Flow Measurement SITRANS F US Clamp-on

Similar documents
Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

SITRANS F flowmeters SITRANS F US

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/317. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Flow Measurement SITRANS F US Inline

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Flow Measurement SITRANS F US Inline

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Ultrasonic transmitters

Continuous level measurement Ultrasonic transducers

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Ultrasonic Flow Meter Brochure

Flow Measurement SITRANS F C

Weighing Electronics Stand-alone integrators

Continuous level measurement Ultrasonic controllers

Model Sono-Trak General Specification

Flow Measurement SITRANS F C

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Clamp-on Ultrasonic Gas Flowmeters Have Injected the New Blood into Natural Gas Check-metering and Custody Transfer Application

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

Flow Measurement SITRANS F C

Level Measurement Continuous level measurement - Ultrasonic transducers

UTM10 Series Ultrasonic Transit-time Flowmeters

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

SITRANS L Level instruments

Level Measurement Continuous level measurement - Ultrasonic transmitters

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers

DMTFP Portable Ultrasonic Flow Meters

Family of Water Cut Analyzers

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

MAGFLO MAG 5100 W Benefits Application Flow Measurement Mode of operation Function Integration

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

OPERATING INSTRUCTIONS

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Micro Motion 7845/7847 Series Density and Concentration Meters

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

Aysix 200 Hand-Held Flow Meter

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview

THE TECHNOLOGY BEHIND THE MEASUREMENT

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Series DMHF Heat Meter

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

MMT330 Series Moisture and Temperature Transmitters for Oil

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

DMT345 and DMT346 Dewpoint Transmitters

DUAL RANGE ACCURON 7200 CARTRIDGE METERS. eastech

Level and Flow Measurement. Flow Pulse

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

RHE26. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Clamp-On Transit Time Ultrasonic Flow Meters

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview

PanaFlow Gas Meter System

OPTISONIC 6400 Technical Datasheet

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

Flow Measurement SITRANS F C

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Data sheet deltwavec-f

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

AG3000 SERIES FLANGED MAGMETER

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

AG3000 SERIES FLANGED MAGMETER

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Transcription:

Overview SITRNS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power station applications. SITRNS FUG1010 is available in single, dual and optional four path configurations, with your choice of IP65 (NEM 4X) wall mount and IP66 (NEM 7) wall mount explosionproof enclosures. Benefits Easy installation; no need to cut pipe or stop flow Minimal maintenance; external sensors do not require periodic cleaning No moving parts to foul or wear as found in turbine and PD meters Eliminates the pressure drop or energy loss in orifice metering Wide turn-down ratio Choice of single, dual or optional four path versions - Single path version reduces initial investment - Multiple path versions provide higher accuracy, especially with limited straight run and poor flow profile conditions - In diametric reflect mode configuration, the meter is less sensitive to crossflow and swirl Wide-Beam technology provides improved accuracy over a wide range of flow velocity and operating pressure ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow Tolerant of most wet gas conditions Immune to most pressure reducing valve noise Optional rugged stainless steel sensor enclosure permits permanent and direct burial installations Easy to use Si-Ware diagnostic software pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Production Storage Design SITRNS FUG1010 is available in two enclosures: IP65 (NEM 4X) wall mount enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single path - Dual path - Four path (optional) IP66 (NEM 7) wall mount explosionproof enclosure constructed of cast aluminum stainless steel hardware, with glass window - Single path - Dual path - Four path (optional) Function IP65 (NEM 4X) and IP66 (NEM 7) flow display transmitters have integral button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away Current, voltage, frequency and RS 22 outputs (see specification section for details) nalog inputs for pressure and temperature ZeroMatic Path automatically compensates for zero flow drift Bidirectional flow operation 1 Mbyte data logger with both site and data logger storage English, Spanish, German, Italian and French language options Internal G-8 table for fixed gas composition is available for standard volume computation. Complete application and operation diagnostics, to assure calibration and operational integrity Upward compatibility and compliance with G-10 speed of sound measurement practice /88 Siemens FI 01 2017

Technical specifications Input ccuracy Flow range Flow sensitivity Minimum pressure Pipe size nalog inputs Output Standard outputs 0 m/s ( 100 ft/s), bidirectional 0.000 m/s (0.001 ft/s), flow rate independent 7 10 bar (100 145 psi), typical (gas composition and application dependent; plastic pipes support operation at atmospheric pressure) 25 mm 1.52 m (1 48 ) (for other sizes, consult factory) Current: 20 m, programmable Current: 20 m, a programmable, standard dditional 2 x optional Voltage: 10 V DC, menu programmable Open collector digital pulses (quadrature) Pulse rate: 5 khz VT100 RS 22 Typical accuracy Calibratable ccuracy Repeatability Zero drift 1 % 2 % of actual volume reading (higher accuracy is pipe condition and flow profile dependent) 0.2... 0.5 % of flow 0.05 % 0.1 %, of actual volume reading, for 1.5 0 m/s (5 100 ft/s) velocities (pipe condition dependent) 0.000 m/s (0.001 ft/s), with ZeroMatic Path active 5Hz Data refresh rate Rated operation conditions Degree of protection Wall mount IP65 (NEM 4X) Wall mount explosionproof IP66 (NEM 7) Gas temperature mbient temperature -40 +60 C (-40 +140 F) (for higher temperatures consult factory) -18 +60 C (0 140 F) Extended outputs Status/larm I/O HRT, BCnet MSTP/BCnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 Programmable form C relays Programmable N.O. Mer. Wet. Relays optional 1 Totalizer clear switch input 1 Totalizer hold switch input Design Dimensions Weight Power supply For IP65 (NEM 4X) and IP66 (NEM 7) see "System info and selection guide" see diagrams 90 240 V C, 50 60 Hz (0 V) or 9 6 V DC (12 W) Indication and operation Data logger memory 1 Mbyte, programmable for 17 data functions Display IP65 (NEM 4X) and IP66 (NEM 7) enclosures 128 x 240 pixel LCD with backlight Keypad IP65 (NEM 4X) and IP66 (NEM 7) Enclosures keypad buttons with tactile feedback Language options English, Spanish, German, Italian, French Siemens FI 01 2017 /89

Certificates and approvals IP65 (NEM 4X) wall mount flow display transmitter ratings FM and CS CE C-TICK TEX IP66 (NEM 7) wall mount explosionproof enclosure ratings FM and CS CE C-TICK TEX Transmitter N-I Class I, Div 2 S Class II, Div 2 Sensor I.S. Class I, II, Div 1 EMC Directive 2014/0/EU TEX Directive 2014/4/EU Transmitter: Ex II (1) G [Ex ia] IIC Ex II (1) G Ex nc [ia] IIC T5 Sensors: Ex II 1 G Ex ia IIC T5 Tranmitter XP Class I, Div 1 D-I Class II, Div 1 N-I Class I, Div 2 S Class II, Div 2 Sensor I.S. Class I, II, Div 1 EMC Directive 2014/0/EU TEX Directive 2014/4/EU Transmitter: Ex II (1) G [Ex ia] IIC Ex II (1) G Ex nc [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB+H2 T5 Sensors: Ex II 1 G Ex ia IIC T5 /90 Siemens FI 01 2017

Standard MLFB for quick delivery on Selection and Ordering data rticle No. Order code 7 M E 6 1 7-7777 0-7 7 7 7 K 1 2 + K 1 2 + R 1 2 Click on the rticle No. for the online configuration in the PI Life Cycle Portal. Design IP65 (NEM 4X) wall mount 0 Number of ultrasonic paths Dual path 2 Flowmeter functions and I/O configurations includes graphic or digital display Extended I/O B - Graphic display - 2 x 0... 10 V - 2 x 4... 20 m (active) - 2 x 4... 20 m (passive) - 2 x 0... 5 khz pulse outputs (TTL or OC) - 4xform C relays - 4 x logic inputs (totalizer control, TTL) - 4x4...20m analog input - 1 x Pt100 RTD input per channel (Dual channel/path) Meter power options 9... 6 V, DC B Communication options VT100 RS 22 0 HRT, BCnet MSTP/BCnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 1 RTD temperature sensor (includes mounting hardware for pipes above 1.5 /8 mm OD) No RTDs 0 1 x standard clamp-on RTD 1 2 x standard clamp-on RTD 2 1 x submersible clamp-on RTD 2 x submersible clamp-on RTD 4 Notes: 1. Temperature input is required for FUH systems 2. Only the Interface detector set up as a dual channel can use 2 RTD s Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See "Sensor selection charts" for specifications. C2H (high precision) 1) 600 mm (24") N D1H (high precision) 1) 1200 mm (48") P D2H (high precision) 1) 1200 mm (48") Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See "Sensor selection charts" for specifications. C2H (high precision) 1) 600 mm (24") N D1H (high precision) 1) 1200 mm (48") P D2H (high precision) 1) 1200 mm (48") pprovals FM/CS/CE (default) 1 TEX, CE, C-TICK 2 Standard MLFB product offering represents 4 to 6 weeks delivery time For sensor and RTD cables for quick delivery see tables at end of section. 1) Made with stainless steel construction. Siemens FI 01 2017 /91

Selection and Ordering data rticle No. Ord. code IP65 (NEM 4X) wall mount IP66 (NEM 7) wall mount explosionproof 7ME610-7ME61-7777 0-7 7 7 7 7 7 7 Click on the rticle No. for the online configuration in the PI Life Cycle Portal. Number of channels/ultrasonic paths Single path 1 Dual path 2 Special: Four path (NEM 4X and NEM 7 9 H 1 wall mount only) Flowmeter functions and I/O configurations (includes graphic or digital display) IP65 (NEM 4X) wall mount and IP66 (NEM 7) wall mount explosionproof units Standard I/O - Graphic display - 2 x 0... 10 V - 2 x 4... 20 m (active) - 2 x 0... 5 khz pulse outputs (TTL) - 4xform C relays - 4 x logic inputs (totalizer control, TTL) - 4x4...20m analog input - 1 x Pt100 RTD input per channel (Dual channel/path) - 1 x Pt100 RTD input (Multi channel/path) Extended I/O (Dual and multi channel/path B only) - Graphic display - 2 x 0... 10 V - 2 x 4... 20 m (active) - 2 x 4... 20 m (passive) - 2 x 0... 5 khz pulse outputs (TTL or OC) - 4xform C relays - 4 x logic inputs (totalizer control, TTL) - 4x4...20m analog input - 1 x Pt100 RTD input per channel (Dual channel/path) - 1 x Pt100 RTD input (Multi channel/path) Meter power options 90... 240 V C 9... 6 V DC B Communication options VT100 RS 22 0 HRT, BCnet MSTP/BCnet IP, Modbus RTU 1 & TCP/IP, Ethernet IP, Johnson N2, VT100 RS 22 RTD temperature sensor (includes mounting hardware for pipes above 1.5 outer diameter) No RTDs 0 1 x standard clamp-on RTD 1 2 x standard clamp-on RTD 2 1 x submersible clamp-on RTD 2 x submersible clamp-on RTD 4 Selection and Ordering data rticle No. Ord. code IP65 (NEM 4X) wall mount IP66 (NEM 7) wall mount explosionproof Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection chart" for specifications. (-40 F to +248 F), nominal 21 C (70 F): B1H (high precision) Trackmount and straps B2H (high precision) Trackmount and straps BH (high precision) Trackmount and straps C1H (high precision) C2H (high precision) D1H (high precision) D2H (high precision) DH (high precision) D4H (high precision) 7ME610-7ME61-7777 0-7 7 7 7 7 7 7 (-40 F to +248 F), nominal 65 C (150 F): B1H (high temperature range HP) Z P 1 K B2H (high temperature range HP) Z P 1 L BH (high temperature range HP) Z P 1 T C1H (high temperature range HP) Z P 1 M C2H (high temperature range HP) Z P 1 N D1H (high temperature range HP) 1) Z P 1 P D2H (high temperature range HP) 1) Z P 1 DH (high temperature range HP) 1) Z P 1 U D4H (high temperature range HP) 1) Z P 1 R K L T M N P U R /92 Siemens FI 01 2017

Selection and Ordering data rticle No. Ord. code IP65 (NEM 4X) wall mount IP66 (NEM 7) wall mount explosionproof Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection chart" for specifications. (-40 F to +248 F), nominal 21 C (70 F): B1H (high precision) Trackmount and straps B2H (high precision) Trackmount and straps BH (high precision) Trackmount and straps C1H (high precision) C2H (high precision) D1H (high precision) D2H (high precision) DH (high precision) D4H (high precision) 7ME610-7ME61-7777 0-7 7 7 7 7 7 7 Other versions (different size, mount, type or Z 1 Y pipe larger than DN 1200 (48 ) or corrosion resistant), add Order code and plain text. (-40 F to +248 F), nominal 65 C (150 F): B1H (high temperature range HP) Z 1 K B2H (high temperature range HP) Z 1 L BH (high temperature range HP) Z 1 T C1H (high temperature range HP) Z 1 M C2H (high temperature range HP) Z 1 N D1H (high temperature range HP) Z 1 P D2H (high temperature range HP) Z 1 DH (high temperature range HP) Z 1 U D4H (high temperature range HP) Z 1 R pprovals FM/CS/CE/C-TICK (default) 1 TEX, CE, C-TICK 2 1) Supplied spacer bar supports pipes up to 750 mm (0 inch). For pipes larger than 750 mm (0 inch) purchase also, spare part 7ME960-0MS40 (1012BN-4). Made with stainless steel construction. K L T M N P U R Selection and Ordering data Further designs Please add "-Z" to rticle No. and specify Order code(s). Cable assembly for sensors (add for # of paths) See "Sensor cable selection chart" Cable assembly for RTDs (add for # of RTDs) See "RTD cable selection chart" Cable termination kit (for one cable pair) Termination for standard, plenum and armored sensor cable Termination for submersible sensor cable RTD cable termination kit for standard RTD RTD cable termination kit for submersible RTD Insert RTD cable termination kit Cable gland kit Tag name plate Stainless steel tags with.2 mm (0.1 inch) characters (68 characters max.) Order code MLFB example pplication example clamp-on meter is required for a 00 mm (12 ) carbon steel gas line with a wall thickness of 12.7 mm (0.5 ). Meter electronics are to be located in a Class I Div 2 area only 18 m (60 ft) from the pipeline. 12 V DC power is available at the site. Dual path operation is desired for improved accuracy and redundant measurement. Pulse output will be primary flow data source. MLFB rticle No.: 7ME610-2BB00-01-Z K0 + K0 K.. R.. T01 T11 T21 T1 T41 T51 Y19 Selection and Ordering data rticle No. Ord. code SITRNS FUG1010 meter 7 M E 6 1 7-7777 0-7 7 7 7 7 7 7 family IP65 (NEM 4X) wall mount 0 Dual path 2 Option with digital pulse B 9... 6 V DC power option B RS 22 Standard 0 No RTD required 0 Sensor code for path 1 Sensor code for path 2 FM approval required 1 0 m (100 ft) sensor cab. for path 1 K 0 0 m (100 ft) sensor cab. for path 2 K 0 Siemens FI 01 2017 /9

Selection and Ordering data rticle No. Operating Instructions for SITRNS FUG1010 English NEM 4X wall mount & NEM 7 wall 5E02951519 mount explosionproof German NEM 4X wall mount & NEM 7 wall 5E0295151 mount explosionproof ll literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation High precision sensor selection chart IP68 Based on pipe wall thickness (steel pipes only) Sensor Order Pipe wall (mm) Pipe wall (inch) Pipe wall Code min. max. min. max. B1H K 2.0.0 0.08 0.12 B2H L.0 4.1 0.12 0.16 BH T 2.7. 0.106 0.128 C1H 1) M 4.1 5.8 0.16 0.2 C2H 1) N 5.8 8.1 0.2 0.2 D1H 1) P 8.1 11.2 0.2 0.44 D2H 1) 11.2 15.7 0.44 0.62 DH 1) U 7.4 9.0 0.29 0.54 D4H 1) R 15.7 1.8 0.62 1.25 1) Made with stainless steel construction. Sensor Cable (pair) Selection Chart Sensor cable codes for length and type options Cable length m (ft) Standard (PVC jacket) -40 +80 C (-40 +176 F) 1) Standard MLFB for quick deliver RTD Cable (single) Selection Chart RTD cable codes for length and type Cable length m (ft) Standard (teflon Submersible wrapped) (extruded jacket) -40 +200 C -40 +200 C (-40 +92 F) (-40 +92 F) Order code 6 (20) R01 1) R11 15 (50) R02 1) R12 0 (100) R0 1) R1 46 (150) R04 R14 61 (200) R05 R15 91 (00) R06 R16 1) Standard MLFB for quick deliver Submersible (polyethylene jacket) -40 +80 C (-40 +176 F) Plenum Rated (teflon jacket) -40 +200 C (-40 +92 F) rmored Order code 6 (20) K01 1) K11 K21 K1 15 (50) K02 K12 1) K22 K2 1) 0 (100) K0 1) K1 1) K2 K 46 (150) K04 1) K14 K24 K4 61 (200) K05 K15 K25 K5 91 (00) K06 1) K16 K26 K6-40 +80 C (-40 +176 F) /94 Siemens FI 01 2017