Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts

Similar documents
3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Auxiliary Contacts

Safety Switches 3-1. General. 3-Interlock. Switches. Operator. Interface. Logic. Power. Safety Switches Table of Contents. 2-Opto-electronics

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard

Tongue Switches Trojan 5 & 6

SensaGuard. Description. Features. Benefits. Specifications

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Inputs. Switching Voltage, Min. Conductor Size, Max.

MSR178DP. Description. Features. Specifications

MSR42 Micro 400 Controller/Muting Module

SafeC S to MSR127 Conversion

4-20 Visit our website: Emergency Stop. Devices. Stop Devices. 4-Emergency. Operator Interface Enabling Switches Overview

Standard actuator 440K-A Standard actuator 440G-A Fully flex actuator 440G-A07269

Safety Interlock Switches

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

802B Compact, Precision and Small Precision

Safety Light Curtains GuardShield Remote Teach

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

Datasheet - RSS 36-D-R-ST

Compact Coded Magnetic Safety Interlock Switch and Control Units

Safety switches for hinged doors

Presence Sensing Safety Devices

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

Versatile Safety Interlock Switch with Guard Door Locking

Datasheet - AZM300Z-ST-1P2P-A

Universal Tongue-Operated Safety Interlock Switch

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Magnetically Actuated Safety Interlock Switches

Safety Switches CES-AR/CET-AR

SR B series coded magnetic safety sensors

Interlock. Mode Activation Button. Fixed Blanking. 2 Beam Floating Blanking (14 mm only)

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

SensaGuard 18 mm Barrels

SAFETY LOCKING DEVICES

Bulletin 871D Cylinder Position Inductive Style

Sensor boxes SRBG Key features

Safety switches with separate actuator

Safety coded magnetic sensor SR B series

Limit Switches E47 Precision Switches

Safety switches with separate actuator

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Coded magnetic safety sensor SR B series

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Magnetic Non-contact Safety Switches. Model Number Structure

Pneumatic Control/Feedback

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Datasheet - AZM 200 BZ ST-T-AS P

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Magnetically Actuated Safety Interlock Switches

Datasheet - AZM 200SK-T-1P2PW

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

SR A series coded magnetic safety sensor

Safety coded magnetic sensor SR A series

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

Datasheet - MZM 100 B ST-1P2PW2REM-A

Conveyor Belt Alignment Switches from IDEM

Datasheet - AZ 16-02ZVK

SMARTSCAN INFORMATION

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Safety switches with separate actuator

Datasheet AZM 161 Z ST1 AS RA

Safety Systems Safety Integrated

RM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs

Datasheet - AZ 16-03ZVRK

Bulletin 871L & 872L Limit Switch Style

Rotary Position Technology Incremental Encoders

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Datasheet - AZ 16-02ZVRK-ST

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Manually Operated Bolt Safety Interlock Switch. NEMA 6 enclosure enables the BL6009 switch to withstand water washdown cleaning

Datasheet - AZ 16ZVRK

Hinged safety switches, Palladio line

the Interactive Catalog

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Safety Monitoring Relays

Contents. Volume 8 Sensing Solutions CA E February

Datasheet - AZ 15 ZVRK

Pneumatic Control/Feedback

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety coded magnetic sensor SR A series

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety coded magnetic sensor SR B series

Universal Compact Extruded Cylinders

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Datasheet - AZ 15 ZVK

Guardmaster Safety Relays DI, DIS, SI, CI, GLP, EM, And EMD

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

Transcription:

Interlock Hinge Sprite General 1-2-Opto-electronics 3-Interlock Logic Power The Sprite is a hinge-actuated safety interlock switch in a compact housing only 75 x 25 x 29 mm (2.95 x 0.98 x 1.14 in.) making it the smallest interlock currently available. The Sprite has been designed for smaller machines such as printing machines, copiers and domestic machinery, which until now, have been able to use standard safety interlocks due to space restrictions. Despite its small size, the Sprite includes the necessary safety-related functions, such as forced-guided contacts and a tamper-resistant mechanism allowing machinery to be safeguarded in compliance with the machinery directive. The shaft of the Sprite is connected to the existing hinge pin and the degree of operation can be adjusted to suit the application via the adjustable cam in the switch head. IMPOTANT: After adjustment, the cam must be secured in position with the supplied cam locking pin to ensure optimal performance. Features Ideal for small, light-weight guards The smallest hinge interlock switch available, 75 x 25 mm case Degree of operation can customized with adjustable cam Contacts, 2 N.C. or 1 N.C. & 1 N.O. Four possible shaft positions, easy to install Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit http://www.ab.com/safety/ Certifications Outputs Safety Contacts EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 device per EN 954-1 May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics CE Marked for all applicable directives, culus NTL/C and TÜV 2 N.C. directopening action 1 N.C. directopening action Auxiliary Contacts 1 N.O. Shaft otation for Contact Operation Maximum 11 ; Minimum 3 (adjustable) Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Current @ Voltage, Min. 5 ma @ 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Break Contact Force, Min. 8 cnm (torque on shaft) Actuation Speed, Max. 160 mm (6.29 in.)/s Actuation Frequency, Max. 1 cycle/s Operating Life @ 100 ma load 1,000,000 operations Environmental Enclosure Type ating IP67 Operating Temperature [C (F)] -20 +80 (-4 176 ) Physical Characteristics Housing Material UL Approved glass-filled PBT Shaft Material Stainless Steel Weight [g (lb)] 80 (0.176) Color ed Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. 3-90

Interlock Hinge Sprite Product Selection Contact uxiliary Action 2 N.C. 1 N.C. 1 N.O. BBM For connector ratings, see page 3-9. Shaft Type Solid Pre-Bored Solid Pre-Bored Actuator Shaft Dimensions mm (in) M16 M16 Conduit 1/2 inch NPT Adaptor Cat. No. 4-Pin Micro (M12) Connector Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) 80 x Ø10 (3.14 x 0.39) 440H-S34019 440H-S34023 440H-S34027 60 x Ø8 (2.36 x 0.31) 440H-S34020 440H-S34024 440H-S34028 50 x Ø10(1.96 x 0.39) 440H-S34010 440H-S34017 440H-S34014 440H-S2NNPPS 30 x Ø16 (1.18 x 0.63) bore Ø9.5 (0.37) 440H-S34033 440H-S34034 440H-S34035 440H-S2NNHPS 80 x Ø10 (3.14 x 0.39) 440H-S34021 440H-S34025 440H-S34029 60 x Ø8 (2.36 x 0.31) 440H-S34022 440H-S34026 440H-S34030 50 x Ø10(1.96 x 0.39) 440H-S34012 440H-S34018 440H-S34015 30 x Ø16 (1.18 x 0.63) bore Ø9.5 (0.37) 440H-S34036 General 1- ecommended Logic s Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Cat. No. Single-Function Safety elays MS127P 3 N.O. 1 N.C. emovable (Screw) 24V AC/DC 5-26 440-N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC 5-26 440-N23132 MS9T 2 N.O. 1 N.C. Fixed Auto./Manual 24V AC/DC 5-14 440-F23027 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or 24V DC 5-16 440-N23198 MS33T 2 N.O. Solid State 1 N.O. emovable Auto. or Monitored Manual 24V DC SELV 5-18 440-F23200 Modular Safety elays MS210P Base 2 N.C. only MS220P Input Module MS310P Base MS320P Input Module 2 N.O. 1 N.C. and 2 PNP Solid State emovable Auto./Manual or 24V DC from the base unit 5-82 440-H23176 emovable 24V DC 5-86 440-H23178 MS300 Series Output Modules 3 PNP Solid State emovable Auto./Manual 2 PNP Solid State emovable 24V DC 5-102 440-W23219 24V DC from the base unit 5-106 440-W23218 2-Opto-electronics 3-Interlock Note: For additional Safety elays connectivity, see page 5-12. For additional Safety I/O and Safety PLC connectivity, see page 5-116. For application and wiring diagrams, see page 10-1. Connection Systems 5-Pin Micro (M12) for ArmorBlock 4-Pin Micro (M12) Guard I/O 2 N.C. 1 N.C. & 1 N.O. 2 N.C. Cordset 889D-F4AC- 889D-F4AC- Patchcord 889D-F4ACDM- 889D-F4ACDM- 889D-F5ACDM- Distribution Box 889D-4 LT-DM4 898D-F4 KT-DM4 Shorting Plug 889D-41LU-DM 898D-41KU-DM T-Port 889D-43LY-D4 898D-43KY-D4 eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 4 or 8 for number of ports. Note: For additional information, see the Safety Connection System section (page 7-1) of this catalog. Logic Power 3-91

Interlock Hinge Sprite Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. # = mm (in) General 1-2-Opto-electronics 3-Interlock 1 x M16 12.5 (0.49) Hollow Shaft 18 (0.71) 2 x M4 16.5 (0.65) A, Ø B 10 (0.39) 80 (3.14) mm (in) 8 (0.31) 60 (2.36) 10 (0.39) 50 (1.96) 3 (0.12) 34.5 (1.36) 36 (1.42) 2 holes 3.2 (0.12) Dia. 13 (0.51) 8 (0.31) Note: 2D, 3D and electrical drawings are available on www.ab.com. 29 (1.14) 12.5 (0.49) 5 (0.2) 30 (1.18) 75 (2.95) 25.5 (1.0) 12.5 (0.49) 5 (0.2) 9.5 (0.37) Dia. 2 holes M4 in line 16 (0.63) Dia. 3 (0.12) B 25 (0.98) A Logic Power 3-92 Visit our website: www.ab.com/catalog

Typical Wiring Diagrams 1 N.C. & 1 N.O. 2 N.C. Interlock Hinge Sprite 1-2-Opto-electronics 3-Interlock Power Logic General Contact Configuration 11 12 (NC) 11 12 (NC) 23 24 (NO) 21 22 (NC) Contact Action 6 3.3 Open Closed 3.8 0 mm 2-6 3.3 0 mm 2-4-Pin Micro (M12) 5-Pin Micro (M12) For ArmorBlock Guard I/O Cordset 889D-F4AC- Brown Blue White Black 1-4- eplace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths. 3-1- 4-5- 3-N/A 3-2- 1-4- 3-93

Interlock Hinge Ensign 3 General 1-2-Opto-electronics 3-Interlock Logic Power The Ensign 3 is a hinge-actuated safety-interlock switch designed to fit at the hinge point of guards. With its rotatable head, the versatile Ensign 3 offers up to four different mounting options. Operation of the unit is achieved by the hinging action of the guard. The actuation shaft is connected to the existing hinge pin and the degree of operation can be adjusted to suit the application via the adjustable cam in the switch head. IMPOTANT: After adjustment, the cam must be secured in position with the supplied cam locking pin to ensure safety function performance. The switch includes the necessary safety-related functions, such as forced-guided contacts and a tamper-resistant mechanism, allowing machinery to be safeguarded in compliance with the machinery directive. It is sealed to IP67 and has one conduit entry, M16 or connector style. Features Compact size 90.5 x 31 x 30.4 mm (3.56 x 1.22 x 1.2 in) housing Ideal for small, lightweight guards Degree of operation can be customized with adjustable cam Contacts, 2 N.C. & 1 N.O. or 3 N.C. (sealed to IP67) Four possible shaft positions, easy to install Solid and hollow shafts available Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit http://www.ab.com/safety/ Certifications Outputs Safety Contacts EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics CE Marked for all applicable directives, culus, and TÜV 3 N.C. directopening action 2 N.C. directopening action Auxiliary Contacts 1 N.O. 3 N.C. Adjustable 12 max.: 3 min. 2 N.C. 1 N.O. (BBM) Adjustable Shaft otation for Contact Operation 14 max.: 5 min. 2 N.C. 1 N.O. (MBB) Adjustable 12 max.: 3 min. Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Current @ Voltage, Min. 5 ma @ 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Break Contact Force, Min. 8 cnm (torque on shaft) Actuation Speed, Max. 160 mm (6.29 in.)/s Actuation Frequency, Max. 1 cycle/s Operating Life @ 100 ma load 1,000,000 operations Environmental Enclosure Type ating IP67 Operating Temperature [C (F)] -20 +80 (-4 176 ) Physical Characteristics Housing Material UL Approved glass-filled PBT Shaft Material Stainless Steel Weight [g (lb)] 100 (0.22) Color ed Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. 3-94

Interlock Hinge Ensign 3 Product Selection Contact uxiliary Action 3 N.C. 2 N.C. 1 N.O. BBM MBB Actuator Shaft Dimensions mm (in) 80 x Ø10 (3.14 x 0.39) Shaft Type M16 M16 Conduit 1/2 inch NPT Adaptor Cat. No. 6-Pin Micro (M12) Connector Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) 440H-E22025 440H-E22050 440H-E22059 60 x Ø8 (2.36 x 0.31) Solid 440H-E22031 440H-E22051 440H-E22060 50 x Ø10 (1.96 x 0.39) 440H-E22047 440H-E22052 440H-E22061 440H-E2NNPPS 30 x Ø16 (1.18 x 0.63) bore Ø9.5 (0.37) 80 x Ø10 (3.14 x 0.39) Pre-bored 440H-E22067 440H-E22068 440H-E22069 440H-E2NNHPS 440H-E22027 440H-E22053 440H-E22037 60 x Ø8 (2.36 x 0.31) Solid 440H-E22033 440H-E22054 440H-E22039 50 x Ø10 (1.96 x 0.39) 440H-E22048 440H-E22055 440H-E22062 30 x Ø16 (1.18 x 0.63) bore Ø9.5 (0.37) 80 x Ø10 (3.14 x 0.39) Pre-bored 440H-E22064 440H-E22065 440H-E22066 440H-E22029 440H-E22056 440H-E22038 60 x Ø8 (2.36 x 0.31) Solid 440H-E22035 440H-E22057 440H-E22040 50 x Ø10 (1.96 x 0.39) 440H-E22049 440H-E22058 440H-E22063 30 x Ø16 (1.18 x 0.63) bore Ø9.5 (0.37) With a 5-pin micro (M12) connector, not all contacts are connected. See page 3-97 for wiring details. For connector ratings, see 3-9. ecommended Logic s Pre-bored 440H-E22070 440H-E22071 440H-E22072 Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Cat. No. Single-Function Safety elays MS127P 3 N.O. 1 N.C. emovable (Screw) 24V AC/DC 5-26 440-N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC 5-26 440-N23132 MS126T 2 N.O. None Fixed Auto./Manual 24V AC/DC 5-24 440-N23117 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or 24V DC 5-16 440-N23198 Modular Safety elays MS210P Base 2 N.C. only MS220P Input Module MS310P Base MS320P Input Module 2 N.O. 1 N.C. and 2 PNP Solid State emovable Auto./Manual or 24V DC from the base unit 5-82 440-H23176 emovable 24V DC 5-86 440-H23178 MS300 Series Output Modules 3 PNP Solid State emovable Auto./Manual 2 PNP Solid State emovable Note: For additional Safety elays connectivity, see page 5-12. For additional Safety I/O and Safety PLC connectivity, see page 5-116. For application and wiring diagrams, see page 10-1. 24V DC 5-102 440-W23219 24V DC from the base unit 5-106 440-W23218 General 1-2-Opto-electronics 3-Interlock Connection Systems Connections to ArmorBlock Guard I/O 6-Pin Micro 5-Pin Micro (M12) 3 N.C.-2 N.C. & 1 N.O. 3 N.C. Cordset 889-F6ECA- Patchcord 889-F6ECM- 889D-F5ACDM- Distribution Box 898-P68MT-A5 Shorting Plug 898-P61MU-M Logic eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Note: For additional information, see page 7-1. Power 3-95

Interlock Hinge Ensign 3 Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. 2 x M4 1 x M16 General 1-2-Opto-electronics 3-Interlock 31 (1.22) A, Ø B 10 (0.39) 80 (3.14) mm (in) 8 (0.31) 60 (2.36) 10 (0.39) 50 (1.96) 90.5 (3.56) Hollow Shaft 34.4 (1.35) 36.4 (1.43) 38.4 (1.51) 20 (0.79) 22 (0.87) 25 (0.98) 2 holes 3.2 (0.12) Dia. 13 (0.51) 8 (0.31) Note: 2D, 3D and electrical drawings are available on www.ab.com. 13 (0.51) 5 (0.2) 30 (1.18) 2 holes M4 in line 25.5 (1.0) 16 (0.63) Dia. 5 (0.2) 9.5 (0.37) Dia. 12.5 (0.49) 3 (0.12) B A 25 (0.98) 30.4 (1.2) Logic Power 3-96 Visit our website: www.ab.com/catalog

Typical Wiring Diagrams 2 N.C. & 1 N.O. 3 N.C. Interlock Hinge Ensign 3 Power Logic 1- General Contact Configuration 11 12 11 12 21 22 21 22 33 34 31 32 Safety C Contact Action Open 5-Pin Micro (M12) For ArmorBlock Guard I/O 6-Pin Micro (M12) Cordset 889-F6ECA- Closed 1 ed/white 5 ed/black 2 ed 6 ed/blue 3 Green 4 ed/yellow 3-4- 5-5 6 BBM 4 MBB eplace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths. 3 0 0 6-2- 1- Safety C 5-4-Safety C 3-NA 2-Opto-electronics 3-Safety C 5-3-Interlock Safety C 5 0 2-1- 4-6- 2-1- 3-97

Interlock Hinge otacam General 1-2-Opto-electronics 3-Interlock Logic Power The otacam is heavy-duty, hinge-actuated safety-interlock switch. It can be used as, or connected to, the existing hinge pin for direct operation of the switch. Machine power is isolated when the guard has been opened just 5. For applications requiring a larger degree of operation, the internal cam can be adjusted from 5 11. IMPOTANT: After adjustment, the cam must be secured in position with the supplied cam locking pin to ensure optimal performance. The otacam is available with two N.C. safety contacts and one N.O. auxiliary contact. The switch includes the necessary safetyrelated functions, such as forced-guided contacts and a tamperresistant mechanism, allowing machinery to be safeguarded in compliance with the machinery directive. The die-cast housing is sealed to IP66 and features one M20 conduit entry (1/2 inch NPT and connector style also available). Two different shaft lengths of 30 mm and 85 mm can also be specified. EX and Pneumatic styles of otacam are also available; see page 9-10 for more information. Features Can be used as a hinge pin on light- and medium-weight guard doors Isolates power within 5 of door movement Degree of operation can be customized with adjustable cam obust die-cast case, ideal for heavy-duty applications Contacts, 2 N.C. & 1 N.O. Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit http://www.ab.com/safety/ Certifications EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics CE Marked for all applicable directives, culus, SUVA, and TÜV Outputs Safety Contacts 2 N.C. direct opening action Auxiliary Contacts 1 N.O. Shaft otation for Contact Operation 11 maximum; 5 minimum, (adjustable) Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Current @ Voltage, Min. 5 ma @ 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Break Contact Force, Min. 12 cnm (torque on shaft) Actuation Speed, Max. 160 mm (6.29 in.)/s Actuation Frequency, Max. 1 cycle/s Operating Life @ 100 ma load >1,000,000 operations Environmental Enclosure Type ating IP66 Operating Temperature [C (F)] -20 +80 (-4 176 ) Physical Characteristics Housing Material Heavy-duty die-cast alloy Shaft Material Stainless Steel Weight [g (lb)] 420 (0.926) Color ed Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. 3-98

Interlock Hinge otacam Product Selection Safety Contacts Auxiliary Contacts Contact Action Shaft Dimensions Operating Shaft Type 2 N.C. 1 N.O. BBM For connector ratings, see 3-9. L = 30 (1.18) D = 16 (0.63) L = 85 (3.35) D = 12.7 (0.5) Pre-Bored Solid M20 M20 Conduit Cat. No. 1/2 inch NPT Adaptor Connector 8-Pin Micro (M12) 440H-03074 440H-03078 440H-03111 440H-03079 440H-03088 440H-03112 General ecommended Logic s Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Cat. No. Single-Function Safety elays MS127P 3 N.O. 1 N.C. emovable (Screw) 24V AC/DC 5-26 440-N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC 5-26 440-N23132 MS126T 2 N.O. None Fixed Auto./Manual 24V AC/DC 5-24 440-N23117 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or 24V DC 5-16 440-N23198 Modular Safety elays MS210P Base 2 N.C. only MS220P Input Module MS310P Base MS320P Input Module 2 N.O. 1 N.C. and 2 PNP Solid State emovable Auto./Manual or 24V DC from the base unit 5-82 440-H23176 emovable 24V DC 5-86 440-H23178 MS300 Series Output Modules 3 PNP Solid State emovable Auto./Manual Monitored Manual 2 PNP Solid State emovable 24V DC 5-102 440-W23219 24V DC from the base unit 5-106 440-W23218 1-2-Opto-electronics Note: For additional Safety elays connectivity, see page 5-12. For additional Safety I/O and Safety PLC connectivity, see page 5-116. For application and wiring diagrams, see page 10-1. Connection Systems 8-Pin Micro (M12) 2 N.C. & 1 N.O. Cordset 889D-F8AB- Patchcord 889D-F8ABDM- Distribution Box Shorting Plug T-Port eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Note: For additional information, see page 7-1. 3-Interlock Power Logic 3-99

Interlock Hinge otacam General 1-2-Opto-electronics 3-Interlock Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. 3.5 (0.14) 24 (0.94) M4 14.5 (0.57) 6.5 (0.26) 36 (1.42) 52 (2.05) M5 Tapped 99 (3.9) 23.5 (0.93) 86 (3.39) 25 (0.98) 2 x M4 (otacam HS-2) 13 (0.51) 8 (0.31) Note: Holes only on pre-bored models. Note: 2D, 3D and electrical drawings are available on www.ab.com. "A" "A" M4 5 (0.2) 6.5 (0.26) 65 (2.56) # = mm (in) otacam HS-2 otacam P85 Ø 9.5 (0.37) M5 Tapped Ø 3.2mm (0.13) 15.5 (0.61) 6.5 38 (1.5) (0.26) L L 30mm (1.18) 85mm (3.35) D 16mm (0.63) 12.7mm (0.5) D Logic Power 3-100 Visit our website: www.ab.com/catalog

Interlock Hinge otacam Typical Wiring Diagrams 2 N.C. & 1 N.O. 1- Power 2-Opto-electronics Logic 3-Interlock General Contact Configuration 11 12 21 22 33 34 Contact Action Open 8-Pin Micro (M12) Pin 2 Not Connected 8-Pin Cordset 889D-F8AB- Closed White Blue Grey Pink Green Yellow ed Brown eplace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths. 3-8-Ground 4-5- 6 Ground Not Connected 5 0mm 2-N/A 1-7- 6-3-101