Digital Sound Level Meter

Similar documents
Instruction Manual Digital Sound Level Meter

Integrating Sound Level Datalogger Model

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Sound Level Meter SD Card real-time Datalogger

User's Manual. Digital Sound Level Meter. Model

User's Guide. Digital Sound Level Meter. Model

DIGITAL SOUND METER WITH JUMBO DISPLAY

DIGITAL SOUND 8922 Owner s manual Sound level meter

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

Digital Sound Level Meter MODEL

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Digital Sound Level Meter

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Pro II. Sound Level Meter V-9992

1. GENERAL DESCRIPTION & SPECIFICATIONS

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

SOUND LEVEL METER INSTRUCTION MANUAL

TES-1358 INSTRUCTION MANUAL

DIGITAL SOUND LEVEL METER. Instruction Manual

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Digital Sound Level Meter with USB Model:

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Manual SOUND LEVEL METER PCE-322 A

Manual Sound level indicator PCE-353

Digital Sound Level Meter

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

INSTRUCTION MANUAL REC FAST A/C

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

Personal Sound Level Meter

User's Manual Sound Level Alert Model SL130

ATE-9051 User s Manual

Digital Sound Level Meter

Pocket type SOUND LEVEL METER Model : SL-4030

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Sound Level Pen Instruction Manual

USER GUIDE. Noise Dosimeter with PC Interface. Model

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

USER GUIDE. Model Noise Dosimeter with PC Interface

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

USER S MANUAL. Data Logger SOUND LEVEL METER.

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

HOLDPEAK Sound Level Meter Instruction Manual

Digital Sound Level Meter. Operation Manual

Heavy Duty Vibration Meter

DSM403SD USER S MANUAL

CLASS 2 SOUND LEVEL METER WITH EXCEL-FORMATTED DATA LOGGING SD CARD USER S MANUAL

Vibration Meter SD Card real-time datalogger

Heavy Duty Datalogger Module

Instruction Manual Digital Sound Level Meter

4-Channel Thermometer / Datalogger

TES-1353S INSTRUCTION MANUAL

Visit us at Back to the Extech Product Page

Heavy Duty Datalogger Module

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. Datalogging Sound Level Meter. Instruction Manual.

12-Channel Thermocouple Datalogger

ph/orp Meter SD Card real-time Datalogger

4-Channel Vibration Datalogger

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

Hygro-Thermometer / Datalogger

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Light intensity measuring instrument

Manual Sound level meter PCE-353

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Heavy Duty Vibration Meter

DIGITAL SOUND LEVEL METER

testo Sound Level Meter Instruction Manual

Digital Vane Thermo-Anemometer Model

INSTRUCTION MANUAL. Models: H100 Light Meter

Advanced Datalogging Sound Meter Instruction Manual

Light Meter SD Card real-time datalogger

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Light Meter with Bar Graph

Advanced Datalogging Thermometer. Instruction Manual

True RMS AC Voltage/Current Datalogger

Integrating Sound Level Meters LA-5570/5560/2560

User's Guide. Vibration Meter and Laser Combination Tachometer Model

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

Torque Meter. Instruction Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

SOUND LEVEL DATALOGGER. Instruction Manual - 1 -

Noise Dosimeter, Datalogger, and Sound Level Meter With PC Interface

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

4-Channel Thermometer

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

I. PANEL DESCRIPTION... 1

APPENDIX. Larson Davis CAL200. Technical Reference Manual. I200.1 Rev F

Transcription:

Digital Sound Level Meter Model: 8921 8922

INTRODUCTION Your digital sound level meter provides automatic or manual ranging in six meas-urement ranges from 30 to 130dB. The unit meets ANSI S1.4 and IEC 651 Type 2 standards, and features 0.1dB resolution. A background noise absorber permits you to measure sound levels accurately even in the presence of high background noise. The meter allows you to select between fast and slow response times and A and C weighting. A maximum hold function is provided. Jacks on the meter provide both AC and DC analog output, while an RS-232 interface allows you to use an optional cable to capture sound level data on a PC. FUNCTIONS: 1. Selecting A & C weighting. 2. Selecting the response time. 3. Freezing the maximum sound level reading. 4. Recording the maximum and minimum measurements. 5. Using the backgound noise absorber. 6. Selecting Automatic and manual ranging. 7. Automatic shut off. 8. Easy to replace battery.

FRONT PANEL DESCRIPTION 1 MICROPHONE 2 LCD DIAY 3 ON/OFF - Power button 4 REC - Records sound level readings 5 MAXHLD - Freezes the maximum sound level digital reading 6 C/A - A/C frequency weighting selector 7 BA MODE- Background noise absorber 8 F/S - Fast/Slow response selector 9 DOWN - Adjusts the measurement range 10 UPPER 11 DC 9V 12 CAL 13 AC OUT 14 DC OUT 15 RS232 16 BACKLIT - Adjusts the measurement range - DC adapter jack - Calibration screw - AC analog output jack - DC analog output jack - RS-232 output jack - Back light (Model 8922 only) The meter will display all segments when it is first turned on. Though you might seen SEL, Leq, DOSE, PEAK... These are not available for the meter you purchased, please contact the store or the place you purchased for further models with these additional functions.

FRONT PANEL DIAGRAM 0 16

MEASURING SOUND LEVELS Sound levels are displayed both digitally and in a bar graph. The digital display is updated every 160ms, while the bar graph is updated every 40ms. Press the ON/OFF key to turn the meter on. The unit will first display the full screen and then count down to zero.(see Fig. 1) 90dB 50dB 90 +20 +30 +40 +50 Fig.1 The meter will now begin measuring the current sound levels.(see Fig.2) 50 +20 +30 +40 +50 Fig.2 Point the microphone toward the source of the sound to be measured.

SELECTING A AND C WEIGHTING When you turn the meter on, it will be in A weighting mode. A weighting enables the meter to respond in the same manner as the human ear, which increases and decreases amplitude over the frequency spectrum. Applications for A weighting include OSHA regulatory testing, environmental measurement, workplace design, and law enforcement. C weighting is suitable for flat response measurements with no increase or decrease of amplitude over the frequency spectrum. Applications for C weighting include the sound level analysis of engines and machinery. Press the C/A key to toggle between A and C weighting. A small A or C will be displayed on the right side of the screen to indicate the current mode. Fig.3 40

SELECTING THE RESPONSE TIME You can select fast or slow response time to suit different applications and standards. For example, most OSHA-related testing is done using slow response time and A weighting. When you turn the meter on, it will be in FAST response mode. Press the F/S key to toggle between FAST and SLOW response. A small SLOW will be displayed on the right side of the screen to indicate the current mode.(see Fig.4) 40 Fig.4 FREEZING THE MAXIMUM SOUND LEVEL READING 1 Press the ON/OFF key to turn the meter on. 2 When measuring sound levels, press the MAXHLD key to freeze the maximum reading. MAX HOLD will be displayed. (See Fig.5) The digital display will remain unchanged until a higher reading is detected. Note that the bar graph will continue to record the current reading. 3 Press the MAXHLD key again to exit maximum hold mode.

60 Fig.5 FAST A RECORDING THE MAXIMUM AND MINIMUM MEASUREMENTS 1 Press the ON/OFF key to turn the meter on. 2 Press the REC key. REC will be displayed on the bottom of the screen(see Fig.6). The meter will begin tracking the maximum and minimum sound level measurements. Fig.6 40 3 Press the REC key again. MIN will appear on the bottom of the screen (See Fig.7) and the mini. sound level measurement will be displayed. The unit isn't recording at this time, but the bar graph will continue to show the current reading. Fig.7 40

4 Press the REC key again. MAX will appear on the bottom of the screen and the maximum sound level measurement will be displayed. The unit is not recording at this time,but the bar graph will continue to show the current reading. 40 Fig.8 5 Press the REC key again to resume recording and repeat the process. 6 Press and hold the REC key until the REC indicator disappears to exit recording mode. USING THE BACKGROUND NOISE ABSORBER This feature allows you to measure equipment noise accurately, even in the presence of high background noise. 1 Press the ON/OFF key to turn the meter on. 2 Press the MAXHLD key. MAX HOLD will be displayed.(see Fig.5)

3 Press the BA MODE key. F will be displayed to the left of the (sound pressure level) icon. The digital display will show the background noise level.max HOLD will be disappeared now. (See Fig.9) 60 Fig.9 UNDR FAST A 4 Press the MAXHLD key again and MAXHOLD will be displayed. (See Fig.10) The meter is now ready to measure the actual machine noise. 60 Fig.10 UNDR FAST A MAX HOLD 5 Turn on the machine you want to measure and note the new sound level reading. This number represents the sound level of the device without the background noise. If there is no change in the reading, the background noise is greater than the noise of the device. 6 Press the MAXHLD key and then the BA MODE key to exit background noise absorber mode.

BACKLIT KEY (8922 only) Offer a light for approximate 5 seconds to make it easier to see the display in the dark. SELECTING AUTOMATIC AND MANUAL RANGING The meter features six measurement ranges in 10dB steps: 30~80dB, 40~90dB, 50~100dB, 60~110dB, 70~120dB, 80~130dB. When you turn the meter on, it will be in automatic range mode and a small AUTO will be displayed on the left side of the screen (See Fig.11). In this mode, the meter will adjust the measurement range automatically for accuracy. The two digit number to the left of the bar graph on the LCD will show the low end of the current range. You can also set the range manually. This is helpful when you know the measurement range in advance. The meter will be able to take readings more quickly, because the unit does not need to first establish the range before displaying the measurement. Fig.11 Fig.12

TO ADJUST THE RANGE MANUALLY: 1 When measuring sound levels,press the DOWN and UPPER keys as needed to adjust the measurement range. MANU will appear on the display (See Fig.12).Note that the two digit number to the left of the bar graph will change to reflect the low of the newly selected range. If the meter is operating in manual range and UNDR is displayed (See Fig.13), the sound is too low or the range. If UPER is displayed (See Fig.14),the sound is too loud. In either case, you must adjust the measurement range or your readings will be incaccurate. UNDR UPER Fig.13 Fig.14 2 Press and hold the DOWN or UPPER key to switch back to automatic ranging.(see Fig.11) AUTOMATIC SHUTOFF The meter will turn off automatically after 20 minutes to preserve the battery.

To override the Auto Shut Off feature: 1 Make sure the unit is turned off. 2 Press the ON/OFF and MAXHLD buttons simultaneously. 3 When the full display appears, release the MAXHLD button first. "n" will appear on the screen in one second (See Fig.15), then enter the power on mode ; i.e. count down from: 99.9 88.8 77.7 66.6 55.5 44.4 33.3 22.2 11.1 00.0 and then a current sound level measurement is started. Fig.15 4 Release the ON/OFF key. The meter will remain on until the ON/OFF button is pressed again. The automatic shutoff feature will resume the next time the meter is turned on. REPLACING THE BATTERY When the entire display flashes, the 9V battery has fallen to a critically low voltage level and should be replaced as soon as possible. Use a screwdriver to unscrew the back battery compartment cover. Insert a fresh 9V battery and replace the cover.

Applicable Standards Measurement Level A Weighting Measurement Level C Weighting Measurement Level Range Automatic Range30~130dB Time Weighting Fast and slow Segment Range 50dB Digital Display SPECIFICATIONS IEC 651 Type 2, ANSI S1.4 Type 2 Measurement 31.5Hz~8KHz Frequency Range 1.5dB(Under reference Accuracy conditions) 30dB~130dB 35dB~130dB 6 ranges in 10dB steps: 30~80dB, 40~90dB, 50~100dB, 60~110dB, 70~120dB, 80~130dB 3 1/2 digit LCD, 0.1dB resolution updated every 0.5 seconds Quasi-Analog BarIndicator Microphone Analog Output Size Weight Operating Temperature Storage Temperauture Battery 1dB display steps, 50dB display range, updated every 50ms 6mm diameter Electret condenser microphone AC: 0.707Vrms (at full scale), DC: 10mvDC/dB 80mm x 256mm x 38mm (3" x 11" x 1.5") 240g(10.3oz) o 4~50 C, 10~90% Relative Humidity o -20~60 C 9V Battery

RS232 OUTPUT: The meter can link with personal computer to capture on-line datas, display presure records with real-time output, you can retrieve file, save the datas for operating data analysis, records statistic, multi-files display in the screen,...versatile functions for your choice. Connection procedures: 1. Plug the optional accessory RS232 cable onto the DC jack port ( at the right side of the meter) 2. Instert the D-sub 9P type connector onto computer's Com.1 or 2 port or... 3. Start to set up RS232 software by inserting the CD-ROM or Floppy diskette. 4. When installing the RS232 software, please follow the operation manual procedure in the software package.

MATERIAL SUPPLIED This standard package contains: 1. The meter x 1 2. Battery x 1 (9.0 volt) 3. Operation manual x 1 4. Buffer x 1 5. Hard Carrying case x 1 Optional accessory: a) RS232 software CD-R. b) D-sub connector. CE CERTIFICATION The meter conforms to the following standards: EN 50081-1/1992 : EN 55022 EN 50082-1/1997 : (EN 61000-4-2/-3/-8,ENV 50204) The meter complies with the essential protection requirements of Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. RETURN AUTHORIZATION Authorization must be obtained from the supplier before returning items for any reason. When requiring a RA ( Return Authorization), please include data regarding the defective reason, the meters are to be returned along with good packing to prevent any damage in shipment and insured against possible damage or loss.