AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Similar documents
Installation Manual BAK02

INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. programmable from PC

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2

Digital Keypad Introduction

Installing Keypad and Backplate

Showcasing the art of the video entry system.

INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. backlit touch keypad

DC Outdoor Power Supply/Chargers

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Operating instructions. Switching amplifier DN0210 DN / / 2015

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

TCNM-ACBB1 Installation Manual

INSTALLATION & OPERATING INSTRUCTIONS

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

CM-110SK Standalone Keypad Installation Instructions

2M IR Mini Dome Quick Installation Guide

1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H

User Manual. PCKeypad Wireless Keypad

CMSA-100 Manual. Cinema Media Server Automation

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

Switched Mode Power Supply Operating manual PAP800

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Operating Instructions VEGAMET 381

Operating instructions. Speed monitor D / / 2014

Display Panel BAT 100 LSN. en Operation Guide


Intelligent Security & Fire Ltd

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

AC5160 SiPass integrated controller kit

C5S120 Installation and Connection Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions Model PSC-17C

B&W RearView Camera Installation & Operation

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

INSTALLATION INSTRUCTIONS

Manual Control Unit GFC 32

ACTsmart2 Product Range Operating and Installation Instructions

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

9212i INSTALLATION. Stand-Alone Keypad. Instructions

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

02/11/2015

Expandable Power Systems

EM2020 Selectable AC transducer A (UK)

DC-D4213RX DC-D4213WRX

BC Digital Keypad. User Manual

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

* * Agilent Power Distribution Unit (PDU) Installation Guide

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Typ: CAS # GEV_1_fam_RZ_luensee_print.indd :53

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

IGLOO IGLOO EASY INSTRUCTION MANUAL

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

212iL Rev. 1.1

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Model HM-535 Power Supply Installation and Service Instructions

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Outdoor Motorized Dome. Quick Installation Guide 86085A

smartentry Wireless Video Doorphone User Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Magnetically Actuated Safety Interlock Switches

Single Door Standalone Access Control User Manual

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

BROADEN YOUR HORIZONS 7" display and advanced functions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

1. DB-9 interface pins Definition

Wireless Key fob, Key pad & Receiver Range

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Installation & Operation Guide

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

INSTALLATION MANUAL SLI 50 INVERTER

Manual Simatek Control Unit GFC 32

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Installation and Maintenance

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Operation and Maintenance Manual

Transcription:

TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013

AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA 2

Agata C200 UK AGATA C200 UK INSTALLATION Open the device by pressing on the lever at the bottom (fig. 1). Separate the shell from the bottom of the device. Secure the bottom of the device to the wall box using the screws provided (fig. 2 and 3). The box must be installed at an appropriate height for the user. Avoid tightening the screws too much. Once all connections have been made, reattach the shell to the bottom of the device (fig. 4). AGATA C200 UK 1 503 2 Ø60 3 4 Door lock release Auxiliary 2 w Only use soft, dry or slightly damp cloths to clean the terminal; do not use any chemical products. BP1 M1 Terminal boards 5 Ground 7 Call input from entry panel 8 Audio FROM entry panel 9 Audio TO entry panel BP1 In order to make the door open ( ) button active only when the reciever is up, cut the BP1 wire link. P1 Optional AGATA P1 auxiliary function ( ) switch housing. 5 7 8 9 Technical features M1 P1 Storage temperature -25 C +70 C Operating temperature +5 C +40 C IP Degree IP30 3

A/200 N 106 105 A B 43,5 7,5 57 45 A/200N INSTALLATION The power supplier must ALWAYS be installed horizontally. The device can be installed on a DIN rail (EN 50022) in an appropriate electric panel or it may be wall-mounted using the protective terminal covers. For disassembly, proceed as shown in figure 2-3-4. For the overall dimensions see figure 1. NOTE. Proper ventilation is required if the power supplier is installed in a metal container. 145 A/200 N 105 64,5 1 3 1 2 3 2 4 OPERATING CHARACTERISTICS The unit is equipped with a transformer capable of powering the HPC/1 entry panel and max. 20 HPP/6 panels. The unit features the following functions: - 2 two-tone call notes for entry panels (or for supplementary calls, e. g. landing calls). - Power supply and control of electric lock (12 V AC, 1 A) by means of relay (inside the unit) with timer-controlled interval adjustable from 2 to 15 seconds by means of potentiometer P1, figure 3. -Call generator: 2 types of two-tone call (up to 3 internal units can be connected in parallel to the same call). The unit can be powered from a 12 V DC power supply, e. g. battery or uninterruptable power supply (terminals +B and 5). The unit has no battery protection. C 5 8 9 +B 521 B 8 8A 11 12 23 16 NO CNC P1 B A~ Mains ~ +B 5 TERMINAL BOARDS 12 V DC input (*) Ground 21 11 V DC output 8 call common 1 output 8A call common 2 output 11 audio from entry panel 12 audio to entry panel 5 6 + output 14 V AC TECHNICAL FEATURES Supply voltage Rated power Output voltages Peak output voltages Operating output voltages Dimensions 230 VAC 50 60 Hz 34 VA 11 VDC, 150 ma 14 VAC, 650 ma 300 ma 1A 4 DIN Storage temperature -25 C +70 C Operating temperature 0 C +35 C IP Degree IP 30 NO C NC Normally open common normally closed relay contacts A C 5 ground 8 Audio to receiver 9 Audio from receiver (*) The appliance is electronically protected against overloads and short circuits. 4

ACCESSORIES TARGHA 200 Targha 200 Embedding box Surface housing Chassis Hole plugs HTS HBP Cable guide joints Spacer Cable guide joint Joint TARGHA 200 Screws Screws and anchors Button Buttons KHPS Micro-contact KHPD Micro-contacts Button spring Buttons spring Plate Micro-contacts with common call HPP/6 HPP/12D Lighting module Cable-clamp plates Hole plug 5

Targha 200 A RECESSED INSTALLATION The embedding box HTS must be fitted flush with the wall at an appropriate height. Fit the spacer into embedding boxes to avoid deformation (fig. 1). ATTENTION. To remove the microphone from its seat, pry it off its base using a small screwdriver (figure 2) taking care not to damage the cabling. From the back-box, before inserting the microphone, remove the part shown using pliers as illustrated in figure 3. Insert the audio module at the top, near to the top moulding of the chassis (fig. 4). In those installations liable to be affected by the Larsen effect, the microphone can be fitted in a remote position, is indicated in figure 4. Apply the micro-contact (bottom right) in the relevant seat (fig. 5). Remove the two plugs protecting the threaded holes in the embedding box and secure the chassis using the two screws supplied (fig. 6). Perform the wiring. Insert the access control module at the bottom and fasten it using the screw provided (fig. 7). TARGHA 200 1 2 WALL MOUNTING Apply the two hole plugs at the base (fig. 8). Fit the embedding box HBP (3-module or round Ø 65mm version) flush with the wall at an appropriate height. In the case of video entry panels, the height should be such as to exploit the features of the camera to the full. Fasten the base onto the wall using the screws and screw anchors supplied (fig. 9). ATTENTION. To remove the microphone from its seat, pry it off its base using a small screwdriver (figure 3) taking care not to damage the cabling. Insert the audio module at the top, near to the top moulding of the base (fig. 10). In those installations liable to be affected by the Larsen effect, the microphone can be fitted in a remote position, as indicated in figure 10. Apply the micro-contact (bottom right) in the relevant seat (fig. 11). Perform the wiring. Insert the access control module at the bottom and fasten it using the screw provided (fig. 12). 3 4 5 6 7 8 9 10 11 12 6

Targha 200 1 2 3 4 5 ASSEMBLY OF THE BUTTON Push the front plate from the front to release the hole plug (fig. 1) and subsequently remove it. Insert the button as illustrated in fig. 2 and 3. Apply the spring to the button (fig. 4). The name card can be removed and filled in with the relevant information by removing the card clip followed by the actual card itself (fig. 5). Personalized name cards can be used up to a maximum of 2 mm thick. TARGHA 200 CLOSURE OF THE COVER PLATE In order to fit the front plate, first insert the upper part in the top moulding and then, using a Allenkey s 2.5, tighten the lock screw (fig. 1-2). 1 2 A 1 2 3 4 5 6 SIDE-BY-SIDE RECESSED INSTALLATION For horizontal (fig. 1-2) or vertical (fig. 3-4) combinations, remove the hole plugs and insert the cable guide joints. Fit the spacer into embedding boxes to avoid deformation (fig. 2-4). SIDE-BY-SIDE WALL INSTALLATION For horizontal combinations, insert the two hole plugs on the outside, at the bottom inside the cable guide joint and top inside the joint (fig. 5). Fasten the bases to the wall using the screws and screw anchors supplied (fig. 6). 7

Targha 200 TERMINAL FUNCTION HA/200 5 21 8 11 12 14 Adjustments Loudspeaker audio Microphone audio TECHNICAL FEATURES Power supply 12 VDC Absorption 50 ma max (<35 stand-by) Storage temperature -25 C +70 C Operating temperature -15 C +50 C IP Degree IP 54 TERMINAL BOARDS 5 12 VDC 21 + Supply voltage 8 Common call (for witness note) 11 Audio to receiver 12 Audio from receiver 14 Enabling NOTE. In installations which do not cater for the enabling control, terminal 14 can be connected to the earth (module always on) or terminal 12 (module on only when receiver is lifted). HNA/102 TARGHA 200 SW1 M1 I1 A B C 1 2 3 4 5 6 7 8 9 0 NO NC C2 NO NC C1 M2 Function A (green) B (yellow) C (green) TECHNICAL FEATURES Power supply buttons for entering numerical codes and for programming button for activating an alarm or bell button for locking relays in active state three LEDs indicating status of module and functions in progress Approximate current demand with AC power supply Approximate current demand with DC power supply 12 16 VAC, 14 18 VDC max. 260 ma (120 ma stand-by) max. 180 ma (80 ma stand-by) Working temperature range -20 C +50 C M1 M2 TERMINAL BOARDS 12 to 16V AC, 14 to 18V DC module power supply I1 input ground C1 common NC normally closed NO normally open C2 common NC normally closed NO normally open external contact contacts relay 1 contacts relay 2 SW1 On: LEDs activated to light call buttons. Off: LEDs are disabled (default setting). HNA/102 OPERATING CHARACTERISTICS a) Up to 100 user codes can be stored. Codes can be 3, 4 or 5 digits long, with values in the range 001 to 65535. Each code can be associated with one of the 2 relays. b) The module features 2 relays for facilities with the following operating features: - programmable activation time for each relay (in the range 1 to 65 s); - monostable or bistable mode for each relay; - option of locking relays in active state in monostable mode by pressing key before the activation time is up (to disable, enter the code again); - option of associating relay 2 with an alarm or bell activation facility (function 09 must be enabled first). Activating the alarm: the relay 2 is activated by pressing key before entering your user code (see function 10 for disabling instructions). All user codes associated with relay 1 are enabled when the alarm is activated. Activating the bell: the relay 2 is activated by simply pressing key once. To prevent false alarms being sent, the option of associating usercodes with relay 2 is automatically inhibited. c) When a key is pressed, an audible signal is issued to confirm the various programming stages etc. as follows: - key pressed = short buzz; - correct operation = long buzz; - incorrect operation = three short buzzes. d) LEDs indicate the status of the module and functions in progress: - green LED A, suitably programmed, it can be: - an indicator associated with the audible signal, - disabled, - controlled by input I1. - yellow LED B, pulse = confirms facilities activated. - green LED C, always lit = in service, flashing = in programming mode. The LED lights 1 min after the unit has been powered (during which time, the unit can be reset). e) The keypad can be disabled indefinitely by entering a specific code, e.g. when you are away for some time (see FUNCTION 12). f) The keypad is locked out for a programmable time if, after entering 20 digits, no valid code has been entered (see FUNCTION 07). g) There is an input I1 for electric contact, which can be programmed to give it different functions: activates relay 1, enables tradesman mode, or controls green LED A (see FUNCTION 11). h) Tradesman mode: via this function, you can enable relay 1 only when contact I1 is closed to earth (with external timer) and only for user codes associated with facility 3 (see FUNCTION 03). i) Default settings can be restored using the RESET function (see resetting procedure). Stored user codes and the number of digits programmed are kept in the memory. THE HNA/102 MODULE S DEFAULT FACTORY SETTINGS PROGRAMMING CODE: 1234 (5 digits). RESET CODE: 102 not programmable; USER CODE on relay 1: 2580. USER CODE on relay 2: 3690. ACTIVATION TIME for relays activating facilities: 5 s. ACTIVATION MODE for relays activating facilities: monostable. NUMBER OF DIGITS for user codes: 4. Keypad LOCKOUT TIME: 10 s. BELL: disabled. BELL TIME: 3 s. ALARM: disabled. KEYPAD: enabled. INPUT FOR CONTACT I1: controlled by relay 1. GREEN LED A: disabled. 8

Targha 200 PROGRAMMING 1 01 3 2 4 12345 or Entering and exiting programming To enter programming mode, press keys 1 and 3 at the same time 1 and then enter the PROGRAMMING CODE (green LED C flashes) 2. Enter the FUNCTION CODE to select the type of function 3. Once entered the required data, it is possible select another type of function, exit any function selected by pressing or 4 other then exit programming mode by keying in (in this case, green LED C stops flashing) 5. Once the data required by the function have been entered, there is a long buzz if the operation is correct, or three short buzzes if it is incorrect 6. + ok beeeep ko bep bep bep 5 FUNCTION 01 Editing the programming code (default setting 12345) 2- Enter the new PROGRAMMING CODE (5 digits). FUNCTION 02 Editing the number of digits in the user code (default setting 4) (all user codes have the same number of digits) 2- Enter the NUMBER OF DIGITS (3 digits code, or 4 or 5 digits code). FUNCTION 03 Adding a user code (default setting relay 1=2580, relay 2=3690) 2- Enter the number of the FACILITY to be programmed: 1 = activates relay 1, 2 = activates relay 2, 3 = activates relay 1 in tradesman mode (see FUN- CTION 11). 3- Enter the USER CODE. 4- Repeat the procedure from point 2) to enter another user code, select another function. 6 FUNCTION 08 Setting monostable or bistable mode for relays (default setting monostable) 2- Enter the FACILITY/RELAY you want (1 or 2 or 3). 1 = activates relay 1, 2 = activates relay 2, 3 = activates relay 1 in tradesman mode. 3- Enter ACTIVATION MODE = BISTABLE, 1 = MONOSTABLE. 3- Repeat the procedure from point 2) to set another relay, select another function. FUNCTION 09 Enabling/disabling the alarm and bell (default setting both disabled) 2- Enter the mode: = BOTH DISABLED, 1 = ALARM ENABLED, 2 = BELL ENABLED. NOTE. Enabling the alarm or bell disables relay 2 s settings. FUNCTION 10 Alarm reset 1- Enter FUNCTION CODE 10. FUNCTION 13 Programming green A 1- Enter FUNCTION CODE 13. 2- Enter: = DISABLED, 1 = LIGHTS WHENEVER A BUTTON IS PRESSED. Note. Programming is not enabled if the LED is already associated with input I1 (see function 11). Module resetting procedure To reset the module: 1 - Cut off power to the unit. 2 - Restore power to the unit (green LED C is unlit) and enter the RESET CODE within 1 min of the unit being switched on. Note. Stored user codes and the number of digits programmed are kept in the memory. TARGHA 200 FUNCTION 04 Deleting a user code 2- Enter the USER CODE to be deleted. FUNCTION 05 Deleting all user codes 2- Enter (USERS DELETION CODE). FUNCTION 06 Setting relay activation time for activating facilities (default setting 5 s) 2- Select the RELAY you want by entering 1 or. 3- Enter ACTIVATION TIME in the range 01 to 65 s. 4- Repeat the procedure from point 2) to set the other relay s activation time or select another function. FUNCTION 11 Programming input I1 (default setting controls relay 1) 1- Enter FUNCTION CODE 11. 2- Enter: = controls relay 1, 1 = enables tradesman mode (see functions on pag. 3, point h), 2 = controls green LED A, 3 = disabled. FUNCTION 12 Enabling/disabling the keypad (default setting enabled) 1- Enter FUNCTION CODE 12. 2- Enter: = DISABLED, 1 = ENABLED. FUNCTION 07 Setting keypad lockout time (default setting 10 s) 2- Enter LOCKOUT TIME in the range 01 to 65 s. 9

DISPOSAL Do not litter the environment with packing material: make sure it is disposed of according to the regulations in force in the country where the product is used. When the equipment reaches the end of its life cycle, take measures to ensure it is not discarded in the environment. The equipment must be disposed of in compliance with the regulations in force, recycling its component parts wherever possible. Components that qualify as recyclable waste feature the relevant symbol and the material s abbreviation. 10

11

BPT S.p.A. a Socio Unico Via Cornia, 1 33079 Sesto al Reghena-PN-Italy www.bpt.it-info@bpt.it 12