Wiring Diagrams INDEX. UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK Field Wiring 09DK DK054,064

Similar documents
Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Installation Instructions Part No: 38AP , 38AP , and 38AP

Installation Instructions

Specification and Design Catalog. Waterside Economizer

Installation Instructions

Installation Instructions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

CONTROLLER INSTALLATION OPERATION & QUICK START

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel

Installation Instructions

FC-DIN DIN-Rail Mount Fan Speed Controller

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

HomeWorks Remote Power Feed-Through Panels

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

P216. Condenser fan speed controller. Product bulletin. Features

FX 2 Instruction Manual

SAMPLE HEAT PUMP WIRING DIAGRAMS

ML7421A,B Electric Linear Valve Actuators

S66 Series Electronic Fan Speed Control

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

AE R6 July 2018 Electronic Unit Controller

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

TPE 1464 Series Pressure Transducer

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control INDUSTRY LEADING FEATURES / BENEFITS

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

INSTALLATION INSTRUCTIONS

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6

Installation and Start-Up Instructions

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

Ceiling Concealed Split System C Series

Sealed Enclosure Cooling Air Conditioners

3RT, 3TB, 3TF Contactors for Switching Motors

920 Remote Control (RC) Switches

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

4-step Chiller and Heat Pump Controller

IBS IL 24 BK RB-T-2MBD

C7110C1001A / C7110D1009A WALL MODULES

AIR COOLED CONDENSERS

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

ASCO 920 Remote Control (RC) Switches

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Contactors and Contactor Assemblies

SURGE GUARD RV POWER PROTECTION

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

BD Controller 101N07xx Series 24 V DC with Tool4Cool LabEdition software Operating Instructions

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

P216 Series Condenser Fan Speed Controller

Installation Instructions

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

Next Generation Critical Cooling for Room and Row. Liebert PEX Efficiency And Reliability For High Availability Cooling. Condenser Technical Manual

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

EVC INTERFACE TOOL OPERATION MANUAL EVC INTERFACE TOOL. Part No Part No Effective July 27, 2011 Revised December 18, 2012

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

Liebert.PEX Condenser User Manual

FOR SERVICE TECHNICIAN S USE ONLY

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Electrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

TEC Unit Conditioner Controller

M5100 Heavy Industrial Pressure Transducer

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63. 1) This manual is valid for the following Model and associated serial numbers:

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Datasheet.

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

AUTOMOTIVE MICRO-ISO RELAY FEATURES

Transcription:

09DK054-094 Air-Cooled Condenser Units 50/60 Hz Wiring Diagrams INDEX UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK054-094 Field Wiring 09DK500319 1 09DK054,064 Wiring Diagram and Component Arrangement 09DK500306 2 09DK074-094 Wiring Diagram and Component Arrangement 09DK500307 3 LEGEND ATS Air Temperature Switch AWG American Wire Gage CR Control Relay DU Dummy Terminal EQUIP Equipment FC Fan Contactor FCPS Fan Cycle Pressure Switch FIOP Factory-Installed Option FM Fan Motor GND Ground MMSN Motormaster Sensor NEC National Electrical Code PL Plug Assembly PRI Primary SEC Secondary TB Terminal Block TRAN Transformer XL Across-the-Line Start Terminal Block Connection Marked Terminal Unmarked Terminal Unmarked Splice Marked Wire Factory Wiring Field Wiring Indicates common potential; does not represent wiring. NOTES 1. Units are factory wired for a 50/50% capacity split. If 100% capacity is required, connect the factory-supplied jumpers from TB2-1 to TB3-1 and from TB2-2 to TB3-2. If jumpers are connected for 100% capacity, only one control power supply is required. 2. When a fan control kit is used, the jumper from TB2-1 to TB3-1 and from TB2-2 to TB3-2 must be connected. The fan control kit is factory wired for 67/33% capacity split. If a 33/33/33% capacity split is required, remove the jumper from TB4-1 to TB5-1 and from TB4-2 to TB5-2. If a 33/33/17/17% capacity split is required, remove the jumper from TB4-1 to TB5-1 to TB7-1 and from TB4-2 to TB5-2 to TB7-2. 3. On fan control kits, 208/230-v units are factory wired for 230-v power supply. For 208-v power supply, connect yellow wire to terminal marked H2. 4. Terminal blocks TB2, TB3, TB4, TB5, TB6, and TB7 are for external field control connections. Control connections are to be class 1 wiring, 14 AWG (2.08 mm 2 ) copper conductors only. 5. Wiring for field power supply must be rated 75 C minimum. Use copper, copper-clad aluminum, or aluminum conductors. Maximum incoming wire size for each terminal block is 2/0 (67.4 mm 2 ). 6. Replacement of factory wires must be with 105 C appliance wiring material or its equivalent. 7. Factory wiring is in accordance with National Electrical Code (NEC). Field modifications or additions must be in compliance with all applicable codes. 8. Fan motors are thermally protected. Three-phase motors are protected against primary single phasing conditions. 9. Line numbers on the left side of the label diagrams indicate the contact number. The numbers on the right side of the label diagrams match the contacts with their corresponding coils. A plain number indicates normally open contacts. An underlined number indicates normally closed contacts. 10. MAIN POWER SUPPLY CONTROL CIRCUIT V-PH-HZ V-PH-HZ 208/230-3-60 460-3-60 115-1-60 575-3-60 380-3-60 230-1-60 380/415-3-50 230-1-50 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 111 Catalog No. 530-961 Printed in U.S.A. Form 09DK-3W Pg 1 9-94 Replaces: 09DK-2W Tab 4a

OPERATION Accessories FAN CONTROL KIT (054-084 Units Only) With the 67/33%, 33/33/33% and 33/33/17/17% nominal capacity split options, 3 or 4 FCPSs are used. For these applications, an accessory fan control kit is required. Fans 2, 4, and 6 are shared by the 67% and 33% refrigerant circuits on 67/33% applications. With 33/33/33% applications, fans 1, 3, 5 and 2, 4, 6 are shared by two of the 33% refrigerant circuits. With 33/33/17/17% applications, fans 1, 3, 5 and 2, 4, 6 are shared by a 33% and a 17% refrigerant circuit. The fan control kit ensures that the fans operate when needed for efficient control. NOTE: Fans 5 and 6 are used on 09DK074 and 084 units only. The fan control kit panel is factory wired for a 67/33% capacity split. It utilizes TB4 for the 67% control circuit and TB6 for the 33% control circuit. See Fig. 1 for wiring details for 67/33%, 33/33/33%, and 33/33/17/17% capacity splits. To determine fan and refrigeration circuit connections, refer to fan control kit accessory installation instructions. TRANSFORMER The control transformer is used to convert 208, 230, or 460 v to 115 v for use on 115 v condenser unit control systems, sourcing power from the main unit power connections. MOTORMASTER III HEAD PRESSURE CONTROL DEVICE The Motormaster III device is a motor speed control which adjusts condenser fan motor speed in response to changes in liquid temperatures. A properly applied Motormaster III control extends the operating range of air conditioning systems and permits operation at lower outdoor ambient temperatures. The Motormaster III control permits operation of the unit to an ambient temperature of 20 F ( 29 C). This device controls the speed of 3-phase fan motors that are compatible with the Motormaster III control. These motors are installed at the factory and are used on fans 1 and 2. NOTE: Two Motormaster III controls must be added for each of these units, one for each circuit. For more information, refer to the Motormaster III accessory installation instructions. MOTORMASTER III RELAY/SENSOR KIT (054-084 Units Only) The Motormaster III Relay/Sensor kit is used to provide efficient control of the primary fans (fans 1 and 2) on 09DK condensers with nominal 67/33%, 33/33/33%, and 33/33/17/17% split applications. On 67/33% applications, fan no. 2 is shared by the 33% and 67% refrigerant circuits. This accessory ensures that the first circuits on and the last circuits off control the Motormaster III device. One kit is required for 67/33% applications. Two kits are required for 33/33/33% and 33/33/17/17% applications. See Motormaster III Relay/Sensor kit accessory installation instructions for more information. Sequence of Operation The 09DK units have fully automatic intermediate-season head pressure control through condenser fan cycling, using electro-mechanical fan cycling controls. Standard head pressure controls are supplied for 100% and 50/50% condenser capacity applications. Other circuit split applications (67/33%; 33/33/33%; 33/33/17/17% nominal capacity splits) require the accessory fan control kit. In the standard control scheme, fans 1 and 2 are on when there is a call for cooling from their respective control circuits. Fans 1 and 2 are non-cycling. On all units, fans 3 and 4 are controlled by a fan cycling pressure switch that responds to condensing pressure on each of the primary coil circuits. On 074-094 units, fans 5 and 6 are controlled by two air temperature switches that respond to the outdoor ambient temperature. The air temperature switches are located on the control box shelf. Fan cycling pressure switch control: Fans 3 and 4 are on above 260 ± 15 psig (1793 ± 103 kpa) and off below 160 ± 10 psig (1103 ± 69 kpa). If pressure is rising between 160 psig (1103 kpa) and 260 psig (1793 kpa), fans 3 and 4 are off. If pressure is decreasing from 260 psig (1793 kpa) to 160 psig (1103 kpa) fans 3 and 4 are on. Air temperature switch control: On the 074-094 condensers, below 70 ± 3 F (21.1 ± 1.7 C) outdoor ambient, fans 5 and 6 are off; above 80 ± 3 F (26.7 ± 1.7 C), fans 5 and 6 are on. Between 70 F (21.1 C) and 80 F (26.7 C) whether fans 5 and 6 are on or off depends on whether temperature is rising or falling. If the temperature is rising from 70 F (21.1 C) to 80 F (26.7 C), fans 5 and 6 are off. If the temperature is falling from 80F(26.7C)to70F(21.1C)fans5and6areon. 2

Fig. 1 Field Wiring; 054-094 Units 3

Fig. 1 Field Wiring; 054-094 Units (cont) 4

Fig. 2 Wiring Diagram and Component Arrangement; 054 and 064 Units 5

Fig. 2 Wiring Diagram and Component Arrangement; 054 and 064 Units (cont) 6

Fig. 2 Wiring Diagram and Component Arrangement; 054 and 064 Units (cont) 7

Fig. 3 Wiring Diagram and Component Arrangement; 074-094 Units 8

Fig. 3 Wiring Diagram and Component Arrangement; 074-094 Units (cont) 9

Fig. 3 Wiring Diagram and Component Arrangement; 074-094 Units (cont) 10

Copyright 1994 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 111 Catalog No. 530-961 Printed in U.S.A. Form 09DK-3W Pg 12 9-94 Replaces: 09DK-2W Tab 4a