Modular CPU card and input / output card

Similar documents
VM600 modular CPU card and input /output card

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

PA 152. Probe mounting adaptor (high temperature)

VM600 system segregation and cyber security

AMC8 and IOC8T Analog monitoring card and input / output card

IP 172. Interconnection protection mounting kit. » From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems

CP 502. Piezoelectric pressure transducer. IECEx. » From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)

IECEx VSN010. VibroSmart DMS real-time Ethernet switch. » VibroSight compatible hardware from the. » Designed for operation with the VibroSmart

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES

VibroSmart DMS VSI010

VibroSight portable analyser VSPA. » From the Vibro-Meter product line» Portable condition monitoring system (CMS)

Meggitt Sensing Systems

3500/23E Transient Data Interface

3500/22M Transient Data Interface Module

3500/23E Transient Data Interface

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

F1000 User's Manual. (Version: V1.01)

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

DTM Distributed Transmitter Monitor

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

3500/22M Transient Data Interface

Model KB 400 Cooling incubators with compressor technology

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

B12-3U VMEbus PowerPC SBC

NetLinx NX Integrated Controller NX-1200 (FG )

VMS Co., Ltd. VMS Reliability Systems - Korea

Cisco Prisma II Platform

3500/32M 4-Channel Relay Module

NetLinx NX Integrated Controller NX-2200 (FG )

NetLinx NX Integrated Controller NX-2200 (FG )

NetLinx NX Integrated Controller NX-2200 (FG )

NetLinx NX Integrated Controller NX-3200 (FG )

USR-TCP Hard version: V2.0 File version: V

/8 DIN Universal Process Indicator

Product Specifications

DATA SHEET Advanced Graphical Interface, AGI 100 series

Prisma II Platform. Optoelectronics

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Modular PDU Smart metering for your IT

PAC BI-DP BIM and 8701-CA-BI Carrier

NetLinx NX Integrated Controller NX-3200 (FG )

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

NetLinx NX Integrated Controller NX-4200 (FG )

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Wall-/Pipe Mounted Universal Process Indicator

F701 3U CompactPCI MVB Interface Card

General Operating, Maintenance and Installation Manual

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference

FC726 Fire control panel

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

3500/92 Communication Gateway

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

IPC194. ipconv Protocol Converter

AC 800M for Compact Product Suite Outline of all modules

XBTGT6330 advanced touchscreen panel x 600 pixels SVGA " - TFT LCD - 24 V DC

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

3500/77M Recip Cylinder Pressure Monitor

CLASS LEADING PRODUCTS PROVEN TO MEET THE MOST DEMANDING INDUSTRY SPECIFICATION, DELIVERED ON TIME, EVERY TIME

AWARD WINNING PRODUCTS AND SERVICES TAKING OUT COST AND INCREASING OPERATING EFFICIENCY

CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

Flow Computer. FloWEB

3500/45E Position Monitor

TM221CE24R controller M IO relay Ethernet

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

3500/25 Enhanced Keyphasor*Module

XBTGT4340 advanced touchscreen panel x2 40 pixels QVGA - 7.5" - 24 V

DATA SHEET Advanced Graphical Interface, AGI 100 series

NetLinx NX Integrated Controller NX-1200 (FG )

NetLinx NX Integrated Controller NX-3200 (FG )

M-series MQ Controller

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

XBTGT6340 advanced touchscreen panel x 600 pixels SVGA " - 24 V

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

F4-3U CompactPCI PowerPC Peripheral SBC

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Sauter Systems

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

TM241CE24T controller M IO transistor PNP Ethernet

NetLinx NX Integrated Controller NX-2200 (FG )

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

FC724 Fire control panel

Simplified information where and how you want it.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

100mm Process Indicator Recorder

TM241CE40R controller M IO relay Ethernet

M-series MQ Controller

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

Modbus TCP/RTU Gateway

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

General Specifications

FC722 Fire control panel

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Optimux-108, Optimux-106

/8 DIN Motorized Valve Controller

Transcription:

Modular CPU card and input / output card FEATURES» From the Vibro-Meter product line» One-Shot configuration of all VM600 cards using a direct Ethernet or RS-232 serial connection from an external computer, such as a laptop, notebook or industrial PC, running the VM600 MPSx software» Local micro-display for visualisation of monitored outputs and alarm limits» Two Ethernet connections and up to three serial connections (RS-232/ RS-422 / RS- 485) can be accommodated simultaneously» External communication interfaces with third party devices such as a DCS or PLC» Industry standard protocols including Modbus RTU and Modbus TCP» Redundant communications links can be configured to improve availability» VM600 MPS rack () security» Extended operating range of 20 to 70 C Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E 1 / 7

DESCRIPTION The is a modular central processing unit (CPU) card intended for use in the VM600 series of machinery protection system and condition monitoring system racks from Meggitt Sensing Systems Vibro-Meter product line. Depending on the system requirements, the can be used alone in the rack (installed in the front card cage) or in conjunction with the associated input / output card (installed in slot 0 of the rear card cage, directly behind the ). The modular, highly versatile design of the means that all VM600 rack configuration, display and communications interfacing can be performed from a single card in a networked rack. The card acts as a rack controller and allows an Ethernet link to be established between the rack and a computer running one of the VM600 MPSx software packages (MPS1 or MPS2). The card consists of a carrier board with two PC /104 type slots that can accept different PC /104 modules: a CPU module and an optional serial communications module. All cards are fitted with a CPU module that supports two Ethernet connections and two serial connections. That is, both the Ethernet redundant and serial redundant versions of the card. Note: The primary Ethernet connection is used for communication with the VM600 MPSx software via a network and for Modbus TCP communications. The secondary Ethernet connection is used for redundant Modbus TCP communications. The primary serial connection is used for communication with the VM600 MPSx software via a direct connection. The secondary serial connection is used for Modbus RTU communications. Optionally, a card can be fitted with a serial communications module (in addition to the CPU module) in order to support additional serial connections. This is the serial redundant version of the card. The module s primary Ethernet and serial connections are available via the NET and RSR232 connectors on the front panel of the. However, if the associated card is used, the primary Ethernet connection can be routed to the 1 connector on the front panel of the (instead of the NET connector). When the associated card is used, the secondary Ethernet and serial connections are available via the 2 and RS connectors on the front panel of the. The card is an network interface (input / output) card for use with the card that provides connectors for the s communications interfaces. The card s 1 and 2 Ethernet connectors provide access to the primary and secondary Ethernet connections, and the RS serial connector provides access to the secondary serial connection. In addition, the card includes two pairs of A and B serial connectors that provide access to the additional serial connections (from the optional serial communications module) that can be used to configure multi-drop RS-485 networks of VM600 racks. The front panel features an LCD display that shows the level of a selected monitored output in bargraph and digital form, with the Alert and Danger levels also indicated on the bar-graph. The signal identification (slot and output number) is shown at the top of the display. The SLOT and OUT (output) keys on the front panel are used to select which signal to display. The ALARM RESET button on the front panel resets all latched alarms (and associated relays) for the entire rack. LEDs on the front panel indicate the OK, Alert (A) and Danger (D) status for the currently selected signal. When Slot 0 is selected, the LEDs indicate the overall status of the whole rack. When the DIAG (diagnostic) LED shows green continuously, the card is operating normally, and when the DIAG LED blinks, the card is operating normally but access to the card is restricted due to VM600 MPS rack () security. For security reasons, the card supports features that can be used to limit the functionality of the MPS that is available via the to Ethernetbased connections, helping to reduce the possibility of interference in the operation of the MPS and the machinery being monitored. VM600 MPS rack () security consists of two specific levels of protection integrated in the card: access lock (a hardware security feature) and MPS password validation (a software 2 / 7 Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E

security feature). Refer to the VM600 MPS hardware manual and the VM600 MPS1 software manual for further information. For specific applications, contact your nearest Meggitt Sensing Systems representative. SPECIFICATIONS CPU module Module type Processor type Processor speed Memory Power supply Operating system Communications ports (connections) Primary Ethernet Secondary Ethernet (requires the card) Primary serial Secondary serial (requires the card) : PFM-541I or equivalent : AMD Geode LX800 : 500 MHz : 256 MB DRAM : +5 V DC, < 1.8 A : QNX : Network interface: 10 /100BASE-TX. Data transfer rate: Up to 100 Mbps. Function: VM600 rack configuration and communications using the VM600 MPSx software, and Modbus TCP. Connector: NET ( card) or 1 ( card). : Network interface: 10 /100BASE-TX. Data transfer rate: Up to 100 Mbps. Function: Redundant Modbus TCP communications. Connector: 2 ( card). : Network interface: RS-232. Data transfer rate: Up to 115.2 kbaud. Function: VM600 rack configuration and communications using the VM600 MPSx software. Connector: RS232 ( card). : Network interface: RS-232 or RS-485. Data transfer rate: Up to 115.2 kbaud. Function: Modbus RTU communications. Connector: RS ( card). Note: The CPU module is fitted to all versions of the card. Serial communications module Module type Power supply Isolation Communications ports (connections) Additional serial : AIM104-COM4 or equivalent : +5 V DC, < 220 ma : > 100 V DC : Network interface: Two isolated RS-422 and / or RS-485. Data transfer rate: Up to 115.2 kbaud. Function: Modbus RTU communications. Connectors: Two A and two B ( card). Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E 3 / 7

SPECIFICATIONS LED indicators Diag OK A (Alert) D (Danger) : Green LED used to indicate the status of the card: off, normal operation and status of VM600 MPS rack () security : Green LED used to indicate the status of the OK system check (sensor OK link check) for the currently selected measurement channel : Yellow LED used to indicate the status of the alarm monitoring (Alert+ or Alert ) for the currently selected measurement channel : Red LED used to indicate the status of the alarm monitoring (Danger+ or Danger ) for the currently selected measurement channel Buttons ALARM RESET OUT and OUT+ SLOT and SLOT+ : Used to reset all latched alarms (and associated relays) in the entire VM600 rack : Used to select a measurement channel for the currently selected card (slot) : Used to select a slot (card) in the VM600 rack Connectors NET RS232 : 8P8C (RJ45), female. Used for the primary Ethernet connection. : DE-9 (9-pin D-sub), female Used for the primary serial connection. Note: The serial communications module is only fitted to the serial redundant version of the card. Note: Jumpers on the card are used to configure the required operation of Ethernet and serial connections and connectors. Refer to the VM600 MPS hardware manual for further information. Connectors RS A B : 6P6C (RJ11/ RJ25), female. Used for the secondary serial connection. : Two 6P6C (RJ11/ RJ25), female. Used for additional serial connections (requires the optional serial communications module). : Two 6P6C (RJ11/ RJ25), female. Used for additional serial connections (requires the optional serial communications module). 1 : 8P8C (RJ45), female. Can be used for the primary Ethernet connection (instead of the NET connector). 2 : 8P8C (RJ45), female. Used for the secondary Ethernet connection. Note: Jumpers on the card are used to configure the required operation of serial connections and connectors. Refer to the VM600 MPS hardware manual for further information. 4 / 7 Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E

SPECIFICATIONS General Electrical Supply voltage : 5 V DC ± 5% Power consumption : < 10 W : < 2 W RS-485 isolation : 500 V DC Environmental Temperature Operating Storage Humidity (operating and storage) : 20 to +65 C ( 4 to +149 F) : 25 to +80 C ( 13 to +176 F) : 0 to 90% relative humidity, non-condensing Physical Height : 6U (262 mm, 10.3 ) Width : 40 mm (1.6 ) Depth : 187 mm (7.4 ) Weight : 0.40 kg (0.88 lb) approx. Height : 6U (262 mm, 10.3 ) Width : 20 mm (0.8 ) Depth : 125 mm (4.9 ) Weight : 0.25 kg ( 0.55lb) approx. Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E 5 / 7

ORDERING INFORMATION To order please specify Type Designation Ordering number Different versions of the modular CPU card: Ethernet redundant Modular CPU card with a CPU module that supports two Ethernet interfaces and two serial interfaces. This supports Ethernet interfaces on the front panel () and the rear panel (), a serial interface (RS-232) on the front panel () and a serial interface (isolated RS-232 / RS-485) on the rear panel (). A front panel display and an operating system licence are also included. Ethernet redundant varnished Same as the Ethernet redundant version, with a conformal coating for additional environmental protection. Serial redundant Modular CPU card with a CPU module that supports two Ethernet interfaces and two serial interfaces, and a serial communications module that supports additional serial interfaces. This supports Ethernet interfaces on the front panel () and the rear panel (), a serial interface (RS-232) on the front panel () and a serial interface (isolated RS-232 / RS-485) on the rear panel (). It also supports two additional serial interfaces (RS-422 / RS-485) on the rear panel (). A front panel display and an operating system licence are also included. 601-003-000-VVV\3\610-1CC-CCC (equivalent to a 200-595-0Ss-33h with a configuration) 601-003-000-VVV\3V\610-1CC-CCC (equivalent to a 200-595-0Ss-33hl with a configuration) 601-003-000-VVV\5\610-1CC-CCC (equivalent to a 200-595-0Ss-53h with a configuration) Different versions of the input / output card for the : Standard 200-566-000-1Hh Varnished Same as the standard version, with a conformal coating for additional environmental protection 200-566-000-1HhL Notes The different versions of the card are supplied pre-configured with different configurations, as denoted by the 9-digit code in the ordering number (610-1CC-CCC). 1CC-CCC represents the different configurations that can be used by a finished product. For example, 610-100-000 corresponds to the standard configuration that is uploaded to a card (200-595-0Ss-HHh), if no other configuration is specified. For information on other configurations, contact Meggitt Sensing Systems. Ss represents the firmware (embedded software) version and Hh the hardware version of a card. S/H increments for major modifications that can affect product interchangeability and s/h increments for minor modifications that have no effect on interchangeability. VVV represents the different firmware (embedded software) versions and hardware versions that can be used by a finished product. For information on ordering a / as a part of a VM600 system rack, refer to the ABE040 and ABE042 VM600 system rack data sheet. 6 / 7 Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E

RELATED PRODUCTS ABE040 and ABE042 VM600 system rack : Refer to corresponding data sheet Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12 345.678 90. Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ISO 9001 FS 584089 ABCD Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland Tel: +41 26 407 11 11 Fax: +41 26 407 13 01 www.meggittsensingsystems.com www.vibro-meter.com Meggitt SA / 268-031 / Version 12 / 15.07.2015 / E 7 / 7