Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Similar documents
Saved Data playback Saved data in Memory card can be easily called out and played back on display

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d

PAPERLESS RECORDER. Specifications Sheet No.SPEC-1137E (1st Edition)

Paperless Recorder VGR-B100. Series

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface

Type : PHF INP-TN1PHFQR-E

ARF100 Paperless Recorder

Technical Information

PARAMETER LOADER FOR PAPERLESS RECORDER

Compact data logger offering best-in-class noise resistance and communication function

ARF200. Paperless Recorder Advanced Recorder

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

Type : PHF. INP-TN1PHFQRc-E

SX 6000 Paperless Recorder

Instruction Manual PAPERLESS RECORDER TYPE: PHU INP-TN1PHU-E

User s Manual RD-MV1000/RD-MV2000 M st Edition

Compact Controller M CC-M

Enhanced communication

DATA VIEWER FOR PAPERLESS RECORDER

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

Instruction Manual PAPERLESS RECORDER TYPE: PHF. INP-TN1PHFc-E

PR Series Paperless Recorders

midi LOGGER GL840 Quick Start Guide GL840-UM-850

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

DATA VIEWER FOR PAPERLESS RECORDER

BACnet Controller for General-purpose Building Applications

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

PCPR01 Paperless Recorder

Fuji Instrumentation & Control

8420/8421/ MEMORY HiLOGGER

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

midi LOGGER GL240 Quick Start Guide GL240-UM-852

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

XL112, XL114 ポータブルデータロガ

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

Color Printer Microjet Recorder Series

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder

DATA LOGGER Series SELECTION GUIDE

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

midi LOGGER GL240 Quick Start Guide GL240-UM-850

General Specifications

PARAMETER LOADER FOR PAPERLESS RECORDER

Simplified information where and how you want it.

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Web-enabled DAQ System

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Setting New Heights in Data Recording

User Manual. cmt-iv5 Startup Guide

High-powered control system for sophisticated processes

TDS-630. High Performance Easy Handling

Control Panel CP600 CP651, CP651-WEB

Datum-Y Portable Data Station (XL100)

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SV100 Video Recorder

FUJI UG SERIES PROGRAMMABLE OPERATION DISPLAY USER S MANUAL. <Notes on Using UG221H- LE4, LR4> TYPE: UG221H-LE4 UG221H-LR4 FEH374

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

GV-IP Decoder Box Plus User s Manual

Digital Indicator Solutions

NF760 Batch Controller

Trident and Trident X2 Digital Process and Temperature Panel Meter

BACnet. b3810 Series Local Controllers

, , MEMORY HiLOGGER

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

Control Panel CP600 CP635-FB, CP635-FW

Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

Control Panel CP600 CP635, CP635-B, CP635-WEB

Integrated Recorder GX-1

PXR Series Advanced Self-Tuning Temperature and Process Controllers

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000

Samba PLC+HMI SM35-J-RA22

RD2000, 5.6" display. All models shown smaller than actual size.

Control Panel CP600-eCo CP604, CP604-B

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy

Technical Information

INPUT Input point Measuring cycle Input type Disconnection detection Input filter

High Voltage DC Meter

DIGITAL INDICATING CONTROLLER

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

HIGH-VOLTAGE DC METER

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

DATA LOGGER Series SELECTION GUIDE

Programmable Display. Feel the difference in power of expression, speed and networking capability. 9027NE1

User friendly and easy to program

Andover ContinuumTM Infinet II

Touch Panel Monitor UT3-B15 Series

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

SILVER SERIES OPERATOR INTERFACE TERMINAL

Transcription:

Type: PHU Long Term Record Data Saving years in Compact Flash (In case of using 5MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display Math and totalization These functions are available as standard. Communication Ethernet (0BaseT) is available. (option) Screen saver Period of nonoperation exceeds the setting value of parameter, recorder turns off the backlight of LCD. PC support softwares (Data Viewer/Parameter Loader) Supplied in a CDROM as a part of standard accessory 6point max. recording types of thermocouples, 5 types of resistance s and voltage/ current input are available ECNO:06b

Provides flexibility and variety in the handling of record data. Status Display Allows you to display screen name, calendar, alarm information, recording status, writing status of measured data in Compact Flash, and fitting status of the card into the recorder slot. Time display Indicates the time and time scale of recorded data. Trend Display Allows you to view measured result in waveforms. Digital Display Allows you to view measured values in a digital form. Key panel Allows you to perform the recording start/stop, selection of display, setting, data display/change. Power indicator During power on, LED turns on. While screen saver is working, it flickers. About years' worth of data can be recorded in Compact Flash (5 MB). When recorded in ASCII mode, for channels, and with a recording cycle of 0 seconds. Mathematics function (programming formula) as standard You can program formula using below operand. Addition, Subtraction, Multiplication, Division Absolute value, X to the power of Y, Logarithm, Natural logarithm, Exponential function, Humidity, Average value, Maximum value, Minimum value. Communication Ethernet (0BaseT) is available. It has FTP, HTTP (Web server), SMTP and MODBUSTCP protocols. Calculation function offered as standard Subtraction Difference between the values of each channel can be calculated. F value calculation Extinction rate of bacteria by heat sterilization can be calculated per channel according to the measured temperature. Totalization Measured value of each channel can be totalized. Reference time can be selected from day, hour, minute and second. Square root extraction Square root extraction of the input value of each channel can be performed.

Wide variety of display mode Trend recording (horizontal) Measured result is horizontally displayed in real time. Trend recording (vertical) Measured result is vertically displayed in real time. Bar graph Measured values are displayed in bar graph. Analog meter Measured values are displayed in analog meters. Digital display Channel No., Tag No. engineering unit, and alarm information are displayed in digital form, in addition to measured values. Totalized data display Totalized data of each channel is digitally displayed. (If power failure occurs while in totalizing operation and the power is restored later, the data being totalized is cleared.) Historical trend display Past data saved to Compact Flash can be viewed. Scroll function is usable. Event summary display Alarm status and external control input status for each channel are displayed.

General specifications Mounting method Panel flush mounted Material steel sheet for case, PCABS for bezel External dimensions <Panel mount> and mass 00 x 00 x 0.5 mm, about. kg (point input) Power supply voltage 0 to AC, 50/60 Hz Power consumption About A (at AC) External terminals Screw terminals (M thread) Operate temperature 0 to 50 C (in case the th digits of code symbols is Y.) 0 to 0 C (in case the th digits of code symbol Input unit No. of inputs Measuring cycles Recording cycle Input signal Input types Burnout function Calculation function Mathematics function Formula Addition, Subtraction, Multiplication, Division Absolute value, X to the power of Y, Logarithm, Natural logarithm, Exponential function, Humidity, Average value, Maximum value, Minimum value. Input signal ( to 6), Totalize (ch to ch), Analog input (ch to ch), Constant (No. to No.60), Display unit Display Life of backlight Display contents Recording function Recording medium is E.) or or or 6 points 00ms/, points 00ms/, 6 points sec to hours Thermocouple: types (B, R, S, K, E, J, T, N, W, L, U, PN) : 5 types (Pt00, JPt00, Ni00, Pt50, Cu50) DC voltage: (0 to 50mV, 0 to 500mV, 0 to 5V or to 5V) DC current: (connecting optional shunt resistor to input terminal) Selected from the key panel (the same type should be set for every channels) Equipped with thermocouple and resistance inputs as standard. Primary delay filter, scaling, calculation of difference between channels, F value calculation, totalization, and square root extraction It can be set main formula and temporary one. Communication input (No. to No.6) " TFT color LCD (00 X 600 dots) (The LCD may have some pixels that do not stay on or off. Due to the characteristics of liquid crystal, the brightness may not be uniform, which is not a failure.) 50,000 hours Trend display (in vertical and horizontal direction) selected in the refreshment cycles of sec to hours. Scale display/nondisplay selectable Bar graph or analog meter display (refresh cycle: second) Digital display (in refreshment cycle of sec) Event summary display (alarm and message summary) Historical trend display (Compact Flash memory data.) Totalized data display Group setting ( groups at the maximum) Compact Flash card (Format as FAT6 or FAT, or recorder can t read and write.) Specifications Memory capacity GB, max. Recording method Writing starts in fixed cycles by turning ON the REC key on the front panel. Data is recorded in a new file every time the recording starts. Data save cycles Links to refreshment cycle of the trend display Data format ASCII About 66 bytes per sampling (at channel inputs) Binary (Data cannot be read directly into Excel, etc.) About 0 bytes per sampling (channel input) Trend data Maximum value and minimum value are saved from the data that are sampled in measuring cycles. Event data Alarm data and message data are saved. Totalized data Stores data totalized during specified period of time. Storage capacity About.5 years at display refresh cycle of 0 seconds (ASCII) About 6 years (Binary) (channel recording, 56MB compact flash used) Amount of memory The display unit displays how much the memory used card has been used via bar graphs. The recording will stop if the amount of recorded data exceeds the capacity. Alarm function No. of settings Type of alarm Indication Output Reference performance Others Optional specifications Alarm relay output Up to alarms are settable for each channel. High/Low limits Alarm status is displayed on digital display unit when an alarm occurs. Histories are displayed in the alarm summary. 0 points as relay output (option) 6 points as opencollector transister output (option) Indication accuracy ±(0.5% digit) of input range Accuracy of the next range is ±(0.% digit). Thermocouple B: 00 C to 600C, thermocouples R and S: 0 C to 00 C, thermocouples K, E, J, T, L, and U: 00 C to 00 C Indication resolution 0. C Reference junction ±0.5 C Compensation accuracy (Thermocouples R, S, B and W: ±.0 C) Input resistance About M Clock With calendar function Memory backup Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a builtin lithium battery. Trend data is back up 5 Mbyte. Memory full alarm When the amount of recorded data exceeds the capacity of memory card, recorder can energize the alarm output. Low battery alarm When the battery for backup of clock and SRAM becomes low, recorder can energize the alarm output. Up to pieces of card, having 0point relay output, can be mounted max.0points. : a contact Alarm setting: individual channel or common output is available.

Alarm opencollector output input Communication (Ethernet) A card, having 6point open collector output, can be mounted. : open collector output A card, having 6point input, can be mounted. input: novoltage contact input Contents of control: Recording start/stop, Message setting, F value caliculation resetting, Totalizing start/ stop, Totalizing reset, LCD turning. 0BaseT FTP server * (Internet Explorer 6. FFFTP or Comand Prompt are available) HTTP server * (Web server. Internet Explorer 6 is available) SMTP (email client) MODBUSTCP * Netscape and Mozilla Firefox are not available Specifications PC support software (standardsupplied CDROM) O/S Windows XP/000 PC/ATcompatible Operation on PCseries machines by NEC is machine not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. Required memory 6 MB or more capacity Contents The following types are included as standard. ) Data viewer software It allows you to view the past trend recorded data from the data saved to the Compact Flash on PC. Historical trend and event display functions are provided. ) Parameter loader software It allows you to perform setting/change of various parameters on PC. A convenient PC support software package is included as standard Past data saved to Compact Flash can be viewed on personal computer. Parameters for the recorder can be easily set and changed from personal computer. Historical trend data screen Parameter setting screen Before use, install PC support software supplied as standard. O/S: Windows XP/000 Required storage capacity: 6 MB Provide PC card adapter separately. Recomended type: SDAD (SanDisk Co.) PC/ATcompatible machine Operation on PCseries machines by NEC is not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. Before use, install PC support software supplied as standard. O/S: Windows XP/000 Required capacity of memory: 6 MB A communication cable between recorder and pc is optional. Type: PHZP0 PC/ATcompatible machine Operation on PCseries machines by NEC is not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. 5

PUSH PUSH PUSH PUSH DO0 DO0?iTr?j DO6 DO0 DO0?iTr?j DO6 DO0 DO0?iTr?j DO6 DO0 CH CH6 6 CH CH CH º i 0 5 CH CH6 6 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 N DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 N DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH CHCH 5 6 0 CHCH 5 6 0 CH CH CH º i 0 5 CH CH6 º i 6 DO0 º i?itr?j DO6 º i CH0 0 CH0 CH5 5 CH CH6 º i 6 6 CH CH 5 CH6 CH CH CH 5 6 0 CH 0 CH CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 0 CH5 5 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CHCH CH5 CH5 5 ã i 5 ã i LAN Communicator LAN Communicator 0 0 5 6 5 6 5 6 5 6 CH0CH 00AC?` 00AC?` 6 CH0 CH CH CH CH 0 5 6 0 ã i CH5 CH6 CH CH º i 5 6 50 5 5 5 5 DO DO DO DO DO5 DO6 DO DO DO DO0 N 6 RMODULE CHCH CH 5 CH6 CH 6 RMODULE CH 50 CH CH CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 5 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH 5 6 0 CH 0 CHCH CH RMODULE CHCH CH 6 RMODULE CH 50 CH 5 0 5 CH CH 5 5 0 CH5 5 L L 6 Outline Diagrams (Unit: mm) input points 00 Panel 0.5 5 relay terminal Ethernet terminal (option) input terminal transistor terminal input points 00 Panel 0.5 5 relay terminal Ethernet terminal (option) input terminal transistor terminal 00 00 RMODULE RMODULE RMODULE 5 5 ã i CH CH ã i CH 5 CH5 5 5 ã i CH CH ã i CH 5 LAN Communicator 0 5 6 5 6 CH0CH 00AC?` 6 CH0 CH CH CH CH 0 5 6 0 ã i CH5 CH6 CH CH º i 5 6 50 5 5 5 5 CH0 CH CH CH CH 0 5 6 0 ã i CH5 CH6 CH CH º i 5 6 50 5 5 5 5 º i L t t Mounting bracket ( to points) t t Mounting bracket ( to points) (0 to points) input points 00 Panel 0.5 5 relay terminal Ethernet terminal (option) input terminal transistor terminal 00 RMODULE CH LAN Communicator 5 6 CH 00 0 0 CH 5 6 5 6 CH 0 CH0CH RMODULE CHCH6 CH0 0 RMODULE 00AC?` DO DO DO DO DO5 DO6 DO DO DO DO0 N 0 0 L CH CH 5 6 ã i CH5 CH6 06 05 6 0 0 t t Mounting bracket ( to points) (0 to points) ( to points) 6 input points 00 Panel 0.5 5 relay terminal Ethernet terminal (option) input terminal transistor terminal 00 t t Mounting bracket ( to points) (0 to points) ( to points) ( to 6 points) Panel cutout 0 60 MIN 0 MIN 0 6

External connection diagrams relay terminal M screw DO DO DO DO DO5 5 DO6 6 DO DO DO DO0 0 5 6 0 M screw relay terminal 00 to AC 50/60Hz M screw DO DO DO DO DO5 5 DO6 DO DO DO DO0 0 5 6 0 transistor terminal input terminal M screw M screw DO DO DO DO 5 DO5 6 DO DO DO PCD 50 6 6 6 6 65 5 66 6 6 6 6 0 V DC DO DO0 DO DO DO DO DO5 DO6 0 5 6 5 5 5 5 55 56 5 5 5 60 5 6 0 Number of input points = to points M screw Number of input points = 0 to points CH CH CH CH CH5 CH0 CH CH CH CH Thermocouple Thermocouple 5 6 0 5 0 5 6 0 6 0 5 5 6 50 5 5 5 5 Thermocouple Thermocouple CH6 CH CH CH CH5 CH6 CH CH Number of input points = to points Number of input points = to 6 points CH CH0 CH CH CH CH CH CH0 CH CH Thermocouple Thermocouple 55 56 5 5 5 60 6 6 6 6 65 66 6 6 6 5 6 0 5 6 0 5 6 0 000 0 00050600 Thermocouple Thermocouple CH CH5 CH CH CH CH CH5 CH6 Note) For current input, connect an optional shunt resistance to a voltage input terminal.

Code Symbols PHU 5 6 0 0 0 V Digit Specifications <Number of input points> points points points 6 points < input> Without With (6 points) <Modification No.(fixed)> <Display (instruction manual)> English <> Without 0 relay points 0 relay points Transistor (open collector) 6 points 0 relay points transistor (open collector) 6 points 0 relay points transistor (open collector) 6 points <Ethernet> Without With Note 0 E 0 5 Y E Note: Input signals are classified into the following groups. Make the setting so that the consecutive channels (ch and ch for example) are assigned the input signal categorized in the same group. Group : Thermocouple ( kinds), 50mV Group : Pt00. JPt00, Ni00, Cu50, Pt50 Group : 500mV Group : 5V, 05V Input signals can be arbitrarily selected for channels and and and 6. Item Scope of supply Quantity Main unit Panel mounting bracket CDROM (PC software and Instruction manual) Noise filter for power cable Option Item Type Specifications Shunt resistor for DC current input PHZP00 0Ω±0.% PC loader communication cable PHZP0 With USB A and USB minib Connector CDROM (PC software and instruction manual) PHZP50 PC card adapter for Compact flash PHZP050 Maker : Sandisk Compact flash (5MB) PHZP05 Note : Windows, Excel and Internet Explorer are registered trademarks of Microsoft Corporation. Note : SanDisk compact flash is a trademark of SanDisk. Note : PC series are registered trademarks of NEC Corp. Note : MODBUS is the registered trademark of AEG Schneider Autmation International. Note 5: Netscape is the registered trademark of Netscape Communication Corp. Note 6: Mozilla Firefox is the registered trademark of Mozilla Foundation. International Sales Div. Sales Group Gate City Ohsaki, East Tower,, Osaki chome, Shinagawaku, Tokyo 00, Japan http://www.fujielectric.com Phone: 55, Fax: 555 http://www.fujielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan 0/0FOLS