Solar Pumping Inverter Version 2016 Automatic Hybrid Solar/AC /Battery Power input

Similar documents
SOLAR PUMPING INVERTER USER MANUAL

User Manual. Solar Inverter for Water Pump

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

NIR Moisture Analyzer KB-30

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

Smart Grid Tie Microinverter User Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

SOLARIMMERSION IV Advanced Installation Manual v1.9

22-60VDC Grid Tie Microinverter User Manual

Installation and Operation Manual SPC1

Pure sine wave inverter. Product Manual

VAT series controller and transmitter. Manual

Quick Start Installation and User Manual

FT-20 Fire Training Fog Machine User Manual English

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

FT-20 Fire Training Fog Machine User Manual English

0.01kV (0 to ±0.99 kv)

SCM030. MPPT Solar System Controller With. DC to DC Booster Input. Installation & Operating Instructions

GCI-5K INSTALLATION AND OPERATOR S MANUAL

V1.0. Showven Technologies Co.,Ltd.

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Three-Phase Solar Pump Controller 1.5 kw 380V User Manual

BRC SERIES 20kW High Voltage Power Supply

GCI-2G-W Single Phase Inverter

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Solis Single Phase Inverter

Smart Grid Tie Microinverter User Manual

ELV12 Series. Instruction Manual

Solar Pumping Inverter User Manual

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Solis Single Phase Inverter

RZ5/RZ5D/RZ6 Processor. Operator s Manual

Switched Mode Power Supply Operating manual PAP800

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product.

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Installation and Operation Manual DPC1

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

ZTE MOBILE HOTSPOT QUICK START GUIDE

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

XTM1250SA DIN rail three phase four wire LCD display energy meter

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

SBS-S SERIES DC LOAD BANK USER MANUAL Rev

USER MANUAL. Frequency Converter 15kVA 3x200V 400Hz Type AC/AC Frequency Converter

RXTH DUAL ROOM SENSOR / SWITCH

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

A1000 GSM ALARM DEVICE

-5K-2G. Solar PV Grid Tie Inverter. inverter. Installation and Operation Manual. 2013, Ningbo Ginlong Technologies Co., Ltd.

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment.

Important Safety Notice

RТTH DUAL ROOM SWITCH

Z-380 Fazer Machine User Manual English

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

Series Pressure Sensor Instruction Sheet

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

GS828-H. GPRS Data Logger

RZ2 BioAmp Processor. Operator s Manual

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

TABLET PC. Quick Start Guide. Model: TVE100 I

Installation and Operations Manual INVOLAR MAC250 Microinverter

User's Guide. Model W 3-in-1 Switching DC Power Supply

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

USER S MANUAL Linear Programmable DC Power Supply APS

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

PIEZO FEEDER CONTROLLER

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Model HM-535 Power Supply Installation and Service Instructions

Stage Fog Machine User Manual

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

TT /12b INSTALLATION INSTRUCTIONS. Introduction

ZTE MOBILE HOTSPOT QUICK START GUIDE

3700 SERIES USER MANUAL

FR-PU07 QUICK START MANUAL

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

Series Pressure Sensor Instruction Sheet

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

RXTP ROOM TEMPERATURE

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

User Manual. Cobia Flex R/F English - v2016.5a

User Guide. TP3016M Series Switching Mode DC Power Supply

Z-350 FAZER USER MANUAL

Thermoelectric Cooler Controller TED1000

Room Temperature Controller

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

ZEPHYR Compact Haze Machine

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

MyGenie TM 32 Thermal Block

Modbus Interface Module

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

MetaDolce MD3600 IP65 Multi-Data Capture Tablet Quick Manual. 1. Keys and Connectors

Transcription:

USER MANUAL VERSION 2016 VERSION V5.0 DATE Oct / 20 / 2015 PRODUCER LEO To ensure of your health, equipment and property, please read this chapter carefully before use the solar pumping inverter and act in compliance with the instructions. 1

1. SAFETY DEFINITION: Danger: It will cause serious injuries and even death while operating against the rules Storage Condition: NOTE Temperature Temperature 40 to +65. Humidity 5% to 90%, no condensation Storage in dry, dust free Do not store in the environment containing corrosive gas, liquid Installation: Danger FORBID to connect the switcher between the Ac output of inverter with the pump Wire is connected by professional person only. Each wire connect to the device must be wrapped with electrical tape for safety Prohibiting the installation location: direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid. Attention To ensure good convection cooling effect, the device must be installed Vertically The height of the device installation should be over 1.1m or more, and please establish the risk identified beside the device. The ambient temperature 20 +60, If Over 45, Please make sure well ventilated and the backside of inverter should be covered to make sure the air of fan is output from TOP of inverter. Relative humidity 15% +95%RH The device ONLY can be used to control the three phase AC asynchronous Pump and Resistor Heater. Attention If the output flow is small, please exchange the two line of U.V.W The equipment of the environmental temperature will directly influence the durability and reliability, make sure the environment to meet the above requirements for prolong the service life of the machine Maintance: 2

Danger Under any circumstances, without professional guidance, do not disassemble the machine or touch the internal parts Forbid to maintain the equipment when device is Power on 2. NAMING RULE Solar Pumping Inverter: HSPIL/H 2200 H/L A/B X X: Build In the Booster Circuit. A/B:Output Frequency A:50Hz B:60H H/L:AC Output Voltage, H:380/400/440V L:220/240V 2200: Rated Power of Inverter 2200W HSPIL/H:Company product code, Solar Pumping Inverter, L: Only Solar Power H: Hybrid AC/Battery/Solar Power Solar Pumping System Construction: 3

PARAMETERS Model Rated power (KW) Solar Panel Voltage (Voc Min-Max) Solar Panel Voltage (Vmp) Hybrid AC Power Hybrid Battery Power Voltage Solar Booster (Input Votlage 55-95V) Pump Voltage Pump Frequency Pump Power Y HSPIL/H750L 0.75 < 750W Solar Booster and Single Phase Hybrid AC power is AC 3Phase HSPIL/H1500L 1.5 200-450 300 220V, 312V alternative < 1500W 220/240V 50/60Hz HSPIL/H2200L 2.2 N < 2200W HSPIL/H750H 0.75 Y Solar Booster and < 750W Hybrid AC power is HSPIL/H1500H 1.5 alternative < 1500W HSPIL/H2200H 2.2 < 2200W HSPIL/H3700H 3.7 < 3700W HSPIL/H5500H 5.5 < 5500W HSPIL/H7500H 7.5 < 7500W HSPIL/H11KH 11 < 11KW 50 ~ 60Hz HSPIL/H15KH 15 < 15KW HSPIL/H18KH 18 400-780 500 Three Phase AC 3Phase 380/400/440V, 480V 380/400/440V 50/60Hz < 18KW HSPIL/H22KH 22 N < 22KW HSPILL/H30KH 30 < 30KW HSPIL/H37KH 37 < 37KW HSPIL/H45KH 45 < 45KW HSPIL/H55KH 55 < 55KW HSPIL/H75KH 75 < 75KW HSPIL/H100KH 100 < 100KW HSPIL/H150KH 150 < 150KW NOTE : Table 1 1.Solar Panel s Power configured to 1.2 ~ 2 times of pump s power, according to the pump s efficiency and sunshine of solar pumping system installed location. 2.Solar Booster support max power of pump is 750W. 3. Hybrid power automatic support 750W to 30KW, 37KW to 150KW by manual. 4

WIRING. Model Max Input Current Preesure Voltage of input wire Input wire diameter Output Current Pressure Voltage of output wire Output wire diameter HSPIL/H750L 4A 600V 2 x 2.5m m2 4.8A 500V 2.5m m2 HSPIL/H750H 16A 600V 2 x 2.5m m2 2.1A 500V 2.5m m2 HSPIL/H1500L 6.5A 600V 2 x 2.5m m2 9.2A 500V 2.5m m2 HSPIL/H1500H 35A 600V 2 x 2.5m m2 3.8A 500V 2.5m m2 HSPIL/H2200L 10A 600V 2 x 2.5m m2 11A 500V 2.5m m2 HSPIL/H2200H 8A 1KV 2 x 2.5m m2 7.2A 500V 2.5m m2 HSPIL/H3700H 11A 1KV 2 x 4m m2 10A 500V 2.5m m2 HSPIL/H5500H 17.5A 1KV 4 x 4m m2 13A 500V 2.5m m2 HSPIL/H7500H 22A 1KV 4 x 4m m2 18A 500V 2.5m m2 HSPIL/H11KH 31A 1KV 4 x 4m m2 24A 500V 4m m2 HSPIL/H15KH 40A 1KV 4 x 4m m2 30A 500V 4m m2 HSPIL/H18KH 48A 1KV 6 x 4m m2 39A 500V 6m m2 HSPIL/H22KH 58A 1KV 6 x 4m m2 45A 500V 6m m2 HSPIL/H30KH 79A 1KV 6 x 4m m2 60A 500V 10m m2 HSPIL/H37KH 96A 1KV 12x 4m m2 75A 500V 15m m2 HSPIL/H45KH 117A 1KV 12 x 4m m2 91A 500V 20m m2 HSPIL/H55KH 137A 1KV 12 x 4m m2 112A 500V 25m m2 HSPIL/H75KH 187A 1KV 50m m2 150A 500V 30m m2 HSPIL/H100KH 240A 1KV 65m m2 200A 500V 40m m2 Table 2 5

3. INSTRUCTIONS. 3.1 Socket Solar Pumping Inverter Version 2016 1 2 4 3 8 9 5 10 6 7 6

Solar Pumping Inverter Version 2016 11 12 11 Number 1 Description Parameters LCD Screen Display with 128*64px Cover 16*4 characters IP65 2 Keyboard Esc, Up,Down,Enter 3 Ac output four lines (3phase and ground line) Red/Yellow/Blue/Yellow_Green Color IP65 4 AC/Battery Input Four line(3phase and Ground Line) Red/Yellow/Blue/Yellow_Green Color IP65 5 Dc input Negative and Positive MC4 /IP68 6 Fan for wind cooling IP68 7 Communication RS485 /RS232 7

IP65 8 Well sensor IP65 9 Tank sensor IP65 10 Power On/ Off control Inverter Startup: The LED On Stop: The LED Off IP65 11 The hole for installation 8 10mm 12 The slide plate for keep cooling wind to be vertically 3.2 DC Input a. Please refer to the Table 1 and check the input voltage whether within the standard or not... Then input voltage can be measured by multi meter. For example:220v AC output,so the DC input voltage range is: 250V~450V b. To PV Panel to Input of pumping inverter can connect the breaker if needs. c. Please make sure the input negative and positive line wiring correcting 3.3 AC Input/Output FORBID to connect the switcher between the Ac output with pump AC Output to Pump Red Color Yellow Color Blue Color Yellow_Green Pump U Phase Pump V Phase Pump W Phase Ground NOTE: if the output flow of pump is too small, please try to exchange two wire of 3phase. 8

AC /Battery Input to solar pumping inverter Red Color Yellow Color Blue Color Yellow_Green AC U Phase AC V Phase AC W Phase Ground Battery + Battery Battery + N.C (positive) (Negative) (positive) 3.4 WELL and TANK SENSOR High Level Water Detect Middle Level Water Detect Picture 3 Low Level Water Detect Length wire of well and tank is 0.5M, each sensor have three wire, include High level of water detect, middle level of water detect, low level of water detect. For example of Well Connecting Method(Tank connect wire is the same): 1) The longest length of reserved wire is for well low level of water detect 2) The middle length of reserved wire is for well middle level of water detect 3) The shortest length of reserved wire is for well high level of water detect Remarks: The connection is not on basis of line color difference, according to the length of reserved line 9

3phase wire +1Ground wire of pump Tank/Well Sensor Pipe High Level H1 Water Middle Level H H2 Submersible Pump, socket of water Input Low level H3 Bottom of well Water Level detector (Stainless/Copper) Example: Total Height(H) of Well is 100meters, water deep (H1+H2+H3) is 90 meters H3: from bottom of well to the water input of pump is 10meters H2: 40meters H1: 40meters. Well/Tank wiring method Picture 4 10

3.5 LCD Type LCD Screen operation Diagram: PV Pump Inverter HSPIH5500H Run 13:26 02/11/15 Enter Into Setting Menu 0 0 0 0 Verify the PW Working Time Start Stop (H:M) Time: 0 :0 23:59 Solar Power Voltage: 540 (V) Current: 2 (A) Hybrid Active Solar: 5.1 (KW) AC: 2.2 (KW) Total: 7.3 (KW) AC Output 3Phase Freq: 50 (Hz) Current: 2 (A) System Setting 1. Working Time 2. Hybrid/Stop 3. Dry-Run Detect 4. Tank Sensor 5. Well Sensor 6. Output Freq 7. Output Voltage 8. Gprs Password 9. Time Calibrate 10. System PW Set 11. Factory Reset PV Low Power to Hybrid/Stop LE: 10 Hz In 5 M 20 M to Restart Dry-Run Setting Enable/Disable Parm Setting Ref LE Curt: 10A Tank Sensor Set Enable Disable StateNow: Enable Dry-Run Protect Enable Disable StateNow: Disable Dry-Run Protect By Soft @ 45Hz LE Current: 10 (A) Stop Time: 30 (M) Inverter State No Warning! No Error! Temp: 35. 0(Degree)) Well Sensor Set Enable Disable StateNow: Enable Water State Tank Empty Well Full AC Output Max 50 Frequency(Hz) Error History Error: 32 11:43 02/09/15 More Clear All AC Output Max Voltage Max 380V State Now: 380V Machine-ID 4015 MFD: 17/15 Gprs Control PW 8618688958696 0 0 0 0 Verify PW First System PW 0 0 0 0 Verify PW First Error History Error: 32 11:43 02/09/15 More Clear All Error History Error:32 11:43 02/09/15 More Clear All Error History Clear All Data? ESC / Enter More Clear All Time Calibrate (H:M M/D/Y) 20 : 25 2 / 11 / 15 Factory Reset Enter Back ESC Key to Back 11

Main Menu UP, Down Key for Change Menu PV Pump Inverter HSPIH5500H Run 13:26 02/11/15 Solar Power Voltage: 540 (V) Current: 2 (A) Enter Key for enter Setting Menu Line 1: Company Name Line2: Model Line3: Show System is Running or Stop 1.OFF (Gprs): Gprs control it to Stop 2.OFF (Time): Now is not within the working time of inverter 3.OFF (Low Power): Solar Low power to stop for protect the pump 4.OFF (Remote Com): RS485/232 control it to stop 5.OFF (Hybrid): Hybrid switching to stop 6. OFF (Tank): The water of Tank is full 7. OFF (Well): The water of well is empty 8. OFF (Dry Run): Dry run of pump, no water input 9. OFF (Igbt Ero): IGBT Error 10. OFF (Invt Ero): Inverter error, Over Temperature, 11. OFF (Low Voltag): DC input is low voltage Line 4: System Time NOTE: system time is important, as the working time of inverter is related with this. Please correct with local time. Input State Show the Input Voltage, Current,Power of Solar Panel Hybrid Active Solar: 5.1 (KW) AC: 2.2 (KW) Total: 7.3 (KW) AC Output 3Phase Freq: 50 (Hz) Current: 2 (A) Hybrid Active/Inactive Hybrid Power is active or inactive, show the power of Solar or AC Output State Show the Output frequency, Current of AC to the pump 12

Inverter State No Warning! No Error! Temp: 35. 0(Degree)) Inverter State Show the Warring, Error and Temperature of Solar Pumping inverter Tank /Well s water status Display Water State Tank Empty Well Full Error History Error: 32 11:43 02/09/15 More Clear All Machine-ID 4015 MFD: 17/15 Show the water of Tank and Well status. If the water of tank is full or water of well is empty, will automatic stop running and show the status Error History For inquiry the Error flag history Press the Enter key to enter this menu, then UP / Down to select the command for inquiry more record or clear the history. Note: if current cursor is on More, press Enter key to confirm view more records, then UP / Down key to change the records number. Machine ID The Unique Serial id of inverter MFD: manufacture Date Enter Into Setting Menu 0 0 0 0 Verify the PW Verify the Password to Enter the Setting Menu Original is: 0000 System Setting 1. Working Time 2. Hybrid/Stop 3. Dry-Run Detect 4. Tank Sensor 5. Well Sensor 6. Output Freq 7. Output Voltage 8. Gprs Password 9. Time Calibrate 10. System PW Set 11. Factory Reset System Setting UP / Down to change Menu Item Working Time Start Stop (H:M) Time: 0 :0 23:59 Working Time For Inverter working time set. If the system time within this setting then work, or else standby. 13

Solar Low Power to Hybrid/Stop LE: 10 Hz In 5 M 20 M to Restart Solar Low Power to Hybrid/Stop Solar Panel output power is low to supplement by AC power or Stop 1. Solar Input / AC Not input a. Inverter output freq below 10Hz within 5 Minutes, stop output,and inverter restart after 20minutes. b. switching to ac power automatic once the ac input active after inverter stoped by low power. 2. Solar Not input / AC input a. Inverter only using ac power b. Detecting the solar power is enough to running 10Hz when solar power active, if ok, then switching to solar power. Otherwise using ac power always,and repeat step 2.b 3. Solar Input/ AC Input a. Startup by Solar Power, if it s not enough to running to 10Hz within 2minutes, switching to AC and SOLAR/AC hybrid b. SOLAR/AC Hybrid power running to 20 minutes, switching to solar Power again and repeat step 3.a and step 3.b Dry-Run Setting Enable/Disable Parm Setting Ref LE Curt: 10A Dry-Run Protect Enable Disable StateNow: Disable Dry-Run Protect By Soft @ 45Hz LE Current: 10 (A) Stop Time: 30 (M) Dry Run Detect Dry Run of pump(water level of well), detect by software. when inverter run to 45Hz or higher, it detect the current of pump, Automatic Stop run once less than the set parameters of Current, after stop time finished,restart again. NOTE: If the well sensor input and Enable Well sensor detect the water level,this function is disable Ref LE Curt: Current value is 2/3 times of rated current of pump. The inverter will give the reference value once the pump running to 40Hz or more with water 14

Tank Sensor Set Enable Disable StateNow: Enable Tank /Well Sensor Set To Enable/Disable the sensor working. Well Sensor Set Enable Disable StateNow: Enable AC Output Max 50 Frequency(Hz) AC Output Max Voltage Max 380V State Now: 380V Gprs Control PW 8618688958696 0 0 0 0 Verify PW First AC Max Output Frequency Set the Max output Frequency, Range from 50 to 60Hz NOTE: Please confirm it with your pump s parameter, if the pump is 50Hz, but the setting is Max 60Hz, then pump will be damaged! Max Output Voltage of AC Set the Max output Voltage. Invalid for inverter that 220V output. NOTE: Please confirm your pump s parameter, if the pump is 380V, but the setting is Max 440V, then pump will be broken! GPRS Control Password The Password is used for Command Verification that send by GPRS Time Calibrate (H:M M/D/Y) 20 : 25 2 / 11 / 15 System Time Calibrate System Time System PW 0 0 0 0 Verify PW First Factory Reset Enter Back ESC Key to Back System Password The password is for enter the setting menu Factory Reset For Reset all of setting to default value. 3.6 POWER ON/OFF AND FLOW CONTROL 15

Startup: Press Down The lighting is On Shut Down: Press Up The lighting is Off 3.7 GPRS Control(Optional function ) GPRS MODULE ANTENNA CONNECTOR GPRS MODULE SPECIFICATIONS Working Voltage 5~28V Working Current Max 1200mA, Normal 10~100mA Working Temperature 40~80 Storage Temperature 40~85 Storage humidity Working Frequency 5%~95%RH 850/900/1800/1900MHz Communication socket Waterproof RS485/RS232 N. IP20 16

3.7.1 Command Specification CONTROL Startup control Stop control Command ****,invt on. ****,invt off. Inquiry the status of solar pumping inverter working ****,invt state. Feed back by Solar pumping inverter: Inverter stop: Show stop reason Inverter working: 1. Solar input voltage 2. solar input current 3. solar input power 4. Hybrid active/inactive Inquiry 5. Hybrid power of ac or battery 6. Inverter current frequency 7. Inverter temperature 8. Inverter output current Inquiry setting parameters ****,invt parameters. Feed back by solar pumping inverter: 1. Inverter output max voltage setting value 2. Inverter output max frequency setting value 3. Inverter working time setting value 4. Inverter Hybrid/stop setting value 5. Inverter dry run setting value 6. Inverter tank and well sensor setting value Notification Inverter Automatic note the master Solar pumping inverter automatic send the message to master When there is error or warning **** is the password that you setting, Original is 0000, Super password is:9590 The character, and. is necessary. 17

3.7.2 Command Example Solar Pumping Inverter Version 2016 SIM Card Number Solar Pumping Inverter Feed Back Command Control/Inquiry Note: 1. Please make a call to the GPRS before sending the command sms, and make sure the signal of GPRS module is ok 2. The Solar pumping inverter feedback message is about 3 5 seconds, the time is depend on the server of local. 3. The head of feedback message is the inverter model and Serial ID. 18

4. Error Flag Display Solar Pumping Inverter Version 2016 Error Flag Phase Lost Over temperature Over current short circuit Solar power input over voltage 2 1 4 1 6 1 1 8 1 10 1 1 12 1 1 14 1 1 1 32 1 34 1 1 36 1 1 38 1 1 1 40 1 1 42 1 1 1 44 1 1 1 46 1 1 1 1 NOTE : a. over temperature. 1 express the status is true, for example : Error Flag is 8 indicate system inverter is 5. CASE 3Phase 380V 2HP AC pump solar pumping system: AC Pump Solar Panel Solar Pumping Inverter 2HP 1500W 3phase 380V Voc 46V Vmp 39V 310W/pcs HSPL1500HA Input Voltage 55~95V PV Connection: Total 6pcs use 2pcs in series to a group Three Group in Parallel Total Voc is 92V, Vmp 78V. Total Watt is 1860W 19

NOTE: As the low power of pump efficiency is low, will ask more power for input, please use 4Groups. 6. PACKAGING Inverter: 1pcs DC Input Connector: 2 12pcs according to the Table 2 AC/Battery Input connector: 1pcs Tank Sensor: 1pcs Well Sensor: 1pcs AC Output Connector: 1pcs User Manual: 1pcs 7. QUALITY WARRANTY In order to protect your interests, to solve your any menace from the "rear" except! The company provides 2 YEAR of warranty of quality service for you. Please provide machine failure photos or video and the ID of machine, then send to our technical department to analysis, we will reply within 24 hours. 20

Machine Label The following situation does not belong to the quality warranty: the user to alter the serial number and machine; quality warranty label tag; use environment does not meet the conditions of using. Product be repaired or disassembled without our authorization. The following situation not free fee, the specific charging standard according the device (material cost extra): both in or out of the warranty period: irresistible natural forces such as earthquake, fire damage caused by improper use; fault; machine water damage. 21