OPTICAM 2 QUICK SETUP GUIDE

Similar documents
OptiCam 2. Terminating OptiCam Connectors Using OptiCam 2 Termination Tool

LDM M LASER DISTANCE MEASURER

ENVIRONMENTAL PROTECTION

SCT-MMA / SCT-SMA Fiber Optic Adapters

CONTENTS. Model no: NT-013

IMPORTANT SAFETY INSTRUCTIONS

Mini Digital Multimeter

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Guide True RMS Multimeter Extech EX205T

X-Beam Waterproof Action Camera Light USER GUIDE

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

RunFit USERS GUIDE. Fitness Tracker Activity Band JRV-SBD1500

HV-CS kv Edge Mount Triaxial Jack

Copyright Black Box Corporation. All rights reserved.

Mini Digital Multimeter Model MN15. User's Guide

User's Guide. Digital Multimeter. Model MN42

FiberExpress Brilliance Connectors

RunFit USERS GUIDE. Fitness Tracker Activity Band JRV-SBD1500

Green Rotary Laser Level

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

User s Manual. Model SU1007A AQ LD Light Source (1310/1550 nm) IM SU1007A-01E 3rd Edition

Mini Digital Multimeter

SCT2000 and SCT1500 Structured Cable Testers

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Overview. Inspection and Cleaning CHAPTER

FOCIS Flex Inspection

Model 2380 Rack-Mount Kit

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

IMPORTANT SAFETY INSTRUCTIONS Do not use the product before you have studied the Safety instructions and the User Manual.

DS-1H05 Ethernet-over-Coax Extender. User Manual

ACTIVE FIT+HR. Fitness Tracker Activity Band USERS GUIDE

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

Dell Networking S4100-ON Series. Set-Up Guide

Laser Projection keypad

ES2000 INFRARED THERMOMETER IMPORTANT SAFETY INSTRUCTIONS

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

WiFi Connector. Instructions. Introduction. Safety. XWWarning

PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User Manual Revised 1-July-2015

Konica Minolta s industrial instruments. Safety Precautions

Model R5010. TRMS Digital Multimeter. Instruction Manual

HD Flex Zero RU Cassette Holder and Bracket

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Video Borescope Inspection Camera

Video Borescope Inspection Camera

Manual Version: V1.00. Video Decoder User Manual

Operating Instructions

Airborne Particle Counter

1. Safety instructions

RZ5/RZ5D/RZ6 Processor. Operator s Manual

AFC-3000 Automated Optical Connector Ferrule Cleaner

SHUTTERBOSS VERSION II USER MANUAL

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

USER MANUAL. True RMS Multimeter. Extech EX430A

FengMi Wemax One Laser Projection TV

True RMS Multimeter with IR Thermometer

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

Multi-touch Touch-Screen. Installation Guide

Autoranging Mini Multimeter

EOS-6000 Series Optical A/B Switch User Manual DC Version

OPERATIONS GUIDE OWL

S5048F-ON. Set-up Guide

DISCLAIMER: All products, logos, brand names, or companies are trademarks or registered trademarks of their respective owners!

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

8 RUGGED ANDROID TABLET CONKER ST80

Installation Job Aid for VSP 4850GTS

These items can be purchased separately or as a kit from your distributor.

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

FiberLink 6650 Series

True RMS Multimeter with IR Thermometer

FREEWAVE PLUS USER MANUAL

OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

FOCTT2 Firmware Update Tool for Windows v1.0.7

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

CLLi Please read these instructions before operating the product. 2 - Beam Self-Leveling Cross Line Laser

SPOTTER the multipurpose sensor

OFSR-X. Users Manual. OptiFiber Smart Remote Options

Front view ENGLISH. Speaker. Infrared receiver (for optional remote control) Microphone. Power. Recording light. Lens HDMI Out. USB/AV Out.

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

Mini Digital Multimeter

TASER CAM HD Recorder User Manual

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

Fusion HD. Quick Start Guide. Nixeus Technology, Inc. Version 1.1

ECOLINE EL 515 PLUS EL 515 PLUS SET

Leica TS11 Quick Guide. Version 2.0 English

Instruction Manual. 14 Portable DVD Player - BPDVD14

E8431 First Edition Model: T00CP

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MultiLine Please read these instructions before operating the product. 5 - Beam Self-Leveling Multi-Line Laser

Medimaging Integrated Solution Inc.

VW2106 VW Readout Manual

Transcription:

OPTICAM 2 QUICK SETUP GUIDE Please update the OptiCam 2 Tool to the most recent firmware available at panduit.com. http://www.panduit.com/en/support/download-center/

FOCTT2 OptiCam 2 Termination Tool Quick Setup Guide Panduit Corp. 2017 WARNING Read and understand the instructions and safety information in this manual before operating this tool. Failure to observe this warning can result in bodily injury. Warning: Risk of fire. Battery can explode or leak and cause injury if installed backwards, disassembled, charged, crushed or exposed to fire or high temperature. CAUTION Caution - Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. The laser is emitted from the LC connector located at the top of the tool. See the next page illustration for connector location. Never point the laser into the eyes of others. Do Not stare directly at the laser beam. Do Not set up tool to work at eye level or operate the tool on a reflective surface as the laser could be projected into your eyes or the eyes of others. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 3.9 (99 mm) may pose an eye hazard. Remove the batteries when storing for an extended period of time to avoid damage to the tool should the batteries deteriorate. TECHNICAL INFORMATION Recommended Use: With available launch cords and cradles only Laser Diode Type: IEC 60825-1 Class 1 Laser product Connectors: LC, SC, ST, singlemode and multimode, Panduit connectors only Power Supply: 2 size AA (type L91) 1.5volt Lithium Iron Disulfide batteries, Max Discharge: 2.5 amp continuous, included. Size AA alkaline batteries can be used at a reduced rate battery life. Tool can also be powered without batteries through the power/data (5 VDC, 1 amp max) port on the side of the tool. Rated Battery Life: Approximately 8 hours (continuous use) Firmware Updates: Use power/data port on the side of the tool to connect to PC, visit www.panduit.com for latest firmware Environment: FOR INDOOR USE ONLY Max altitude 2000m Pollution degree 2 Operating Temperature: +32 F to +104 F (0 C to +40 C), <93% RH, noncondensing Storage Temperature: -40 F to +158 F (-40 C to +70 C) Overall Dimensions: 2.1" H x 2.8" W x 9.1" L (53mm x 71mm x 231mm) Weight: 9.0 oz (255 g) without batteries Tool Storage After all connector terminations are complete, detach the launch cord from the tool by disconnecting the LC connector at the top of the tool. Detach the ferrule adapter from the cradle and put dust caps on both ends of the launch cord. Place tool, launch cord, and cradle in a protective case. Care and Handling Laser tools are precision instruments, which should be handled with care. Avoid shock, vibrations, and extreme heat. Avoid dust and water that could obstruct laser. Keep tool dry and clean. Check batteries regularly to avoid deterioration. Remove batteries if the tool is to be stored for an extended period. Tool Maintenance This tool contains no user serviceable parts. The laser output is not user adjustable. Contact Panduit Corp. for service needs. Symbols This symbol indicates the need for separate collection of electrical and electronic equipment waste. Separating electronic waste can halt the potential adverse effects on the environment and human health as a result of the hazardous substances in electrical and electronic equipment. This waste should be returned to the proper collection facility. Page 1 of 7

Product Overview LCD display guides user through the termination process Launch cord removeable for changing from single or multimode fiber Self-aligning, reversible cradle for left or right orientation (right orientation shown) 5-way joystick navigates users quickly through the on-screen menus Step 1 Install batteries into the battery compartment, be sure to install the batteries in the correct orientation. Power on by using the center of the navigation button, pressing directly down. Press down on the navigation button to power on the tool Step 2 Use the navigation button to navigate to the menus and to Connector Type and select the correct connector options Use the navigation button left and right button to select the correct information. The selected text will become red, Save this option. Bluetooth Indicator Connector, orientation & color change to match selection Back icon Menus Next icon. The outline indicates this is current selection Page 2 of 7

Step 3 Install the correct OptiCam 2 launch cord and OptiCam 2 cradle. An LC connector on the launch cord attaches to a port at the top of the tool and the unique adapter attaches it to the cradle. The cradle attaches to the tool (singlemode LC launch cord, and LC Cradle are shown) with either a left or right orientation. LC Connector port Data Port Left orientation for cradle shown Launch cord snaps into the cradle Step 4 A) Insert a connector while the launch cord is tilted up to receive the connector. B) Tilt the connector down, ensure the connector backbone snaps in to the cradle. B A Note: Each connector has slightly different cradle operation. Refer to the individual connectors specific installation instructions. Step 5 REFER TO FIBER PREP STEPS IN USER INSTALLATION INSTRUCTIONS Have fiber prepped and cleaved to 7mm before starting the next termination steps. See the following Installation instructions for each connector: FS014 FS015 FS016 Page 3 of 7

Step 6 To start the connector test, select the Next icon, pressing the navigation button directly down. The tool will perform a background test of the connector. After passing the background test, the Insert Fiber command will display automatically. Insert cleaved fiber and maintain gentle forward pressure while waiting for the CAM & TEST command to appear on the screen. When the screen displays the CAM & Test command, A) Maintain gentle forward pressure on the field fiber, and B) Cam the connector, then select the Next arrow to perform test. B A Page 4 of 7

Step 7 Validate IL value meets project requirements. If needed, re-test by using the Re-test icon, or re-terminate using the Back icon and reperform steps 5 and 6. The OptiCam connector can be reused up to three times. Re-test icon Back icon Mobile App, install from App store on your mobile device. Connect-It. Select an existing project App Overview Tool list Tool Settings Test Window Projects Overview Step 1 After performing terminations, connect OptiCam 2 tool to the Connect-It app. Navigate to the menus of the OptiCam 2 tool and select: Tool Settings>Wireless>On. Then select Exit. Note: The tool name is found under Menus>Tool Settings>Tool Name. Rename for ease of use. Enter the wireless password given when registering the tool at Panduit.com Page 5 of 7

Step 2 Create a new project in Connect-It app. Enter Project information Create a Project Select an existing project Step 3 Connect to the OptiCam 2 tool, pull down to refresh the list, and select the appropriate tool name from the list. Step 4 The app will indicate that the tool has un-synced records. Select OK to sync which will transfer the records of the termination(s) to the app. Note: The records will no longer be available on the OptiCam 2 tool. Page 6 of 7

Step 5 Export the connector data. Navigate to the Project Overview, select the current project, and select the Share option. Your mobile device s default email will open with a CSV attachment containing the connector data. Page 7 of 7