MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

Similar documents
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

SURE TRIP RETRO KITS With RMS CURRENT MEASUREMENT

FP6000. Type ID Units Writable Possible Values. Count. TCP Register

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

www. ElectricalPartManuals. com MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay Highlights

MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Spectra RMS Circuit Breakers with microentelliguard Trip Units

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

www. ElectricalPartManuals. com Micro Versa Trip Plus and Micro Versa Trip PM Trip Units User's Manual

Sentron Systems Breaker

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

SACE Emax 2 Specification guide

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

INSTALLATION & COMMISIONING GUIDE

DEH-433. Warnings, Cautions, and Notes as used in this publication

GE Entellisys Low Voltage Switchgear. System Test Kit. User Manual

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P111. Three phase and earth fault overcurrent relays

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

URC Utility Relay Company

PXR 20/25 Trip Unit for Series NRX User Manual Power Xpert Release Trip Units

CURRENT PROTECTION RELAY SMPR-1

FP5000. Refer to for the latest information on this constantly evolving product

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

A3 ALPHA Meter. Electronic Meter for Electric Energy Measurement. TM B US English (en)

FP-5000 Feeder Protection

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

PHASE MONITOR RELAYS Product Summary

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

NEW ERA METER. Installation & Operation Guide NE METER

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MULTIFUNCTION MICROPROCESSOR PROTECTION RELAY TYPE IM30-G DATA BASE

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

SECTION SWITCHBOARDS

Common Departures Interconnecting Facilities Requirements

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Series 3000 User Manual and Product Features

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

SECTION ( ) LIGHTING CONTROL PANELBOARD

How to Control and Monitor a C441 Motor Insight via DeviceNet

Switchgear FEATURE. Basler Electric Company

Power Xpert Protection Manager for Eaton PXR 20/25 Trip Units. Quick Start Guide. Power Xpert Protection Manager Quick Start Guide Page 1

high RESISTANCE STOPLIGHT Instruction Manual C-101EM

Smart Power Flow Monitoring and Control

GE Multilin 350 Feeder Protection Relay Specifications

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Elastimold Molded Vacuum Recloser - MVR

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

www. ElectricalPartManuals. com .Basler Electric BE1-878 HIGH IMPEDANCE BUS DIFFERENTIAL RELAY ADVANTAGES ADDITIONAL INFORMATION APPLICATION Page2

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

ASCO Series 300 Generator Paralleling System

S Reclosers Kyle Form 5, Form 5 UDP, Form 5 DC NOVA Microprocessor-Based Recloser Controls Installation and Operation Instructions.

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

S Reclosers Kyle Form 5 Microprocessor-Based Recloser Control Installation and Operation Instructions. Contents

Electrical Demand Specification (Reference SOP: )

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

Section 4 Ground-Fault Protection Devices

For additional PowerFlex 4M data and general drive information, refer to the following publications:

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MiCOM P122C Time-Overcurrent Protection

Vigirex Ground-Fault Relays

60103 Circuit Breaker

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

etc-12 / etd Wiring, Set Up, Operation, and Test Instructions for: C O R P O R A T I O N Section II Instruction Manual

ISGS. Intelligent SwitchGear System The Flexible Solution

4. CIRCUIT BREAKERS. Functional Emergency Switching

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

GEK DFP100 Digital Feeder Protection Relays

Document C0. Use for:

Digital generator set control PowerCommand 1301

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

VIP 40/45 VIP 400/410

DGC-2000 DIGITAL GENSET CONTROLLER

Functional specification for Form 6 pole-mount recloser control

Transcription:

MPSC-2000 Microprocessor-based protection and metering devices for low voltage power circuit breakers ABB Power Distribution

Introduction For circuit breaker protection, metering and communications, the programmable MPSC-2000 offers the best value in the Industry MPSC-2000 solves traditional problems with protection, metering and communications capabilities on low voltage power circuit breakers, while also providing the best value in the industry. As a third generation microprocessor-based device, MPSC-2000 reflects the ABB commitment to continuous improvement by building on the solid record of MPS and MPS-C trip units installed on ABB breakers for over a decade. The ULapproved MPSC-2000 also demonstrates the ABB focus on value by adding new features such as an LCD display with keypad access to protective settings and metering data, while keeping costs competitive with previous generation devices. MPSC-2000 is extremely flexible - suitable for 3-phase systems, with or without a neutral connection, and voltages between 208 and 600 VACRMS at 50 or 60 Hz. The device may be used for continuous currents to 4200 amps, ground currents to 1200 amps, and short circuit currents to 130kA. 1

Standard Features Protection MPSC-2000 is the first device to include Long Time, Short Time, Instantaneous and Ground trip protection as standard functions, all with user-selectable settings and curves. A single catalog number provides all relay characteristics - no rating plugs are required. MPSC-2000 protection functions are fully self-powered, taking tripping Local and remote access to change relay settings and curves are restricted to authorized personnel by password protection. energy from current conducted through the breaker without an auxiliary supply. The main memory module is non-volatile EEPROM, which stores all protection settings and current values at the time of the last trip and eliminates the need for battery backup. Metering and Information MPSC-2000 adds value well beyond the primary function of circuit A bright red mechanical target indicates circuit breaker tripping. The cause of trip can be determined by interrogation of the device using the keypad and LCD display. The target resets automatically when the unit is re-energized. protection by providing a long list of breaker operational history information as well as complete metering data with breakthrough accuracy for a power circuit breaker trip device. Current and voltage measurements are within 1% of breaker rating, and power indications are within 2% of breaker rating. MPSC-2000 provides user-friendly access to settings and metering data by an on-screen menu with prompts. The large, easily readable LCD display is also energy efficient. A 9-volt battery provides power for cold set-up and A self-monitoring feature continuously monitors the condition of the microprocessor. Normal operation is indicated by a red LED on the front panel, flashing at the rate of once per second. Any internal failure is signaled by a steady glow. The LED blinks at the rate of 5 times per second to indicate Long Time pickup, and continues to blink at this rate until reset or until the breaker is tripped. continuous LCD information display, even when the breaker is not closed and energized. The tactile touch keypad is impervious to contamination from dust, moisture and lubricants. 2

System Overview MPSC-2000 is supplied as standard equipment on all new K-Line and K-Line Plus low voltage circuit breakers... MPSC-2000 combines all of the quality and reliability you expect from the Micro Power Shield line of protection systems with the latest generation of metering and communications capabilities. MPSC-2000 is also a member of the ABB family of field-proven, advanced microprocessor based devices that includes DPU-2000 (distribution), TPU-2000 (transformer) and GPU-2000 (generator) protection. MPSC-2000 is the standard trip unit on all new K-Line power circuit breakers. The MPSC-2000 base unit includes standard features which are commonly expensive options on other devices. MPSC-2000 also solves traditional inconveniences of field start-up. As an electronic device, MPSC-2000 has no mechanical components to lose alignment or adjustment during shipment, and only normal protective settings must be field programmed prior to placing a circuit breaker in service. Circuit Breaker mounted components 3

System Overview Major components of the system include current sensors, the MPSC-2000, and a magnetic latch trip device, all of which are mounted integral to the circuit breaker to provide complete protection for overcurrent, short circuit and ground faults. A current sensor is integrally mounted on each phase of the breaker to supply a value of current flowing in the MPSC-2000 which is directly proportional to the current passing through the primary circuit. When the value of current in the primaries exceeds the trip unit setting thresholds for a given time in Long Time, Short Time and/or Ground functions, the MPSC-2000 sends a signal to actuate the magnetic latch, which trips the circuit breaker. Instantaneous function tripping occurs in the same manner without an intentional time delay. On three phase, four wire, wye systems provisions are made for input from a separately mounted sensor to obtain a residual connection of all four sensors for sensitivity to ground currents. Refer to IB 6.1.2.8-1A for available phase and ground current sensor ratings. The MPSC-2000 Long Time trip element algorithm samples the current, calculates the root mean square (RMS) value of system current, and trips when the RMS current is above the trip threshold. Short time and instantaneous tripping remain based on peak sensing methods to avoid an unnecessary delay caused by an RMS calculation. 4

Accessories MPSC-2000 is available in convenient retrofit kits for upgrading installed breakers with electro-mechanical, solid state, and earlier generation microprocessor trip devices The compact size of the MPSC-2000 allows it to be used to retrofit virtually any low voltage power circuit breaker by any manufacturer. And the modular approach to MPSC-2000 design provides added flexibility, with a separate CT module and on-board mounting of the optional VIM. The MPSC-2000 K-Line retrofit kit is supplied complete with CT module, sensors, magnetic latch, mounting hardware and instructions. Each K-Line retrofit kit includes the MPSC-2000, detailed instructions for operation and retrofit installation, and the following components: Current sensors Magnetic latch Barriers and supports Wiring harness Hardware BTSB The Benchtop Trip Simulator for Breakers (BTSB) is a microprocessor driven secondary current/voltage injection test set specifically designed for use with the MPS-C and MPSC-2000 microprocessor-based trip devices. The BTSB can test all facets of MPSC and MPSC-2000 operation, including the following: Instantaneous Threshold Short Time Threshold & Delay Long Time Threshold & Delay Ground Threshold & Delay Current Metering Accuracy Self-Power Level Verification Altogether, the BTSB can perform up to 35 tests on an MPSC, and all the tests are performed by true secondary current or voltage injection. There are also built-in calibration tests which can be performed to ensure that the BTSB is providing accurate results. 5

Specification Guide MPSC-2000 technical data and specification guide Protection: Trip settings shall be displayed on demand, and shall be userselectable at local or remote locations. Password access is required to restrict changes by unauthorized personnel. Protective functions and settings shall consist of the following parameters: [*refer to IB 6.1.2.8-1A for values] MPSC-2000 (current) Settings Rating 0.5 or 1.0 X breaker rating LT Pickup 0.5-1.0 X sensor rating (increments of 0.1) LT Delay Minimum, Intermediate, Maximum * ST Pickup 2-12 X sensor rating (integral increments) or DISABLED ST Delay Minimum, Intermediate, Maximum * ST Curve Definite, I 2 T INST Pickup 3-12 X sensor rating (integral increments) or DISABLED if INST not blocked Ground Pickup See ground sensor table * Ground Delay Minimum, Intermediate, Maximum * Ground Curve Definite, I 2 T Test Curve Long time, Short time, Instantaneous, Ground Demand Interval 15, 30 and 60 minutes I Unbalance 5-50% (increments of 1%) I Unbalance Delay 0.1-25.0 sec (increments of 0.1%) or DISABLED VIM (voltage) Settings V Unbalance 5-50% (increments of 1%) V Unbalance Delay 0.1-25.0 sec (increments of 0.1%) or DISABLED UV Pickup 1-600 volts (increments of 1 volt) UV Delay 0.1-25.0 sec (increments of 0.1%) or DISABLED Demand Interval 15, 30 and 60 minutes Metering: The following metering information shall be shown on demand on an easily readable LCD display with a minimum of 2x16 characters. Data selection is available by local keypad access or remote interrogation. Current and voltage measurements shall be within 1% of the circuit breaker rating and power indications within 2% of breaker rating. This information shall be available with applicable options to remote control systems through the communications features of the device. [*displayed only if optional VIM is attached] Load Values Ia, Ib, Ic or In *Van, Vbn, Vcn, Vab, Vbc, Vca *KW30, KVar30, KVA30, KWHr30, KVarHr30 *Power Factor *Frequency Demand Values Ia, Ib, Ic or In *KW30, KVar30, KWHr30, KVarHr30 Records Information: The trip device shall provide access to trip records on the LCD display as follows. This information shall be available to remote control systems through the communications features of the device. MPSC-2000 (current) Trip Events Fault ID: 1-16 (last event displayed at device; others are remote readable) Event type: [LT, ST, INST, GRND] Phase A, B, C or Neutral current: [readout in amps] Breaker Operations Counter number: Phase A, B or C KSI: VIM (voltage) Trip Events Event type: Vab, Vbc or Vca: [quantity] [readout in ka] [I Unbal, V Unbal, UV] [readout in volts] Each low voltage power circuit breaker shall be supplied with a breaker-mounted microprocessor device with 3-phase and neutral protection, metering and communications capabilities. The device shall comply with the requirements of ANSI C37.17. Standard trip functions shall include Long Time (LT), Short Time (ST), Instantaneous (INST) and Ground (GRND) current protection. SYSTEM APPLICATION: The trip unit will be suitable for 3-phase systems, with or without a neutral connection, and voltages between 208 and 600 VACRMS at 50 or 60 Hz. The device must be suitable for continuous currents up to 4200 amps, ground currents up to 1200 amps, and short circuit currents up to 130kA. POWER: Tripping functions shall be self-powered, requiring no auxiliary power source. Trip system memory shall be non-volatile and shall not require battery back-up or other control power to retain stored information. A battery or other power source must be provided for metering, interrogation and to change settings when the breaker is not energized. The battery must be a common off the shelf device. ENVIRONMENT: The trip device shall operate in an ambient temperature range from -20 o C to +55 o C. The unit shall 1) employ active and passive filtering techniques, 2) be impervious to and not have false operation due to EMI or RFI from any source as demonstrated by satisfactory testing in accordance with ANSI standards C37.90.1 and C37.90.2, respectively. DISPLAY: The device shall include the ability to view protection settings, modify protection settings with password authorization, view metering data and view operational history. VOLTAGE SOURCE REQUIREMENT: Voltage information for the system and for the trip device metering displays shall be derived by direct connections to the three phases of the circuit breaker being interrogated in order to retain the correct time relationships for power calculations. Circuit breaker-mounted potential transformers (PT s) shall condition the voltage signal for use by the trip system voltage interfaces. 6

ABB Power T&D Company Inc. 2300 Mechanicsville Road Florence, SC 29501 +1 (843) 665-4144 +1 (843) 667-5109 (FAX) http://www.abb.com/usa email: dsinfo@ustra.mail.abb.com