KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Similar documents
INTERFACE SPECIFICATION

Installation Manual. DZK BACnet

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

RTD-NET Installation Instructions

MODEL: R2K-1 SEN TRONIC AG. R2K Series

IntesisBox PA-AC-MBS-1

ERV Control Interface Installation / Operation manual. TCB-IFVN1UL ERV Control Interface ENGLISH

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IntesisBox PA-AW-MBS-1 v.2.0

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

INSTALLATION MANUAL For authorized service personnel only.

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

ThermoPad Reference Manual

OPERATION INSTRUCTIONS

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Communicative controller for VAV systems

Non-communicating room controllers

DEB 1.2k/2.5k. Electronic Flicker Free Ballast MOD INSTRUCTION AND MAINTENANCE MANUAL

EY-RU : Room operating unit, ecounit

RS485/ KNX Bidirectional Converter K-BUS R. User manual-ver.1.3 BTPT-02/ KNX/EIB Intelligent Installation System

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

Non-communicating room controllers

Industrial 3-Port Fast Ethernet Media Converter Switches

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

Appendix G. CJ1W-CIF11 RS-422A Converter

EY-RU 355: Room operating unit, ecounit355

Prisma II Platform. Optoelectronics

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL

GRASSO SYSTEM CONTROL

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

FL MC 2000E (SM40) LC

IntesisBox ModBus RTU Fujitsu Air Conditioning

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Temperature controller Ducted systems

T2314, T2414. Instruction Manual

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

ST-PTZ High-Speed Intelligent Dome PTZ Color Camera

DESIGN & TECHNICAL MANUAL

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Modbus Server - Mitsubishi Electric G50

VBAR 270. User Manual. Version 1.2

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014

INSTALLATION MANUAL Wired Remote Control

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Installation and User Guide

Products no longer available

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

T2314, T2414. Instruction Manual

INSTALLATION MANUAL SLI 50 INVERTER

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

PROFIBUS DP/CAN Gateway PCA-100. User Manual

IntesisBox TO-RC-MBS-1

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

KFC-200. Installation Guide

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

3500/22M Transient Data Interface

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Description. SmartControl with PoE: SSC-P008. Feature Summary. Rear View of SSC-P008

OWNER S MANUAL WIRE CONTROLLER OF AIR CONDITIONER. MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000

Vector Beam White. User Manual. Order code: LEDJ265

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

REMOTE CONTROLLER CS244-R OWNER S MANUAL

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Modbus RTU (EIA-485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models.

Cisco Prisma II Platform

Supplementary operating instructions for your air curtain system Controller TMC 500

ISOMETER isoev425 with coupling device AGH420

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

User's Guide. Model W 3-in-1 Switching DC Power Supply

HuddleCamHD RS-232 Joystick Controller Model Number: HC-JOY

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Service Section. December 2003

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

RTD-W Installation Instructions

IntesisBox Modbus Server Hitachi VRF Air Conditioning. User Manual Issu Date: 11/2018 r1.0 EN

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

RMx621. Appendix to the operating manual

Room Controllers. SC3000 Relay Pack

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Modbus Interface Module

Transcription:

PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable products, model code and date of sales: New product: Model Description Model Code Sales Date HC-A16KNX 7E513300 June 2010 2. Features KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS). This new accessory allows the full integration between Hitachi Air Conditioning installation and a KNX system. (1) KNX Direct Adapter HC-A16KNX is a gateway that allows connection between KNX BMS communication network and Hitachi proprietary H-Link line. HC-A16KNX is configured directly from KNX ETS software like most devices in KNX network which is supplied and managed by KNX company. (2) H-LINK 2 Compatible HC-A16KNX adds compatibility with the new version of H-LINK communication called H-LINK 2 while maintaining full compatibility with current H-LINK (H-LINK 1) units. Up to 16 HC-A16KNX can be connected in an H-LINK line. One and only one of this HC-A16KNX must be set as master.

PRODUCT NEWS Products News: New HC-A16KNX PAGE 2 / 8 FIRE & SAFETY ALARM... LIGHTING BLINDS & DOORS HEATING... HLINK KNX HARC-KNX INTERNET HC-A16KNX can be connected in an H-LINK 1 and/or H-LINK 2 communication line. 3. New Product General Data 3.1. Component Names 3 1 [1] K1: H-LINK Connector. [2] KNX Port [3] K3: +5V DC Power Connection [4] Power Source + - [5] H-LINK PCB [6] KNX PCB [7] Packing glands (2) 7 6 2 8 5 4 [8] 7-Segments

PRODUCT NEWS Products News: New HC-A16KNX PAGE 3 / 8 3.2. Specifications Hardware Specifications Item Power supply Consumption Outer dimensions Specifications 1~230 V ±10% 50Hz 25 W (maximum) Width: 143 mm, Depth: 302 mm, Height: 76 mm Weight 1.75 kg Indoors (in a control panel or desktop) Assembling conditions Ambient temperature 0~40 C Humidity 20~85% (Without condensation) H-LINK Item Communication with Communication line Communications system Communication method Speed of transmission Length of wiring Maximum number of HC-A16KNX Specifications HITACHI PACKAGED Twisted pair shielded cable, non polarity Half-duplex Asynchronous 9600 Bauds 1000 m maximum (total length of HLINK I/O bus) 8 HC-A16KNX/H-LINK SYSTEM (PACKAGED) 3.3. Dimensional Data (1) Dimensions (2) Area needed for ventilation and cable

PRODUCT NEWS Products News: New HC-A16KNX PAGE 4 / 8 3.4. DIP Switch Settings Name Function Factory setting Description SW1 KNX PCB Reset KNX PCB - Reset button. To be used in case of KNX communication has been locked. SW1 t available All in off (no function) H-LINK PCB SW2 Reset - Reset button. To be used in case of program has been locked SW3 (TELE) t available Factory purposes. Never change it SW4 Configuration - Setting functions SW5 Configuration - Setting functions SW6 Configuration - Setting functions SW7 Options 2 Configuration as MASTER HC-A16KNX: SW7-1=ON. Only one HC-A16KNX can be set as a MASTER HC-A16KNX. Setting by default. Configuration as SLAVE HC-A16KNX: SW7-1= OFF. It should be 1 HC-A16KNX configured as MASTER, all the rest of HC- A16KNX must be configured as SLAVE. SW8 Options 1 All in off (no function) (Application type) SW9 t available All in off (no function) SW10 HC-A16KNX HC-A16KNX address from 0 to 31 by pins 1 to 5 address SW11 H-LINK DSW SW11-1: H-LINK end resistance SW11-2: t used D4, D11 H-LINK - H-LINK transmission D5 t used - - D6 Units configuration alarm - ON- alarms OFF- Units not configured D7 Power - Power supply ON/OFF D9/D10 t used - - D12 KNX - Internal communication between the KNX PCB and the H-LINK PCB. D13 Operation - rmal software operation

PRODUCT NEWS Products News: New HC-A16KNX PAGE 5 / 8 3.5. Configuration method Every HC-A16KNX can control up to 16 I.U, considering that in the same H-LINK can be connected up to 160 IU, it must be set which indoor units are selected for each HC-A16KNX. Setting concept consist in an id table listing up to 16 numbers for the assignation of each OU+IU addresses as shows the following example. Id Rerigerant cycle address Indoor unit address NOTE: It can be selected for 1 HC-A16KNX up to 16 I.U from 16 different refrigerant cycles or 16 I.U from the same refrigerant cycle. Those I.U. must be assigned to a BMS id from 0 to 15, from 16 to 31 must be without any configuration. CAUTION: Be sure not to set same Indoor Unit to more than one HC-A16KNX. This error is undetectable and can cause undesired operations. Addresses over id 15 are not used because they cannot be controlled with HC-A16KNX. Using them could create some problems with the configured units between 0 and 15.

PRODUCT NEWS Products News: New HC-A16KNX PAGE 6 / 8 Step number Example: Action 7 segments (display) Remarks 1 Press SW4 for 3 seconds Configuration mode selected 2 Press SW4 Id selection (IU.) from 0 to 15 by pushing SW5 or SW6 3 Press SW4 Refrigerant cycle address 4 Press SW4 Refrigerant cycle address selection from 0 to 15 (e.g. 00) 5 Press SW4 Indoor unit address 6 Press SW4 Indoor unit address selection from 0 to 15 (e.g. 00) For id 01 repeat steps 1 to 6 7 Press SW4 for 3 seconds Configuration mode selected 8 Press SW4 Id selection (IU.) from 0 to 15 by pushing SW5 or SW6 9 Press SW4 Refrigerant cycle address 10 Press SW4 Refrigerant cycle address selection from 0 to 15 (e.g. 00) 11 Press SW4 Indoor unit address 12 Press SW4 Indoor unit address selection from 0 to 15 (e.g. 01; push SW5 once)... Repeat steps 1 to 6 for all the rest Id 91 Press SW4 for 3 seconds Configuration mode selected 92 Press SW4 Id selection (IU.) from 0 to 15 by pushing SW5 or SW6 93 Press SW4 Refrigerant cycle address 94 Press SW4 Refrigerant cycle address selection from 0 to 15 (e.g. 01; push SW5 once)) 95 Press SW4 Indoor unit address 96 Press SW4 Indoor unit address selection from 0 to 15 (e.g. 15; push SW6 once) 97 Press SW4 for 3 seconds thing displayed Exit from configuration mode

PRODUCT NEWS Products News: New HC-A16KNX PAGE 7 / 8 3.6. Available Data KNX Default address for this device is 1.1.1, it can later be modify using ETS software from KNX Association. The maximum numbers of units that can be controlled using HC-A16KNX are 16. Each unit has 15 communication objects. These objects are explained as follows: Address Name Length Description Values 0 Unit-N On/Off 1 bit ON / OFF order. 0-On 1-Off 1 Unit-N Mode 1 byte Mode setting order. 0=Auto 1=Heat 2=Dry 3=Fan 4=Cool 2 Unit-N Fan 1 byte Fan setting order. 0~30%= Low 31~60%= Medium 61~100%= High 3 Unit-N Louver Scale 1 byte Louver position setting. 0~15%= Pos0 16~30%= Pos1 31~45%=Pos2 46~60%= Pos3 61~75%=Pos4 76~90%= Pos5 91~100%= Pos6 4 Unit-N Louver Auto 1 bit Automatic Louver Setting. 1=Louver Automatic active 5 Unit-N Set Temperature 2 bytes Setting temperature. 17~30ºC 6 Unit-N Ambient 2 bytes Inlet Air Ambient 17~30ºC Temperature Temperature. 7 Unit-N Alarm 1 bit Alarm notification. 1= alarm on unit N 8 Unit-N Alarm Code 1 byte Alarm code. See errors table from HC- A16KNX 9 Unit-N Mode Cool 1 bit Cool mode order. 1=Mode Cool Active 10 Unit-N Mode Dry 1 bit Dry mode order. 1=Mode Dry Active 11 Unit-N Mode Fan 1 bit Fan mode order. 1=Mode Fan Active 12 Unit-N Mode Heat 1 bit Heat mode order. 1=Mode Heat Active 13 Unit-N Mode Auto 1 bit Auto mode order. 1=Mode Auto Active 14 Unit-N Prohibit 1 bit On Yes works only with KNX orders, on, the unit could receive local orders and from KNX too. 0= 1=Yes te: - Offset position is N*Address as shown in table, where N is the Indoor Unit position in the address table (1~16). - Address from 9 to 13 will work together. They are used to set the function mode. Only one of them could be activated at the same time. When one of these bits will be set as 1, the rest will be changed at 0.

PRODUCT NEWS Products News: New HC-A16KNX PAGE 8 / 8 Global objects: Address Name Length Description Values 1~16 Unit-1~16 1 bit per unit Shows if HC-A16KNX used the communication with the H-LINK PCB for unit N where N is the address to read. 240 Communication Alarm Error code list: Code (in Description Hexadecimal) 0 Error 1~98 See Hitachi documentation 99 Unit not configured 1 bit With value is 1 means that is not possible to communicate with the H-LINK PCB. On 0, communication is working properly. 1=Communication works 1=Communication Alarm.