Vevo770 Ultrasound. Quick Operation Guide AIPT

Similar documents
Quick Start Guide to the Vevo 770

Quick Start Guide to the Vevo 770

Beginner s Guide to Vevo 2100

Visualsonics Vevo2100: Manual for Collecting RF Data. Updated: 10/29/2012 M Kurowski

Imaging Guide Pancreatic Imaging

VisualSonics Vevo 770 High-Resolution Imaging System. Operator Manual

Quick reference guide. MyLab50

VEVO 1100 Sole Source Specifications

Semi-Interactive Console Layout and Instructions

10 Working With Setup Tools

10 Working With Setup Tools

VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents

ACUSON P300 Ultrasound System Control Panel Diagram

MyLab Alpha Quick Start

Quick Guide. EPIQ 7 Ultrasound System. English

SONOLINE G40 ultrasound system

Echo Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual

DataHub: FAQs/Troubleshooting

SONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1

TELEMED. Echo Wave II Software LB-2. Ultrasound Consolle. User Manual

Quick Guide Software Version 4.4

Medical Image Viewer Guide

Tutorial - Introduction to LabScribe and the IX-ELVIS

1 About the Terason Ultrasound System

Recipes4Success. Draw and Animate a Rocket Ship. Frames 5 - Drawing Tools

Nikon A1-B Confocal Operating Manual. Start-up. Microscope

Zeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol

Kids 'n Vue. User's Guide

VEVO 2100 Sole Source Specifications

Ambra User Guide. If you need help. Ambra Support (any time)

Get to Know the VideoStudio Workspace

Small rectangles (and sometimes squares like this

Using LoggerPro. Nothing is more terrible than to see ignorance in action. J. W. Goethe ( )

ZLog Z6R Altitude Data Recording and Monitoring System

Voxar 3D ColonMetrix. Reference Guide

Instructions for Doppler Image Cropping code

1 Place the iworx/214 unit on the bench, close to the computer. 3 When the dialog box appears, select ahk214.iws and then click Load.

The LabScribe Tutorial

Experiment 1: The LabScribe Tutorial

Remotely Accessible Healthcare at Home. User Guide for Devices

Capstone Appendix. A guide to your lab computer software

Gallios TM Quick Reference

On Call Imaging Specialists. We re here to assist you with questions about operating your equipment. Pocket Quick Guide. Software version 3.2.

Manual. User Reference Guide. Analysis Application. Cardiac Impedance (IMP) Customer Support: Phone: (888)

You need to use the URL provided by your institute s OMERO administrator to access the OMERO.web client.

ENVI Classic Tutorial: A Quick Start to ENVI Classic

BD CellQuest Pro Acquisition Tutorial

Mini Mini GlobiLab Software Quick Start Guide

Visual Physics - Introductory Lab Lab 0

Optimizing GRITS. In this chapter:

Student Quick Reference Guide

SF-1 Wireless Backfat & Loin Depth Scanner OPERATORS MANUAL

Adobe Flash CS4 Part 4: Interactivity

Roof Designer USER S GUIDE

PONEMAH V5.30 WITH NOLDUS MEDIA RECORDER 4.0 QUICK START GUIDE

GUIDE TO View3D. Introduction to View3D

CELLQuest Acquisition Tutorial

연구용유방초음파질관리 원광대학병원김혜원

KNOBOLOGY. Jamie Ternes, RVT William Beaumont Hospital Royal Oak, Michigan. From the Beginning

Living Image Software

How To Manually Update QuickBooks Point of Sale 2013 In A Multi User Environment To The Most Current Release Via Intuit s Website

THE EASTMAN Easicut v2.1

GE Medical Systems Training In Partnership LOGIQ 400. Quick Start Guide A Training in Partnership Program

WATER MAZE VIDEO TRACKING

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

Synapse Quick Guide PACS

Appendix E: Software

Optimizing ImmuNet. In this chapter: Optimizing Browser Performance Running Reports with Adobe Acrobat Reader Efficient Screen Navigation

Quick guide. Remote control. What it does How to do it Usability tips. Touch the glider gently, no need to press it. your thumb

IOP Horizons in Physics. Department of Physics University of Limerick

User Manual Version 1.1 January 2015

BioIRC solutions. CFDVasc manual

Exercise 4a: Creating and Editing XY Plots

Portable ultrasonic image diagnosis. Simple operating instruction Rev.2.5

NORDSON CORPORATION AMHERST, OHIO USA

Propel PRO User Guide

VI ViewerPlus Copyright 2018 Panasonic System Solutions Company of North America Version Last updated:

University of Minnesota Nano Fabrication Center Standard Operating Procedure

Contents... 1 Installation... 3

BioBeat User Guide. Warning

Personalize your pen with a color ring

Computer Basics. Page 1 of 10. We optimize South Carolina's investment in library and information services.

Alienware Elite Gaming Mouse AW958. User Guide

TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 USING WORD S MENUS... 3 USING WORD S TOOLBARS... 5 TASK PANE... 9

FREQUENTLY ASKED QUESTIONS

Image Optimisation. -How to Get the Most out of your Echo Machine. Katarina Winkler, Biomedicinsk analytiker, Barnhjärtcentrum i Lund

NewVission Portable Interactive Pad

Windows 10 - Starter Guide

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

For the Beginner: c) Click the settings tab to set screen resolution d) Set resolution with slider bar.

Overview of Synaptics TouchPad Features

Introduction to Computers By Jennifer King, YA and Marketing Librarian, Great Bend Public Library

Quick Start guide. for windows and mac. creative learning tools. Kar2ouche Quick Start Guide Page 1

USER'S GUIDE 4/25/2013

Wizard PDS. Automated Perimeter Definition System. January Education and Training Center Wizard Date 5/4/2016. Page 1

Digital Recorder End User Guide. Official UK distribution partner

SLS-ENVR4 Network Video Recorder V2.1 Quick Setup Guide

and Multiparameter Meters

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

Transcription:

Vevo770 Ultrasound Quick Operation Guide

Vevo770 Probe head (707B/704) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. The probe head should be filled with water all the time. If it has been drained; follow the procedures on this page. Position the RMV scan head with the fill port pointing upward. Fill the nosepiece with de-ionized water using the supplied water bottle until the nosepiece is almost full. Using your thumb, cover the fill port and tap the scanhead several times to dislodge any air bubbles in the nosepiece. Check to ensure that the face of the transducer does not contain bubbles. If bubbles appear, tilt the RMV scanhead to dislodge them. Orient the nosepiece so that the remaining air bubbles are placed under the fill port, and finish filling the nosepiece with the syringe. Insert and tighten the fill port screw with a screwdriver. Do not over-tighten the fill port. Real-Time Microvisualization (RMV) Scan Head Fill Port Screw Nosepiece Transducer Acoustic Membrane Nosepiece Pressure fit groove RMV cable Transducer Arm Acoustic Window

Pre-Image Preparation-Animal Preparation Warm up the stage The stage warmer, heart and temperature monitors each have a simple on/off button on the control pad. Located on the table to the left of the stage Turn on the stage heater-this helps to maintain mouse body temperature Study Subject Preparation ultrasound is most effective with no hair. Depilate the scan area of the animal using a razor or depilatory cream (Nair) Be sure to remove the NAIR as it can easily burn the mouse Put electrode contact gel (Sigma) or imaging gel on all 4 of the foot pads on stage base. Tape mouse down on platform so that all four of its feet are on the appropriate foot pad and in contact with the probe. This will monitor the mouse s heart rate and respiration the heart rate should be between approximately 370 and 400 beats per minute Prior to placing imaging gel on the mouse, take a small amount of gel and smooth it over the surface of the image area to remove small air bubbles at the skin level. Place 1-2 inches of gel on the image area, lower the scan head into the gel. Make sure to avoid bubbles. 3

Set up a study Turn on the instrument and computer The system main power switch is a large toggle switch on the back right hand side of the image.r PC power is activated by small toggle switch on the left side of the unit near the DVD drive-if this switch is not working, the main computer power button is below the console. Each user will log on to VEVO770 using your Kerberos username and password. You will be billed for the greater of your reserved time or your logged time. Please have the Menu same person make reservations and log on/off of the instruments. Open the Visual Sonics program, from the desktop icon If an error code comes up simply click okay. Initialize scan head Select or add operator Set up new study, click the New tab Fill in spaces for user and project info Select scanning mode from the keypad B-mode: basic scanning, two dimensional images and cine loops. Doppler Mode: measures velocity of blood flow from a field of view (FOV). Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Study Information Scan head initialization Study Browser New Study Scan Head selection (use default) Initialize Add Operator 4

Image acquisition/saving For all modes, start imaging in B-mode to identify an area of interest. If you want to have respiration and cardiac information included in the session, press the view tab on the tools menu. On the left side of the screen uncheck box for cardiac mode, with cardiac mode on, images will vibrate. Select the desired features. To save a single image select Frame Store, press Ctrl +L to label and save data. Menu tab View To save a video loop up up to 300 frames press Scan Freeze ; this tab will both start and stop data acquisition. The last 300 frames will be saved, to save the data press Cine Store then Ctrl +L to label and save the movie. At the conclusion of your study, in the Tool menu Study tab Close Study; Commit Session Data tab to save. -Data location is Data D: vevo770 \data\(your files) 5

Data transfer to the CCRBI2 server Data Transfer to the server -To transfer your data to the ccrbi2 file server you will need to map the drive as follows: Computer>tools>map network drive In the folder line type the following: \\ccrbi2\ccrbi2_data1\atwai\ (there is an underscore between ccrbi2 and Data1, not just a space) You will be asked for a username and password User name: ccrbi2\malstrom Password: Ray4eiph 6

B-Mode: basic scanning, two dimensional images and cine loops The line in this icon corresponds to the orientation ridge on the RMV scanhead and indicates the orientation of the RMV scanhead relative to the image. B-Mode ultrasound image window. The time-gain compensation (TGC) sliders specify the receive gain to be used for acquiring different sections of a B-Mode image. To toggle between the basic and detailed display parameters views, click Details or press <Ctrl+D>. The depth ruler indicates the depth from the transducer face. The triangular arrow indicates the focal length of the transducer. The grayscale bar indicates the dynamic range of the display. Cine loop playback controls. Physiological Data trace. The cine loop range control slider defines a subset of the cine loop to be played back or saved. 7

Define a Field of View (FOV) for PW Doppler studies Defining the Sample Volume and Doppler angle must be done in B-Mode. Defining the PW Doppler Sample Volume. Select Overlay > PW Doppler Sample Volume Wire-frame Move the trackball cursor over the red vertical line, left up click to move sample volume The trackball cursor is displayed as a crosshair when it is within a region that can be repositioned. Left-click the position line. Use the trackball cursor to move the overlay. Left-click again to place the Sample Volume. The Sample Volume details are updated in the parameters display. Defining the PW Doppler Angle. Start acquiring B-Mode data. From the B-Mode window, position the trackball cursor over the PW Doppler angle line (displayed as a dotted yellow or blue line). The trackball cursor changes to a crosshair. Right up-click to activate editing of the PW Doppler angle line. The angle line follows the movement of the trackball cursor. When the angle is at the desired setting, right-click to set the angle. VisualSonics recommends a PW Doppler angle that is between 0 and 60 for the most accurate velocity estimate. PW Doppler Sample Volume positioning line PW Doppler angle PW Doppler Sample Volume 8

PW Doppler Mode: measures velocity of blood flow from a field of view (FOV) Scout window Sample Volume position Angle measurement The frequency Scale indicates the frequency shift in the acquired PW Doppler signal. The grayscale bar indicates the dynamic range of the display. Time scale in milliseconds The image area is a right-to-left scrolling display. The most recently acquired data appears on the right of the window. ECG trace The velocity scale indicates the velocity of the measured PW Doppler signal. 9

Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Priority indicator Time-gain compensation (TGC) sliders Gray-scale bar Power Doppler Acquisition Parameters Power Doppler Histogram 10