Operation and Installation Manual

Similar documents
Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating Instructions VEGAMET 381

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions. Speed monitor D / / 2014

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Assembly and Operating Instructions. NFC module for BDC-i440 control units

Roto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

P5/20M - P13/9M R7/17M - L120/11M

Installation instructions Inclination sensor EC2019 EC / / 2013

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Operating instructions Optical distance sensor. OID25x / / 2014

B63/ NS MS. EtherNet/IP LINK

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions. Standstill monitor A / / 2011

Operating Instructions

HST -S1 Switching element (Translation of Original Manual)

Flow Sensor SONOFLOW CO.55

Dialock DT Lite. Operating instructions...2. Operating instructions

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Operating Manual FPGA-based High-Speed Micro-PLC

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Display Panel BAT 100 LSN. en Operation Guide

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Installation and Maintenance

DuoFern Multiple Wall Controller

Operating instructions Optical distance sensor. OID20x / / 2015

Installation Manual BAK02

Operating instructions Safety sensor BNS About this document. Content

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Operating instructions Safety sensor BNS About this document. Content

LED-Illumination with Control Unit Ident.-No

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Vibration Sensor Type 640

Supplementary operating instructions for your air curtain system Controller TMC 500

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Sliding shutter control Aluminium shutters

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

Technical Manual Room temperature controller

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Installation manual plugs and connectors with screw connection (16/32 A)

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Tina 1A Blanking plug

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Assembly and Operating Instructions Tubular drives for sunshades

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

MDM 011-Z1 Regen Resistor

Assembly and Operating Instructions Door Control

Operating instructions

Demonstration Case BENNING DB 1

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Operating Instructions Wall saw WSE1217 USA

Operation Manual Locator Wöhler L 200

OPERATING INSTRUCTIONS

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

MSI-RM2 Safety Relays

Operating Instructions Drill rigs DRU400 DRA400

Interface and Supply module. IPC 3x0i / PSC 3x0i

Push button UP 287, 4 - fold

Operating Manual -ENGLISH- Page 1 KWG-ISO

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Operating Instructions

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Weatherproof IR Color Day/Night Cameras

Transcription:

Operation and Installation Manual SmartLINK M 13 x

Content 1 Document Content...1 1.1 Function...1 1.2 Target group: Authorised personnel...1 1.3 Symbols and abbreviations used...1 1.4 Proper use...2 1.5 General notes on safety...2 1.6 Warning of misuse...2 1.7 Disclaimer...2 2 Product Description...3 2.1 Type code...3 2.2 Terms and conditions and use...3 2.3 Technical data...3 3 Assembly...5 3.1 General notes on assembly...5 3.2 General notes on electrical connection...10 4 Commissioning and Maintenance...11 4.1 Commissioning and function test...11 4.2 Maintenance...11 5 Disassembly and Disposal...12 5.1 Disassembly...12 5.2 Disposal...12 6 Scope of Supply...12 7 Attachment...13 8 Declaration of Conformity...15 8.1 Declaration of ECconformity...15

1 Document Content 1.1 Function This operating instructions manual provides necessary information on installation, commissioning, safe operation, disassembly and disposal. 1.2 Target group: Authorised personnel All operations described in this operating instructions manual may only be performed by trained professional staff authorised by the operator. Only install and commission the SmartLINK if you have read and understood the operating instructions manual and are familiar with the applicable regulations. 1.3 Symbols and abbreviations used 1.4 Proper Use The products described here have been developed in order to ensure functions as part of an overall system. It is the responsibility of the installer to ensure the correct overall functioning. It may be used only in accordance with the following versions or for applications approved by the installer. Detailed information on the application range can be found in the chapter Product description. 1.5 General notes on safety The safety notes of the operating instructions manual and the countryspecific installation, safety and accident prevention regulations are to be followed. Residual risks are not known when observing the notes on safety and the instructions relating to the installation, commissioning, operation and maintenance. 1 i! Information, tip, note: This symbol highlights helpful additional information Caution: Failure to comply with this warning can lead to disorders & malfunctions. 1.6 Warning of misuse In case of inappropriate or improper use or tampering, malfunctions as well as risks, e.g. due to missing signal transmission, can arise for people due to the use of the SmartLINK cable transfer. Please follow the applicable standards / guidelines (DIN EN, VdS) in this respect. 2! Warning: Failure to comply with this warning can damage the SmartLINK. Power supply Supply channel Extension/additional modules Input Output White Yellow Brown Red Blue Green Switchon time PWR CHL EXT IN OUT WH YE BN RD BL GN ED 1.7 Disclaimer For damages or malfunctions caused by incorrect installation or failure to comply with this instruction manual, no liability is assumed. For damages resulting from the use of spare parts or accessories not approved by the manufacturer, any further liability of the manufacturer is excluded. Any unauthorised repairs, modifications and additions are not permitted for reasons of safety and exclude any liability of the manufacturer for damages resulting from this.

2 Product Description 2.1 Type code This operating instructions manual is valid for the following types: M 13 85 Guard/ lock plate for tube frame* M 13 86 Guard/ lock plate for wood* M 13 25 Lock plate / mounting box for tube frame* M 13 26 Lock plate / mounting box for wood* * hereinafter referred to in the operating instructions manual as SmartLINK Figure 2.3 Current [A] Current / Time CHL 2.2 Terms and conditions and use The SmartLINK is intended for installation in all standard timber, PVC and aluminium profile doors. It is used to secure the transmission of signals and voltages of the connected components. The SmartLINK enables domestic and commercial doors to be simply Duration [s] 3 and economically connected to power sources and signal sources, such as fingerprint, engine locks, etc. Due to the ease of installation and its construction, the domestic and commercial doors can be completely manufactured in the workshop, tested as an assembly and 4 accepted in the object immediately after installation. 2.3 Technical data Dimensions 8,5 20 Power supply 1 (PWR): 12 24 V DC, 3 A DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Power supply 2 (CHL): 0 48 V DC, 5 A DC (2 sec. ED, see Fig. 2.3), 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Inputs (IN 1 IN 4): galvanically isolated, max. 48 V DC / 5 ma DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Outputs (OUT 1 OUT 4): galvanically isolated, max. 48 V DC / 500 ma DC, 8 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Operating temperature range: 20 C to 70 C Line connection (KÜ): LiF9Y11Y 6 x 0.34 mm², halogenfree Housing: Plastic (ABS), protection type IP 42 Weight: 600 g. 22 3 4,5 300

3 Assembly M 13 85 Flügel Leaf Rahmen Frame 3.1 General notes on assembly Due to the plurality of profiles and fittings available on the market, no general information for mounting can be given since these systems differ in several dimensions. Please check the place of installation and the space available in the rabbet and profile area before the beginning of assembly. R4 R4 Place of assembly: Door rabbet Minimum installation depth M 13 85 / 86 : 28 mm Minimum installation depth M 13 25 / 26 : 50 mm The place of installation should be chosen in such a way that the coil is not crushed when the door is closed The SmartLINK must be installed in a Ushape (see Fig.) In addition to the generally valid state of the art, the following technical codes are to be particularly observed: DIN VDE 0100, VdS 2311 5 M 13 85 / M 13 86 6 max. 90mm M 13 85 Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep) Predrill for forend screw 2x Cables are run through the profile max. 90mm max. 180

M 13 86 A 20 Flügel Leaf Frame Rahmen B M 13 25 / M 13 26 3 3 28 28 max. 80mm 8 300 16 16 A B 8 max. 180 max. 80mm 7 8 M 13 86 Installation in wooden doors Processing of frame / leaf Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm M 13 25 Flügel Leaf R4 Rahmen Frame R4

M 13 25 Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep for lock plate, 50 mm deep for builtin box) Predrill for forend screw 2x Cables are run through the profile M 13 26 Installation in wooden doors Processing Frame: Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm Leaf: Mill recess for mounting box of 20 mm width and mm length, radius max. 6 mm (50 mm deep) Drill holes for cable exit Ø16 mm 9 M 13 26 10 Flügel Leaf A 20 R6 Frame Rahmen B 20 3.2 General notes on electrical connection The electrical connection may only be done in deenergised state and by authorised personnel. 20 50 3 28 For connection examples, see attachment 16 16 8 8 5 A B

4 Commissioning and Maintenance 5 Disassembly and Disposal 4.1 Commissioning and function test The SmartLINK is activated by turning on the supply voltage (PWR). The master begins a scanning process for connected slave stations (master: Status LED flashes green). Upon successful completion (master and slave 1: Status LED is green), the SmartLINK is ready for operation. If an error is detected in the scanning process (Master: Status LED flashes red) or the communication is faulty (Master: Status LED lights up red), all connections are to be checked and the scanning is to be repeated upon restarting. 5.1 Disassembly The SmartLINK is to be dismantled only in deenergised state. The dismantling of the screw plugin terminals must be done in accordance with Fig. 5.1 with a screwdriver.! Should a permanent disruption of communication occur during operation (master: Status LED is red), all outputs are turned off and the SmartLINK is to be restarted. Shortterm faults in the communication (master or slave 1: status LED flashes red) lead to a shutoff of all outputs for the duration of the fault. If there is no further disruption of communication (master and slave 1: status LED is green) the operation automatically resumes. Fig. 5.1 11 4.2 Maintenance When properly installed and used properly, the electronics do not require servicing. 5.2 Disposal The SmartLINK is to be disposed of professionally in accordance with the national regulations and laws. 12 We recommend a regular visual and functional test is undertaken with the following steps: Check SmartLINK for tightness Check lead, spring and housing for damage 6 Scope of Delivery It is recommended to clean exposed parts at least once per year with a soft, dry cloth. Never use oil or siliconecontaining lubricant or cleaning agent. Damaged or defective equipment are to be replaced. 1 pc. Cable transition SmartLINK M 13 x 1 pc. Installation manual SmartLINK M 13 x 1 accessories kit for electronics in the PEbag 2 pcs. Screw plugin terminal RM 3.50 pluggable, 8pole, no. 1 8 2 pcs. Screw plugin terminal RM 3.50 pluggable, 8pole no. 9 16 4 pcs. Screw plugin terminal RM 3.50 pluggable, 2pole 2 pcs. Cable ties 2.5 x 100 mm 1 accessories kit for attachment in the PEbag 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 50, A2 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 25, A2 4 pcs. Countersunk screw, Pozi DIN 965 PZ M4 x 8, A2, 70461M

7 Attachment Connection example: Input switching (valid for the inputs IN18) Connection example: Schematic diagramm Master: PWR IN 12V 24V Signal transmitter Input switching 1: Loop through the voltage PWR Voltage Voltage Slave 1: CHL IN 12V 48V Signal transmitter Input switching 2: Loop through the voltage CHL Control signals Control signals Control signals Control signals IN Optional 12V 48V Extern Input switching 3: Applying an external voltage Note: The correct polarity of the inputs must be ensured! The input switching can be freely selected for each input (IN 18). 13 14 Connection example: Power supply Connection example: Output switching (valid for outputs OUT18) Master: PWR CHL 1 2 12V 24V 12V 48V Master: PWR OUT 12V 24V Load Output switching 1: Loop through the voltage PWR Slave 1: PWR CHL 1 2 Optional Load Load Slave 1: CHL OUT Optional 12V 48V Load Output switching 2: Loop through the voltage CHL Optional Note: The correct polarity of the voltage PWR is to be ensured! The CHL connection is optional and can be freely assigned. OUT 12V 48V Extern Output switching 3: Loop through an external voltage Note: The correct polarity of the outputs is to be ensured! The output switching can be freely selected for each output (IN 18).

8 Declaration of Conformity 8.1. EC Declaration of Conformity 15 16

Specifications subject to change without notice. MA0002062 Stand: 4416 LINK GmbH D 35510 Butzbach Telephon: 49 (0) 6033974040 Fax: 49 (0) 60339740420 EMail: info@linkgmbh.com Internet: www.linkgmbh.com