Click! 301. Serial to Ethernet Converter

Similar documents
Bluetooth to Serial Converter TOP FRONT. Click 421

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

Cabinet Interface Device

Click Desktop Kit. Click Desktop Kit

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Intersection Preassembled Backplate DC

2U Congestion Alert Rack Insert for UK

Install Kit. Install Kit

Intersection Segmented Backplate

8-Port 10/100BASE-TX Hardened Ethernet Extender Switch

FieldServer X-25 Start-Up Guide

UK +44 (0) // USA // JAPAN //

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

UK +44 (0) // USA // JAPAN //

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

Command Viewpoint. Command Viewpoint

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Hardened PoE Ethernet Switch

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Industrial 2-port RS422/485 Modbus Gateway

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

8~14-Port Managed Ethernet Switch

Command Travel Time System

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

AB Axis Industries. Use

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

Signamax Connectivity Systems

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

UK +44 (0) // USA // JAPAN //

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Ethernet. RJ45 Copper Ports

ES-600 Ozone Controller Operation Manual

Industrial 1-port RS422/485 Modbus Gateway

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

5-Port Industrial Ethernet Switch - DIN Rail Mountable

Hardened Media Converter

Gathers real-time data from traffic detection devices at intervals as

Industrial Ethernet Switch

BusBlock Digital I/O Module for the Smart Distributed System

Serial/Ethernet Converter

Ethernet to Digital I/O +RS232 +Switch

BACnet/IP to BACnet MS/TP Router

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

XPress-Pro SW User Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide

VIP-812A DUAL NETWORKED STATION PORT

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Chapter 1 Product Introduction

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

KFC-200. Installation Guide

COMPACT FLEXIBLE ALL IN ONE INDUSTRIAL PUMP CONTROL ELECTRONIC MONITORING SYSTEM CONTROLLER

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

316TX-N. Phone: Fax: Web: -

Installing the IPS 4345 and IPS 4360

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

BusBlock Analog Input Module for the Smart Distributed System

LC0 DVP

Command Suite. Command Suite

PT-7728/7828 Quick Installation Guide

VIP-480AL IP One-Way Horn

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Industrial Media Converters

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Guide Specification for 3G Wireless Battery Monitoring System

iconverter 2-Module Power Chassis

INTMOD485-LH Protocol Converter

General Purpose Chassis for PXI and CompactPCI

Project Documentation TMIB Data Sheet

Crestron CEN-SW-POE-5 5-Port Power over Ethernet Switch Installation Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

SNAP Compact Fiber Optic Patch Panel

10/100Base-TX Industrial Ethernet Extender

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

Industrial PoE Media Converter

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

IMC-21A Quick Installation Guide

32 x 32 Modular Matrix Switch

Stride Industrial Ethernet Switches

10/100Base-TX Industrial Ethernet Extender

DeltaV SD Plus Controller

304TX-N. Phone: Fax: Web:

Transcription:

Serial to Ethernet Converter The Click! 301 converts half-duplex RS-232 & RS-485 communication to Ethernet and vice versa. This device, tested to work over a 34 C to 74 C temperature range, can be used as part of a traffic cabinet to communicate between devices via Ethernet connections. Features Converts half-duplex serial to Ethernet and vice-versa Multiple communication ports, including RS-232, RS-485 and Ethernet Auto-configures baud rates Can be configured over either Ethernet or serial interfaces Snaps onto DIN rail for quick and easy installation Three LEDs on faceplate of device allow for easy monitoring of device functionality Supports Click! Supervisor for easy setup and configuration on your computer Allows auto-reset of inactive sockets Applications include: àà Controller closed loop Ethernet àà Sensor to Ethernet Conformal coated Available in DIN rail, rack or controller card modules WX-500-0109 1

Technical Specifications Physical Weight: 0.2 lbs. (0.1 kg) Physical dimensions: 4.5 in. 4 in. 0.9 in. (11.4 cm x 10.2 cm x 2.3 cm) Ambient operating temperature: -29 F to 165 F (-34 C to 74 C) Humidity: up to 95% RH Mounting DIN rail mountable Power Power supply voltage: 10 to 30 Uses less than 1 W of average power at 24 Connections Device has the following connection points: àà Power: 5-position connector for connecting from the T-bus àà RS-232: Through a DB-9 connector àà RS-485: 5-position connector for connecting from the T- bus as well as one pluggable screw terminal àà Ethernet: one RJ-45 jack on the front of the device Communication Converts RS-232 to RS-485 and vice versa Communicates serial to Ethernet and vice versa Baud Rates Supports the following baud rates: àà 1200 bps àà 2400 bps àà 4800 bps àà 9600 bps àà 19200 bps àà 38400 bps àà 57600 bps àà 115200 bps Configuration Features Push-button has the following functions: àà Autobauds device to a SmartSensor or other serial device àà Resets device to factory defaults LEDs: àà Red LED illuminates when device has power àà Yellow LED (TD) illuminates when data is transmitted àà Green LED (RD) illuminates when data is received Pocket PC & PC Configuration Software Comes with Click! Supervisor, configuration software with the following features: Ordering Information Part Number WX-CLK-301 Wavetronix 78 East 1700 South Provo, UT 84606 Phone: 801-734-7200 Fax: 801-734-7201 Email: sales@wavetronix.com Website: www.wavetronix.com àà Runs on both a Pocket PC and a Windows desktop or laptop PC (Windows 2000 and newer) àà Configures serial communication settings including the serial baud rates àà Can remotely and directly upgrade the device firmware to add new features to the device àà Allows users to save a configuration to a file, and to open existing files and save to a device, allowing a common configuration to be easily programmed into many devices àà Has customizable drivers that are stored as XML files that describe the graphical user interface for that driver Remote Upgradeability Flash memory can be remotely upgraded to add functionality to the firmware when new features have been developed to improve the performance of the installation NEMA TS2-1998 Testing Complies with the applicable standards stated in the NEMA TS2-1998 Standard Test results available for each of the following tests: àà Shock pulses of 10g, 11 ms half sine wave àà Vibration of.5 Grms up to 30 Hz àà 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage àà Stored at -49ºF (-45ºC) for 24 hours àà Stored at 185ºF (85ºC) for 24 hours àà Operation at -29.2ºF (-34ºC) and 10.8 àà Operation at -29.2ºF (-34ºC) and 26.5 àà Operation at 165.2ºF (74ºC) and 26.5 àà Operation at 165.2ºF (74ºC) and 10.8 Testing Tested by manufacturer before shipping 2 www.wavetronix.com

Extended Support Extended support options are available from Wavetronix; contact a Wavetronix representative for more information Warranty One-year warranty against material and workmanship defect 3

Bid Specification 1.0 General. This item shall govern the purchase and installation of a hardened RS-485 and RS-232 serial to Ethernet converter module (SECM) equivalent to the Wavetronix Click! 301 that is used to convert two-wire RS-485 communications and RS-232 to IP-addressable Ethernet standard. Test results and other documentation demonstrating performance and capabilities shall be provided. 2.0 Product Description. The SECM shall be a converter module for use with radar vehicle sensing devices (RVSD) equivalent to the Wavetronix SmartSensor. The SECM shall be capable of converting two-wire half-duplex RS-485 communication and RS-232 communication to IP-addressable Ethernet protocol and vise versa. All serial ports shall pass data on one port to all other ports. Any data coming to or from the Ethernet port shall simultaneously be sent to all RS-485 and RS-232 ports. 3.0 Physical. The SECM shall not exceed 0.2 lbs. (0.1 kg) in weight. The SECM shall not exceed 4.5 in. 4 in. 0.9 in. (11.4 cm x 10.2 cm x 2.3 cm) in its physical dimensions. The SECM shall operate within a temperature range of -29 F to 165 F (-34 C to 74 C). The SECM shall operate in humidity up to 95% RH. 4.0 Mounting. The SECM shall mount to a DIN rail with hotswappable power and communication buses for quick installation and replacement. 5.0 Power. The SECM shall have a power supply voltage of 10 to 30. The SECM shall operate using less than 1 W of average power at 24. 6.0 Connections. The SECM shall include the following connections for power and communication: 6.1 Power. The SECM shall include a 5-position connector, with two contact points reserved for connecting power through the bus. 6.2 RS-232. The SECM shall feature a DB-9 connector for RS-232 communication. 6.3 RS-485. The SECM shall feature a pluggable screw terminal for RS-485 communication. The 5-position connector shall have three contact points reserved for connecting RS-485 through the bus. 6.4 Ethernet. The SECM shall feature an RJ-45 jack for Ethernet. 7.0 Communication. The SECM shall have the following communication capabilities: 7.1 Serial Protocol Conversion. The SECM shall allow communications with any serial device that has a serial connection by converting 2-wire half-duplex RS-485 communication to half-duplex RS-232 communication, and vice versa. 7.2 Ethernet. The SECM shall convert RS-232 and RS-485 protocol to Ethernet, allowing communication with any device connected to the SECM via an Ethernet network. 8.0 Baud Rates. The SECM shall support baud rates of 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600 bps and 115200 bps. 9.0 Configuration Features. 9.1 Push-button. The front of the SECM shall include a push-button that causes the SECM to autobaud to a SmartSensor or other serial device. It shall also be able to reset the SECM to factory defaults. 9.2 LEDs. The front of the SECM shall include a red LED for power and green and yellow LEDs, which shall illuminate when corresponding data is successfully transmitted or received. 10.0 Pocket PC & PC Configuration Software. The SECM shall be provided with configuration software that: Runs on both a Pocket PC and a Windows desktop or laptop PC (Windows 2000 and newer) Configures serial communication settings including the serial baud rates Can remotely and directly upgrade the SECM firmware to add new features to the SECM Allows users to save a configuration to a file, and to open existing files and save to a device, allowing a common configuration to be easily programmed into many devices Has customizable drivers that are stored as XML files that describe the graphical user interface for that driver 11.0 Upgradeability. The SECM shall have flash memory that can be remotely upgraded to add functionality to the firmware when new features have been developed to improve the performance of the installation. 12.0 NEMA TS2-1998 Testing. The SECM shall comply with the applicable standards stated in the NEMA TS2-1998 4 www.wavetronix.com

Standard. Test results shall be made available for each of the following tests: Shock pulses of 10g, 11 ms half sine wave Vibration of 0.5 Grms up to 30 Hz 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage Cold temperature storage at -49 F (-45 C) for 24 hours High temperature storage at 185 F (85 C) for 24 hours Low temp, low DC supply voltage at -29.2 F (-34 C) and 10.8 Low temp, high DC supply voltage at -29.2 F (-34 C) and 26.5 High temp, high DC supply voltage at 165.2 F (74 C) and 26.5 High temp, low DC supply voltage at 165.2 F (74 C) and 10.8 13.0 Testing. Before shipping, each SECM shall have passed a manufacturer s test. 14.0 Extended Support. Extended support options shall be available. Contact the manufacturer s representative for more information. 15.0 Warranty. The SECM shall be warranted to be free from material and workmanship defects for a period of one year from date of shipment. 5