Contents. Volume 5 Motor Control and Protection CA E December

Similar documents
Catalog Number A, up to two ACs max (F-, G-Frame) Number of Poles. Rating (Frame) (D-Frame) 400 (E-Frame)

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

8.2 R5 Series (UL 508) Non-Fusible 16 80A. 8.4 MTS Manual Transfer/Double Throw Switches

R9 Series Non-Fusible A Compact Page 47 Page 49 Page 51. R9 Series. Page 53 Page 58 Page 59 IEC EN

Complete UL/CSA Disconnect Switch Kits

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches

Contents. Volume 8 Sensing Solutions CA E February

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SIRCO Load break switches for power distribution from 125 to 5000 A

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

UL 98 Fusible Disconnect Switches

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Miniature Circuit Breakers and Supplementary Protectors. Contents

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

The safest way to switch power on and off in your industrial control panels.

References. References. Rating (A) Référence

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Manual Motor Control Switches and Disconnects

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

MOTOR PROTECTION CIRCUIT BREAKERS

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

60103 Circuit Breaker

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

194E FA 32 E P11 P11 6

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Circuit Breakers Type CTI 25M, CTI 45MB

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

78 Series Electromechanical Relay Selection Guide

194E FA 32 E P11 P11 6

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Safety switches for hinged doors

CS7 Industrial Control Relays

FUSERBLOC from 30 to 800 A

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

TeSys IEC Contactors and Overload Relays

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Motor protection circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Type S801, soft starters

Limit Switches E47 Precision Switches

C E R T I F I C A T E O F C O M P L I A N C E

Time Delay Values (E-Series)

WMS SUPPLEMENTARY PROTECTORS

Introduction Circuit Protection

1492-SP Supplementary Protectors

CS8 Industrial Control Relays

Motor protection relays

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CERTIFICATE OF COMPLIANCE

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

M C. Ex d M-0... control, monitoring and signalling devices

Contents. Volume 8 Sensing Solutions CA E April

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

Magnetically Actuated Safety Interlock Switches

For our complete product offering, see Volume 7 Motor Controls, Logic and Connectivity, CA E and PG E.

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Disconnect Switches. Safe Switching and Disconnecting

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Safety switches with separate actuator

Position switches FD series

MOTOR & CIRCUIT PROTECTION

Large Frame IEC Contactors

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Mini Contactors & Overloads

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

920 Remote Control (RC) Switches

3RV1 Circuit-Breakers

SWITCH DISCONNECTORS 11

Square D General Purpose Relays

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Allen-Bradley Bulletin 100 Contactors

E-Series General Specifications

the Santon FCS-type switch Disconnect Superior Switch Solutions

Selection Guide. Control Circuit and Load Protection

CERTIFICATE OF COMPLIANCE

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Quick Start Guide TS A

Selection Guide. Control Circuit and Load Protection

Transcription:

Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection.............................. 678 Accessories................................... 679 Technical Data and Specifications.................. 681 Dimensions................................... 682 Product Description R9 Series (UL 98 listed) non-fusible disconnects are heavy-duty manual transfer switches, they transfer load manually between two low voltage circuits and provide safety disconnection. These switches are extremely durable and are tested and approved for use in the most demanding applications as resistive load or total system applications. Three load break positions (I, 0, II) On load switching Direct or external handle 480 Vac total system 600 Vac resistive load Standards and Certifications UL 98, culus, File E222859 UL 1008 (2011) CSA 22.2 No. 4, File 217736 IEC 60947-3 EN 60947-3 Product Identification External front handle Direct handle Shaft extension for external handle Pre-break ACs (standard on 600 1200A) Terminal Screen Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com 677

.4 Rotary Disconnects Product Selection Direct Operation UL 98 Standard Ampere Rating Notes Number of Poles Switch Body Only Direct Handle (Black) External Three- Position Handle (Choose one) 100 3 RMTS3100U DHMTSSL Size 2, Black 4 RMTS4100U I 0 II Type 4/4X 200 3 RMTS3200U PHB2N4X 4 RMTS4200U Size 2, Red I 0 II Type 4/4X PHR2N4X 400 3 RMTS00U Size 3, Black 4 RMTS4400U I 0 II Type 4/4X PHB3N4X Size 3, Red I 0 II Type 4/4X PHR3N4X 600 3 RMTS3600U DHMTSDL Size 4, Black 4 RMTS4600U I 0 II Type 4/4X PHB4N4X All ratings, 100 1200A, are UL 98 listed. Switches are to be UL 1008 listed in 2011. Line or load (top or bottom); for both line and load, order two kits. Low level auxiliary contact gold plated for minimal resistance for PLC applications. Shaft Extensions for External Handle In (mm) (Choose one) 7.90 (200.6) SF200PH10X10 12.60 (320.0) SF320PH10X10 15.70 (398.8) SF400PH10X10 7.90 (200.6) SF200PH15X12 12.60 (320.0) SF320PH15X12 15.70 (398.8) SF400PH15X12 Bridging Bars BB200 BB200 BB400 BB400 BB600 BB600 Size 4, Red 800 3 RMTS3800U DHMTSDLM I 0 II Type 4/4X BB1200 4 RMTS4800U PHR4N4X 1200 3 RMTS31200U 4 RMTS41200U External Operation + + + Switch body + Direct handle Switch body + Shaft + External handle BB1200 Auxiliary Contacts NO/NC AC1NONCMTS400 Low level AC1NONCMTS400LL NO/NC contact standard Terminal Screens TS3MTS200TB TS4MTS200TB TS3MTS400TB TS4MTS400TB TS3MTS600 TS4MTS600 TS3MTS1200 TS4MTS1200 678 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com

Rotary Disconnects.4 Accessories PH2 and PH3 Type PH4 Type Direct Handle Ampere Rating Handle Color Handle Type Catalog Number 100 400 Black Single lever DHMTSSL 600 Black Double lever DHMTSDL 800 1200 Black Double lever DHMTSDLM External Handle Description Ampere Rating Handle Type Handle Color NEMA Type The handle locking function prevents the user from opening the door of the enclosure when the switch is in the "ON" position. Opening the door when the switch is in the "ON" position is possible by defeating the locking function with the use of a tool (authorized persons only). The locking function is restored when the door is once again closed. Shaft Extension Ampere Rating Lockable in the 3 Positions Catalog Number 100 200 PH2 Black 4, 4X Yes PHB2N4X 100 200 PH2 Red/Yellow 4, 4X Yes PHR2N4X 400 PH3 Black 4, 4X Yes PHB3N4X 400 PH3 Red/Yellow 4, 4X Yes PHR3N4X 600 1200 PH4 Black 4, 4X Yes PHB4N4X 600 1200 PH4 Red/Yellow 4, 4X Yes PHR4N4X Handle Type Length In (mm) Catalog Number 100 800 PH1 7.90 (200.6) SF200PH10X10 125 800 PH1 12.60 (320.0) SF320PH10X10 100 200 PH2 15.70 (398.8) SF400PH10X10 630 1200 PH2, PH3 7.90 (200.6) SF200PH15X12 600 1200 PH2, PH3 12.60 (320.0) SF320PH15X12 400 1200 PH2, PH3 15.70 (398.8) SF400PH15X12 800 1200 V1 12.60 (320.0) SF320V1 800 1200 V1 15.70 (398.8) SF400V1 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com 679

.4 Rotary Disconnects Bridging Bars Description Ampere Rating Number of Bridging Bars Catalog Number Creation of a common point, above or below the switch, between positions I and II. Terminals Protection Screen Mounting Spacers Auxiliary Contacts Line and Load Terminal Lugs Note Gold plated for minimal resistance for PLC applications. 100 200 3 BB200 100 200 4 BB200 400 3 BB400 400 4 BB400 600 3 BB600 600 4 BB600 800 1200 3 BB1200 800 1200 4 BB1200 Description Ampere Rating Number of Poles Catalog Number Top or bottom (line or load) protection against direct contacts with terminal or connecting parts. 100 200 3 TS3MTS200TB 100 200 4 TS4MTS200TB 400 3 TS3MTS400TB 400 4 TS4MTS400TB 600 6 TS3MTS600 600 4 TS4MTS600 800 1200 3 TS3MTS1200 800 1200 4 TS4MTS1200 Description Ampere Rating Number of Poles Catalog Number Raises the device s terminals 10 mm away from the bottom of the enclosure or frame on which the device is mounted. 100 400 1 set of 2 spacers MSP400 Description Ampere Rating Contacts(s) Catalog Number Early-break/same-make and signalization per position 1 and 2. Electrical characteristics: A300. Description Connection of bare copper cables onto the terminals (without spade lugs). Ampere Rating 100 400 1NO/NC per position 1 and 2 AC1NONCMTS400 100 400 1NO/NC per position 1 and 2 low level AC1NONCMTS400LL 600 1200 1NO/NC per position 1 and 2 Standard Connection Type Number of Poles Number of Cables/Lug Lugs per Kit Cable Type Catalog Number 100 200 6 300 kcmil 3 1 3 Cu/Al LK3R9DL 100 200 6 300 kcmil 4 1 4 Cu/Al LK4R9DL 400 4 600 kcmil 3 1 3 Cu/Al LK3R9EM 400 4 600 kcmil 4 1 4 Cu/Al LK4R9EM 600 2x (#2 600 kcmil) 3 2 3 Cu/Al LK3R9FN 600 2x (#2 600 kcmil) 4 2 4 Cu/Al LK4R9FN 800 1200 2x (#2 600 kcmil) 3 2 6 Cu/Al LK6R9G 800 1200 2x (#2 600 kcmil) 4 2 8 Cu/Al LK8R9G 680 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com

Rotary Disconnects.4 Technical Data and Specifications UL 1008 Characteristics Description 100A 200A 400A 600A 800A 1200A Operation voltage 600 600 600 600 600 600 Short-circuit rating at 600 Vac (ka) 100 100 65 100 100 100 Type of fuse J J J L L L Maximum fuse rating (A) 200 400 600 800 1000 1600 Short-circuit rating with circuit breaker (ka/ms) 10/25 10/25 14/50 35/50 35/50 35/50 Operational Power/Current Maximum Operational Three-Phase 240 Vac total system (A) 100 100 250 400 700 700 240 Vac resistive load (A) 100 200 400 600 800 1200 480 Vac total system (A) 100 100 125 350 600 600 480 Vac resistive load (A) 100 200 400 600 800 1200 600 Vac resistive load (A) 100 200 400 400 800 1200 Mechanical Endurance Endurance (number of operating cycles) 6050 6050 6050 6050 3550 3550 Connection Terminals Minimum connection section/awg #6 #6 #4/2 x #6 2x #2 4x #2 4x #2 Maximum connection section/awg 300 kcmil 300 kcmil 600 kcmil/2x 350 kcmil 2x 600 kcmil 4x 600 kcmil 4x 600 kcmil UL 98/CSA 22.2 No. 4 Characteristics Description 100A 200A 400A 600A 800A 1200A Short-circuit rating at 600 Vac (ka) 200 200 200 200 100 100 Type of fuse J J J J L L Maximum fuse rating (A) 100 200 400 600 800 1200 Maximum Motor, hp/fla Three-Phase Motor Maximum 220 240 Vac 30/80 75/192 125/312 200/480 200/480 200/480 440 480 Vac 75/96 180/180 250/302 400/477 500/590 500/590 600 Vac 100/99 200/192 350/336 350/336 500/472 500/472 Maximum Motor Power, hp/dc FLA Motor Maximum 125 Vdc 7.5/58 15/112 20/148 20/148 250 Vdc 20/72 40/140 50/173 50/173 Mechanical Characteristics Endurance (number of operating cycles) 10,000 8000 6000 6000 3500 3500 Operating torque (lbs.in/nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 442.5/50 442.5/50 Auxiliary Contacts Electrical characteristics A300 A300 A300 A300 A300 A300 Notes Short-circuit rating achieved when used with respective fuse type and maximum fuse rating. Only UL 98 listed. For UL 1008 availability, contact Eaton. Two-pole in series. Three-pole in series. Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com 681

.4 Rotary Disconnects Dimensions Approximate Dimensions in Inches (mm) 100 to 200A 400A 6.41 (162.8) 5.19 (131.8) 6.77 (172.0) 9.41 (239.0) 10.90 (277.0) 7.48 (190.0) 1.53 (38.9) 0.41 (10.4) 5.51 (140.0) 4.29 (109.0) 5.51 (140.0) 2.04 (51.8) 0.41 (10.4) 6.53 (165.9) 1.18 (30.0) 0.53 (13.5) 0.29 (7.4) 8.26 (209.8) 8.26 (209.8) 0.98 (24.9) View A View B 0.29 (7.4) 0.49 (12.4) View A Ø0.43 Ø(11.0) Ø0.35 Ø(9.0) Ø0.27 Ø(6.9) 1.38 (35.1) View B Ø0.35 Ø(9.0) Ø0.27 Ø(6.9) 6.30 (160) Ø0.43 Ø(11.0) Fix 6.30 Fix 8.26 (160.0) (210.0) B A A 9.64 (245.0) 1.97 (50.0) Fix 8.26 (210.0) B 11.41 (290.0) 1.37 (.8) Fix 10.63 (270.0) 2.56 (65.0) 11.85 14.21 (301.0) (361.0) 2.67 (67.8) 5.31 (1.9) 1.37 (.8) 3.85 (97.8) 7.67 (194.8) 10.23 (259.8) 682 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com

Rotary Disconnects.4 Approximate Dimensions in Inches (mm) 600A 800 to 1200A 14.56 (369.8) 13.66 (7.0) 14.56 (369.8) 9.98 (253.5) 9.98 (253.5) 13.66 (7.0) 2.61 (66.3) 9.09 (230.9) 9.09 (230.9) 2.65 (67.3) 8.30 (210.8) 8.03 (204.0) 8.30 (210.8) 0.82 (20.8) 1.12 (28.4) 0.82 (20.8) Ø0.41 Ø(10.5) 1.02 (25.9) 1.96 (49.8) 0.98 (24.9) View A View A 1.49 (37.8) 3.54 (89.9) Ø0.41 Ø(10.5) 1.49 (37.8) 1.02 (25.9) Fix 10.04 (255.0) A 15.19 (386.0) Fix 13.66 (7.0) 4.72 (119.9) A Fix 13.18 (335.0) 3.15 (80.0) 15.19 (386.0) 18. (466.0) Fix 18.38 (467.0) 18. (466.0) 2.02 (51.3) 4.92 (125.0) 9.84 (249.9) 13.38 (339.9) 2.02 (51.3) 4.92 (125.0) 9.84 (249.9) 11. (288.0) Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com 683

.4 Rotary Disconnects Approximate Dimensions in Inches (mm) Terminal Lugs 100 200A 400A 600 1200A 1.52 (38.6) 100 200A PH2 Type Direction of Operation Door Drilling Template Ø3.07 (Ø78.0) 400A 1.00 (25.4) 0.45 (Ø11.4) 2.80 1.30 (71.5) (35.0) 1.12 (28.4) 1.80 (46.0) 0.44 (11.13) Ø 0.40 (Ø10.16) Ø 4.70 (Ø119.38) PH3 Type Direction of Operation Door Drilling Template Ø78 (Ø1981.2) 1.77 (45.0) 4.92 (125.0) 210 (53.0) 61.00 (1549.4) I II I II 90 90 90 90 0 0 0.63 (15.9) Ø D 3.15 (80.0) 0.55 (14.0) 0.55 (14.0) Ø D 0.55 (14.0) 0.55 (14.0) 4 Ø 0.27 4 Ø 7.0 1.49 (37.8) 0.40 (Ø10.2) 2.87 (72.9) 0.79 (20.0) 0.79 (20.0) 0.79 (20.0) 0.79 (20.0) 4 Ø 0.27 4 Ø 7.0 684 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com

Rotary Disconnects.4 Approximate Dimensions in Inches (mm) 600 1200A PH4 Type Direction of Operation Door Drilling Template Ø3.07 (Ø78.0) 2.36 (60.0) 13.77 (350.0) II I 90 90 0 0.79 (20.0) Ø D 0.79 (20.0) 4 Ø 7 (4 Ø 7) 0.55 (14.0) 0.55 (14.0) Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com 685

.4 Rotary Disconnects 686 Volume 5 Motor Control and Protection CA08100006E December 2010 www.eaton.com

Index A above, 4 AC, 2, 4 Accessories, 1, 3 achieved, 5 ACs, 1 again, 3 Al, 4 All, 2 Ampere, 3-4 and, 1-10 applications, 1-2, 4 approved, 1 Approximate, 7-9 are, 1-2 as, 1 at, 1-10 authorized, 3 Auxiliary, 2, 4-5 auxiliary, 2 availability, 5 away, 4 AWG, 5 B bare, 4 Bars, 2, 4 BarsDescription, 4 BB, 2, 4 be, 2 below, 4 between, 1, 4 Black, 2-3 Body, 2 body, 2 both, 2 bottom, 2, 4 break, 1, 4 breaker, 5 Bridging, 2, 4 by, 3 C CA, 1-10 Cable, 4 Cables, 4 cables, 4 call, 1-10 Catalog, 3-4

Index cation, 1 Certifications, 1 Characteristics, 5 characteristics, 4-5 Choose, 2 circuit, 5 circuits, 1 closed, 3 Color, 3 com, 1-10 common, 4 connecting, 4 Connection, 4-5 connection, 5 contact, 2, 5 Contacts, 2, 4-5 contacts, 4 Contents, 1 Control, 1-10 copper, 4 Creation, 4 CSA, 1, 5 Cu, 4 culus, 1 Current, 5 cycles, 5 D Data, 1, 5 DC, 5 December, 1-10 defeating, 3 Delivery, 1-10 demanding, 1 Description, 1, 3-5 device, 4 DHMTSDL, 2-3 DHMTSDLM, 2-3 DHMTSSL, 2-3 Dimensions, 1, 6-9 DimensionsApproximate, 6 Direct, 1-3 direct, 4 Direction, 8-9 disconnection, 1 Disconnects, 1-10 disconnects, 1 DL, 4 Door, 8-9 door, 3 Double, 3 Drilling, 8-9 durable, 1 duty, 1 E Early, 4 Eaton, 5 eaton, 1-10 Electrical, 4-5 EM, 4 EN, 1 enclosure, 3-4 Endurance, 5 Extension, 3 extension, 1 Extensions, 2 External, 1-3 external, 1 extremely, 1 F File, 1 Fix, 6-7 FLA, 5 FN, 4 For, 1-10 for, 1-2, 4 frame, 4 from, 3-4 front, 1 function, 3 fuse, 5 fusible, 1

Index G Gold, 4 gold, 2 H Handle, 2-3 handle, 1-3 HandleAmpere, 2 heavy, 1 hp, 5 I Identifi, 1 IEC, 1 II, 1-2, 4, 8-9 Immediate, 1-10 In, 2-3 in, 1-3, 5-9 Inches, 6-9 is, 3-4 K ka, 5 kcmil, 4-5 Kit, 4 kits, 2 KMParts, 1-10 L lbs, 5 Length, 3 level, 2, 4 lever, 3 Line, 2, 4 line, 2, 4 listed, 1-2, 5 LK, 4 LL, 2, 4 Load, 4 load, 1-2, 4-5 Lockable, 3 locking, 3 Low, 2 low, 1, 4 Lug, 4 Lugs, 4, 8 lugs, 4 M make, 4 Manual, 1-10 manual, 1 manually, 1 Maximum, 5 maximum, 5 Mechanical, 5 minimal, 2, 4 Minimum, 5 mm, 2-4, 6-9 most, 1 Motor, 1-10 mounted, 4 Mounting, 4 ms, 5 MSP, 4 MTS, 2, 4

Index N NC, 2, 4 NEMA, 3 Nm, 5 NO, 2, 4 No, 1, 5 non, 1 NONCMTS, 2, 4 Note, 4 Notes, 2, 5 Number, 2-4 number, 5 O of, 2-5, 8-9 ON, 3 On, 1 on, 1, 4 once, 3 one, 2 Only, 2, 5 only, 3 onto, 4 Opening, 3 opening, 3 Operating, 5 operating, 5 Operation, 2, 5, 8-9 Operational, 5 or, 1-10 order, 2 Phase, 5 PHB, 2-3 PHR, 2-3 plated, 2, 4 PLC, 2, 4 point, 4 pole, 5 Poles, 2, 4 Position, 2 position, 3-4 Positions, 3 positions, 1, 4 possible, 3 Power, 5 Pre, 1 prevents, 3 Product, 1-2 Protection, 1-10 protection, 4 provide, 1 PSF, 2 R Raises, 4 Rating, 2-4 rating, 5 ratings, 2 Red, 2-3 RedI, 2 resistance, 2, 4 resistive, 1, 5 respective, 5 restored, 3 RMTS, 2 Rotary, 1-10 P Page, 1 parts, 4 per, 4 persons, 3 PH, 2-3, 8-9 S safety, 1 same, 4 Screen, 1, 4 Screens, 2 section, 5

Index Selection, 1-2 Series, 1 series, 5 set, 4 SF, 2-3 Shaft, 1-3 Short, 5 signalization, 4 Single, 3 Size, 2 Spacers, 4 spacers, 4 spade, 4 Specifications, 1, 5 Standard, 2, 4 standard, 1-2 Standards, 1 Support, 1-10 Switch, 2 switch, 3-4 Switches, 1-10 switches, 1 switching, 1 system, 1, 5 T TB, 2, 4 TBagainst, 4 TBType, 2 Tech, 1-10 Technical, 1, 5 Template, 8-9 Terminal, 1-2, 4, 8 terminal, 4 Terminals, 4-5 terminals, 4 tested, 1 The, 3 the, 1, 3-4 These, 1 they, 1 Three, 1-2, 5 to, 2, 6-7 tool, 3 Top, 4 top, 2 torque, 5 total, 1, 5 Transfer, 1-10 transfer, 1 TS, 2, 4 Two, 5 two, 1-2 Type, 2-5, 8 type, 5 U UL, 1-2, 5 use, 1, 3 used, 5 user, 3 V Vac, 1, 5 Vdc, 5 View, 6-7 voltage, 1, 5 Volume, 1-10 W when, 3, 5 which, 4 with, 3-5 without, 4 www, 1-10

Index Y Yellow, 3 Yes, 3 ype, 5, 9