Heavy Duty Datalogging Light Meter

Similar documents
Heavy Duty Datalogging Light Meter

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

User's Guide. Datalogging Light Meter with PC Interface. Model

User Guide. Moisture Meter. Model MO250

True RMS AC Voltage/Current Datalogger

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Model Laser Photo Tachometer

Heavy Duty Datalogger Module

SuperHeat Psychrometer Models RH350 and RH355 (kit)

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

Heavy Duty Vibration Meter

Mini Photo Tachometer Model Mini Contact Tachometer Model

Heavy Duty Mini Vane CFM Thermo Anemometer

Heavy Duty Datalogger Module

Heavy Duty Psychrometer + IR Thermometer Model HD500

User's Guide. Video Borescope. Model BR100

User s Guide. 600A AC Clamp Meter. Model 38387

User s Manual. Model and Sound Level Calibrators

3-Axis G-Force Datalogger

Digital Vane Thermo-Anemometer Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Digital Sound Level Meter. Model

User's Guide. Hot Wire Thermo-Anemometer Model

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

User's Manual Sound Level Alert Model SL130

User's Guide. Heavy Duty Differential Pressure Manometer. Model

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User's Guide Video Borescope Model BR200

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Laser Photo/ Contact Tachometer. m/min. ft/min

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Integrating Sound Level Datalogger Model

User's Guide. Temperature / Humidity Datalogger. Model 42270

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Guide. Model High Precision Quad Output DC Power Supply

Digital Sound Level Meter

Hygro Thermo-Anemometer Model

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

User's Manual. Digital Sound Level Meter. Model

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User Guide. ExStik FL700. Fluoride Meter

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

Dual Input, 3-Display Thermometer/Datalogger Model

User's Guide. Mini Microscope. Model MC108

Power Analyzer Datalogger Model

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

Mini Digital Multimeter

Light Meter SD Card real-time datalogger

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

Light Meter with Bar Graph

User Manual. Thermocouple Datalogging Thermometer. Model EA15

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

User's Guide. EasyView K-Type Thermometer. Model EA11A

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Vibration Meter SD Card real-time datalogger

4-Channel Thermometer / Datalogger

Light Meter (Foot Candles)

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

Heavy Duty Hot Wire CFM Thermo-Anemometer

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Personal Sound Level Meter

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Indoor Air Quality Meter/Datalogger

Heavy Duty Vibration Meter

Hygro-Thermometer / Datalogger

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

12-Channel Thermocouple Datalogger

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Sound Level Meter SD Card real-time Datalogger

INSTRUCTION MANUAL. Models: H100 Light Meter

ph/orp Meter SD Card real-time Datalogger

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Dual Moisture Meter Pin / Pinless Moisture Meter

Autoranging Mini Multimeter Model MN16A

4-Channel Vibration Datalogger

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Visible Light SD Card Datalogger

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Transcription:

User's Guide Heavy Duty Datalogging Light Meter with PC Interface Model HD450

Introduction Congratulations on your purchase of the Extech HD450 Digital Light Meter. The HD450 measures illuminance in Lux and Foot candles (Fc). The HD450 is a Datalogger and includes a PC interface and Windows TM compatible software for downloading data. Up to 16,000 readings can be stored on the meter for download to a pc and 99 readings can be stored and viewed directly on the meter s LCD display.. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Meter Description Meter Description 1. Sensor cable plug 2. USB jack for PC interface (under the flip-down cover) 3. LCD Display 4. Upper function button set 1 2 3 5. Lower function button set 6. Power ON-OFF button 4 7. Light sensor NOTE: The battery compartment, tripod mount, and tilt stand are located on the rear of the instrument and are not pictured Display Description 5 6 7 1. Clock setting modes 2. Clock display 16 15 3. Relative mode icon 4. Auto Power OFF (APO) icon 5. Low battery icon 1 2 14 13 12 6. Data Hold icon 7. PEAK HOLD modes 11 8. Range indicators 9. Unit of measure 10 10. Digital display 11. Bargraph display 12. Data download to PC icon 3 4 9 13. PC serial connection established 14. Memory address number 5 6 7 8 15. USB PC connection icon 16. Memory icon 2

Operation Meter Power 1. Press the Power button to turn the meter ON or OFF 2. If the meter does not switch on when the power button is pressed or if the low battery icon is displayed on the LCD, replace the battery. Auto Power Off (APO) 1. The meter is equipped with an automatic power off (APO) feature that turns the meter off after 20 minutes of inactivity. The icon appears while APO is enabled. 2. To disable the APO feature, simultaneously press and release the RANGE/APO and REC/SETUP buttons. Press and release again to re-activate the APO feature. Unit of Measure Press the UNITS button to change the unit of measure from Lux to Fc or from Fc to Lux Range Selection Press the RANGE button to select the measurement range. There are four (range) selections for each unit of measure. The range icons will appear to identify the range selected. Taking a Measurement 1. Remove the sensor s protective cap to expose the white sensor dome 2. Place the sensor in a horizontal position under the source of light to be measured 3. Read the light level on the LCD display (numerically or with the bargraph). 4. The meter will display OL when the measurement is outside of the meter s specified range or if the meter is set to the wrong range. Change the range by pressing the RANGE button to find the best range for the application. 5. Replace the protective sensor cap when the meter is not in use. Data Hold To freeze the LCD display, momentarily press the HOLD button. 'MANU HOLD' will appear on the LCD. Momentarily press the HOLD button again to return to normal operation. Peak Hold The Peak Hold function allows the meter to capture short duration light flashes. The meter can capture peaks down to 10µS in duration. 1. Press the PEAK button to activate the Peak Hold feature. Manu and Pmax will appear on the display. Press the PEAK button again and Manu and Pmin will appear. Use Pmax to capture positive peaks. Use Pmin to capture negative peaks. 2. When the peak has been captured, the value and associated time will remain in the display until a higher peak is recorded. The bargraph display will remain active displaying the current light level. 3. To exit the Peak Hold mode and return to the normal operating mode, press the PEAK button a third time. 3

Maximum (MAX) and Minimum (MIN) Reading Memory The MAX-MIN function allows the meter to store the highest (MAX) and lowest (MIN) readings. 1. Press the MAX-MIN button to activate the feature. Manu and MAX will appear on the display and the meter will only display the highest reading encountered. 2. Press the MAX-MIN button again. Manu and MIN will appear on the display and the meter will only display the lowest reading encountered. 3. When the MAX or MIN has been captured, the value and associated time will remain in the display until a higher value is recorded. The bargraph display will remain active displaying the current light level. 4. To exit this mode and return to the normal operating mode, press the MAX-MIN button a third time. Relative Mode The Relative Mode function allows the user to store a reference value in the meter. All displayed readings will be relative to the stored reading. 1. Take the measurement, and when the desired reference value is displayed, press the REL button. 2. Manu will appear on the LCD display. 3. All subsequent readings will be offset by the by an amount equal to the reference level. For example, if the reference level is 100 Lux, all subsequent readings will equal the actual reading minus 100 Lux. 4. To exit the Relative Mode, press the REL button. LCD Backlight The meter is equipped with a backlight feature that lights up the LCD display. 1. Press the backlight button to activate the backlight. 2. Press the backlight button again to switch the backlight off. Note that the backlight will turn off automatically after a short period of time in order to save battery energy. 3. The backlight function uses extra battery energy. To conserve energy, use the backlight feature sparingly. 4

Clock and Sample Rate Setup In this mode, the and arrow buttons will allow adjustment of the selected (flashing) digits. The and buttons will scroll to the next or previous selection. 1. Power the meter, then press and the REC/SETUP and UNITS buttons simultaneously to enter the Setup mode. The hours display will flash. 2. Adjust and step through each selection as needed. 3. Press and hold the REC/SETUP and UNITS buttons simultaneously to exit the Setup mode. The order of selection with the flashing (icon) is: Hour (0 to 23) 12:13:14 (Time) Minute (0 to 59) 12:13:14 (Time) Second (1 to???) 12:13:14 (Time) Sample Rate (00 to 99 seconds) 02 (Sampling) Month (1 to 12) 1 03 10 (Day) Day (1 to 31) 1 03 10 (Day) Day of the week (1 to 7 1 03 10 (Day) Year (00 to 99) 2008 (Year) 99 Point Memory Up to 99 readings can be stored manually for later viewing directly on the meter s LCD. This data can also be transferred to a PC using the supplied software program. 1. With the meter ON, press the REC button momentarily to store a reading 2. The MEM display icon will appear with the memory address number (01-99) 3. If the 99-reading memory is full, the MEM icon and memory location number will not appear 4. To view stored readings, press and hold the LOAD button until the MEM display icon appears alongside the memory address number. 5. Use the up and down arrow buttons to scroll through the stored readings. 6. To clear the data, press and hold the REC/SETUP and LOAD buttons simultaneously until CL appears in the memory location field on the LCD 16,000 Point Datalogger The HD450 can automatically record up to 16,000 readings in its internal memory. To view the data, the readings must be transferred to a PC via the supplied software. 1. Using the SETUP mode, set the time and sample rate. The default sample rate is 1 sec. 2. To begin recording, Press and Hold the REC button until the MEM display icon begins blinking. Data will store at the sample rate while the MEM icon is blinking. 3. To stop recording. Press and Hold the REC button until the MEM icon disappears. 4. If the memory is full, OL will appears as the memory number. 5. To clear the memory, with the meter off, press and hold the REC button and then press the power button. del will appear in the display. Release the REC button when MEM appears in the display, the memory has been cleared. 5

USB PC Interface Description The HD450 meter can be connected to a PC via its USB interface. A USB cable, along with Windows TM software, is included with the meter. The software allows the user to: Transfer previously stored readings from the meter s internal memory to a PC View, plot, analyze, store, and print readings data Remotely control the meter via virtual software buttons Record readings as they are taken. Subsequently, printing, storing, analyzing, etc. the readings data Meter to PC Connection The supplied USB cable is used to connect the meter to a PC. Connect the smaller connector end of the cable to the meter s interface port (located under the tab at the lefthand side of the meter). The larger connector end of the cable connects to a PC USB port. Program Software The supplied software allows the user to view readings in real-time on a PC. The readings can be analyzed, zoomed, stored, and printed. Please refer to the HELP UTILITY available from inside the software program for detailed software instructions. The main software screen is shown below for preview. 6

Specifications Range Specifications Units Range Resolution Accuracy Lux 400.0 0.1 4000 1 ± (5% rdg + 10 digits) 40.00k 0.01k 400.0k 0.1k ± (10% rdg + 10 digits) Foot candles 40.00 0.01 400.0 0.1 ± (5% rdg + 10 digits) 4000 1 40.00k 0.01k ± (10% rdg + 10 digits) Notes: 1. Sensor Calibrated to standard incandescent lamp (color temperature: 2856K) 2. 1Fc = 10.76 Lux General Specifications Display 4000 count LCD display with 40 segment bargraph Ranging Four ranges, manual selection Over range indication LCD displays OL Spectral response CIE photopic (CIE human eye response curve) Spectral accuracy Vλ function (f 1 6%) Cosine response f 2 2%; Cosine corrected for angular incidence of light Measurement Repeatability ±3% Display rate Approximately 750 msec for digital and bargraph displays Photo detector Silicon photo-diode with spectral response filter Operating conditions Temperature: 32 to 104 o F (0 to 40 o C); Humidity: < 80%RH Storage conditions Temperature: 14 to 140 o F (-10 to 50 o C); Humidity: < 80%RH Meter Dimensions 6.7 x 3.2 x 1.6" (170 x 80 x 40mm) Detector Dimensions 4.5 x 2.4 x 0.8 (115 x 60 x 20mm) Weight Approx. 13.8 oz. (390g) with battery Sensor lead length 3.2 (1m) Low battery indication Battery symbol appears on the LCD Power supply 9V battery Battery Life 100hrs (backlight off) 7

Maintenance Cleaning The Meter and its sensor can be cleaned with a damp cloth. A mild detergent may be used but avoid solvents, abrasives, and harsh chemicals. Battery Installation / Replacement The battery compartment is located on the back of the meter. The compartment is easily accessed by pressing and sliding the rear battery compartment cover off of the meter in the direction of the arrow. Replace or install the 9V battery and close the battery compartment by sliding the compartment cover back onto the meter. Storing When the meter is to be stored for a period of time, please remove the battery and affix the sensor s protective cover. Avoid storing the meter in areas of extreme temperature and humidity. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Care Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three (3) years from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Support line (781) 890-7440 Technical Support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 Copyright 2008 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 8