Using the ThinkServer SA120 Disk Array

Similar documents
Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

Lenovo SAN Manager - Provisioning and Mapping Volumes

Lenovo Database Configuration Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ECONOMICAL, STORAGE PURPOSE-BUILT FOR THE EMERGING DATA CENTERS. By George Crump

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Lenovo RAID Introduction Reference Information

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

IBM System Storage DS5020 Express

Lenovo Validated Designs

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

IBM System Storage DCS3700

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs

HPE MSA 2042 Storage. Data sheet

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

Reduce costs and enhance user access with Lenovo Client Virtualization solutions

Lenovo Database Configuration

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

powered by Cloudian and Veritas

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

2013 LENOVO. ALL RIGHTS RESERVED.

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

IBM System Storage DS6800

Hitachi Adaptable Modular Storage and Workgroup Modular Storage

EMC Integrated Infrastructure for VMware. Business Continuity

System x Server for SAP Business One, version for SAP HANA

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

Lenovo RDX USB 3.0 Disk Backup Solution Product Guide

UCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale

Hitachi Adaptable Modular Storage and Hitachi Workgroup Modular Storage

Reference Architecture Microsoft Exchange 2013 on Dell PowerEdge R730xd 2500 Mailboxes

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

All-Flash Storage Solution for SAP HANA:

EMC Backup and Recovery for Microsoft Exchange 2007

Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000

HPE ProLiant ML110 Gen10 Server

Lenovo Software Defined Storage with Windows Server 2016 Datacenter Storage Spaces

Entry-level Intel RAID RS3 Controller Family

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

DS8880 High Performance Flash Enclosure Gen2

Lenovo Database Configuration for Microsoft SQL Server TB

EMC XTREMCACHE ACCELERATES ORACLE

An Oracle Technical White Paper October Sizing Guide for Single Click Configurations of Oracle s MySQL on Sun Fire x86 Servers

SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES

LENOVO THINKSERVER OPTIONS AND UPGRADES

EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance

HPE ProLiant ML110 Gen P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P )

EMC Backup and Recovery for Microsoft SQL Server

IBM System Storage DS4800

ServeRAID H1110 SAS/SATA Controller Product Guide

IBM System Storage EXP3500 Express

Thinking Different: Simple, Efficient, Affordable, Unified Storage

DS8880 High-Performance Flash Enclosure Gen2

Assessing performance in HP LeftHand SANs

Data Protection for Cisco HyperFlex with Veeam Availability Suite. Solution Overview Cisco Public

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

Exchange 2010 Tested Solutions: 500 Mailboxes in a Single Site Running Hyper-V on Dell Servers

IBM System Storage DS5020 Express

Accelerating Enterprise Search with Fusion iomemory PCIe Application Accelerators

Isilon Scale Out NAS. Morten Petersen, Senior Systems Engineer, Isilon Division

Dell EMC SC Series SC5020 9,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K Drives

THE SUMMARY. CLUSTER SERIES - pg. 3. ULTRA SERIES - pg. 5. EXTREME SERIES - pg. 9

Fusion iomemory PCIe Solutions from SanDisk and Sqrll make Accumulo Hypersonic

Dell EMC SCv3020 7,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K drives

Create a Flexible, Scalable High-Performance Storage Cluster with WekaIO Matrix

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide

New Approach to Unstructured Data

HCI: Hyper-Converged Infrastructure

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide

PRESERVE DATABASE PERFORMANCE WHEN RUNNING MIXED WORKLOADS

ServeRAID C100 and C105 Product Guide

Virtual Security Server

HP P6000 Enterprise Virtual Array

Mostafa Magdy Senior Technology Consultant Saudi Arabia. Copyright 2011 EMC Corporation. All rights reserved.

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Moving From Reactive to Proactive Storage Management with an On-demand Cloud Solution

Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide

Dell EMC Microsoft Exchange 2016 Solution

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

TECHNICAL OVERVIEW OF NEW AND IMPROVED FEATURES OF EMC ISILON ONEFS 7.1.1

The Microsoft Large Mailbox Vision

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

Lenovo Enterprise Capacity Solid State Drives Product Guide

White Paper. Low Cost High Availability Clustering for the Enterprise. Jointly published by Winchester Systems Inc. and Red Hat Inc.

60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020

Exactly as much as you need.

Renovating your storage infrastructure for Cloud era

Enhancing Oracle VM Business Continuity Using Dell Compellent Live Volume

The Oracle Database Appliance I/O and Performance Architecture

How to Speed up Database Applications with a Purpose-Built SSD Storage Solution

Cisco UCS C24 M3 Server

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Transcription:

Lenovo Enterprise Product Group Version 1.0 March 2014 2014 Lenovo. All rights reserved.

LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON- INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This information could include technical inaccuracies or typographical errors. Changes may be made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any performance data contained herein was determined in a controlled environment; therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems, and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Any references in this publication to non-lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo, and ThinkServer. Intel and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. Microsoft, Windows and Exchange Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Apache Hadoop and Hadoop are trademarks of the Apache Software Foundation. LSI and LSI Design logo are trademarks or registered trademarks of LSI Corporation. 2

Contents 1.0 Introduction... 5 2.0 SA120 Overview... 5 3.0 SA120 Configuration... 7 3.1 Connectivity Considerations... 7 3.2 Server and SA120 Connectivity Scenarios... 8 3.3 LSI Management Tools... 11 4.0 Sample Use Cases and Benefits... 12 4.1 File Server / Unstructured Data... 12 4.2 Backup to Disk... 12 4.3 Database Acceleration... 13 4.4 Building Block for Distributed Storage... 13 5.0 Conclusion... 15 6.0 References... 16 3

List of Figures Figure 1 SA120 Front View... 5 Figure 2 SA120 Rear View with Optional Second PSU, SAS Controller and SSDs... 6 Figure 3 Basic SA120 Daisy-Chain... 8 Figure 4 High-Capacity SA120 Daisy-Chain... 9 Figure 5 Controller and Cable Redundancy... 10 Figure 6 Example Including SSD in First SA120... 11 List of Tables Table 1 Server and Adapter Support... 7 4

1.0 Introduction There are many choices for data storage today. Some of the factors influencing storage decisions are performance, reliability, scalability and acquisition cost. In addition to these basic requirements, IT managers are also evaluating new storage strategies, such as distributed storage, that are expected to provide better flexibility and reduced total cost of ownership. Traditionally, Direct Attached Storage (DAS) has been limited to a single server- single application use case. DAS is now also a critical part of distributed architectures. With legendary Think quality and features that provide multiple levels of performance, the ThinkServer SA120 DAS array is the natural choice when expanding your ThinkServer system for a single server application, or as part of a larger distributed solution. This document provides sample use cases and configuration guidelines for the ThinkServer SA120, including connectivity diagrams and overview of configuration tools. 2.0 SA120 Overview The ThinkServer SA120 is a 2U rack-mountable storage enclosure 1 that provides both 2.5 inchand 3.5-inch drive bays in a single enclosure. The SA120 is unique in that twelve 3.5-inch Hard Disk Drives (HDDs) mount in the front while four 2.5-inch drives mount in the rear of the enclosure. The rear 2.5- inch bays are reserved exclusively for optional Intel Enterprise solidstate drives (SSDs), providing an optimal tiered storage platform in one dense enclosure. Figure 1 SA120 Front View The SA120 supports direct attached 6Gbps SAS connectivity and integrates seamlessly with ThinkServer rack and tower models via supported ThinkServer LSI SAS and RAID adapters. Each 1 Tower conversion kit planned for availability after initial SA120 launch 5

dual-port adapter supports cascading up to four SA120 systems per port, providing a maximum capacity of (96) 3.5-inch HDDs and (32) 2.5-inch SSDs on a single server. Figure 2 SA120 Rear View with Optional Second PSU, SAS Controller and SSDs Servicing the SA120 is simple with tool-less components in addition to hot-swap disk drives, SAS Input/Output Controller Cards (IOCCs), fans and power supplies. Common power supplies and drives are shared with other ThinkServer systems, increasing convenience and reducing overall costs. 6

3.0 SA120 Configuration 3.1 Connectivity Considerations The SA120 is supported with current and prior generation ThinkServer systems with Operating System support following the connected server 2. Three ThinkServer LSI adapters are available for connecting to the SA120: ThinkServer LSI9207-8e 6Gb SAS HBA 3 - PCIe Gen 3 - No RAID, JBOD only ThinkServer LSI9280-8e 6Gb SAS RAID Adapter - PCIe Gen 2 - RAID 0, 1, 10, 5, 50, 6, 60-512MB cache - Battery Backup option ThinkServer LSI9286CV-8e 6Gb SAS RAID Adapter - PCIe Gen 3 - RAID 0, 1, 10, 5, 50, 6, 60-1GB cache - CacheVault option - CacheCade and FastPath I/O acceleration options Each card has two external 6Gbps SAS ports (no internal ports). Table 1 shows supported adapter cards and servers. Table 1 Server and Adapter Support 3 rd Generation 4 th Generation 9207-8e 9280-8e 9286CV-8e RD630 Yes Yes No RD530 Yes Yes No RD430 Yes Yes No RD330 Yes Yes No TS430 Yes Yes No RD640 Yes Yes Yes RD540 Yes Yes Yes RD440 Yes Yes Yes RD340 Yes Yes Yes TD340 3 Yes Yes Yes TS440 Yes Yes Yes 2 For supported operating systems on ThinkServer models, see the link in Section 6: References. 3 Available in May 2014. 7

When choosing an adapter card, consider these factors: - Server model - If hardware RAID is required - Performance requirements - Project budget SAS cables are available in multiple lengths. Care should be taken when selecting cables to ensure the length is adequate, as the SA120 and connected server may not be adjacent in the rack. 3.2 Server and SA120 Connectivity Scenarios Now, with an understanding of what is required in the connected ThinkServer, this section explores supported connectivity scenarios. 3.2.1 Basic Daisy Chain / Cascade This is the most basic connectivity scenario. Figure 3 shows the maximum number of SA120 enclosures on a single adapter port, although one, two, three or four enclosures may be used. Only one SAS IOCC is required per SA120. The advantage of this configuration is its low cost compared to other connectivity scenarios. Note that the Figure 3 example has no optional SSD in the rear, although SSD may be used in this basic configuration. Figure 3 Basic SA120 Daisy-Chain 8

Figure 4 shows a variation on the basic daisy-chain scenario, with four SA120 enclosures connected to one port of the adapter and four SA120 enclosures connected to the other adapter port. This depicts the maximum scalability of the SA120 solution. Figure 4 High-Capacity SA120 Daisy-Chain 3.2.2 Controller and Cable Redundancy This connectivity method requires two SAS IOCCs and two cables per SA120, and ensures the application continues if an IOCC or attached cable were to fail. Maximum expansion when using redundant paths is four SA120 enclosures. 9

Figure 5 Controller and Cable Redundancy 3.2.3 Data Acceleration with SSD Because the SA120 has the unique ability to store two different tiers of data with 12 largecapacity drives in the front and four fast SSD in the rear, it can easily become part of an application data acceleration solution. Many workload intensive applications are constrained by the performance limitations of the physical spinning media within a HDD. Lenovo ThinkServer enterprise SSDs from Intel provide consistently high I/O performance that is generally 150 times faster than 15K RPM HDDs, and have lower and more consistent access times. Although the price per gigabyte of SSDs continues to decline, they are still considerably more expensive relative to larger and slower HDDs. A cost effective strategy is to mix SSD with the HDD in a hybrid approach for the application s data. When applying this strategy, a traditional method is to manually and selectively place the more frequently accessed hot data on the SSD and the remaining data on the HDD. While effective for increasing performance, this can be time consuming and require further administration when the application or data changes. The optional CacheCade software for the ThinkServer LSI9286CV-8e 6Gb SAS RAID Adapter intelligently and dynamically handles the data placement without the need to monitor and configure applications. When reading data, CacheCade automatically copies the most frequently accessed data on HDD volumes to a much faster tier of SSD cache, removing many of the latency bottlenecks associated with traditional HDD-based data volumes. The example shown in Figure 6 includes two SA120 enclosures. Similar to non-ssd configurations, up to eight SA120 enclosures may be connected to one server in a single path 10

configuration or four in a redundant path configuration (redundant paths shown). This example shows the first SA120 with four SSDs and the second with none. When choosing the number and size of SSDs for CacheCade, it is important to recognize that the maximum CacheCade cache pool volume size is 512GB. In addition, the CacheCade volume supports RAID levels 0 or 1. CacheCade can be configured as read cache only, or read and write cache together. If write cache is enabled, it is recommended to configure the cache pool as a RAID 1 volume when protection of write-cached data is desired. Figure 6 Example Including SSD in First SA120 3.3 LSI Management Tools Similar to internal ThinkServer RAID adapters based on LSI technology, the ThinkServer external SAS and RAID adapters may also be managed and configured with LSI tools. Because the ThinkServer LSI9207-8e 6Gb SAS HBA is not a RAID adapter, no configuration is required. This adapter presents each attached drive to the operating system independently. It is up to the system administrator to create appropriate aggregated (or RAID-protected) volumes with operating system or software-based tools. The 9207-8e does provide a pre-boot firmware utility where specifications and status of the adapter and attached drives may be viewed; this interface is accessed during boot by pressing Ctrl-C when the adapter is initializing. Both the 9280-8e and 9286CV-8e RAID Adapters utilize the pre-boot WebBIOS Configuration Utility or MegaRAID Storage Manager (MSM) application for configuration of drives and volumes in the external SA120 enclosure. MSM also provides monitoring and alerting for the SA120 and associated drives. The WebBIOS interface is accessed during boot by pressing Ctrl-H when the adapter is initializing. MSM can be downloaded from http://support.lenovo.com, and requires installation at the operating-system level of the server. If the server already has an internal LSI- 11

based RAID adapter and MSM is installed, the same instance of MSM will display and manage both internal and external adapters, in addition to the SA120 enclosure. MSM will also display, and provide alerts from, the ThinkServer LSI9207-8e, but no configuration is required for this SAS HBA. The 9280-8e adapter is very similar to the ThinkServer RAID 700 adapter for internal drives, and the 9286CV-8e is similar to the ThinkServer RAID 710 adapter. For further information on configuring RAID and CacheCade, see links to separate guides Configuring ThinkServer RAID 700 Adapters and Configuring ThinkServer RAID 710 Adapters in the reference section of this document. 4.0 Sample Use Cases and Benefits ThinkServer SA120 fits well into many storage expansion scenarios, because of its simplicity, scalability and flexible performance choices. This section explores a few sample use cases, and the associated benefits of the ThinkServer SA120. 4.1 File Server / Unstructured Data Unstructured data is data that is not easily organized or categorized, such as documents, web pages and media files. Structured data, in contrast, typically refers to data in a database that is well organized and has defined fields that can be sorted and searched. Analysts have estimated that up to 80 percent of corporate data is unstructured. In an IT infrastructure, the typical repository for centralized unstructured data is a file server. Because of the large amounts of unstructured data created daily, one of the basic uses of the ThinkServer SA120 is also very common: expanding file server storage. Benefits of the SA120 in this application are: - Ease of integration with existing ThinkServer systems - Up to 384TB of external storage from one file server 4 4.2 Backup to Disk In addition to finding new ways for the initial storage of the massive amounts of data continuously created, strategies for backing up that data are changing to allow much faster backup (and restore). In some traditional IT environments, tape is still used for backup. However, in many cases, systems administrators have moved to using disk as a backup repository because larger datasets can no longer be backed up to slower tape drives in the time allotted for the backup. 4 With currently available 4TB drives. 12

Speed is even more important when considering recovery of backed-up data. In todays alwayson commerce environment, businesses cannot afford the loss of revenue while waiting for IT systems to be brought back online with recovered data. Benefits of using the ThinkServer SA120 in backup-to-disk applications are similar to the basic file server expansion advantages simple integration and massive scalability. 4.3 Database Acceleration As previously described, a database contains structured data. Because of a databases ability to search and sort data, Database Management Systems (DBMS) have become what companies rely on to run their businesses. Many DBMS, such as Microsoft SQL or Oracle Relational DBMS, use transaction logs or redo logs to record every transaction made to the database. This log is a file (or files), used to keep an audit trail, so that in the event of a system failure or database corruption, the log can be played back with DBMS tools and the database can be recovered to a known good state. As you might imagine, the log file is typically the bottleneck of a DBMS. This file is even more of a performance inhibitor when the DBMS is used for Online Transaction Processing (OLTP) applications. These applications may involve hundreds of transactions per second, with each transaction recorded in the log file. The log files are typically much smaller than the database files themselves, so a reasonable and cost effective solution is to place the log file on fast SSD and leave the remaining data on spinning disk. Because the ThinkServer SA120 offers both SSDs and larger HDDs in the same easily managed enclosure, it is a perfect choice for a DBMS. As described in the configuration section, further benefits are available when combining CacheCade with the SA120 and SSDs. If the database has other hot spots in addition to the log files, there is no need for time-consuming analysis or manual data placement. CacheCade and SSDs can be added to an existing LSI9286CV-8e RAID adapter and connected to the SA120 with no impact to existing data. 4.4 Building Block for Distributed Storage Distributed storage is the opposite of centralized storage. Centralized storage is the traditional way multiple users or servers have accessed persistent data. The term SAN (Storage Area Network) is sometimes used for centralized storage in an enterprise IT environment. The SAN storage device is typically a large monolithic array that requires a significant upfront expense, and is much more difficult and costly to scale when the storage frame has been completely filled with drives. Many distributed storage architectures work best with repeatable server and storage building blocks. One of the major benefits of these architectures is that they are easy to scale in a welldefined way, and allow IT shops to start small and pay as they grow, reducing the need for a large upfront investment. 13

Software Defined Storage (SDS) and storage virtualization are other trends to consider when contemplating distributed storage. The basic idea behind SDS is that the storage infrastructure is separated into two components: software to control and manage, plus simple cost-effective hardware for where the data resides. SDS and storage virtualization bring similar benefits to data storage as those we have seen in the virtualization of compute infrastructure: - Easier to scale - Increased availability - Faster deployment and time to value - Simplified hardware refreshes / repurposing of hardware - Aggregation (or federation) of disparate resources - Reduced vendor lock-in Here are examples of applications using distributed storage where the unique features of the SA120 are beneficial. 4.4.1 Microsoft Windows Server 2012 Storage Spaces Microsoft describes Storage Spaces as a new virtualization capability in Windows 8 and Windows Server 2012, which enables users to dramatically reduce the cost of highly available storage for virtualized or physical deployments, while also providing high resiliency and operational simplicity. Storage Spaces fits well into the general definition of SDS in that it provides a robust control plane for the SA120 data plane. Some of the features of Storage Spaces are: - Resiliency with RAID - Automatic tiering between disk with different performance levels - Thin provisioning - Failover clustering support 4.4.2 Microsoft Exchange Server for Email Microsoft introduced the Database Availability Group (DAG) feature in Microsoft Exchange Server 2010, and added improvements in Exchange Server 2013. This feature lets the administrator create an active mailbox database volume on one server, and passive mailbox databases on one or more additional servers. Exchange Server software then replicates the database from server to server. The DAG ensures high availability of the mailbox database without resorting to complicated and expensive shared storage (also known as SAN). 4.4.3 Data Analytics / Hadoop Data analytics is the process of examining data with the purpose of drawing conclusions about the information, and is used by businesses to make better decisions on customers or products. Big data is a subset of data analytics and the term is most often invoked when the size of the 14

data set to be examined is beyond the typical amount of data the organization has dealt with in the past. Because the data is sometimes as large as multiple petabytes (thousands of terabytes), conventional centralized shared storage architectures are too costly to implement and scale. There are other reasons that practitioners of big data analytics prefer server DAS over shared storage. To reduce the large amount of time required to process massive data sets, applications have evolved to allow a cost-effective single compute and storage node to process a smaller chunk of data, and then provide the ability to reassemble the analyzed chunks into a recognizable response. In addition, having the storage directly connected to the server allows consistent high performance as opposed to the sometimes unpredictable behavior of a SAN with many servers accessing the same central storage. There are many applications available for big data. One of the most popular is the open-source framework called Hadoop. Prominent users of Hadoop include Yahoo (where it was originally developed) and Facebook. Some have estimated Hadoop is used by over 50 percent of Fortune 500 companies today. Lenovo collaborates with many providers of supported Hadoop distributions, including Intel and Cloudera. 5.0 Conclusion The ThinkServer SA120 DAS array addresses a wide range of workloads, including fileserver, backup and database acceleration. Because of its low complexity and cost, it fits well into distributed storage architectures, yet can still provide multiple levels of performance for changing application needs. The SA120 integrates seamlessly into existing ThinkServer environments, and uses familiar ThinkServer tools for configuration and monitoring. 15

6.0 References SA120 Datasheet: http://www.lenovo.com/images/products/server/pdfs/datasheets/thinkserver_sa120_ds_ww.p df User Guide and Hardware Maintenance Manual (English): http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/sa120_hmm_ug_en.pdf MegaRAID SAS Software User Guide: http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/megaraid_swug_en.pdf 9207-8e User Guide: http://www.lsi.com/downloads/public/host%20bus%20adapters/lsi_ug_sas9207-8e.pdf 9280-8e and 9286CV-8e User Guide: http://www.lsi.com/downloads/public/megaraid%20sas/41450-04_reva.pdf Configuring ThinkServer RAID 700 Adapters (for 9280-8e): http://www.lenovo.com/images/products/server/pdfs/tech_resources/thinkserver_configuring _raid_500_700_tr.pdf Configuring ThinkServer RAID 710 Adapters (for 9286CV-8e): http://www.lenovo.com/images/products/server/pdfs/tech_resources/thinkserver_configuring _raid_710_tr.pdf ThinkServer Supported Operating Systems: http://www.lenovo.com/images/products/server/pdfs/datasheets/thinkserver_options_os_virt ualization_ds.pdf 16