Operation and Installation Manual SmartLINK M 13 x
Content 1 Document Content...1 1.1 Function...1 1.2 Target group: Authorised personnel...1 1.3 Symbols and abbreviations used...1 1.4 Proper use...2 1.5 General notes on safety...2 1.6 Warning of misuse...2 1.7 Disclaimer...2 2 Product Description...3 2.1 Type code...3 2.2 Terms and conditions and use...3 2.3 Technical data...3 3 Assembly...5 3.1 General notes on assembly...5 3.2 General notes on electrical connection...10 4 Commissioning and Maintenance...11 4.1 Commissioning and function test...11 4.2 Maintenance...11 5 Disassembly and Disposal...12 5.1 Disassembly...12 5.2 Disposal...12 6 Scope of Supply...12 7 Attachment...13 8 Declaration of Conformity...15 8.1 Declaration of ECconformity...15
1 Document Content 1.1 Function This operating instructions manual provides necessary information on installation, commissioning, safe operation, disassembly and disposal. 1.2 Target group: Authorised personnel All operations described in this operating instructions manual may only be performed by trained professional staff authorised by the operator. Only install and commission the SmartLINK if you have read and understood the operating instructions manual and are familiar with the applicable regulations. 1.3 Symbols and abbreviations used 1.4 Proper Use The products described here have been developed in order to ensure functions as part of an overall system. It is the responsibility of the installer to ensure the correct overall functioning. It may be used only in accordance with the following versions or for applications approved by the installer. Detailed information on the application range can be found in the chapter Product description. 1.5 General notes on safety The safety notes of the operating instructions manual and the countryspecific installation, safety and accident prevention regulations are to be followed. Residual risks are not known when observing the notes on safety and the instructions relating to the installation, commissioning, operation and maintenance. 1 i! Information, tip, note: This symbol highlights helpful additional information Caution: Failure to comply with this warning can lead to disorders & malfunctions. 1.6 Warning of misuse In case of inappropriate or improper use or tampering, malfunctions as well as risks, e.g. due to missing signal transmission, can arise for people due to the use of the SmartLINK cable transfer. Please follow the applicable standards / guidelines (DIN EN, VdS) in this respect. 2! Warning: Failure to comply with this warning can damage the SmartLINK. Power supply Supply channel Extension/additional modules Input Output White Yellow Brown Red Blue Green Switchon time PWR CHL EXT IN OUT WH YE BN RD BL GN ED 1.7 Disclaimer For damages or malfunctions caused by incorrect installation or failure to comply with this instruction manual, no liability is assumed. For damages resulting from the use of spare parts or accessories not approved by the manufacturer, any further liability of the manufacturer is excluded. Any unauthorised repairs, modifications and additions are not permitted for reasons of safety and exclude any liability of the manufacturer for damages resulting from this.
2 Product Description 2.1 Type code This operating instructions manual is valid for the following types: M 13 85 Guard/ lock plate for tube frame* M 13 86 Guard/ lock plate for wood* M 13 25 Lock plate / mounting box for tube frame* M 13 26 Lock plate / mounting box for wood* * hereinafter referred to in the operating instructions manual as SmartLINK Figure 2.3 Current [A] Current / Time CHL 2.2 Terms and conditions and use The SmartLINK is intended for installation in all standard timber, PVC and aluminium profile doors. It is used to secure the transmission of signals and voltages of the connected components. The SmartLINK enables domestic and commercial doors to be simply Duration [s] 3 and economically connected to power sources and signal sources, such as fingerprint, engine locks, etc. Due to the ease of installation and its construction, the domestic and commercial doors can be completely manufactured in the workshop, tested as an assembly and 4 accepted in the object immediately after installation. 2.3 Technical data Dimensions 8,5 20 Power supply 1 (PWR): 12 24 V DC, 3 A DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Power supply 2 (CHL): 0 48 V DC, 5 A DC (2 sec. ED, see Fig. 2.3), 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Inputs (IN 1 IN 4): galvanically isolated, max. 48 V DC / 5 ma DC, 2 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Outputs (OUT 1 OUT 4): galvanically isolated, max. 48 V DC / 500 ma DC, 8 pole screw plugin terminal, black, RM 3.5 mm, max. core crosssection: 1.0 mm² Operating temperature range: 20 C to 70 C Line connection (KÜ): LiF9Y11Y 6 x 0.34 mm², halogenfree Housing: Plastic (ABS), protection type IP 42 Weight: 600 g. 22 3 4,5 300
3 Assembly M 13 85 Flügel Leaf Rahmen Frame 3.1 General notes on assembly Due to the plurality of profiles and fittings available on the market, no general information for mounting can be given since these systems differ in several dimensions. Please check the place of installation and the space available in the rabbet and profile area before the beginning of assembly. R4 R4 Place of assembly: Door rabbet Minimum installation depth M 13 85 / 86 : 28 mm Minimum installation depth M 13 25 / 26 : 50 mm The place of installation should be chosen in such a way that the coil is not crushed when the door is closed The SmartLINK must be installed in a Ushape (see Fig.) In addition to the generally valid state of the art, the following technical codes are to be particularly observed: DIN VDE 0100, VdS 2311 5 M 13 85 / M 13 86 6 max. 90mm M 13 85 Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep) Predrill for forend screw 2x Cables are run through the profile max. 90mm max. 180
M 13 86 A 20 Flügel Leaf Frame Rahmen B M 13 25 / M 13 26 3 3 28 28 max. 80mm 8 300 16 16 A B 8 max. 180 max. 80mm 7 8 M 13 86 Installation in wooden doors Processing of frame / leaf Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm M 13 25 Flügel Leaf R4 Rahmen Frame R4
M 13 25 Installation in tubular frame doors Processing of frame / leaf Mill long slot width 20 mm and length mm, corner radius max. 4 mm (28 mm deep for lock plate, 50 mm deep for builtin box) Predrill for forend screw 2x Cables are run through the profile M 13 26 Installation in wooden doors Processing Frame: Mill recess for lock plates radius 10 mm (3 mm deep) Mill recess of mm width and mm length (28 mm deep) Drill holes for cable exit Ø16 mm Leaf: Mill recess for mounting box of 20 mm width and mm length, radius max. 6 mm (50 mm deep) Drill holes for cable exit Ø16 mm 9 M 13 26 10 Flügel Leaf A 20 R6 Frame Rahmen B 20 3.2 General notes on electrical connection The electrical connection may only be done in deenergised state and by authorised personnel. 20 50 3 28 For connection examples, see attachment 16 16 8 8 5 A B
4 Commissioning and Maintenance 5 Disassembly and Disposal 4.1 Commissioning and function test The SmartLINK is activated by turning on the supply voltage (PWR). The master begins a scanning process for connected slave stations (master: Status LED flashes green). Upon successful completion (master and slave 1: Status LED is green), the SmartLINK is ready for operation. If an error is detected in the scanning process (Master: Status LED flashes red) or the communication is faulty (Master: Status LED lights up red), all connections are to be checked and the scanning is to be repeated upon restarting. 5.1 Disassembly The SmartLINK is to be dismantled only in deenergised state. The dismantling of the screw plugin terminals must be done in accordance with Fig. 5.1 with a screwdriver.! Should a permanent disruption of communication occur during operation (master: Status LED is red), all outputs are turned off and the SmartLINK is to be restarted. Shortterm faults in the communication (master or slave 1: status LED flashes red) lead to a shutoff of all outputs for the duration of the fault. If there is no further disruption of communication (master and slave 1: status LED is green) the operation automatically resumes. Fig. 5.1 11 4.2 Maintenance When properly installed and used properly, the electronics do not require servicing. 5.2 Disposal The SmartLINK is to be disposed of professionally in accordance with the national regulations and laws. 12 We recommend a regular visual and functional test is undertaken with the following steps: Check SmartLINK for tightness Check lead, spring and housing for damage 6 Scope of Delivery It is recommended to clean exposed parts at least once per year with a soft, dry cloth. Never use oil or siliconecontaining lubricant or cleaning agent. Damaged or defective equipment are to be replaced. 1 pc. Cable transition SmartLINK M 13 x 1 pc. Installation manual SmartLINK M 13 x 1 accessories kit for electronics in the PEbag 2 pcs. Screw plugin terminal RM 3.50 pluggable, 8pole, no. 1 8 2 pcs. Screw plugin terminal RM 3.50 pluggable, 8pole no. 9 16 4 pcs. Screw plugin terminal RM 3.50 pluggable, 2pole 2 pcs. Cable ties 2.5 x 100 mm 1 accessories kit for attachment in the PEbag 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 50, A2 4 pcs. Tapping screw countersunk, Pozi DIN 7982 PZ C 3.5 x 25, A2 4 pcs. Countersunk screw, Pozi DIN 965 PZ M4 x 8, A2, 70461M
7 Attachment Connection example: Input switching (valid for the inputs IN18) Connection example: Schematic diagramm Master: PWR IN 12V 24V Signal transmitter Input switching 1: Loop through the voltage PWR Voltage Voltage Slave 1: CHL IN 12V 48V Signal transmitter Input switching 2: Loop through the voltage CHL Control signals Control signals Control signals Control signals IN Optional 12V 48V Extern Input switching 3: Applying an external voltage Note: The correct polarity of the inputs must be ensured! The input switching can be freely selected for each input (IN 18). 13 14 Connection example: Power supply Connection example: Output switching (valid for outputs OUT18) Master: PWR CHL 1 2 12V 24V 12V 48V Master: PWR OUT 12V 24V Load Output switching 1: Loop through the voltage PWR Slave 1: PWR CHL 1 2 Optional Load Load Slave 1: CHL OUT Optional 12V 48V Load Output switching 2: Loop through the voltage CHL Optional Note: The correct polarity of the voltage PWR is to be ensured! The CHL connection is optional and can be freely assigned. OUT 12V 48V Extern Output switching 3: Loop through an external voltage Note: The correct polarity of the outputs is to be ensured! The output switching can be freely selected for each output (IN 18).
8 Declaration of Conformity 8.1. EC Declaration of Conformity 15 16