C-Bus Ceiling Sweep Fan Controller L5501RFCP. Installation Instructions

Similar documents
C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DALI Gateway 5502DAL. Installation Instructions

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

DALI Gateway 5502DAL. Programming Guide

C-Bus Pascal Automation Controller

Line Controller 16-input, 8-output 2 DALI line, 1 DALI line DCBM DCBM Installation Instructions

C-Bus 4 Channel Voltage Free Changeover Relay L5504RVFC. Series. Installation Instructions

CLIPSAL CLIPSAL POWER MUTE < SOURCE > < VOLUME > Multi Room Audio Amplifier D/ R/ R User s Guide

USB ZB Interface Unit Ethernet ZB Interface Unit 5200UZI WHC2_ EZI WHC2_5922. User s Manual

C-Bus Four Channel Voltage Free Relay Installation Instructions

One Channel and Two Channel DALI Relay Device

Architectural Dimmer. L51xxDxxUA Series. Installation Instructions

C-Bus Eight and Twelve Channel Voltage Free Relay Installation Instructions

MLHG6. Iso-Gard Line Isolation & Overload Monitor (LIOM) Setup Guide ! WARNING. Components

Ethernet/DALI Interface 2 DALI Lines

C-Touch Spectrum Colour Touchscreen

LEDsmart+ Slave Relay Device

Translink Controller Installation Manual V1.0

C-Bus Two Channel Infrared Transmitter Unit Installation Instructions

RAPIX Lighting Control System - ehub

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide DANGER. Components

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Extension module for lighting control

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Operating instructions. Switching amplifier DN0210 DN / / 2015

FP-PS-4. Features. Installation

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Power supply module, bus connection module

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Operating instructions. Speed monitor D / / 2014


C-Touch Colour Touch Screen. 50x0CTC3 Series. Installation Instructions

MAXIMA+ Series Rotary Level Indicator

Operating and Maintenance Instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

VRp Three-Phase Precision AC Voltage Regulator

Installation Instructions

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

StarServe Harmonicas. Wiring Instructions. Shallow. Deep. Angled. Telephone Modules 8052/4RJ 8052/4RJDMB 8052/4RJSMB Angled 3105ATPP2X4

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MAXIMA + Series ROTARY LEVEL CONTROL

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

LCI User Manual mantracourt.com

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

CA-A480-A Elevator Controller. Reference & Installation Manual

Product and functional description

Operating Manual RISH DPM Hz

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Operating instructions Evaluation system for flow sensors VS / / 2013

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

RТTH DUAL ROOM SWITCH

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Temperature. Power requirements. Weight. Dimensions

PRODUCT SPECIFICATION. PC Board Relays. Series.

Weathersafe Vision. Installation & Operating Instructions

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

FLEX Ex Spring Clamp Terminal Base

THIS PAGE LEFT BLANK

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

C-Touch Colour Touch Screen. Installation Instructions 50xxCTC2 Series

PNOZ s1. Safety relays. Operating Manual EN-07

EX-RC1 Remote I/O Adapter

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

SoundwebTM. Installation Guide

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide


Digital input modules

NI 6521 Specifications

360 Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

Broadband Automatic Disconnect Switch. User Manual

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

DEEP SEA ELECTRONICS PLC

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

MAINS DISTRIBUTION UNIT MDU14-CO

Transcription:

L5501RFCP

Copyright 2009 Schneider Electric. All rights reserved. This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric. Clipsal and C-Bus are registered trademarks of Schneider Electric. All other trademarks are the property of their respective owners. The information in this manual is provided in good faith. Schneider Electric endeavours to ensure the relevance and accuracy of the information, but assumes no responsibility for any loss incurred as a result of its use. Schneider Electric does not warrant that the information is fit for any particular purpose, nor does it endorse its use in applications that are critical to the health or life of any human being. Schneider Electric reserves the right to update the information at any time without notice. December 2009 2

Contents 1 Description 4 2 Installing the Speed Control Capacitor 6 3 Installing the Fan Controller 7 3.1 DIN Rail Installation 7 3.2 Using the Optional Enclosure 8 4 Power and Fan Motor Wiring 9 5 C-Bus Connections 11 6 Controls and Indicators 12 6.1 Unit LED Indicator 12 6.2 C-Bus LED Indicator 12 6.3 Fan Speed LED Indicators 13 6.4 Local Override 'Manual' Pushbutton Switch (non-illuminated) 13 7 C-Bus Programming Requirements 14 8 Specifications 15 9 Dimensions 16 10 Standards Complied 17 11 Two-Year Warranty 18 3

1 Description The L5501RFCP C-Bus Ceiling Sweep Fan Controller unit is a DIN rail mounted C-Bus output device that provides speed control for a ceiling sweep fan. The Fan Controller uses multiple relays and a dual capacitor block for speed selection. The Fan Controller can be installed in the optional 5501FRE plastic enclosure on a wall or in a ceiling space. Catalogue Number Description L5501RFCP 5501FRE C-Bus output unit for controlling a ceiling sweep fan using capacitor control (DIN-rail version for switchboard installation) Enclosure to accommodate a C-Bus ceiling sweep fan controller output unit Table 1. Product catalogue numbers and descriptions The L5501RFCP Ceiling Sweep Fan Controller provides C-Bus control of a ceiling sweep fan for up to three speeds (Low, Medium and High) and Off. The unit uses double pole latching relays that switch both the active and neutral inputs. For the High speed, the active line and neutral are connected direct on-line (DOL) to the fan motor using the screw terminal connections (no capacitor in the circuit). The dual speed-control block capacitor (supplied with the fan by the ceiling fan manufacturer) can be conveniently located inside the Fan Controller body. You must open the hinged top cover to install the capacitor block in the well. Push-type connectors hold the capacitor wires in place. The Fan Controller is designed to withstand the high temperatures often found in spaces above ceilings. The unit is for indoor use only. A qualified person must install the electrical connections. The unit derives its power for programming and relay operation from the C-Bus network. The unit sinks 18 ma of current from the network and does not supply current to the network. The C-Bus network voltage can vary from 15V to 36V d.c. If the C-Bus network is disconnected or if the C-Bus voltage drops below 15V d.c. the fan speed will be set to Off. The unit does not derive power from the mains, nor does it require a mains connection to operate. 4

The Fan Controller has a non-illuminated local override 'Manual' pushbutton that has similar functions to other C-Bus output devices, including Learn mode. The local override button can override the output. Each press cycles the speed of the fan in the following order: Off Low Med Hi Off. Figure 1. C-Bus Ceiling Sweep Fan Controller features The unit has orange Unit and C-Bus LED indicators. In addition, there are orange indicators for each of the three selectable fan speeds. The fan speed indicators tell you the current speed selection (Low-Med-Hi). When no relay is energised, all of the fan speed indicators are off. There are two RJ45 connectors for C-Bus. The C-Bus Remote Override On and Off functions are not used in Fan Controller. For DIN rail mounting, use the standard 400 mm RJ45-RJ45 C-Bus network cable. A bootlace cable is provided for ceiling mounting inside the 5501FRE enclosure. The input power (A/L and N) and fan wires (SW Motor and SW N) are connected at a screw terminal block. Each of the connectors can accommodate two wires up to 1.5 mm² each. 5

Figure 2. C-Bus Ceiling Sweep Fan Controller terminal block connections 2 Installing the Speed Control Capacitor Only use the capacitor block that the fan manufacturer supplies for use with the fan motor. Do not substitute any other type or value. The capacitor must have an 85 C temperature rating that makes it suitable for use in ceiling spaces. Install the capacitor block inside the Fan Controller. The well provided for the block can handle a capacitor up to 45 mm long x 20 mm wide x 32 mm high. The push type capacitor terminals can accommodate one 1.5 mm² wire. 1. To install the capacitor block, open the hinged top cover. Be careful not to damage the plastic indicator or pushbutton parts that extend above the body of the Fan Controller. 2. Orient the capacitor block with the wires toward you in the order needed for connecting to the terminal block. 3. Starting nearest the centre of the unit, push the terminal button down, insert the wire and release the button. 4. After attaching all three wires, position the capacitor block and close the top cover. 6

3 Installing the Fan Controller You can install the Fan Controller on a DIN rail inside a power enclosure or you can use the optional custom enclosure, catalogue number 5501FRE. Install the Fan Controller indoors in a location free from moisture or direct sunlight. During installation, make sure that the top cover is closed. The plastic indicator parts and local override 'Manual' switch can be damaged when the top cover is open. 3.1 DIN Rail Installation The location of the Fan Controller on the DIN rail is not critical. To remove the Fan Controller from the DIN rail, use a small screwdriver to release the spring clip. Figure 3. Removing the Fan Controller from the DIN rail. 7

3.2 Using the Optional Enclosure The 5501FRE enclosure is recommended when the Fan Controller is installed on a wall or in a ceiling space. 1. In some locations it is advisable to cut or drill the holes for cable entry and exit before you permanently mount the back piece of the enclosure. 2. The enclosure can be mounted horizontally or vertically. Be sure to use mounting screws that are correct for the mounting surface, usually plasterboard or wood. 3. Keep the C-Bus network cables separate from the power input and fan wires. The C-Bus Cat.5e cabling enters from one end of the enclosure and the power and fan (load) wires enter from the opposite end. Note: Placing the fan controller inside the enclosure creates a physical barrier between the C-Bus and the mains/fan control areas of the enclosure. The unit can only be fitted inside the enclosure in the orientation shown in Figure 4. 4. Be sure to secure the cables at the anchor points to prevent accidental disconnection of the wires from the unit. Figure 4. The optional 5501FRE Fan Controller Enclosure 8

4 Power and Fan Motor Wiring A qualified electrician must connect building power and the fan motor to this device. Turn off the supply circuit before connecting the active line, neutral or fan motor wires. Requirements The supply circuit for the fan motor must be protected by a circuit breaker or fuse. Be sure to provide a separate earth (ground) wire for the fan motor body. The Fan Controller does not have an earthing terminal. Install the Fan Controller in an indoor location protected from moisture and direct sunlight. The Fan Controller relays are rated at 1.5A for an inductive load only. Do not exceed the rated value. The double pole relays in the Fan Controller switch the neutral as well as the active line. Do not use the fan motor output terminals as a connection point for any other device. The Fan Controller is compatible with copper and aluminium wire and solid conductor or stranded network cable. Keep the C-Bus network cabling segregated from the mains power and fan motor wiring in accordance with local wiring regulations. To avoid damage to the internal circuits, disconnect the fan load wiring from the Fan Controller unit before Megger testing the fan load wiring. Do not Megger test the C-Bus Cat.5e network cables. Provide strain relief for cables and seal the cable entry holes when using the optional enclosure. 9

Figure 5. Wiring connections for DIN rail mounted units Figure 6. Wiring connections in the optional enclosure C-Bus network wiring must be kept away from the input power and fan wires. When using the enclosure, the C-Bus Cat.5e cables must exit from one end of the enclosure and the power and fan connections must exit from the opposite end. 10

5 C-Bus Connections Two RJ45 connectors are provided for upstream and downstream network attachment. The C-Bus network uses pink Cat.5e, polarised 15-36 Volt, twisted-pair cables. Never connect the C-Bus interface to Ethernet or telephone equipment networks. Damage to equipment could result. RJ45 pin Signal name Wire Colour 1 Remote ON green & white 2 Remote ON green 3 C-Bus negative ( ) orange & white 4 C-Bus positive ( + ) blue 5 C-Bus negative ( ) blue & white 6 C-Bus positive ( + ) orange 7 Remote OFF brown & white 8 Remote OFF brown Note: The Remote On and Remote OFF features are not implemented on the Fan Controller. Table 2. C-Bus network wiring colour codes Figure 7. C-Bus network cable pin assignments 11

6 Controls and Indicators The indicator LEDs show unit status and fan speed. The non-illuminated Local Override 'Manual' pushbutton provides 'Local Toggle' and Learn Mode functions. 6.1 Unit LED Indicator The orange Unit indicator shows the status of the individual unit. When C-Bus is connected, the indicator stays illuminated. If the Local Override is active, the Unit indicator flashes with a 90% duty cycle. Indicator Mode Off On Flashing (90% duty cycle) Turning off of on alternately with C-Bus indicator Table 3. Unit indicator meanings 6.2 C-Bus LED Indicator Meaning Not connected to C-Bus C-Bus connected Local Override is active The Fan Controller is in Learn mode. The orange C-Bus indicator LED shows the status of the C-Bus network at the unit. If sufficient network voltage (20V d.c. to 36V d.c.) and a valid network clock are present, the indicator stays illuminated. If the network voltage is marginal, the indicator flashes. When the Fan Controller is operating in Learn Mode, the Unit and C-Bus LEDs alternately turn on and off. Off On Indicator Mode Flashing at a 4 Hz rate Turning off of on alternately with Unit indicator Table 4. C-Bus indicator meanings Meaning No network clock signal is present and/or no power is present. Power is on and C-Bus network clock is present. The C-Bus network power is marginal (15 V d.c. < voltage < 20 V d.c.) The Fan Controller is in Learn mode. 12

6.3 Fan Speed LED Indicators The Fan Controller activates the corresponding orange indicator when the output is set to Low, Medium or High. All fan speed indicators are off when the fan speed is set to Off. The local fan speed control sequence is Off-Low-Medium-High-Off. 6.4 Local Override 'Manual' Pushbutton Switch (non-illuminated) Local Toggle Mode Local Toggle Mode lets you cycle the fan through the speed control sequence locally. This feature is often used during testing and commissioning. The Local Toggle feature can be disabled using Toolkit software. If the Fan Controller is not already in Local Toggle mode and if the software allows the feature, a short press starts Local Toggle Mode with all relays Off. Subsequent button presses step the Fan Controller relays through the speed control sequence: Low-Med-Hi-Off, and so on. To exit Local Toggle Mode use a long press. The Fan Controller returns to normal C-Bus control. Learn Mode Learn mode is most often used to assign the Fan Controller to a lighting group. The Learn Mode feature can be disabled using Toolkit software. If the Fan Controller is not in Local Toggle Mode and if the software allows Learn Mode, a long press (10 seconds) starts Learn Mode. A subsequent long press exits Learn Mode. 13

7 C-Bus Programming Requirements Use C-Bus Toolkit software to configure the Ceiling Sweep Fan Controller. Using software not provided or approved by Clipsal could void the hardware warranty. The latest version of Toolkit software can be downloaded free of charge from http://www.clipsal.com/cis/portal, select Technical and then select Downloads. The Fan Controller unit integrates with C-Bus network group addresses etc. The Fan Controller has software-settable C-Bus network clock and burden. If C-Bus power is removed or if C-Bus voltage falls below 15V, the Fan Controller sets the output level to Off. Upon recovery from power failure, the Fan Controller sets the output speed to the last set level (default), or Off. The 'Restore to Off' function is user selectable. 14

8 Specifications Parameter C-Bus input voltage C-Bus current requirement Value Maximum units per network 100 Network clock 15-36 V d.c. 18 ma, powered from C-Bus network, does not provide power for the C-Bus network Software selectable Network burden Software selectable when Unit Address is 001 AC input impedance Warm-up time Electrical isolation Input voltage for fan motor Fan load rating Switch duty type (S1) 100 kω @ 1 khz 10 seconds 3.75 kv from C-Bus to mains 100 VAC to 240 VAC; input circuit must have a suitable circuit breaker 1.5 A Continuous duty. Line and neutral are switched. Fan motor and neutral are switched. Speed control Capacitive; capacitor block supplied by fan manufacturer for Low and Medium speeds. High speed uses direct on-line (no capacitor in the circuit). Three unique fan speeds Low, Med and Hi and Off. Connectors C-Bus: 2 x RJ-45 Capacitor block: 3 x push button for one 1.5 mm² Fan: 2 x screw type for one 1.5 mm² wire Input Power: 2 x screw type for up to two 1.5 mm² Indicators Unit, C-Bus, 3 x Fan speed Control Local override pushbutton, not illuminated Class of switch Class II Rated impulse withstand voltage 4 kv IP rating 20 Proof tracking index (PTI) 175 Pollution degree 2 Glow wire test (GWIT) Level 3, 850 C Mounting type DIN rail, or wall or ceiling space mounting in the optional plastic enclosure; For indoor use only Weight Fan Controller Relay Unit: 145 grams Optional plastic enclosure: 220 grams Operating temperature 0 to 65 C Humidity 10 to 95% RH, non condensing Note: The unit draws no power from mains and requires no mains connection to operate. 15

9 Dimensions Figure 8. L5501RFCP C-Bus Ceiling Sweep Fan Controller dimensions Figure 9. Optional 5501FRE Enclosure dimensions 16

10 Standards Complied Declarations of Conformity The L5501RFCP C-Bus Ceiling Sweep Fan Controller meets the following standards. Australian/New Zealand EMC & Electrical Safety Frameworks and Standards Regulation Standard Title EMC AS/NZ CISPR 14-1 Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emissions Safety AS/NZS 61058-1 Switches for appliances General Requirements European Directives and Standards European Council Directive EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC RoHS 2002/95/EC Standard EN 55014-1 EN55014-2 EN 61058-1 Title Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Emissions Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Immunity Product family standard Switches for appliances General Requirements Reduction of hazardous substances Other International Directives and Standards Regulation Standard Title EMC CISPR 14-1 CISPR 14-2 Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emissions Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Immunity Product family standard Safety IEC 61058-1 Switches for appliances General Requirements 17

11 Two-Year Warranty The L5501RFCP C-Bus Ceiling Sweep Fan Controller carries a two-year warranty against manufacturing defects. Warranty Statement The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Schneider Electric product, which the consumer has in the location where the product is sold. The warrantor is Schneider Electric with offices worldwide. This Schneider Electric product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. Schneider Electric reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. This warranty is expressly subject to the Schneider Electric product being installed, wired, tested, operated and used in accordance with the manufacturer's instructions. Any alterations or modifications made to the product without permission of Schneider Electric might void the warranty. Schneider Electric shall meet all costs of a claim. However, should the product that is the subject of the claim be found to be in good working order, all such costs shall be met by the claimant. When making a claim, the consumer shall forward the Schneider Electric product to the nearest Schneider Electric office. Provide adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. For all warranty enquiries, contact your local Clipsal sales representative. The address and contact number of your nearest sales office can be found at http://www.clipsal.com/locations or by telephoning Technical Support 1300 722 247 (CIS Technical Support Hotline). 18

This page is left blank for formatting purposes. 19

Technical Support For further assistance in using this product, consult your nearest Clipsal Integrated Systems (CIS) Sales Representative or Technical Support Officer. Technical Support Contact Numbers Australia New Zealand Northern Asia South Africa Southern Asia United Kingdom 1300 722 247 (CIS Technical Support Hotline) 0800 888 219 (CIS Technical Support Hotline) +852 2484 4157 (Clipsal Hong Kong) 011 314 5200 (C-Bus Technical Support) +603 7665 3555 Ext. 236 or 242 (CIS Malaysia) 0870 608 8 608 (Schneider Electric Support) Technical Support email: cis.support@clipsal.com.au Clipsal Australia Pty Ltd A member of Schneider Electric clipsal.com Contact us clipsal.com/feedback National Customer Care Enquiries: Tel 1 300 202 525 Fax 1 300 202 556 Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this document are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Copyright by Schneider Electric. All rights reserved. F2228 MS18540