Hinged safety switches, Palladio line

Similar documents
Safety hinge switches HX series

Safety switches for hinged doors

HP-HC series safety hinge switches

Hinged-shaped safety switches in stainless steel, HX series

Safety switches with separate actuator

Safety switches with separate actuator

Safety switches with separate actuator

Position switches FD series

Safety switches with manual mechanical delay and separate actuator

Position switches FD series

Safety hinge switches HX series

Safety hinge switches HP-HC series

Microswitches MS Series

Safety switches with manual mechanical delay and separate actuator

Safety coded magnetic sensor SR B series

SR B series coded magnetic safety sensors

Safety coded magnetic sensor SR A series

Coded magnetic safety sensor SR B series

SR A series coded magnetic safety sensor

Safety coded magnetic sensor SR B series

Single contact blocks

Safety coded magnetic sensor SR A series

Safety switches with solenoid and separate actuator

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE

Safety Switches with Separate Actuator, Metal Housing

VF CNM5MM-L100. Accessories. M12 male connectors. Code structure. M 12x1

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Datasheet - ZR Z

Datasheet - AZ 15 ZVRK

Datasheet - RSS 36-D-R-ST

Incremental Encoder with Hollow Shaft

illuminated button R S P F flush projecting protected mushroom white red green yellow blue orange black

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVRK

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - AZ 15 ZVK

Datasheet - AZ 15 ZVRK

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-03ZVRK

Datasheet - AZ 16-02ZVRK-ST

Current DC (ma) Storage Temp. ( C) Red 1.85 Vdc D. Voltage Vac/dc

Datasheet - AZ 16ZVRK

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

K1B004TLH cam switch - 1 pole A - screw mounting

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Datasheet - ZS Z

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Switches and Indicators 84

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

APS4 Inductive Proximity Sensors

Joystick E2 MA series

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

Datasheet - ZR Z

Vandal-proof latching action switch MSM LA

NEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

industrial panel lamps

Single buttons. Selection diagram. 31 General Catalogue HMI BUTTON. illuminated button TYPE. R S P F flush projecting protected mushroom

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Operating instructions Evaluation system for flow sensors VS / / 2013

K1F006ALH cam switch - 6-pole A - screw mounting

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

JULIET-PK. Joystick station

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

C5 Series Stainless Steel Photoelectric

SUBMINIATURE MICROSWITCHES - SEALED

Dual Voltage Shaver Socket

ZB5FG09 flush mounted selector switch head key pos stay put

SAFETY COMMAND DEVICES

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

Devices raised mounting

SAFETY SWITCHES. Phone: Fax: Web: S20 Safety Switch

SACB-8/16-L-C GG SCO. Extract from the online catalog. Order No.:

Mating connectors and cable sets for valves and sensors in hydraulics

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

F3ET Lightcurtain in robust aluminium housing

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches

20A Control Switches

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Analog micro push button

XCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m

Tongue Switches Trojan 5 & 6

Note: KLASCHKA КB WIDENT/P 1/9

Pushbuttons, Switches and Pilot Devices

FE Series Photoelectric Sensors

Magnetically Actuated Safety Interlock Switches

Juliet - PK. Joystick station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting.

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

Transcription:

Hinged safety switches, Palladio line Selection diagram CONTACT BLOCKS 0C 0F 0M C F M snap action snap action snap action C F M CABLE AND CONNECTORS S A P KSM KAM Cable output Cable output M connector from top from back from bottom Cable output from bottom (standard) M connector from top COLOURS COMPLEMENTARY HINGES Note: Special colouring only for high quantity request Contact our sales office. HC LL HC AA FIXING PLATES VF SFH-C VF SFH-C VF SFH-C VF SFH-C page /9 General Catalog 00-008

Hinged safety switches, Palladio line Application examples Switch without supports Rear fixing Cable output from back Switch with angular supports for profiles with slots Fixing through internal screws Connector output from bottom Switch with plane supports for profiles with slots Fixing through front screws Cable output from bottom Code structure Contact block 0C, snap action 0F, snap action 0M, snap action C, F, M, C, F, M, article option HP AA00C-SNG Contacts type silver contacts (standard) G silver contacts gold plated µm Type of cable or connector N cable EN 0- black (standard) G cable CEI 0- II grey ( contacts block only) H cable PUR halogen free grey ( contacts block only) M M connector Type of connection cable length m cable length m...... 0 cable length 0 m K with connector Connection output direction S from bottom P from back (cable versions only) A from top COMPLEMENTARY HINGES Code Hinge length HC LL mm HC AA 00, mm General Catalog 00-008 page /0

Hinged safety switches, Palladio line Technical data Housing Metal housing, coated with baked epoxy powder Version with cable integrated with x 0, mm, x 0, mm o 9 x 0, mm wires length m, other lengths on request. Versions with M or 8 poles integrated connector Protection degree: IP screws max driving torque:... Nm Main data New product 00 Metal housing, cable output from top, bottom or back integrated cable types available Versions with M connector Protection degree IP 9 contact blocks with positive opening Complementary hinges without contacts General data Ambient temperature: See table on page / Max operating frequency: 0 operations cycles /hour Mechanical endurance: million operations cycles Max actuating speed: 90 /s Min. actuating speed: /s Assembling position: any Max axial charge: 00 N (preliminary data) Max radial charge: 000 N (preliminary data) () One operation cycle means two movements, one to close and one to open contacts, as foreseen by IEC 09- - standard. In conformity with standards: IEC 09--, EN 09--, IEC 00-, EN 00-, EN 088, EN ISO 00-, EN ISO 00-, IEC 9, EN 09. Markings and quality marks: In conformity with requirements requested by: Low Voltage Directive 00/9/EC, Machinery Directive 00//EC and Electromagnetic Compatibility 00/08/EC. Positive contact opening in conformity with standards: IEC 09--, EN 09--, VDE 00-0. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page / to page /8. Utilization temperatures Ambient temperature: min. max. Thermal current Ith Rated insulation voltage (Ui): Protection against short circuits (fuse) V Utilization category AC 0 V 0 V 00 V Utilization category DC V V 0 V Version with contacts, fixed laying cable (N, G, U cable) - C +0 C 0 A 00 VAC 0 A 00 V A A A A A 0, A 0, A Version with contacts, dynamic laying cable (H cable) -0 C +80 C 0 A 00 VAC 0 A 00 V A A A A A 0, A 0, A Version with contacts, fixed laying cable (N cable) - C +80 C A 00 VAC A 00 V A A A A A 0, A 0, A Version with contacts, fixed laying cable (N cable) - C +80 C A 00 VAC A 00 V A A A A A 0, A 0, A Version with contacts, poles M connector -0 C +80 C A 0 VAC 0 VDC A 00 V A A A / A 0, A 0, A Version with or contacts, 8 poles M connector -0 C +80 C A VAC VDC A 00V A / / / A / / page / General Catalog 00-008

Hinged safety switches, Palladio line Application field Pizzato Elettrica widens the own range of products making a new series of safety switches hingeshaped named Palladio, where safety and style are melted in one single product. The switch is completely integrated in the mechanical hinge, to result practically invisible to an inexpert eye. This guarantees a higher safety because a switch hard to identify is consequently also more difficult to defeat. The assembly without visible screws and the pleasant line, make the switch perfectly integrated also with guards of modern design machinery. In order to complete the offer complementary hinges with purely mechanics functions are available. Operating point regulation The switches operating point can be regulated through a simple Phillips screwdriver. The operating point regulation allows the setting possibility (up to ) for large guards. After the setting, it s always necessary to close the hole through the suitable supplied safety seal plug. M integrated connector version Versions with connection from the top or the bottom are available with M integrated connector. The application of versions with connector allows a faster wiring when it s necessary to move guards from test line to final user. Opening angle up to 80 The mechanical design of the switch allows the application also onto protections up to 80 opening angle. INNOVATION & DESIGN AWARD 00 This product has been presented at the Innovation & Design award 00 which selects, among all industrial products, those that stand out for technological innovation and their particular design. The switch has been selected by the jury in category Innovation during the fair Enermotive 00. Internal connections With cable () With cable () With cable () With M connector with 8 poles () With M connector with 8 poles () With M connector with poles () black black-white red red-white brown blue violet violet-white black black-white red red-white brown blue yellow-green black grey brown blue yellow-green 8 8 8 8 yellow-green Attention! According to EN 00-, versions with 8 poles M connector can be used only in circuits PELV. General Catalog 00-008 page /

M Hinged safety switches, Palladio line Dimensional drawings Contacts type: R = snap action L = LO = version with m cable from bottom version with m cable from top version with m cable from back 8.9 Ø.. Contact blocks 9 9 9 0C R 0F R 0M R C L F L M L C LO F LO M LO Min. force Travel diagrams HP AA00C-SN HP AA00F-SN HP AA00M-SN HP AA0C-SN HP AA0F-SN HP AA0M-SN HP AA0C-SN HP AA0F-SN HP AA0M-SN page / - group HP AA00C-AN HP AA00F-AN HP AA00M-AN HP AA0C-AN HP AA0F-AN HP AA0M-AN HP AA0C-AN HP AA0F-AN HP AA0M-AN page / - group HP AA00C-PN HP AA00F-PN HP AA00M-PN HP AA0C-PN HP AA0F-PN HP AA0M-PN HP AA0C-PN HP AA0F-PN HP AA0M-PN page / - group Contacts type: R = snap action L = LO = version with M connector from bottom version with M connector from top Mx 0. Travel diagrams table Contact blocks Group M M 0C 0F 0 8 80. 0 8 80. 0. M x 0M 0. 8 80 Contact blocks 0C R 0F R 0M R C L F L M L C LO F LO M LO Min. force Travel diagrams HP AA00C-KSM HP AA00F-KSM HP AA00M-KSM HP AA0C-KSM HP AA0F-KSM HP AA0M-KSM HP AA0C-KSM HP AA0F-KSM HP AA0M-KSM page / - group 9 HP AA00C-KAM HP AA00F-KAM HP AA00M-KAM HP AA0C-KAM HP AA0F-KAM HP AA0M-KAM HP AA0C-KAM HP AA0F-KAM HP AA0M-KAM page / - group 9 C F M C F M 0 80 0 80 0 80 0 80 0 80 0 80 Attention! The hinged safety switch can be combined together exclusively with one or more Pizzato Elettrica hinges (series HP or HC). The use of whichever other hinge does not guarantee the right working of the safety device. page / General Catalog 00-008

Hinged safety switches, Palladio line Complementary hinges AC 0 Protection plug of regulation screw The plug is supplied with every hinge and must always be inserted after the operating point regulation. In case of loss or damage, the plug can be ordered separately. 9 HC AA. HC LL Fixing plates Fixing screw for profile not supplied on issue VF SFH-C Couple of angular supports for HP AA and HC AA supplied with fixing screws for switch VF SFH-C Couple of angular supports for HC LL supplied with fixing screws for switch.. 0 8. 8. 0 0. 8.. 8. 0. 0 9 max max 0 0..... 0.. M. M VF SFH-C Couple of plane supports for HP AA and HC AA supplied with fixing screws for switch VF SFH-C Couple of plane supports for HC LL supplied with fixing screws for switch 0 9 80 8.. 8 8.. 8 Accessories See page / Items with code on the green background are available in stock General Catalog 00-008 page /