Replacing a PCIe card

Similar documents
Replacing a PCIe card

Replacing the NVDIMM battery

1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:

This diagram shows the workflow of the DIMM replacement procedure for a FAS2600 system.

Replacing the controller module

Replacing the boot media

Replacing drives for SolidFire storage nodes

Replacing the chassis

All other components in the system must be functioning properly; if not, you must contact technical support.

Replacing the chassis

All other components in the system must be functioning properly; if not, you must contact technical support.

Replacing the chassis

Replacing the boot media

Cluster and SVM Peering Express Guide

NetApp SolidFire Element OS. Setup Guide. Version March _A0

Cluster Switch Setup Guide for Cisco Switches. May _A0_UR006

Replacing a Power Canister in E5760 or E2860 Shelves

Upgrade Express Guide

Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays

StorageGRID Webscale NAS Bridge Management API Guide

Volume Disaster Recovery Preparation Express Guide

Replacing a Power-Fan Canister in E5700 or E2800 Shelves

Volume Move Express Guide

iscsi Configuration for ESXi using VSC Express Guide

FlexArray Virtualization

FlexArray Virtualization

FlexArray Virtualization

E-Series Converting the Protocol of E2800 Host Ports (New Systems)

Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray

FlexArray Virtualization Implementation Guide for NetApp E-Series Storage

E-Series Cabling E-Series Hardware

Replacing a drive in E5724 shelves

Clustered Data ONTAP 8.3

AltaVault Cloud Integrated Storage Installation and Service Guide for Virtual Appliances

OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View

NFS Client Configuration with VAAI for ESX Express Guide

Replacing the controller module

Replacing a Drive Drawer in a 60-Drive Tray

Performance Characterization of ONTAP Cloud in Azure with Application Workloads

Inventory Collect Tool 1.4

SNMP Configuration Express Guide

Navigating VSC 6.1 for VMware vsphere

NetApp HCI Network Setup Guide

Volume Disaster Recovery Express Guide

OnCommand Unified Manager 7.2: Best Practices Guide

Nondisruptive Operations with SMB File Shares

Upgrading E5400 or EF540 Controllers to E5600 or EF560 Controllers when Using Fibre Channel and iscsi

Performance Characterization of ONTAP Cloud in Amazon Web Services with Application Workloads

AltaVault Cloud Integrated Storage Installation and Service Guide for Cloud Appliances

Migrating Performance Data to NetApp OnCommand Unified Manager 7.2

Clustered Data ONTAP 8.3

HCI File Services Powered by ONTAP Select

Replication between SolidFire Element OS and ONTAP

SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter

Replacing the controller module

Replacing a Battery in E2800 or E5700 Shelves

NetApp AltaVault Cloud-Integrated Storage Appliances

NetApp HCI QoS and Mixed Workloads

NetApp AltaVault Cloud-Integrated Storage Appliances

SAS Disk Shelves. Service Guide. For DS460C, DS224C and DS212C. November _C0

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Replacing an NVMEM battery in a FAS22xx system

OnCommand Cloud Manager 3.0 Administration Guide

MongoDB Database on NetApp AFF8080

NetApp AltaVault Cloud-Integrated Storage Appliances

SMB/CIFS Configuration Express Guide

Replacing an E5700 or E2800 Controller (Duplex Configuration)

NetApp Cloud Volumes Service for AWS

Nokia Intellisync Mobile Suite Client Guide. S60 Platform, 3rd Edition

Disaster Recovery for Enterprise Applications with ONTAP Cloud

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Big-Data Pipeline on ONTAP and Orchestration with Robin Cloud Platform

SQL Server on NetApp HCI

Clustered Data ONTAP 8.3

NetApp Data ONTAP Edge on SoftLayer

Inventory Collect Tool 2.2

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Cluster Switch Setup Guide for Cisco Switches. October _A0_ur005

NFS Client Configuration for ESX Express Guide

OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager

Intellisync Mobile Suite Client Guide. S60 3rd Edition Platform

Wiwynn SV Maintenance User Manual

iscsi Configuration for Windows Express Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Tower to Rack and Rack to Tower System Conversion Guide

NetApp System Manager 1.1 Quick Start Guide

All other components in the system must be functioning properly; if not, you must contact technical support.

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

Nokia Intrusion Prevention with Sourcefire. Appliance Quick Setup Guide

NetApp AFF A300 Gen 6 Fibre Channel

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage

iscsi Configuration for ESX Express Guide

Nokia Client Release Notes. Version 2.0

Wiwynn SV320 Maintenance User Manual

Installing and Configuring for AIX

Chassis (FRU) Replacement Guide

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

AirPort Extreme Card

Transcription:

AFF A700s systems Replacing a PCIe card To replace a PCIe card, you must disconnect the cables from the cards in the riser, remove the riser, replace the riser, and then recable the cards in that riser. About this task You can use this procedure with all versions of ONTAP supported by your system All other components in the system must be functioning properly; if not, you must contact technical support.. Shutting down the impaired controller on page. Removing the controller module on page. Replacing a PCIe card on page 4. Reinstalling the controller module on page 5 5. Completing the replacement process on page 6 Shutting down the impaired controller You can shut down or take over the impaired controller using different procedures, depending on the storage system hardware configuration. Shutting down the impaired node To shut down the impaired node, you must determine the status of the node and, if necessary, take over the node so that the healthy node continues to serve data from the impaired node storage.. If you have a cluster with more than two nodes, check the health and Epsilon from advanced mode: cluster show -epsilon * If the cluster is not in quorum or a node that is not the impaired node shows false for eligibility and health, correct the issue before proceeding to the next step. If Epsilon resides in the impaired node: a. Remove Epsilon from the impaired node: cluster modify -node impaired_node -epsilon false b. Assign Epsilon to a healthy node in the cluster: cluster modify -node healthy_node -epsilon true. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node: storage failover modify -node local -auto-giveback false. Take the impaired node to the LOADER prompt: 5-07_C0 November 07 Copyright 07 NetApp, Inc. All rights reserved. Web: www.netapp.com Feedback: doccomments@netapp.com

If the impaired node is displaying... The LOADER prompt Then... Go to the next step. Waiting for giveback... Press Ctrl-C, and then respond y. System prompt or password prompt Take over or halt the impaired node: storage failover takeover -ofnode impaired_node_name When the impaired node shows Waiting for giveback..., press Ctrl-C, and then respond y. Removing the controller module You must remove the controller module from the chassis when you replace the controller module or replace a component inside the controller module.. If you are not already grounded, properly ground yourself.. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug the system cables and SFPs (if needed) from the controller module, keeping track of where the cables were connected. Leave the cables in the cable management device so that when you reinstall the cable management device, the cables are organized.. Unplug the controller module power supply from the source, and then unplug the cable from the power supply. 4. Remove the cable management device from the controller module and set it aside. 5. Press down on both of the locking latches, and then rotate both latches downward at the same time. The controller moves slightly out of the chassis. AFF A700s systems: Replacing a PCIe card

Locking latch Locking pin 6. Slide the controller module out of the chassis. Make sure that you support the bottom of the controller module as you slide it out of the chassis. 7. Place the controller module on a stable, flat surface, and then open the air duct: a. Press in the locking tabs on the sides of the air duct toward the middle of the controller module. b. Slide the air duct toward the fan modules, and then rotate it upward to its completely open position. Air duct locking tabs Risers Air duct Replacing a PCIe card To replace a PCIe card, you must remove the cabling and any SFPs from the ports on the PCIe cards in the target riser, remove the riser from the controller module, remove and replace the PCIe card, reinstall the riser, and recable it.. If you are not already grounded, properly ground yourself. Replacing a PCIe card

. Remove the PCIe riser from the controller module: a. Remove any SFP modules that might be in the PCIe cards. b. Rotate the module locking latch on the left side of the riser up and toward the fan modules. The PCIe riser raises up slightly from the controller module. c. Lift the PCIe riser up, shift it toward the fans so that the sheet metal lip on the riser clears the edge of the controller module, lift the riser out of the controller module, and then place it on a stable, flat surface. 4 4 Air duct Riser locking latch Card locking bracket Riser (middle riser) and PCI cards in riser slots and.. Remove the PCIe card from the riser: a. Turn the riser so that you can access the PCIe card. b. Press the locking bracket on the side of the PCIe riser, and then rotate it to the open position. c. Remove the PCIe card from the riser. 4. Install the PCIe card into the same slot in PCIe riser: a. Align the card with the card guide on the riser and the card socket in the riser, and then slide it squarely into the socket in the riser. 4 AFF A700s systems: Replacing a PCIe card

Note: Make sure that the card is completely and squarely seated into the riser socket. b. Swing the locking latch into place until it clicks into the locked position. 5. Install the riser into the controller module: a. Align the lip of the riser with the underside of the controller module sheet metal. b. Guide the riser along the pins in the controller module, and then lower the riser into the controller module. c. Swing the locking latch down and click it into the locked position. When locked, the locking latch is flush with the top of the riser and the riser sits squarely in the controller module. Reinstalling the controller module After you replace a component within the controller module, you must reinstall the controller module in the system chassis and boot it.. If you are not already grounded, properly ground yourself.. If you have not already done so, close the air duct: a. Swing the air duct all the way down to the controller module. b. Slide the air duct toward the risers until the locking tabs click into place. c. Inspect the air duct to make sure that it is properly seated and locked into place. Locking tabs Reinstalling the controller module 5

Slide plunger. Align the end of the controller module with the opening in the chassis, and then gently push the controller module halfway into the system. Note: Do not completely insert the controller module in the chassis until instructed to do so. 4. Recable the system, as needed. If you removed the media converters (SFPs), remember to reinstall them if you are using fiber optic cables. 5. Plug the power cord into the power supply, reinstall the power cable locking collar, and then connect the power supply to the power source. 6. Complete the reinstallation of the controller module: a. If you have not already done so, reinstall the cable management device. b. Firmly push the controller module into the chassis until it meets the midplane and is fully seated. The locking latches rise when the controller module is fully seated. Attention: Do not use excessive force when sliding the controller module into the chassis; you might damage the connectors. The controller module begins to boot as soon as it is fully seated in the chassis. c. Rotate the locking latches upward, tilting them so that they clear the locking pins, and then lower them into the locked position. 7. If your system is configured to support 0GbE cluster interconnect and data connections on 40GbE NICs or onboard ports, you must convert these ports to 0GbE connections with the nicadmin convert command from Maintenance mode. Note: Be sure to exit Maintenance mode after completing the conversion. 8. Return the node to normal operation by giving back its storage: storage failover giveback -ofnode impaired_node_name 9. If automatic giveback was disabled, reenable it: storage failover modify -node local -auto-giveback true Completing the replacement process After you replace the part, you can return the failed part to NetApp, as described in the RMA instructions shipped with the kit. Contact technical support at NetApp Support, 888-46-877 (North America), 00-800-44-6877 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the replacement procedure. Copyright information Copyright 08 NetApp, Inc. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: 6 AFF A700s systems: Replacing a PCIe card

THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)()(ii) of the Rights in Technical Data and Computer Software clause at DFARS 5.77-70 (October 988) and FAR 5-7-9 (June 987). Trademark information NETAPP, the NETAPP logo, and the marks listed on the NetApp Trademarks page are trademarks of NetApp, Inc. Other company and product names may be trademarks of their respective owners. http://www.netapp.com/us/legal/netapptmlist.aspx How to send comments about documentation and receive update notifications You can help us to improve the quality of our documentation by sending us your feedback. You can receive automatic notification when production-level (GA/FCS) documentation is initially released or important changes are made to existing production-level documents. If you have suggestions for improving this document, send us your comments by email. doccomments@netapp.com To help us direct your comments to the correct division, include in the subject line the product name, version, and operating system. If you want to be notified automatically when production-level documentation is released or important changes are made to existing production-level documents, follow Twitter account @NetAppDoc. You can also contact us in the following ways: NetApp, Inc., 495 East Java Drive, Sunnyvale, CA 94089 U.S. Telephone: + (408) 8-6000 Fax: + (408) 8-450 Support telephone: + (888) 46-877 Trademark information 7