Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Similar documents
Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Immersion Temperature Sensors

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room Temperature Controller

Room unit with PPS2 interface

Room Temperature Controllers

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Semi flush-mounted room temperature controllers with LCD

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Room Temperature Controller

Universal Controller

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Room unit with PPS2 interface

Resistance measuring module

Semi flush-mounted room temperature controllers with LCD

Power supply module, bus connection module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Room unit with PPS2 interface

Master room unit for RRV controllers

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Heating Circuit Controller

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

Semi Flush-mount Room Temperature Controllers with LCD

Electrical Actuators

ERF910. RF Repeater. Synco living

Electrical Actuators

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8RB. TX-I/O Blinds module

Digital input modules

M-Bus Central Unit. Use

Electrical Actuators

Room unit with PPS2 interface

Super universal modules

Temperature Controller

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Heating Circuit Controller

Electromotoric actuators

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

SEH62.1. Digital Time Switch

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Temperature controller Ducted systems

Product and functional description

Overview of types. Technical data

Rotary version, three-position control

Weekday / weekend room temperature controller

Electrical actuators

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Product and functional description

7-day room temperature controller

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

VAV modular controller

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

7-day room temperature controller

Fast running actuators for air dampers

Temperature Controller (Heat Pumps)

Multi-range pressure and differential pressure transmitter

VAV compact controller GDB181.1E/3 GLB181.1E/3

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Central control unit

Web interface BACnet/IP

Precision thermometer Model CTR2000

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Product and Application Description

Switching and Monitoring Device

Flush-mount room sensor

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Status display unit with P-bus connection

Precision thermometer Model CTR5000

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electromotoric actuators

Extension module for lighting control

Electromotoric actuators

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

MINI-PS AC/10-15DC/8

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

VAV compact controller KNX / PL-Link

EY-RU 355: Room operating unit, ecounit355

Island bus expansion module

itemp TMT180 Technical information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Room automation station

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Air damper actuators

Compact universal controllers

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Transcription:

1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal output DC 0...10 V / 4 20 ma for relative humidity and temperature Very high measuring accuracy across the entire measuring range Capacitive humidity measurement Recalibration service Test function for loop test Range of use 40 +70 C / 0 100 % r. h. with LCD display -25 +70 C / 0 100 % r. h. Use The QFA41 sensor is used in ventilation and air conditioning plants requiring: Very high accuracy and reliability for measuring relative humidity and temperature Regular recalibration and readjustment of the sensors Examples: Storage and production facilities in the paper, textiles, pharmaceutical, chemical, electronics industries, etc. Laboratories Hospitals Computer centers Greenhouses CE1N1859en 13.03.2008 Building Technologies

Type summary Type reference measuring range signal output measuring range signal output Operating voltage Measured value display QFA4160 0...50 C / 40 +70 C / aktive, DC 0...10 V 0...100 % aktive, DC 0...10 V AC 24 V or No QFA4160D 0...50 C / 40 +70 C / aktive, DC 0...10 V 0...100 % aktive, DC 0...10 V AC 24 V or Yes QFA4171 0...50 C / 40 +70 C / aktive, 4 20 ma 0...100 % aktive, 4 20 ma No QFA4171D 0...50 C / 40 +70 C / aktive, 4 20 ma 0...100 % aktive, 4 20 ma Yes Ordering and delivery When ordering, please give name and type reference, e.g.: Room sensor QFA4160 Place a separate order for the service set AQF3153 listed under accessories. The circular connector with its screwed plug is delivered uninstalled. Equipment combinations The QFA41 is for use with all types of systems and devices that can acquire and handle the sensor s DC 0...10 V or 4 20 ma output signal. Technical design Relative humidity Burden diagram The sensor acquires relative humidity via its capacitive sensing element whose capacitance varies as a function of the relative humidity of the ambient air. An electronic circuit converts the sensor s signal to a continuous DC 0...10 V or 4 20 ma signal, corresponding to a relative humidity of 0...100 %. The sensor acquires the temperature via its sensing element whose electrical resistance varies according to the temperature of the ambient air. This variation is converted to an active DC 0...10 V or 4 20 ma output signal, corresponding to a temperature range of 0...50 C, 35...+35 C or 40...+70 C. The measuring range can be selected. Output signal, terminai I1 / I2 900 800 1859D02en Burden [Ohm] 700 600 500 400 300 Inadmissible range! Admissible range 200 100 0 0 10 20 30 40 Operating voltage [DC V] Mechanical design The room sensor consists of housing, printed circuit board, connection terminals, measuring tip and circular connector. The housing consists of 2 parts: Base and removable cover (screwed). 2/7

A rubber seal is installed between housing and cover in order to satisfy the requirements of IP 65 degree of protection. The measuring circuit and the setting element are accommodated on the printed circuit board inside the cover, the connection terminals on the base. Housing and measuring tip are screwed together. The measuring tip features a degree of protection of IP40. The sensing elements are located at the end of the measuring tip, protected by a screw-on filter cap. Cable entry is made via the circular connector, which consists of coupling piece with M16 thread and connector with screwed plug. The coupling piece is secured to the housing and internally wired. The sensor is designed for wall mounting. Measured value display The types QFA4160D and QFA4171D with LCD display shows the following values: : in C or F : in % Setting elements Range 1 2 3 Measuring range 123 Test function active U1 U2 I1 I2 F C 10 V 20 ma QFA41...D Display temperature unit F C 0 V 10 V 0 V 4 ma 20 ma 4 ma 1859Z03en The setting elements are located inside the cover. A setting element is consisting of 6 pins and a shorting plug. It is used for selecting the required temperature measuring range and for activating the test function. Types with LCD display have a second setting element with 4 pins and a shorting plug. The different shorting plug positions have the following meaning: For the active temperature measuring range: Shorting plug in the left position (R1) = 35...+35 C, Shorting plug in the mid position (R2) = 0...50 C (factory setting) Shorting plug in the right position (R3) = 40...+70 C For the active test function: Shorting plug in the horizontal position: The values available at the signal output are those given in the table Test function active For the measured value display (QFA41 D) - Shorting plug vertical in the right position = C (factory setting) - Shorting plug vertical in the left position = F Behavior in the event of fault Calibration certificates Service set AQF3153 If the temperature sensor is faulty, the voltage at signal output U2 (I2) is 0 V (4 ma) after 60 seconds, the humidity signal at signal output U1 (I1) increases to 10 V (20 ma) If the humidity sensor is faulty, the voltage at signal output U1 (I1) is 10 V (20 ma) after 60 seconds; the temperature signal remains active The sensor and its exchangeable AQF4150 measuring tip are numbered, registered and calibrated prior to delivery. The associated calibration certificates are supplied with the sensor. The service set comprises there three measuring tips without sensor element. Each tip signals a predefined temperature and humidity value to the basic unit: 3/7

85%, 40 C 50%, 23 C 20%, 5 C The fixed values are available at the signal outputs. The measuring tips can be exchanged in operation. The service set allows for easy and quick loop test performance as recommended by Vertical Market Pharma and offered by their calibration service in various countries. Accessories Name Measuring tip certified (exchangeable) Service set (for loop test) Filter cap (for replacement) Type reference AQF4150 AQF3153 AQF3101 Engineering notes Use a safety extra low-voltage (SELV) transformer with separate windings designed for 100 % duty. All safety regulations valid at the location of the plant must be observed when sizing and protecting the transformer. When sizing the transformer, the sensor s power consumption must be taken into consideration. For the electrical connection of the sensor, refer to the Data Sheets of the devices with which the sensor is used. The maximum permissible cable lengths must be observed. Cable routing and cable selection Note to QFA4171(D) For cable routing, it should always be considered that electrical interference is the greater, the longer the cables run parallel and the smaller the distance between them. Use shielded cables if necessary. Twisted pairs of cables are required for the secondary supply lines and the signal lines. Terminals G1(+) and I1( ) for the humidity output must always be connected to power, even if only the temperature output G2(+) and I2( ) is used! Mounting notes Mounting location Caution! Mounting position Mounting Instructions Inside wall (not on outside wall!) of the room to be air conditioned; not in recesses, shelves, behind curtains, above or close to heat sources; not on walls behind which a chimney is located. The sensor must not be exposed to direct solar radiation. Install the sensor in the occupied space about 1.5 m above the floor and at least 50 cm from the next wall. The seal between housing and cover must not be removed, or else degree of protection IP 65 will be no longer ensured. The sensing elements inside the measuring tip are sensitive to shock and impact. Avoid any such impact on mounting. The QFA4160 must not be mounted with the measuring tip pointing upward. Mounting Instructions are printed on the inner side of the package. Commissioning notes Prior to switching on power, check wiring. On the sensor, select the required temperature measuring range. 4/7

Recalibration service SBT HVAC Products provides a recalibration service for used sensors. Recalibration should be performed at 12-month intervals under "normal" conditions, i.e. within the comfort range for humidity and temperature, and at air contamination levels that are not above average. Services provided The recalibration service includes the following: Delivery and invoicing of the new AQF4150 measuring tip complete with calibration certificate Delivery of a calibration certificate for the (old) measuring tip returned to SBT HVAC Products, enabling the customer to assess the time of usage of the measuring tip Technical data Power supply Cable lengths for the measuring signal Functional data sensor" Functional data " sensor" Degree of protection Electrical connections Environmental conditions Materials and colors Operating voltage Frequency Power consumption AC 24 V ± 20 % or DC 13.5...3 50 / 60 Hz at AC 24 V 1 VA Max. perm. cable lengths refer to Data Sheet of the device handling the signal Measuring range 0...100 % r.h. Measuring accuracy at 23 C and AC 24 V 0...100 % r.h. ± 2 % dependency Time constant 0.05 % r.h./ C < 20 s Output signal, linear (terminal U1) DC 0...10 V 0...100 % r.h., max. ± 1 ma Output signal, linear (terminal I1) Burden Measuring range 4 20 ma 0...100 % r. h. refer to "Function" 0...50 C (R2 = factory setting), (R1), 40...+70 C (R3) Sensing element Pt 1000 class B to DIN EN 60 751 Measuring accuracy at AC 24 V in the range of 15...35 C 35...+70 C ± 0.6 K ± 0.8 K Time constant 8.5 min. (according to airflow and wall coupling) Output signal, linear (terminal U2) DC 0...10 V 0...50/ 35...+ 35/ 40...+70 C ± 1 ma max. Output signal, linear (terminal I2) Burden Housing Safety class III to EN 60 730 Connector with screwed plug Screw terminals for Cable entry Operation Climatic conditions (housing with electronics) LCD-display readable Mechanical conditions Transport to Climatic condition Mechanical conditions Base Housing cover measuring tip Filter cap 4..20 ma 0...50/ 35...+ 35/ 40...+70 C refer to "Function" IP65 to IEC 60529, measuring tip IP40 Lumberg RSC 4/9 0.75 mm 2 max. 4 8 mm dia. class 4K2 to IEC 60721-3-4 40...+ 70 C 25...+ 70 C 0...100 % r.h. (with condensation) class 3M2 to IEC 60721-3-3 IEC 60721-3-2 class 2K3 40...+ 70 C < 95 % r.h. class 2M2 polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey). 5/7

Standards Weight Circular connector Connector with screwed plug Contact carrier and body Knurled nut and contact Coupling piece Contact carrier Casing and contact Sensor (entirely) Packaging Lumberg RSC 4/9 PA, black CuZn, nickel-plated Lumberg RKFM 4/0.5 M TPU CuZn, nickel-plated silicon-free corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions conformity to conformity to Australian EMC framework Radio Interference Emission Standard conformity UL 873 Incl. packaging Without LCD-display With LCD-display AQF3153 AQF4150 EN 61 000-6-1 EN 61 000-6-3 EMC directive 2004/108/EC Radio Communication Act 1992 AS / NZS 3548 0.196 kg 0.221 kg 0.066 kg 0.050 kg Connection terminals QFA4160(D) G (R1 = 35...+35 C / R2 = 0...50 C / (r.h.) R3 = 40...+70 C) G0 U1 U2 1858G01 G0 (3) U1 (2) 3 2 4 1 G (4) U2 (1) 1883G02 Front view: Connector fitted, body removed QFA4171(D) G1 (r.h.) I1 G2 (R1 = 35...+35 C / R2 = 0...50 C / R3 = 40...+70 C) I2 1858G03 I1 (3) G2 (2) 3 2 4 1 G1 (4) I2 (1) 1859G04 Front view: Connector fitted, body removed G, G0 Operating voltage AC 24 V (SELV) or DC 13.5...3 G1, G2 Operating voltage DC 13.5...3 U1 Signal output DC 0...10 V for relative humidity 0...100 % U2 Signal output DC 0...10 V for temperature range 0...50 C / 40 +70 C / I1 Signal output 4 20 ma for relative humidity 0...100 % I2 Signal output 4 20 ma for temperature range 0...50 C / 40 +70 C / Note on connection terminals of the QFA4171(D): Terminals G1(+) and I1 ( ) for the humidity output must always be connected to power, even if only the temperature output G2 (+) and I2 ( ) is used! 6/7

Dimensions (41 with display) 80 39 62,8 84 57 1859M01 60 41 AQF4150 ø 15 10,5 14,5 Dimensioning without (with) LCD-display Dimensions in mm 2006 2008 Siemens Switzerland Ltd. Subject to change 7/7