D12 Series DIN Rail High Power Fiber Optic Sensor

Similar documents
DF-G2 High Speed Expert Dual Display Small Object Counter

SLM Series Slot Sensors

D11 Expert Series: Visible Green, Blue or White LED Light Source

D11 Series: Visible Green, Blue or White LED Light Source

DF-G2 High Speed Expert Dual Display Small Object Counter

D11 Expert Series 5V dc Models

QAL50 Series Analog Line Sensor

WORLD-BEAM Q12 Series Sensors

ivu TG Gen2 Image Sensor with Integrated Display

EZ-LIGHT SP Series Signal Light

MINI-BEAM SM312F. MINI-BEAM Glass Fiber Optic. Output Type E X C E S S. A I N 1.01 m.033 ft. Bipolar NPN/PNP V dc E X.

M18-3 Nickel-Plated Brass 18 mm Barrel Sensors

K50 Series Pick-to-Light

MINI-BEAM SM2A312F. MINI-BEAM Glass Fiber Optic. Output Type E X C 100 E S S. A I N 1.01 m.033 ft. SPST Solid-state 2-wire E X E S S

LED..O..M Series Diffused On-Axis Lights

ivu Plus TG Image Sensor with Integrated Display

Q08 Series Opposed-Mode Sensors

WLS28-2 Dual Color LED Strip Light

Q45BW13 Series Sensors

WLS27 Dual Color LED Strip Light

INTMOD485-LH Protocol Converter

ivu Bar Code Reader (BCR) Image Sensor with Integrated Display

WLC60 Heavy Duty Stainless Steel LED Light

Q4X Stainless Steel Analog Laser Sensor

WLB32 Industrial LED Light Bar (DC)

VS2 Series Opposed-Mode Sensors

ivu Plus Bar Code Reader (BCR) Image Sensor

WORLD-BEAM QS186LE Laser Emitter

EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors

QC50 Series True Color Sensor

OS80 Operator Stations

ivu Barcode Reader (BCR) Image Sensor for use with a Remote Display

EZ-LIGHT K50 & K80 Series Pick-to-Light Sensors

MICRO-AMP System. MA3-4 and MA3-4P Modulated Amplifiers

MINI-BEAM DC Sensors with Blue Light Source

XS/SC26-2 Safety Controller Quick Start Guide

MINI-BEAM dc-voltage Series

L-GAGE Q50 Series with Analog Output

ivu Plus TG Gen2 Series Image Sensor for use with a Remote Display

Wide-beam Divergent Mode Remote Sensor. Wiring rules

MINI-BEAM AC Voltage Series

U-GAGE Q45U Ultrasonic Sensors

TL70 Modular Tower Light

Q45X Series Sensors Photoelectric sensors with expansion slot for field upgrades

MINI-BEAM SM2A312FP. MINI-BEAM Plastic Fiber Optic. Output Type. Supply Voltage E X C E S S G A I N. SPST Solid-state 2-Wire V ac E X C E S S

MINI-BEAM SMA31E/SM2A31R and SMA31EL/SM2A31RL

QM26 and QMH26 Series Sensors

PVD Series Parts Verification Sensor

Q45U Ultrasonic Sensors

WORLD BEAM QS18LLP Series

PMDX-170 Slotted Optical Sensor

MINI-BEAM SM31E/SM31R and SM31EL/SM31RL

ivu Plus BCR Gen2 Series Sensor for use with a Remote Display

Sure Cross Vibration and Temperature Sensor

Q5X Laser Triangulation Sensor with Background Suppression

TL70 Wireless Communication Segment

Sure Cross Wireless Q45 Sensor Node - Vibration/Temperature

MINI-BEAM SM2A312F. MINI-BEAM Glass Fiber Optic. Output Type E X C E S S G A I N m.033 ft. SPST Solid-state 2-wire E X C E S S G A I N

XS/SC26-2 Safety Controller. Quick Start Guide

Q45U Ultrasonic Sensors

MINI-BEAM SM312W and SM312DBZ

PVD Series Parts Verification Sensor

EZ-LIGHT K50 and K80 Series Pick-to-Light Sensors

MINI-BEAM SM312LV, SM312LVAG and SM312LP

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

MINI-BEAM SM2A312CV and SM2A312CV2

QS30 Series. Diffuse-Mode Laser Sensors. QS30 Laser Models. Supply Voltage. 2 m (6.5') 5-wire Cable. Integral 5-pin Euro-style QD.

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

EZ-LIGHT Touch K50 Series Illuminated Buttons

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

Series 7000 Miniature Rectangular Style

MINI-BEAM DC Voltage Series

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Photoelectric Sensor

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

20W Tungsten-Halogen Light Source. Operation Manual

Photoelectric Sensor

MINI-BEAM SM2A312LV, SM2A312LVAG and SM2A312LP

DFP Series Fiber Photoelectric Amplifiers

MPP200 User s Manual

Model NPN output PNP output Standard. configuration

S82S (3/7.5-W Models)

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

TSD-DA28 2x8 Balanced Line Distribution Amplifier

EZ-LIGHT K50 and K80 Specialty 3-Color

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

L-GAGE LT3 Long-Range Time-of-Flight Laser Sensor

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

ECONO-BEAM Sensors. Miniature Self-Contained DC Sensors. ECONO-BEAM Features

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Photoelectric Sensors Enhanced 50 Series

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

42JS & 42JT VisiSight

Transcription:

Datasheet Powerful Self-Contained Sensors for Use with Glass or Plastic Fiber Optic Assemblies Fiber optic sensors for DIN rail mounting; cabled or quick disconnect (QD) Fast response: 500 μs standard, 50 μs for Y & Y models Visible red light source; models for use with either glass or plastic fibers Choice of either NPN (sinking) or PNP (sourcing) complementary outputs; 50 ma maximum (continuous) load Normally closed output of most models may be wired as a diagnostic alarm output (depending upon hookup to power) Sensors operate from 0 V dc to 0 V dc LED indicators for Power On and N.O. Output Conducting 7-segment LED bargraph indicates received signal strength, output overload, and marginal excess gain WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. CAUTION: Electrostatic Discharge (ESD) ESD Sensitive Device. Use proper handling procedures to prevent ESD damage to these devices. The module does not contain any specific ESD protection beyond the structures contained in its integrated circuits. Proper handling procedures should include leaving devices in their anti-static packaging until ready for use; wearing anit-static wrist straps; and assembling units on a grounded, static-dissipative surface. Models Glass Fiber Optic Sensors Models Output Type Response Speed Range DSN6FV(Q) NPN Standard 500 μs response time DSN6FVY(Q) NPN Selectable 50 μs high speed response mode DSN6FVY(Q) NPN Selectable 50 μs high speed response mode and 0 ms pulse stretcher DSP6FV(Q) PNP Standard 500 μs response time See the performance curves DSP6FVY(Q) PNP Selectable 50 μs high speed response mode DSP6FVY(Q) PNP Selectable 50 μs high speed response mode and 0 ms pulse stretcher Plastic Fiber Optic Sensors Models Output Type Response Speed Range DSN6FP(Q) NPN Standard 500 μs response time DSN6FPY(Q) NPN Selectable 50 μs high speed response mode DSN6FPY(Q) NPN Selectable 50 μs high speed response mode and 0 ms pulse stretcher DSP6FP(Q) PNP Standard 500 μs response time See the performance curves DSP6FPY(Q) PNP Selectable 50 μs high speed response mode DSP6FPY(Q) PNP Selectable 50 μs high speed response mode and 0 ms pulse stretcher Overview D sensors are compact, self-contained visible-red fiber optic sensors for DIN rail mounting. D sensors are designed for use with Banner glass and cutto-length plastic fiber optics. Standard DFP and DFV plastic and glass fiber optic sensors offer fast 0.5 millisecond (500 μs) response. DFVY Series and DFPY Series sensors have switch-selectable 50 μs/500 μs response modes for applications that require a faster, high speed response time. DFVY and DFPY models have switch-selectable response times along with a built-in 0 ms pulse stretcher for use with loads (or input circuits) that are too slow to react to quick sensing events when using the 50 μs response mode. Include "Q" in model suffix to specify 6-inch cable with -pin pico-style QD. Omit "Q" to specify models with 6-foot attached cable. Models with 0-foot attached cable are available. Original Document 8 Rev. G September 07 8

All models operate from 0 V dc to 0 V dc. D sensors are available with a choice of NPN or PNP complementary outputs (one output normally open, one output normally closed). The normally closed output of FP and FV models (only) may be used as a diagnostic alarm output, depending on the wiring of the sensor to the power supply. All models are available with either an attached cable or a 6-inch cable with a pico-style quick disconnect connector. Plastic fiber models may be used with either the small diameter (0.5 mm and 0.508 mm/0.00 inch and 0.00 inch) or the large diameter (.06 mm/ 0.00 inch) Banner cut-to-length plastic fibers. LED Indicators Two top-mounted LED indicators: Green = dc power on Amber = Normally Open Output Conducting Seven-Segment Moving-Dot LED Bargraph On all D sensors operating in the 500 μs (standard) response mode, a red sevensegment moving-dot LED bargraph illuminates to indicate the relative strength of the received light signal. This feature simplifies the sensitivity adjustment and fiber optic alignment, and provides a constant reference over time for overall sensing system performance. In all models and in both response modes, segment # of the bargraph flashes to indicate an output overload. On all sensors operating in the 500 μs response mode, segment #7 flashes to indicate marginal excess gain. On standard (FP and FY) models, a flashing LED corresponds to the On state of the D's alarm output. Note: The seven segment bargraph and marginal excess gain indication (segment #7) are inoperative in the 50 μs response mode on Y and Y models. Sensivity Control Ds have a 5-turn sensitivity control, with a slotted brass screw clutched at both ends of travel. Figure. Features Installing Glass Fibers. Gently seat an o-ring onto each sensor end of the fiber. Sensor end, glass fiber O-ring (supplied with fiber) Groove. Slide the sensor ends into the fiber ports as far as they will go.. Push firmly on the fiber ends to compress the o-ring, and while holding the sensor ends snugly in place, slide the fiber retaining clip into the slot.. Press the retaining clip in until it snaps into the groove. Installing Plastic Fibers. Cut the fiber ends according to the instructions included with the fibers.. Slide the fiber gripper up (open).. If you are using 0.5 mm or 0.508 mm (0.00 inch or 0.00 inch) diameter fibers: Insert the adaptor into the ports as far as it will go. Fiber adapter. For all fiber diameters: Insert the prepared plastic fiber sensor ends gently into the ports as far as they will go. 5. Slide the fiber gripper back down to lock it. www.bannerengineering.com - Tel: -76-5-6 P/N 8 Rev. G

Wiring Diagrams NPN (Sinking) Standard Wiring NPN (Sinking) Alarm Wiring 0-0V dc Alarm 0-0V dc PNP (Sourcing) Standard Wiring PNP (Sourcing) Alarm Wiring 0-0V dc Alarm 0-0V dc Specifications Sensing Range See the excess gain curves; Performance Curves Glass Fiber Optic Sensors on page 5 and Performance Curves Plastic Fiber Optic Sensors on page 5 Sensing Beam Visible red, 680 nm Supply Voltage 0 V dc to 0 V dc at 5 ma maximum, exclusive of load Protected against reverse polarity and inductive load transients Output Configurations Solid-state dc complementary outputs; see the models table for details. The normally closed (N.C.) output of standard FP and FV models may be used as an alarm output, depending upon the hookup to the power supply. Output Rating Complementary outputs, one normally open (N.O.) and the other normally closed (N.C.). 50 ma maximum each output. No false pulse on power-up. (False pulse protection circuit causes a 0. second delay on power-up.) Short-circuit protected. Off-state leakage current <0 µa at 0 V dc On-state saturation voltage < V at 0 ma dc; <.5 V at 50 ma dc The total load may not exceed 50 ma Response Time (FV, FP models) 500 µs on; 500 µs off Repeatability is 0 µs Response Time (FVY, FVY, FPY, and FPY models) FVY, FVY, FPY, and FPY models have switch-selectable standard 500 µs response mode plus a high speed (50 µs on/off) mode. Repeatability in the high-speed (50 μs) mode is 5 µs. FPY and FVY models (when used in the 50 μs response mode) include a 0 ms pulse stretcher for use in applications in which the load (or input circuit) requires a longer input signal. Response time and repeatability are independent of signal strength. Adjustments All models have a sensitivity control on top of the module (5-turn slotted brass screw, clutched at both ends of travel). FVY and FPY (high speed models) also have a topmounted response mode selector switch. Construction Black ABS housing with transparent acrylic cover. The fiber clamping element is acetal. Stainless steel M 0.5 hardware for use with mounting bracket (supplied). Connections m (6.5-ft) or 9 m (0-foot) attached PVC-covered cable, or 6-inch cable with pico-type -pin QD connector Mounting Bracket D Series sensors mount directly to a standard DIN rail, or may be through-hole mounted using the supplied mounting bracket and M x 0,5 hardware Bracket material is black PBT polyester Environmental Rating NEMA ; IEC IP Operating Conditions Operating Temperature: 0 C to 70 C ( F to 58 F) 90% at 50 C maximum relative humidity (non-condensing) Application Notes D Series sensors are designed to deliver very high optical energy (excess gain). They should not be used for applications which offer low optical contrast (that is, only a small difference in received light levels between the light and dark sensing conditions). Examples include diffuse mode sensing of objects in front of a reflective background and opposed mode sensing of non-opaque materials. D sensors excel in applications requiring high excess gain (for example, for long-range sensing, sensing with long fiber lengths, diffuse sensing of materials with low reflectivity, etc.). Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class Power Supply. Supply wiring leads < AWG shall not be spliced. For additional product support, go to http://www.bannerengineering.com. Certifications Supply Wiring (AWG) Required Overcurrent Protection (Amps) 0 5.0.0.0 6.0 8 0.8 0 0.5 P/N 8 Rev. G www.bannerengineering.com - Tel: -76-5-6

Dimensions and Features Glass Fiber Optic Models Fiber-retaining Clip (Supplied with Sensor) 7-Segment Display Response Mode Selector * Output Indicator.0 mm (0.7") 6. mm (.5") 5.5 mm (.0") Power Indicator Sensitivity Adjustment 0.0 mm (.8") 0. mm (0.79") Mounting Bracket (Included) 5.0 mm (0.0") * Response Mode Selection on FVY and FVY models only Pull to Relase Bracket Glass Fiber Emitter Port Glass Fiber Receiver Port Dimensions and Features Plastic Fiber Optic Models 5.5 mm (.0") Fiber Gripper Slide up to install or release fibers Signal Strength and Diagnostics Indicators Response Mode Selector * Output indicator Power indicator Sensitivity Adjustment.0 mm (0.7") 0.0 mm (.8") 6. mm (.5") 0. mm (0.79") Mounting bracket (included) 5.0 mm (0.0") Pull to release bracket Plastic fiber emitter port Plastic fiber receiver port * Response Mode Selection on FPY and FPY models only Small fiber adapter Dimensions D Bracket D Sensors mount directly to a standard 5 mm DIN rail, or may be through-hole mounted using the supplied mounting bracket and stainless steel M 0.5 hardware..5 mm (0.0") Section A-A A. mm (0.09").5 mm (.00") 5. mm (0.60") 5.0 mm (.8") ø.5 mm () (0.75") ø 7.9 mm x.0 mm deep () (0." x 0.").5 mm () (0.6") 9.9 mm (0.9").8 mm (0.9") 0.9 mm (0.07") ø.5 mm () (0.8") 8.6 mm (0.").9 mm (0.7") A www.bannerengineering.com - Tel: -76-5-6 P/N 8 Rev. G

Performance Curves Glass Fiber Optic Sensors Diffuse Mode Opposed Mode Performance Curves Plastic Fiber Optic Sensors Diffuse Mode 0.00 Inch Fibers Diffuse Mode 0.00 Inch Fibers Opposed Mode 0.00 Inch Fibers Opposed Mode 0.00 Inch Fibers Opposed Mode 0.00 Inch Fibers and Model L Lenses for Extended Sensing Range P/N 8 Rev. G www.bannerengineering.com - Tel: -76-5-6 5

Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. Banner Engineering Corp. All rights reserved