technology Center

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Sir Walter Scott may not have been thinking of building automation systems. How BACnet. Is Connecting At ASHRAE s Headquarters

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

The 2016 Legislation.

ASHRAE Standard 90.1

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Impact of Air Containment Systems

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Concord Hospital Infrastructure Upgrades Increased Energy and Operating Efficiencies with a Tangible Reduction in Operating Costs

Energy modeling of two office buildings with data center for green building design

interactive tool for 90.1 available on the ASHRAE website.

Retro-Commissioning Report

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

Existing Building Energy Saving

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012

Ten West 66 th Street Corporation Data Integrator Notes

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Ecoflair Air Economizers

What is the Carrier ChillerVu series counterflow application?

Integrated Environmental Solutions Virtual Environment Release Notes

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Optimiz Chilled January 25, 2013

Transcription:

HOURLY ANALYSIS PROGRAM v and v5.01 Carrier Software Systems Carrier Corporation Syracuse, New York Rev. November 3, 2016 Copyright 2016 Carrier Corporation, All Rights Reserved

Contents Chiller Features Air-Side Features Wizard Features Other Changes 2

5.01 CHILLER FEATURES 3

Updated Chiller Import Details: Carrier s Electronic Catalog (ECAT) can export performance data for aircooled chillers with heat recovery features. can now import and utilize this data in energy simulations. 5.01 Figures show input screens. 4

AIR-SIDE FEATURES 5

Variable Speed Rotary VRF Details: Added simulation performance curves for variable speed rotary compressor VRF condensing units. With this addition, now offers three types of performance models for VRF: variable speed rotary, variable speed scroll, and digital scroll. Figures show the detailed input screens. 6

Variable Speed Rotary VRF Details: Inputs specify capacity, EER, COP, compressor type, and controls. During energy simulation applies these inputs to the performance curves to create a scaled performance model for the VRF condensing unit. The model then calculates how efficiency changes each hour with changing operating conditions. Figures show the wizard screens. 7

ASHRAE Std. 62.1-2013 Details: ASHRAE Standard 62.1-2013 ventilation defaults has been added, as well as Ventilation Rate Procedure sizing calculations. 8

Ventilation Sizing Summary Report Details: New layout for terminal systems clarifies sizing of zone ventilation airflow and DOAS airflow: New table summarizes system ventilation requirements Zones now listed separately, with individual per-zone totals. This better reflects actual sizing calculation procedures. 9

DOAS Terminology Details: Updated terminology to consistently use Dedicated Outdoor Air System (or DOAS) throughout the program. 10

WIZARD FEATURES 11

Waterside Economizer for Air-Cooled Chiller Plants Details: This feature models a cooling tower used for direct cooling duty alongside air-cooled chillers, when ambient conditions allow. Integrated and non-integrated configurations are supported. This complements existing features for water-cooled chiller plants. 12

US Energy Information Administration (EIA) Rates Details: The Utility Rate Wizard has been updated with 2014 EIA rates for gas and electricity. (2014 data was the latest available at time of release). 13

Interoperability Among Wizards 1. Weather location automatically selects EIA utility rates (where available) 2. Building type automatically selects equipment operating schedule Automatic selections can be overridden 14

OTHER FEATURES 15

Import from Carrier Building System Optimizer Details: Projects created in Building System Optimizer (BSO) can now be loaded into. Once imported, full capabilities can be used. This facilitates scenarios where schematic design was done in BSO but further detailed design or analysis is required. 16

Export to Comma Separated Values (CSV) Files Details: CSV is a common file format compatible with spreadsheets such as Microsoft Excel and other software. Energy simulation results for air systems, plants, and buildings can now be output in this format. 17

Bugs / Corrections (v5.01) 5.01 The following problems were corrected: 1. Plant Simulations Air-cooled chillers imported from ECAT could show excess energy consumption when in water-cooled heat recovery mode during low-load conditions. 2. Publish to ECAT When publishing sizing results to ECAT an error occurred when the peak month for a cooling coil happened to be the winter / heating design condition. 3. Spaces Search & Replace Fixed problem preventing all choices from being listed for space usage type for projects using ASHRAE 62.1-2013. 4. General Eliminated occasional runtime error on computers with missing MS Sans Serif font. 5. General Fixed problem which prevented disabling the What s New screen. 18

Bugs / Corrections (v) The following problems were corrected: 1. Air System Inputs When the 90.1 Appendix G Fan kw option was selected for supply fan performance, the button to display the A-Factor Calculations input screen appeared in the wrong position on the screen, obscuring other inputs. 2. System Design Reports For an induction beam or active chilled beam system in which a zone contains multiple spaces, and in which the zone primary airflow is set by induction supply requirements rather than outdoor air ventilation requirement, the Ventilation Sizing Summary report showed incorrect Voz values for spaces in that zone. This was a cosmetic error. Calculation of ventilation airflow requirements for the system was correct. 3. Building Simulation I It was possible to create a complex electric rate with zero energy charge steps. If that electric rate was used in a building simulation an error message appeared. 4. Building Simulation II The unmet load hours shown on the LEED EAc1 report incorrectly included unmet loads for service hot water (SHW), but should only contain data for space conditioning. This only occurred for projects modeling a standalone SHW system. 5. Building Wizard When a wall, roof, or window assembly created in the detailed user interface was selected in the Building Wizard, the overall U-value was shown as zero. In addition, an error occurred when generating the Building Wizard input report. These were cosmetic errors; inputs were successfully transformed into spaces, assemblies and schedules for the detailed interface and were reliable for use in load calculations and energy simulations. 6. Utility Rate Wizard When price data for remote steam was entered, it was incorrectly assigned to the remote hot water meter in the building. 7. Reports Under specific conditions an Error 521: Unable to open clipboard error occurred when generating certain reports. 8. gbxml Import For a very specific set of conditions the gbxml Import feature linked the wrong window or door assembly to spaces. This only occurred when window names exceeded 30 characters, and the first 30 characters of each name matched other names. 9. Example Problem Results PDF Example problem results listed in the Example Problems Results PDF document did not match results produced by the v4.9 example problem. This PDF document is used by customers performing validation of the program. 19

QUESTIONS? If you have any questions about Carrier Hourly Analysis Program v5.01 please contact Carrier Software Systems at software.systems@carrier.utc.com Thank you! 20