USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Similar documents
Heavy Duty Datalogging Light Meter

Heavy Duty Datalogging Light Meter

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Light Meter SD Card real-time datalogger

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Dual Moisture Meter Pin / Pinless Moisture Meter

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

User's Guide. EasyView K-Type Thermometer. Model EA11A

Vibration Meter SD Card real-time datalogger

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User Manual. Thermocouple Datalogging Thermometer. Model EA15

4-Channel Thermometer / Datalogger

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Personal Sound Level Meter

Hygro-Thermometer / Datalogger

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Digital Sound Level Meter

Model A Mini AC/DC Clamp Meter. User's Guide

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

ph/orp Meter SD Card real-time Datalogger

USER GUIDE. AC/DC Magnetic Meter. Model MF100

4-Channel Vibration Datalogger

User's Guide. Datalogging Light Meter with PC Interface. Model

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Model A Current / Voltage Calibrator. User's Guide

User Guide. Moisture Meter. Model MO250

Sound Level Meter SD Card real-time Datalogger

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Vibration Meter and Laser Combination Tachometer

12-Channel Thermocouple Datalogger

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

User's Guide. Hot Wire Thermo-Anemometer. Model

User's Guide. Datalogging Hygro-Thermometer Model SD500

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Heavy Duty Vibration Meter

Model A Current Calibrator. User Guide

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Indoor Air Quality Meter/Datalogger

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

Light Meter with Bar Graph

User's Guide. 3 Channel Datalogging Thermometer Model SD200

Humidity & Temperature Datalogger

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

User Guide. Video Borescope. Models BR200 and BR250

Datalogging Hygro-Thermometer

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

USER GUIDE Turbidity Meter Model TB400

USER GUIDE Current Calibrator

SuperHeat Psychrometer Models RH350 and RH355 (kit)

Datalogging Hygro-Thermometer

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

Barometric Pressure / Humidity and Temperature Datalogger

3 Channel Datalogging Thermometer

11 in 1 Environmental Meter

Large Vane CFM/CMM Thermo-Anemometer

Humidity + Temperature + Pressure Datalogger

Large Vane CFM/CMM Anemometer / Psychrometer

User's Guide. Digital Multimeter. Model MN42

User's Guide. Video Borescope. Models BR200 and BR250

Coating Thickness Tester

Fruit Hardness Tester

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

Video Borescope Inspection Camera

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

Formaldehyde Thermo-Hygrometer

Digital Sound Level Meter MODEL

Heavy Duty Hot Wire CFM Thermo-Anemometer

User Guide True RMS Multimeter Extech EX205T

USER GUIDE. Coating Thickness Tester. Model CG104

Thermocouple Calibrator

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

ET130 ENGLISH. INSTRUCTION MANUAL Light Meter MEASUREMENTS IN FOOT CANDLES (FC) AND LUX DATA HOLD MAX/MIN BACKLIT LCD SCREEN

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Light Meter (Foot Candles)

LM-100 LM-120 Light Meters Users Manual

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

LIGHT METER OPERATION MANUAL. Model : LM-81LX

Humidity & Temperature Datalogger

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

User's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50

Heavy Duty Psychrometer + IR Thermometer Model HD500

Wireless TRMS Multimeter and Insulation Tester

ENGLISH. User manual

True RMS Industrial Multimeter Extech EX520

Extech EX845 True RMS 1000 Amp Clamp Meter with Bluetooth

Integrating Sound Level Datalogger Model

True RMS Multimeter with IR Thermometer

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

Transcription:

USER GUIDE Heavy Duty Digital Light Meter with PC Interface Model HD400

Introduction Congratulations on your purchase of the Extech HD400 Digital Light Meter. The HD400 measures illuminance in Lux and Foot candles (Fc). The HD400 includes a PC interface and Windows TM compatible software for real-time monitoring and storage of light level data. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features Precision instrumentation for the measurement of light illuminance Large, 4000 count, backlit LCD display with fast 40 segment bargraph Data Hold function Meets CIE Photopic spectral response Fully cosine corrected for angular incidence of light Stable, long-lasting silicon photo diode sensor with spectral response filter Fast responding High accuracy Automatic zero function Peak Hold function for capturing fast changes in light levels down to 10mS Auto power off after 20 minutes of inactivity Maximum and Minimum light level memory Relative reading feature USB PC Interface for Data acquisition Four (4) range levels Heavy Duty, rugged, double molded housing 2

Description Meter Description 1. Sensor cable plug shown connected to meter jack 2. USB jack for PC interface (under the flip-down cover) 3. LCD Display 4. Upper Push Button set 5. Lower Push Button set 6. Sensor s light collector dome 7. Sensor housing (protective cover not shown) 8. Power ON-OFF button NOTE: The battery compartment, tripod mount, and tilt stand are located on the rear of the instrument and are not pictured 1 2 3 4 5 8 6 7 Display Description 1. Digital measurement reading 2. Bargraph measurement reading 4 5 6 7 8 3. Auto Power OFF active icon 4. MANU icon 5. DATA HOLD icon 6. RELATIVE mode icon 7. MAXIMUM and MINIMUM reading mode 8. PEAK HOLD mode 3 2 1 9. Low Battery symbol 10. PC connection icon 11. Range units of measure 9 10 11 3

Operation Meter Power 1. Press the Power button to turn the meter ON or OFF 2. If the meter does not switch on when the power button is pressed or if the low battery icon is displayed on the LCD, replace the 9V battery Auto Power Off (APO) 1. The meter is equipped with an automatic power off (APO) feature that turns the meter off after 20 minutes of inactivity 2. To defeat the APO feature, press and hold the APO button. While holding down the APO button, press the RANGE button to switch off the circular APO symbol on the upper left-hand corner of the LCD. Repeat this step to re-activate the APO feature. The APO icon will reappear. Unit of Measure Press the UNITS button to change the unit of measure from Lux to Fc or from Fc to Lux Range Selection Press the RANGE button to select the measurement range. There are four (range) selections for each unit of measure. The units display and decimal point location identify the range selected. Refer to the Range Specifications section of this User Guide for detailed range information. Taking a Measurement 1. Remove the sensor s protective cap to expose the white sensor dome 2. Place the sensor in a horizontal position under the source of light to be measured 3. Read the illuminance measurement on the LCD display. 4. The meter will display OL when the measurement is outside of the meter s specified range or if the meter is set to the wrong range. Change the range by pressing the RANGE button. 5. Replace the protective sensor cap when the meter is not in use. Data Hold To freeze the LCD display, momentarily press the HOLD button. 'MANU HOLD' will appear on the upper left-hand side of the LCD. Momentarily press the HOLD button again to return to normal operation ('MANU HOLD' will switch off). Peak Hold The Peak Hold function allows the meter to capture short duration light flashes. The meter can capture peaks down to 10mS in duration. 1. Press the PEAK button to activate the Peak Hold feature. MANU Pmax will appear on the display. Press the PEAK button again and MANU Pmin will appear. Use Pmax to capture positive peaks. Use Pmin to capture negative peaks. 2. To exit the Peak Hold mode and return to the normal operating mode, press the PEAK button a third time. 4

Maximum (MAX) and Minimum (MIN) Reading Memory The MAX-MIN function allows the meter to store the highest (MAX) and lowest (MIN) readings. 1. Press the MAX-MIN button to activate the feature. MANU MAX will appear on the top of the display and the meter will only display the highest reading encountered. 2. Press the MAX-MIN button again. MANU MIN will appear on the top of the display and the meter will only display the lowest reading encountered. 3. To exit this mode and return to the normal operating mode, press the MAX-MIN button a third time. Relative Mode The Relative Mode function allows the user to store a reference value in the meter for which to compare subsequent readings. For example, if the user stores a reading of 100 Lux, all subsequent readings will be displayed as actual reading minus 100. 1. Take the measurement, and when the desired reference value is displayed, press the REL button. 2. MANU REL will appear at the top of the LCD display. 3. All subsequent readings will be offset by an amount equal to the reference level. For example, if the reference level is 100 Lux, all subsequent readings will equal the actual reading plus 100 Lux. 4. To exit the Relative Mode, press the REL button. MANU REL will switch off indicating that the meter has returned to the normal operating mode. LCD Backlight The meter is equipped with a backlight feature that lights up the LCD display. 1. Press the backlight button to activate the backlight 2. Press the backlight button again to switch the backlight off. Note that the backlight will turn off automatically after a short period of time in order to save battery energy. 3. The backlight function uses extra battery energy. To conserve energy, use the backlight feature sparingly. 5

USB PC Interface Description The HD400 meter can be connected to a PC via its USB interface. A USB cable, along with Windows TM software, is included with the meter. The software allows the user to view, store, and print readings from the PC. Note that the HD400 does not datalog readings, meaning that it does not store readings in an internal memory; it simply displays readings on the PC as they are taken in real-time; after which the readings can be analyzed, stored as text, or printed. Meter to PC Connection The supplied USB cable is used to connect the meter to a PC. Connect the smaller connector end of the cable to the meter s interface port (located under the tab at the left-hand side of the meter). The larger connector end of the cable connects to a PC USB port. Program Software The supplied software allows the user to view readings in real-time on a PC. The readings can be analyzed, zoomed, stored, and printed. Please refer to the HELP UTILITY available from inside the software program for detailed software instructions 6

Specifications Range Specifications Units Range Resolution Accuracy Lux 400.0 0.1 4000 1 ± (5% rdg + 10 digits) 40.00k 0.01k 400.0k 0.1k ± (10% rdg + 10 digits) Foot candles 40.00 0.01 400.0 0.1 ± (5% rdg + 10 digits) 4000 1 40.00k 0.01k ± (10% rdg + 10 digits) Notes: 1. Sensor Calibrated to standard incandescent lamp (color temperature: 2856K) 2. 1Fc = 10.76 Lux General Specifications Display 4000 count LCD display with 40 segment bargraph Ranging Four ranges, manual selection Over range indication LCD displays OL Spectral response CIE photopic Spectral accuracy Vλ function (f 1 6%) Cosine response f 2 2%; Cosine corrected for angular incidence of light Measurement Repeatability ±3% Display rate Approximately 750 msec for digital and bargraph displays Photo detector Silicon photo-diode with spectral response filter Peak capture 10mS minimum Operating conditions Temperature: 0 to 40 o C (32 to 104 o F); Humidity: < 80%RH Storage conditions Temperature: -10 to 50 o C (14 to 140 o F); Humidity: < 80%RH Meter Dimensions 170 x 80 x 40mm (6.7 x 3.1 x 1.6") Detector Dimensions 115 x 60 x 20mm (4.5 x 2.4 x 0.8 ) Weight Approx. 390g (13.7 oz.) with battery Sensor lead length 1m (3.2 ) Low battery indication Battery symbol appears on the LCD Power supply 9V battery 7

Maintenance Cleaning The meter and its sensor can be cleaned with a damp cloth. A mild detergent may be used but avoid solvents, abrasives, and harsh chemicals. Battery Installation / Replacement The battery compartment is located on the back of the meter. The compartment is easily accessed by pressing and sliding the rear battery compartment cover off of the meter in the direction of the molded arrow. Replace or install the 9V battery and close the battery compartment by sliding the compartment cover back onto the meter. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Storing When the meter is to be stored, please remove the battery and affix the sensor s protective cover. Avoid storing the meter in areas of extreme temperature and humidity. Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 8