Console Power Supply

Similar documents
ips10 ALLEN&HEATH USER GUIDE Digital Console Backup Power Supply Publication AP6688 ALLEN&HEATH ips10 DIGITAL SYSTEM BACKUP SUPPLY POWER OFF

Studio Console Power Supply

PS8 - II. Professional Power Sequencer. User s Manual

DM25, DM40. Compact 100V mixer-amplifiers with Bluetooth. Item ref: UK, UK User Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

ilive Mix System DSP MiniRack

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

AD-400. CD Player with USB/SD and FM Tuner. Item ref: UK User Manual

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

MODEL 805 USER MANUAL

HeadAmp6 PROFESSIONAL SIX CHANNEL HEADPHONE AMPLIFIER OPERATION MANUAL

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

MPF-1, Mains Power Filter User Manual

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE


PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

SUBWOOFER SYSTEM YST-MSW10

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DI8E Operating Manual

Ares. Modular Audiophile System. by Thrax Audio. Operating Manual. Manual issued 15/03/2018 CAUTION

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

TPC25 active crossover. user manual

PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

FT-20 Fire Training Fog Machine User Manual English

OWNER S MANUAL CD-2 V 1.3

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

Dual Link DVI Extender

FOR FURTHER INFORMATION CONTACT: Music Hall 108 Station Road Great Neck, NY Tel: Fax:

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Zphono Phono Preamplifier

DVI ELR Extender over one CAT5

IP6. Remote Controller Getting Started Guide. Before starting please check for the latest dlive firmware and documentation.

M-PWR User Instructions. Audiolab M-PWR english manual.in :29:02

JuiceRack & JuiceBlock 500 series Power Supplies. Operating Manual V 1.1

Z-350 FAZER USER MANUAL

music hall a70.2 integrated amplifier music hall

PREMIUMAUDIOVIDEOANDPOWERPRODUCTS V-RVC-PRO. Owners Manual

Antenna Distributor ORDERCODE D1444

USER GUIDE. Publication AP9694_2. Allen & Heath 1 XONE:K1 User Guide

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Toll Free: Tel: Fax:

FT-20 Fire Training Fog Machine User Manual English

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

Amplified subwoofer - 12" - 400W RMS

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

CANARY AUDIO CA-430. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

Blonde On Blonde OWNER S MANUAL SWR SCOTTSDALE, AZ USA

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

User Instructions. American DJ

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

Dual Channel Active Direct Box. Artcessories. User's Manual

DVI ELR Extender over one CAT5

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

RLC-1050 Power Distributor

1:4 3GSDI Splitter. User Manual EXT-3GSDI-144. Release A5

18" 600W self-powered subwoofer USER GUIDE

Compliance. Copyright 2012 GHS Corporation All Rights Reserved.

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

Model No. ET-JPF200BE

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

AudioCast Receiver Owners Manual

APT20. User Manual.

OLi POWA-5 Active Monitors

Owners' Manual Subwoofer. AP12402/5 Gale 3080 Owners' Manual (page one) Print Pantone Black for Koda

MP SERIES PROFESSIONAL POWER AMPLIFIER

Model 2380 Rack-Mount Kit

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Thank you for your purchase of the Supa-Charger! Features Include:

RMC120 SERIES. Rackmount 100V mixer-amplifier with CD player. Item ref: UK User Manual. Introduction

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

Robot Light V2. User Manual

CMSA-100 Manual. Cinema Media Server Automation

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

DT-307B Vacuum Tube Amplifier. Instruction Manual

User Manual. N Series 1U LCD Keyboard Drawer 17", 19" screen size. Models NRKD-KVM-17 / 19 Series. Models NRKDS-KVM-17 / 19 Series

1/4 Guitar / Mic input

music hall dac15.2 digital to analog converter INSTRUCTION MANUAL music hall

HP4 headphone amplifier. user manual

TourPro RGBAW Stagebar USER MANUAL

NX-50 FEATURES. Powered Speaker OWNER S MANUAL

On-Line CardioTheater Instruction Manual for Amplifier Models 800 and 1600 (wired)

LED DANCING FLOOR User Manual

VOICE-ACTIVATED INTERCOM SYSTEM

CANTEEN 6000 Portable Battery Pack NAP-30. Instruction Manual Please read carefully before use and keep for future reference.

a35.2 integrated amplifier a35.2

LED Pixel Rail Drive 640 controller. user manual

VIDAR OWNER S MANUAL STEREO OR MONO POWER AMP NOW, THAT S NOT A HINT THAT A THOR AMP IS COMING.

Transcription:

MPS12 Console Power Supply USER GUIDE Publication AP5739

Limited One Year Warranty This product has been manufactured in the UK by ALLEN & HEATH and is warranted to be free from defects in materials or workmanship for a period of one year from the date of purchase by the original owner. To ensure a high level of performance and reliability for which this equipment has been designed and manufactured, read this User Guide before operating. In the event of a failure, notify and return the defective unit to ALLEN & HEATH or its authorised agent as soon as possible for repair under warranty subject to the following conditions: Conditions Of Warranty 1. The equipment has been installed and operated in accordance with the instructions in this User Guide 2. The equipment has not been subject to misuse either intended or accidental, neglect, or alteration other than as described in the User Guide or Service Manual, or approved by ALLEN & HEATH. 3. Any necessary adjustment, alteration or repair has been carried out by ALLEN & HEATH or its authorised agent. 4. The defective unit is to be returned carriage prepaid to ALLEN & HEATH or its authorised agent with proof of purchase. 5. Units returned should be packed to avoid transit damage. In certain territories the terms may vary. Check with your ALLEN & HEATH agent for any additional warranty, which may apply. This product complies with the European Electromagnetic Compatibility directives 89/336/EEC & 92/31/EEC and the European Low Voltage Directives 73/23/EEC & 93/68/EEC. Any changes or modifications to the power supply unit not approved by Allen & Heath could void the compliance of the product and therefore the user s authority to operate it. MPS12 User Guide AP5739 Issue 1. Copyright 2004 Allen & Heath. All rights reserved Manufactured in the United Kingdom by Allen & Heath Limited Kernick Industrial Estate, Penryn, Cornwall, TR10 9LU, UK http://www.allen-heath.com 2 MPS12 User Guide

Important Safety Instructions WARNINGS - Read the following before proceeding: CAUTION ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR Read instructions: Do not remove covers: Power sources: Power cord routing: Grounding: Retain these safety and operating instructions for future reference. Adhere to all warnings printed here and on the power supply unit. Follow the operating instructions printed in this User Guide. Operate the power supply unit with its covers correctly fitted. Refer any service work on the power supply unit to competent technical personnel only. Connect the power supply unit to a mains power supply only of the type described in this User Guide and marked on the rear panel. Use only the power cord with sealed mains plug appropriate for your local mains supply as provided with the power supply unit. If the provided plug does not fit into your outlet consult your service agent for assistance. Route the power cord so that it is not likely to be walked on, stretched or pinched by items placed upon or against it. Do not defeat the grounding and polarisation means of the power cord plug. Do not remove or tamper with the ground connection in the power cord. WARNING: This equipment must be earthed. Water and moisture: Ventilation: Heat and vibration: Servicing: Installation: To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions. Do not place containers of liquid on it which might spill into any openings. Do not obstruct the ventilation slots or position the power supply unit where the air flow required for ventilation is impeded. If the power supply unit is to be operated in a flightcase, ensure that it is constructed to allow adequate ventilation. Do not locate the power supply unit in a place subject to excessive heat or direct sunlight as this could be a fire hazard. Locate the power supply unit away from any equipment which produces heat or causes excessive vibration. Switch off the equipment and unplug the power cord immediately if it is exposed to moisture, spilled liquid, objects fallen into the openings, the power cord or plug become damaged, during lightening storms, or if smoke, odour or noise is noticed. Refer servicing to qualified technical personnel only. Install the power supply unit in accordance with the instructions printed in this User Guide. Do not connect the output of power supply unit to any other equipment other than that specified by Allen & Heath. MPS12 User Guide 3

Important Mains plug wiring instructions. The power supply unit is supplied with a moulded mains plug fitted to the AC mains power lead. Follow the instructions below if the mains plug has to be replaced. The wires in the mains lead are coloured in accordance with the following code: TERMINAL WIRE COLOUR European USA/Canada L LIVE BROWN BLACK N NEUTRAL BLUE WHITE E EARTH GND GREEN & YELLOW GREEN The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or with the Earth symbol. This appliance must be earthed. The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N. The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L. Ensure that these colour codes are followed carefully in the event of the plug being changed. Precautions Damage: Environment: Cleaning: Transporting: DC power cable: To prevent damage to the power supply unit cosmetics, avoid placing heavy objects on the unit, scratching the surface with sharp objects, or subjecting the power supply unit to rough handling and vibration. Protect from excessive dirt, dust, heat and vibration when operating and storing. Avoid tobacco ash, smoke, drinks spillage, and exposure to rain and moisture. If the power supply unit becomes wet, switch off and remove power immediately. Allow to dry out thoroughly before using again. Avoid the use of chemicals, abrasives or solvents. The power supply unit is best cleaned with a soft brush and dry lint-free cloth. The power supply unit should be transported in the original packing or secured in a purpose built flightcase to protect it from damage during transit. Plan the location of the mixing console and power supply unit so that the DC power cable is not fully extended. Full extension of the cable can stress the mixing console and power supply unit connectors and may result in undesired performance. Ensure that the power cable is located such that it cannot be stood on or tripped over. 4 MPS12 User Guide

Introduction This user guide presents a quick reference to the MPS12. We recommend that you read this fully before starting. Included is information on installing, connecting and operating the power supply unit along with panel drawings and technical specification. Whilst we believe the information in this guide to be reliable we do not assume responsibility for inaccuracies. We also reserve the right to make changes in the interest of further product development. We are able to offer further product support through our worldwide network of approved dealers and service agents. You can also access our Web site (www.allen-heath.com) for information on our company and its pedigree, our full product range and our design philosophy. To help us provide the most efficient service please keep a record of your power supply unit serial number, and date and place of purchase to be quoted in any communication regarding this product. The serial number is located on the rear panel. Check the Packing Contents Retain the product packing should you need to ship the product in future. You should find the following components: 1x MPS12 POWER SUPPLY UNIT with captive DC power lead. 1x 19 FRONT PANEL. Fixes to the MPS12 for 19 rack mounting. This is supplied ready-fitted, but can be easily removed if the unit is to be used free-standing. 4x M4x8 POZI SCREWS, with 4x SHAKEPROOF WASHERS. Fix the 19 front panel to the MPS12 for 19 rack mounting. 1x IEC MAINS LEAD with moulded plug. Check that the plug is suitable for connection to your local mains supply. DOCUMENTATION including Safety Sheet AP3345, this user guide AP5739 and the Registration Card AP3594. The MPS12 The slimline MPS12 power supply unit uses switch mode technology to generate the DC voltages required by the console. It will operate from a wide range of AC mains input voltages with no change of setting required. Full protection and thermally controlled fan cooling ensures the power unit will operate consistently. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DC POWER OUT CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN OFF 0 ON I AC MAINS IN ~ 100-240V~ 47-63Hz 90W MAX ALLEN&HEATH MPS12 CONSOLE POWER SUPPLY FUSE T1.6A L 250V 20mm AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. Made in the UK by ALLEN & HEATH Limited ON Serial No. WARNING: THIS APPARATUS MUST BE EARTHED. MPS12 User Guide 5

Installation Free standing The MPS12 can be operated as a free standing unit for shelf or floor operation. Ensure adequate air flow around the unit. It must not be covered in any way. Always stand the unit on a firm flat surface well away from any soft furnishings or carpet. Rack mounting The MPS12 can be mounted in a standard 19 inch rack using the optional front panel (supplied), and will occupy 2U (3.5 inches) of rack space. An important consideration when rack-mounting the unit is the need for natural convection of airflow around the unit. Good ventilation below the unit, in the floor or back of the rack, will ensure a continuous path for airflow. Rack equipment known to produce a significant amount of heat should not be mounted directly below the power supply unit. Equipment which also relies on good airflow within the rack (i.e. most power amplifiers and other power supply units) should be given due consideration and some space should be provided between such units and the MPS12. Forced convection, by means of a fan-tray, may be desirable in some situations. Location As with any power supply unit, it is preferable to provide a degree of physical isolation of the unit from other equipment, particularly that which carries low level audio signals, to avoid any possible interference pick-up. For this reason the MPS12 power supply unit is provided with a long (2.9m) DC output cable to enable it to be positioned away from the mixing console. For the same reason, when rack-mounting it is preferable to avoid locating the unit next to signal processing equipment. Grounding Consideration must be given to the Grounding arrangement of the system, at the centre of which is the console and the MPS12. The console chassis is connected to the mains earth via the power supply unit. The MPS12 has audio 0V and mains earth connected internally. For safety it is important that all equipment grounds are connected to mains ground so that exposed metal parts are prevented from carrying high voltage which can injure or even kill the operator. Do not disconnect the ground connection in the mains lead. It is recommended that the system engineer check the continuity of the safety ground from all points in the system including microphone bodies, cable shields, equipment cases, rack metalwork and so on. If audible hum or buzz is present in the system due to a ground loop, consult the console user guide for possible solutions. Fitting in a rack The MPS12 is supplied ready for rack mounting. For free standing use, remove the 19 front panel, which is secured by four M4x8 Pozi screws and shakeproof washers. Do not obstruct the ventilation slots. Ensure adequate air flow around the MPS12. Do not install the unit directly above or below other equipment. Do not remove the cover of the MPS12. There are no user serviceable parts inside. 6 MPS12 User Guide

Operating the MPS12 Read the SAFETY INSTRUCTIONS printed in the front of this user guide and on the rear panel. The MPS12 is a high performance switch mode power supply with universal mains input. It will operate from an AC mains supply voltage from 100V to 240V. The power supply unit is provided with an IEC type mains connector and moulded mains plug. Check that this is correct for connection to your wall socket outlet. Switch the unit on by pressing the rear panel ON switch. The green ON led should light. To avoid audible thumps and bangs through the speakers, always turn the console on before switching on the amplifier system, and turn the amplifiers off before switching off the console power supply unit. Always switch the power supply unit off before connecting or disconnecting the console power cables, removing or installing console modules and any servicing work. In the event of an electrical storm, or large mains voltage fluctuations, immediately switch off the power supply unit and disconnect from the mains supply. Avoid fully extending the DC cable when plugging in as this may stress the cable and connectors resulting in failure. Ensure that walkways, aisles and gangways are not obstructed by cables. To ensure correct performance we recommend that you do not extend or modify the DC power cable in any way. Connecting the MPS12 The MPS12 may be used to power Allen & Heath consoles fitted with a compatible EXTERNAL DC IN socket. Connect the MPS12 DC POWER OUT cable to the EXTERNAL DC IN socket of the mixing console as shown below. The MPS12 should only be connected to consoles specified to work with the MPS12 by Allen & Heath. If in any doubt over its suitability for use with a particular console, please contact Allen & Heath technical support. EXTERNAL DC IN ONLY USE RECOMMENDED ALLEN&HEATH POWER SUPPLY REFER TO USER GUIDE FOR DETAILS DC POWER OUT Using the MPS12 as a Backup Power Supply The MPS12 is suitable for use as a redundant backup supply, in addition to a console s primary power source. Some smaller Allen & Heath consoles feature an MPS12 compatible EXTERNAL DC IN connector in addition to the built in mains power supply. These consoles have combiner circuitry to enable both supplies to run at the same time. In the event of a problem with one of the supplies, the other will take over seamlessly, without affecting the console s performance. The MPS12 should only be connected as a backup supply to consoles specified to work with the MPS12 by Allen & Heath. If in any doubt over its suitability for use with a particular console, please contact Allen & Heath technical support. MPS12 User Guide 7

Cleaning the Unit The MPS12 does not use any internal filters. Air is drawn through the fan grille on the side of the chassis, blown through a heatsink tunnel and out through ventilation slots in the other side of the chassis. It is not necessary to open the unit for cleaning. Simply keep the fan and ventilation slots free of dust and dirt using a vacuum cleaner and dry, lint free cloth. Do not use liquid cleaners or compressed air to clean the unit. Always switch the unit off before inspecting or cleaning it. Replacing the mains fuse The AC mains fuse is located on the rear of the MPS12 unit next to the AC mains connector. In the event of a mains surge or under-rated fuse value, the fuse will rupture. Switch off the power supply and remove the mains lead plug from the AC MAINS IN~ socket on the rear of the unit. Check the fuse and replace if necessary. In the event of repeated failure of the mains fuse, consult your Allen & Heath service agent. In the unlikely event of an internal DC rail fuse failure, consult your Allen & Heath service agent or Allen & Heath technical support. TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS INDICATED ON THE UNIT. AC~ mains input voltage 100V 240V ± 10% Fuse type T 1.6A L 250V 20mm Technical specification Internal universal input switch mode power unit. MAINS IN socket IEC 3 pin Power lead Country dependent with moulded mains plug supplied AC mains 100 to 240V AC @ 50/60Hz auto sensing Consumption 90W max Mains fuse rating 100-240V AC T 1.6A L 250V 20mm (A&H part number: AL0466) Overall Dimensions: Mains Leads: 19 Front Panel: 483mm x 88mm 19 inch 2U Chassis 218mm x 55mm 8.6 inches Height including feet: 59mm 2.3 inches Depth: 147mm 5.8 inches Weight: 1.6kg 3.5 lbs Territory Voltage A&H Part no: USA 100-120V AH0323 Europe 220-230V AH0205 UK 240V AH0206 8 MPS12 User Guide