Super universal modules

Similar documents
TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Digital input modules

Resistance measuring module

TXM1.8RB. TX-I/O Blinds module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Power supply module, bus connection module

BACnet/IP Web Interface

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Island bus expansion module

Rotary version, three-position control

Web interface BACnet/IP

Room unit with PPS2 interface

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Room unit with PPS2 interface

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Air damper actuators

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Rotary actuators for ball valves

Interface converter for VAV compact controllers

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Extension module for lighting control

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Fast running actuators for air dampers

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Air Damper Actuators Modbus RTU

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Handheld Tool for VAV compact and modular controllers

Airflow Pressure Sensor

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

TX-I/O Product Range. Features. Description. Document No January 24, 2007

Compact room automation stations, BACnet/IP, AC 230 V

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Air Damper Actuators Modbus RTU

Room Temperature Controller

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

Electromotoric actuators

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

VAV modular controller

Room automation station

VAV compact controller

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Room Automation Station, BACnet/IP, AC 24 V

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room automation stations

Non-communicating room controllers

Room unit with PPS2 interface

Semi flush-mounted room temperature controllers with LCD

RMZ790. Operator Unit. Building Technologies. Synco 700

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Communication module to connect M-bus devices to POL6xx.xxx controllers.

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Electromotoric actuators

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Touch Panels 10.1" and 15.6"

Universal Controller

Room unit with PPS2 interface

Electromotive actuators for combi valves

Accessories and options

Climatix programmable controller

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Automation stations modular series

Electromotoric actuators for stroke valves

Impulse switching module

Automation station, compact series

Freely configurable flush-mounted room operator unit for KNX PL-Link

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Product and functional description

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

Non-communicating room controllers

Product and functional description

Product and functional description

LON Module for Variable Speed Drive

Immersion Temperature Sensors

SEH62.1. Digital Time Switch

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Automation stations compact model

Signal Doublers. VariTrans A 20300

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Rotary actuator for ball valves KNX / PL-Link

TX-I/O Functions and operation

AEW Pulse Adapter. Building Technologies

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Transcription:

s 8 174 TX-I/O Super universal modules TXM1.8X TXM1.8X-ML Two fully compatible versions: TXM1.8X: 8 inputs/outputs with LED signal / fault indication TXM1.8X-ML: As TXM1.8X, but with additional local override facility with LCD display (LO/ID to ISO 16 484-2) 8 universal I/O points, individually configurable as Digital input: maintained contact, pulse or counter Analog input: sensor, 0..10V, 4..20mA Analog output: 0..10V, 4..20mA (I/O points 5... 8) Compact DIN format, small footprint Separate terminal base and plug-in I/O module for convenient handling Self-establishing bus connection for maximum ease of installation Terminal isolation function for fast commissioning I/O module replaceable in seconds, without rewiring and without affecting the full functioning of the remaining I/O modules All terminals are directly on the I/O modules, allowing direct connection of field devices without additional terminal strips. Simple strategy for operation and display I/O status LED for each I/O point; mode of operation (N/C or N/O) and brightness depend on I/O function LEDs and LCD for fast diagnostics Double-sided labels for identification of all I/O points CM2N8174en_11 2017-07-05 Building Technologies

Functions The modules support the following I/O functions: Function Signal type (TRA) Signal type Description Status signal Status pulses Counter pulses Voltage, current, resistance and temperature BI NO BI NC BI Pulse NO BI Pulse NC CI El (100Hz) CI Mech (10/25Hz) AI 0-10V AI 4-20mA AI 0-20mA D20 D20R D20S C 10 I420 I25 Volt-free, interrogation (maintained contact), N/O contact Volt-free, interrogation (maintained contact), N/C contact Volt-free, interrogation (pulse), N/O, N/C contact Volt-free, N/O contact, interrogation (pulse) Counting frequency max. 100 Hz (electronic counter) max. 25 Hz (mech. counter) DC voltage 0... 10 V DC current 4... 20 ma DC current 0... 20 ma Please note that the max. current is 20 ma! AI 2500 Ohm R2K5 Resistance 2500 Ω AI Ni1000 extended Ni1K LG-Ni 1000 ohms, up to 180 C AI Ni1000 R1K LG-Ni 1000 ohms AI PT1K375 Pt1K 375 Pt 1000 (SA) AI PT1K385 Pt1K 385 Pt 1000 (Europe) AI Pt1000 P1K Resistance Pt 1000 ohms and resistance transmitter AI T1 (PTC) T1 PTC AI NTC10K NTC10 K NTC 10 K AI NTC100K NTC100 K NTC 100 K Proportional output signals AO 0-10V Y10S Proportional control output, DC 0... 10 V, with storage of control value AO 4-20mA Y420 Proportional control output, current DC 4... 20 ma (I/O points 5 8 only) For a detailed description of these functions, please refer to document CA110561, "TX-I/O functions and operation". Compatibility Support of signal types and functions in different building automation and control systems: see TX-I/O Engineering and installation manual, CM110562 Type summary ASN Delivery Accessories Super universal module TXM1.8X Super universal module TXM1.8X-ML with LCD display and local override The terminal base and the electronic plug-in unit are interconnected and delivered in the same box. The available accessories include address keys, label sheets, and spare transparent label holders. Refer to data sheet CM2N8170. 2/10

Technical and mechanical design For a description of the features common to all TX-I/O modules, please refer to the TX-I/O Engineering and installation manual, document CM110562. Indicators and operator controls Connection terminals (No. 1 screwdriver for slotted or recessedhead * screws) with test pickup (for 1.8...2 mm pins) and terminal number Signal designation Override status LEDs (yellow) Address key and module status LED LCD panel (TXM1.8X-ML only) I/O point numbers Override button (TXM18X-ML only) I/O status LEDs (green) * Combined slotted / recessed-head screws from mid-2012 I/O status LEDs Module status LED Address key The I/O status LEDs (green) indicate the status of the inputs and outputs (peripheral devices) They are also used for diagnostics The module status LED illuminates the transparent address key The LED (green) shows the module status as a whole (as opposed to the status of the I/O points) It is also used for diagnostics The module operates only with the address key inserted The module address is mechanically encoded in the address key When replacing the I/O module, the address key must be swiveled outward. It remains plugged into in the terminal base. Local override and LCD display (TXM1.8X-ML only) For a detailed description, please refer to document CM110561, "TX-I/O Functions and operation". Override button Pressing an button in the middle enables or disables the local override Pressing "+" or " " respectively increases or reduces the output value. Only outputs can be overwritten. Any attempt to overwrite an input results in an error indication. 3/10

Override status LED LCD display Warning The yellow "Override" LED indicates that local override is active The following information is displayed for each I/O point: Configured signal type Symbolic display of process value Information for diagnostics. All safety-relevant functions must be implemented with external solutions The local override must not be used for safety shutdown operations In compliance with the standard (ISO 16 484-2, Section 3.110), the module executes all local overrides directly, without safety precautions or interlocks. Full responsibility lies with the operator. Module labeling The plug-in I/O module has a removable transparent cover (the label holder) for insertion of a label. 2 1 8172z11 Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/E and may not be disposed of as domestic garbage. Dispose of the devices through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Engineering, mounting, installation Please refer to the following documents Document TX-I/O functions and operation TX-I/O Engineering and installation manual Replacement of legacy modules Number CM110561 CM110562 CM110563 4/10

Mounting Permitted orientation The TX-I/O devices can be installed in any orientation: It is important to provide adequate ventilation so that the admissible ambient temperature (max. 50 C) is not exceeded. Technical data Supply (bus connector on side) Operating voltage range Max. power consumption TXM1.8X 2.2 W TXM1.8X-ML 2.3 W (for the sizing of power supplies, see CM110562) DC 21.5... 26 V (SELV / PELV) or DC 24 V class 2 (S) Protection All terminals of the modules Against shortcut and incorrect wiring with AC / DC 24 V Bus connector on side No protection! Field devices Insulation resistance The of the connected field devices against mains voltage must comply with the requirements for safety extra-low voltage (SELV) or protection by extra-low voltage (PELV) as per HD 384. Measuring cables Cable material Solid or stranded copper wire Cable cross section See manual CM110562 Permitted cable length max. 300 m DC output (field supply) (, Terminals 3, 11, 20, 28) Nominal voltage (derived in the module from the module supply voltage) Admissible current per module DC24 V Max. 200 ma (total for all 4 terminals) AC/DC output Voltage AC / DC 12... 24 V (field supply) Admissible current per module Max. 4 A (total for all 4 terminals) (, Terminals 7, 15, 24, 32) Fuse T 10A, in power supply module / bus connection module Caution! Wiring of the AC/DC 24 V supply: se cable cross section suited for 10 A according to local regulations. Digital inputs / counter inputs Digital inputs are not electrically separated from the system electronics. Mechanical contacts must be volt-free. Electronic switches must comply with SELV / PELV standards. Counter inputs faster than 1 Hz that are routed for more than 10 m in the same trunking as analog inputs must be shielded. Contact sensing voltage Contact sensing current Contact resistance with contacts closed Contact resistance with contacts open DC 21.5...25 V 1.0 ma (initial current 6 ma) Max. 200Ω Min. 50kΩ 5/10

Min. closing / opening time [ms] including bouncing Max. bounce time [ms] Max. Counting frequency (symmetric) Maintained contact 60 20 Pulse contact 30 10 Counter mechanic 20 10 25 Hz Counter electronic..5..0 100 Hz Counter memory 0... 4.3 x 10 9 (32 bit counter) Analog inputs Correction of line resistance 1 Ω (calibrated In module) Signal type Range nder / over range Resolution (see page 2) Resistance Pt 1000 and AI Pt1000 0...2500 Ohm 0...2650 Ohm 100 mohm resistance transmitter AI 2500 Ohm 0...2500 Ohm 0...2650 Ohm 100 mohm Temp. measurement AI PT1K 375-50 180-52.5...185.0 C 10 mk AI PT1K 385 1) -50...400 (600) C 1) -52.5...610 C 20 mk AI NI1000-50 150 (180) C 1) -52.5...185.0 C 10 mk extended 1) AI NI1000-50...150 C -52.5...155.0 C 10 mk AI T1 (PTC) 1) -50...130 (150) C 1) -52.5...155.0 C 10 mk AI NTC10K 1) (-40...115 C) 1) -52.5...155 C 10 mk (25 C) AI NTC100K 1) (-40...125 C) 1) -52.5...155 C 10 mk (25 C) 1) 180 C, 600 C, NTC: only with reduced hum injection Voltage measurement AI 0-10V 2) 0... 10 V 2) -1.5...11.5 V 1 mv 2) In case of open connection: negative voltage 3.1 V, 0.05 ma (open circuit detection) Current measurement AI 4-20mA 4...20 ma 1.6...22.4 ma 1 µa AI 0-20mA 0...20 ma -3.0...23 ma 1 µa (25 ma see CM10563) Load resistance 490 / 440 ohms, pulsing (cyclic interrogation of the I/O points) Note: if the peripheral device can not drive this load, the signal must be connected via a current measuring converter. Analog outputs Signal type Range nder / over range Resolution Output voltage AO 0-10V 0 10 V -0.05...10.6 V 1 mv Output current max. 1 ma Output current I/O points 5... 8 only) AO 4-20mA 4... 20 ma 3.92...20.96 ma 1 µa Output voltage ca. DC 15 V Load resistance 0... 500 Ohm Connection terminals Mechanical design Solid conductors Stranded conductors without connector sleeves Stranded conductors with connector sleeves (DIN 46228/1) Screwdriver Max. tightening torque Test pickups (test terminals) For pin diameter 1.8 2.0 mm Rising cage terminals 1 x 0.5 mm 2 to 4mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.5 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.25 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 No. 1 Screwdriver for slotted or recessed-head * screws with shaft diameter 4.5 mm * Combined slotted / recessedhead screws from mid-2012 0.6 Nm 6/10

Local override (TXM1.8X-ML only) Classification to EN 60730 Housing protection standard Ambient conditions Standards, directives and approvals Environmental compatibility Local override / indication device ISO 16 484-2, Section 3.11 Mode of operation of automatic electrical controls Contamination level Mechanical design Protection standard to EN 65029 Front-plate components in DIN cut-out Terminal base Operation Climatic conditions Temperature Humidity Mechanical conditions Transport / storage Climatic conditions Temperature Humidity Mechanical conditions Type 1 2 Protection class III IP30 IP20 To IEC 60721-3-3 Class 3K5 5... 50 C 5 95 % rh Class 3M2 To IEC 60721-3-2 Class 2K3 25 70 C 5 95 % rh Class 2M2 Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commercial, light-industrial and industrial environments E conformity (CE) CM1T10870xx *) L certification (S) L 916, L 864, http://ul.com/database CSA certification Class 4812 http://directories.csainternational.org/ RCM-conformity (EMC) CM1T10870en_C1 *) EAC conformity Eurasia conformity Product environmental declaration (contains CM2E8174 *) data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) Color Terminal base and plug-in I/O module RAL 7035 (light gray) Dimensions Housing to DIN 43 880, see "Dimensions" Weight Without / with packaging TXM1.8X 194 / 215 g TXM1.8X-ML 211 / 232 g *) The documents can be downloaded from http://siemens.com/bt/download. 7/10

Connection diagrams (examples) Digital inputs (1) (2) (3) (4) (5) 2 4 6 8 10 12 14 16 19 21 K1 K2 K3 K4 S5 8174z13 K1 K2 K3 K4 S5 Super universal module Status contact (N/O) Status contact (N/C) Pulse contact (N/O) Pulse contact (N/C) Electronic switch Terminal layout STOP Counter inputs TXM1.8X, TXM1.8X-ML I/O point (1) (2) (3) (4) (5) (6) (7) (8) System neutral ( ) 1) 2 6 10 14 19 23 27 31 Input (+) 4 8 12 16 21 25 29 33 Counter inputs faster than 1 Hz that are routed for more than 10 m in the same trunking as analog inputs must be shielded. Analog inputs (1) (2) 2 4 6 8 (3) 10 12 M B B1 B2 R3 (1) (2) (3) 2 4 6 8 10 12 3 7 11 DC 24 V V DC 24 V B4 B5 B6 (4) 14 16 V B7 8174z14 B1 B2 R3 B4 B5 B6 B7 Super universal module LG-Ni 1000 temperature sensor General temperature sensor Resistance transmitter r Active sensor with DC 24 V supply Active sensor with AC / DC supply Active sensor 0 20 ma or 4 20 ma (2-wire) Active sensor with external supply External supply must NOT be earthed (earth loop) Terminal layout TXM1.8X, TXM1.8X-ML I/O point (1) (2) (3) (4) (5) (6) (7) (8) Measuring neutral ( ) 1) 2 6 10 14 19 23 27 31 Input (+) 4 8 12 16 21 25 29 33 AC/DC sensor supply voltage 2) Selected from: 7, 15, 24, 32 DC +24 V sensor supply voltage 3) Selected from: 3, 11, 20, 28 8/10

Analog outputs (5) (6) (7) 19 21 23 25 27 29 (8) 31 33 Y1 Super universal module Actuator with input DC 0..10 V or 4... 20 ma Y1 7 V Y2 11 DC 24 V Y3 V Y4 8174z15_01 Y2 Y4 General device with input DC 0..10 V or 4... 20 ma, Supply AC / DC, DC 24 V or externally External supply must NOT be earthed (earth loop) Terminal layout tension TXM1.8X, TXM1.8X-ML I/O point (1) (2) (3) (4) (5) (6) (7) (8) System neutral ( ) 1) 2 6 10 14 19 23 27 31 Output (+) 4 8 12 16 21 25 29 33 AC/DC operating voltage 2) Selected from: 7, 15, 24, 32 2) DC +24 V operating voltage 3) Selected from: 3, 11, 20, 28 3) Terminal layout current TXM1.8X, TXM1.8X-ML I/O point (1) (2) (3) (4) (5) (6) (7) (8) System neutral ( ) 1) -- -- -- -- 19 23 27 31 Output (+) -- -- -- -- 21 25 29 33 AC/DC operating voltage 2) Selected from: 7, 15, 24, 32 2) DC +24 V operating voltage 3) Selected from: 3, 11, 20, 28 3) Caution! 1) 2) 3) All measuring / system neutral terminals are interconnected, not in the terminal base but in the plug-in I/O module. When this unit is pulled outward (into the "parking" position) there is no connection. The system neutral of a digital input can be connected to any system neutral terminal With analog inputs and outputs, the measuring / system neutral must always be connected to the terminal associated with that I/O point. All AC/DC 24V supply terminals are interconnected (in the I/O module, not in the terminal base). They are protected in the power supply module / bus connection module (T10A). Wiring of the AC 24/DC V supply (terminals 7, 15, 24, 32): se cable cross section suited for 10 A according to local regulations. All DC 24 V supply terminals are interconnected. They are protected in the module against shortcut and incorrect wiring. For wiring details refer to the TX-I/O Engineering and installation manual, CM110562. 9/10

Dimensions Dimensions in mm 90 67 45 22 44 70 77.5 7.1 98 108 64 3 8172M01 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2007 Delivery and technical specifications subject to change 10/10