Manual. ZIG-NANO Wireless Transmitter. Installation Maintenance Repair Manual CONNECTED ON:01

Similar documents
Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

MicroVision Timer MICROPROCESSOR TIMER CONTROLLER. Installation Operation Manual Rev.F Page 1 of 30

Innovative Circuit Technology Ltd.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

PT35. Dual Pulse Timer Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual

Manual. Touch Screen Controller. Installation Maintenance Repair Manual

CR87B TEMPERATURE RECORDER

KBMG MULTI-SPEED BOARD

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

IEXT224-4PH-L IEXT224-4PH-R Long Reach POE Extenders

MEGA DIAL PANEL Instructions

Seven Channel Remote Control

CMSA-100 Manual. Cinema Media Server Automation

EPS Power Supply

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Application Guide. M 2174B Moloney Replacement Adapter Panel

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

Innovative Circuit Technology Ltd.

Zonit μats TM Users Guide μats1-lv Version 1.2

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Ratio Feeder Series J+ Advanced Pumper Controller

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

User's Guide. Model High Precision Quad Output DC Power Supply

Quick Start Guide. ELPRO 905U-L Wireless I/O Receiver Unit. man_905u-l-r_quickstart_v1.9.doc

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

1-36V, 0-3A DC Power Supply

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Global Water globalw.com. Global Water. Instrumentation, Inc.

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Relay Board. User Manual. 1.0, Oct 2013

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Model HM-535 Power Supply Installation and Service Instructions

Wa r n i n g-wa r n i n g-wa r n i n g

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299

Sidewinder Pumps Inc. AC Timer/Controller

Resolver to Digital Expansion Board

Owner's Manual. For latest instructions please go to

Global Water globalw.com. Global Water. Instrumentation, Inc.

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Broadband Automatic Disconnect Switch. User Manual

CA-A480-A Elevator Controller. Reference & Installation Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

TB-100 ControLynx Terminal Block

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( )

G2M Control Board Installation and Operations Manual

FNet Repeater Installation & Operator s Instruction Manual

iconverter 2-Module Power Chassis

Install Motor Controller User Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

LED FOLDING WORKLIGHT TM

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MTX-A Temperature Gauge User Manual

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

MFJ ENTERPRISES, INC.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Chore-Tronics Mobile Server

EverPump Wireless Pump control system

MFJ ENTERPRISES, INC.

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Manual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

I/O Expansion Box Installation & Operator s Instruction Manual

OZONE SWITCH Model OS-6. OS-6 Features

Series 803 LED Product Price Display

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

OilCop Component Wiring Installation Manual

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Progressive Industries, Inc. EMS Electrical Management System

87421/22A Power Supply. Operating and Service Manual

1-channel MPEG-4 Video Encoder ACD-2100T. Ver User s Manual 0-0

Product Documentation

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

PICO PROTECTOR PG-25 & PK-25 Series

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

PanelView Plus/VersaView CE Terminals and Display Modules

Owner s Instruction Manual

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

SMI-100 Stack Monitoring Interface Installation & Operation Manual

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

MT8050iE series. Installation Instruction (1) (2)

INSTALLATION INSTRUCTIONS

Manual. Controller. Installation Maintenance Repair Manual

Transcription:

Manual ZIG-NANO Wireless Transmitter Installation Maintenance Repair Manual CONNECTED ON:01 Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com 08/2017 1

Table of Contents Contents Page I. Introduction... 2 II. Description... 3 ZIGR-NANO Features... 3 ZIGB- NANO Featrues... 3 III. Installation Electrical Wiring... 3 Logic and Relay Cards... 4 Mounting Instructions... 4 IV. Front Panel Description... 5 V. System Operation Overview... 5 Description of Menus... 5 VI. ZIGB-NANO Menu Map... 6 VII. ZIGR-NANO Menu Map... 7 VIII. Nano-to-Nano Remote Water Meter Installation... 8 IX. Nano-to-Nano Remote Relay Installation... 8 X. Nano-to-Nano Remote Digital Input... 9 XI. Warranty & 30 Day Billing Memo Policy... 10 I. Introduction NanoTron microprocessor based controllers are designed to provide a wide range of control functions for recirculating water treatment systems. The controller is programmed through a front panel keypad and can be configured to provide a customized control system for your application. Your particular unit s functions can be determined by comparing the units model number to the model numbering table listed below. Model Numbering NanoTron units have several base system control functions and unit optional features. Your unit may be supplied with one or more of the features described in this manual. To determine what features apply to your unit check the model number label located on the controller enclosure. Base Control Function ZIGB-NANO - Base Model (2 pulse outputs) ZIGR-NANO - Remote Model (2 relays, 2 digital inputs) Whole Unit Optional Features A - Conduit Connections A3 - Conduit with CE A7 - Australian power cord (240 VAC) W - Larger enclosure with clear lockable cover 2

II. Description NanoTron units are designed to automate the addition of various chemicals or activate other devices via a relay output. ZIGR-NANO units include: * Two totalizing water meter inputs that can be configured for contacting head or hall effect meter inputs. * Two mechanical relay outputs with normally open and normally closed contacts that can be configured for powered or dry contact relay operation (see page 4). * A force on timer (remote models only) that allows for manual activation of the relays for a user defined amount of time. ZIGB-NANO units include: * Two pulse outputs * Two dry contact inputs for relay control III. Installation General Safety Guideline Follow all safety guidelines outlined in this guide and/or marked on the unit. Never install or operate this product outside the specifications listed in this guide. Never install and operate in flammable or explosive environments. Install your unit in a location that is out of the reach of unauthorized personnel. Always install additional disconnect and safety devices to provide added protections. Never operate this product outside the environmental limits specified in this guide. Condition of Use This wireless system is not designed, intended or authorized for use in medical applications, applications intended to sustain or support life, in any nuclear facilities, or any other application where the failure of the product could create a situation where catastrophic property damage, personal injury, or death may occur. In the event that the Customer purchases or uses this product for any such unintended or unauthorized application, the Customer shall indemnify and hold harmless Advantage Controls and its officers, directors, employees, agents, affiliates, successors, and assigns against all claims, costs, damages, and expenses (including reasonable attorneys and expert witness fees) arising out of or in connection with such unintended or unauthorized use, even if such claim alleges that Advantage Controls and its affiliates was negligent regarding the design or manufacture of the subject product. Electrical Wiring The controller has an internal regulated power supply that will operate in the range of approximately 100 to 240 VAC on the incoming wiring. Output relay(s) are protected with a replaceable fuse. Relay output voltage will equal the incoming line voltage. Prewired units are supplied with a 16 AWG cable with a 3-wire grounded USA 120 volt plug for incoming power and 18 AWG 3-wire grounded receptacle cords for all control relay outputs. Conduit units are supplied with liquid tights and adaptors for easy hard wiring to supplied connector. NOTE: Liquid tight fittings and some labeled signal leads are provided for signal (low voltage) connections, such as water meter inputs. Warning 1. The controller should be connected to its own isolated circuit breaker, and for best results, the ground should be a true earth ground, not shared. Wiring must be done according to all applicable local codes. 2. Power (line voltage) must be disconnected while making any connections. If power is supplied to the unit, line voltage will be present on the relay cards. 3. Low voltage signal wires (probes, flow switch, water meter, etc.) should never be run in conduit with high voltage wires. 3

MICROCHIP Logic and Relay Cards Relay Card ZIG-NANO Logic Card Power In Ground Neutral Hot Neutral Ground N/O N/C Neutral Ground N/O N/C Powered relay output jumper configuration Reset Contrast Adjust Relay 1 Out Power Supply Relay 2 Out Dry contact relay output jumper configuration + - + - + - + - +5V Input 1 Input 2 Input 3 + - Input 4 + - Pulse 1 + - Pulse 2 Relay 1 FUSE FUSE Relay 2 Note: Use GND and N.O. for N.O. dry contact relay or use GND and N.C. for N.C. dry contact relay. Mounting Instructions Select a mounting location that provides the operator easy access to the unit and a clear view of the controls through the cover of the controller. The location should be convenient to grounded electrical connections, the needed sample line plumbing and is on a stable vertical surface.! WARNING: Avoid locations that expose the controller to direct sunlight, vapors, vibration, liquid spills or extreme temperatures; less than 0 F (-17.8 C) or greater than 120 F (50 C). EMI (electromagnetic interference) from radio transmissions and electric motors can also cause damage or interference and should be avoided. General Specifications Radio Frequency: 2.4 GHz Radio Protocol: IEEE Std. 802.15.4 Comm Distance: 3,000 ft. line of sight Operating Temp: 0 F to 120 F Wire Connections: Terminal Block, 14-30 AWG Output Power Protection: 5A 120/240 VAC Fast Blow Fuses 4

IV. Front Panel Description CONNECTED ON:01 1 2 MENU FORCE ON/OFF Press MENU to access menus or go back one layer in menu structure. Press FORCE to activate relays manually again for Off and a third time back to auto. Press to go a layer deeper in menu, to initiate a setting change and to set change. MENU FORCE ON/OFF Use up or down arrows to navigate through menu selections or setting options. Use left or right arrows to move cursor while making a numerical value change. V. System Operation Overview Description of Menus NanoTron controllers have three modes of operation, Run, Menu and Force. All menus are circular. Pressing the DOWN key will display the next line of information on the display. Run - This mode is for normal operation. The control relays will only be automatically active in this mode. In the Run mode, the display will read system values. If an alarm is present, the display flashes with the alarm status. The Run menu will display values such as day, time, date and other values depending upon the features present on the unit. The unit will automatically return to the Run mode if no keys are pressed for three minutes. Menu - Force - Force This mode is used to make adjustments to settings and readings on the controller. To access the Menu mode from the run screen, press the Menu key. Use the up or down arrow to scroll through the various menus. When you want to access a specific menu, press the Enter key. Once you have entered a sub-menu you will be able to step through that menu s options with the up or down arrow key. Relays on NANO-ZIGR may be forced on or off for a user defined amount of time. Press the key to force relays on for the time configured in the Menu s force sub-menu. Press it a second time to force them off for the same amount of time. Press a third time to go back to automatic Run mode. Unit returns to the Run mode automatically when the force time has elapsed. 5

VI. ZIGB-NANO Menu Map ZIGB-NANO Base Configuration Run Screen Indicator LEDs will turn red if connection is lost. Connected on: X REM FM1: 000 REM FM2: 000 RLY1/IN3 RLY2/IN4 Disabled if 0000. Configure Password 0000 Network Network XX Mode Base, Remote, or XS configuration CONNECTED ON:01 1 2 MENU FORCE ON/OFF Press MENU to access menus or go back one layer in menu structure. Press FORCE to activate relays manually again for Off and a third time back to auto. Press to go a layer deeper in menu, to initiate a setting change and to set change. Use up or down arrows to navigate through menu selections or setting options. MENU FORCE ON/OFF Use left or right arrows to move cursor while making a numerical value change. Note: If Menu is pressed while changing a value, the value on screen will be the new value. 6

VII. ZIGR-NANO Menu Map ZIGR-NANO Remote Configuration Run Screen Connected on: X IN1:FM 000 IN2:FM 000 Configure Network Force Set Disabled if 0000. Password 0000 Network XX Force On: Ask Mode R1 Cntrl 00:00 Debounce: 00.0 WM1: 0000000 Base, Remote, or XS configuration R2 Cntrl 00:00 Accumulated total displayed on both the Remote and Base. WM2: 0000000 Set Force On/Off key action here as: Ask, Both, Relay 1, Relay 2, or None. If the user selects None, the message Check Settings will appear on the run screen when Force On/Off is pressed. 7

VIII. Nano-to-Nano Remote Water Meter Installation 1. Power on the Base unit and select the Network portion of the main menu. Select a network identifier from 1-99. 2. Power on the Remote unit and select the Network portion of the main menu. Select the same network identifier that was used on the Base unit. If both units are powered, then the message CONNECTED ON: X will appear on the run screen of both the Base and Remote units. X will be the selected network identifier. 3. Mount the Remote unit in a location near the desired water meter. Refer to the Mounting Instructions section of the manual for more detail. 4. Remove the two screws on the front of the Remote unit to access the terminal headers on the circuit board. 5. Connect the two wire dry contact output of the water meter into either the Input 1 or Input 2 headers on the Remote unit. 6. Replace the two screws mounting the faceplate of the Remote unit. 7. Mount the Base unit in a location near the host controller. 8. Remove the two screws on the front of the Base unit to access the terminal headers on the circuit board. 9. Connect a two wire cable from either the Pulse 1 or Pulse 2 headers on the Base unit into the desired water meter input header of the controller. Pulse 1 from the Base unit will output the contacts received by Input 1 on the Remote unit. Pulse 2 from the Base unit will output the signal from Input 2 on the Remote unit. 10. Replace the two screws mounting the faceplate of the Base unit. IX. Nano-to-Nano Remote Relay Installation 1. Power on the Base unit and select the Network portion of the main menu. Select a network identifier from 1-99. 2. Power on the Remote unit and select the Network portion of the main menu. Select the same network identifier that was used on the Base unit. If both units are powered, then the message CONNECTED ON: X will appear on the run screen of both the Base and Remote units. X will be the selected network identifier. 3. Mount the Remote unit in a location near the relay controlled device. Refer to the Mounting Instructions section of the manual for more detail. 4. Plug the power cord of the relay controlled device into either the Relay 1 or Relay 2 pigtail of the Remote unit. 5. Mount the Base unit in a location near the host controller. 6. Remove the two screws on the front of the Base unit to access the terminal headers on the circuit board. 7. Configure and/or select the desired relay on the source controller to act as a dry contact output. 8. Connect a two wire cable from the dry contact output of the source controller to either the Input 3 or Input 4 headers on the Base unit. Input 3 on the Base will control Relay 1 on the Remote unit. Input 4 on the Base unit will control Relay 2 on the Remote unit. 9. Replace the two screws mounting the faceplate of the Base unit. 8

X. Nano-to-Nano Remote Digital Input 1. Power on the Base unit and select the Network portion of the main menu. Select a network identifier from 1-99. 2. Power on the Remote unit and select the Network portion of the main menu. Select the same network identifier that was used on the Base unit. If both units are powered, then the message CONNECTED ON: X will appear on the run screen of both the Base and Remote units. X will be the selected network identifier. 3. Mount the Base unit in a location near the desired dry contact output device. Refer to the Mounting Instructions section of the manual for more detail. 4. Remove the two screws on the front of the Base unit to access the terminal headers on the circuit board. 5. Connect the two wire dry contact output of the target device into either the Input 3 or Input 4 headers on the Base unit. Input 3 on the Base will control Relay 1 on the Remote unit and Input 4 on the Base unit will control Relay 2 on the Remote unit. 6. Replace the two screws mounting the faceplate of the Base unit. 7. Mount the Remote unit in a location near the host controller. 8. Remove the two screws on the front of the Remote unit to access the relay board. 9. Change both relays into their dry contact configuration. Refer to the relay card drawing for more details. 10. Connect a two wire cable from the GND and N/O positions on either Relay 1 or Relay 2 of the Remote unit into the desired digital input of the host controller. 11. Replace the two screws mounting the faceplate of the Remote unit. 9

XI. Manufacturer s Product Warranty Advantage Controls warrants units of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 24 months from date of installation. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer s examination. Removal and installation costs are not included under this warranty. Manufacturer s liability shall never exceed the selling price of equipment or part in question. Advantage disclaims all liability for damage caused by its products by improper installation, maintenance, use or attempts to operate products beyond their intended functionality, intentionally or otherwise, or any unauthorized repair. Advantage is not responsible for damages, injuries or expense incurred through the use of its products. The above warranty is in lieu of other warranties, either expressed or implied. No agent of ours is authorized to provide any warranty other than the above. 30 Day Billing Memo Policy Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service with minimum downtime. If your unit malfunctions, call 1-800-743-7431, and provide our technician with Model and Serial Number information. If we are unable to diagnose and solve your problem over the phone, a fully warranted replacement unit will be shipped, usually within 48 hours, on a 30 Day Billing Memo. This service requires a purchase order and the replacement unit is billed to your regular account for payment. The replacement unit will be billed at current list price for that model less any applicable resale discount. Upon return of your old unit, credit will be issued to your account if the unit is in warranty. If the unit is out of warranty or the damage not covered, a partial credit will be applied based upon a prorated replacement price schedule dependent on the age of the unit. Any exchange covers only the controller or pump. Electrodes, liquid end components and other external accessories are not included. FCC Warning This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instruction, may cause interference to radio communications. It has been type tested and found to comply with the limits for a class A computing device pursuant to subpart J of part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial or industrial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his own expense, will be required to take whatever measures necessary to correct the interference. 10

SET UP RUN CHANGE HELP Get the Advantage in Water Treatment Equipment Advantage Controls can give you the Advantage in products, knowledge and support on all of your water treatment equipment needs. Cooling Tower Controllers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems 1 2 3 4 5 1 2 6 3 7 4 8 5 9 0 HOME BACK Get the Advantage 11