TS 99 door control Hold-to-run control panel for GfA-ELEKTROMATEN drives with DES digital limit switch or NES mechanical limit switch Approvals and certificates TS 99 TS 99 Type test according to: DIN EN DIN EN 978 DIN EN 0--0 DIN EN ISO 89- TÜV NORD CERT GmbH TS 99 Hold-to-run control panel for DES / NES limit switches Technical data For all GfA ELEKTROMATEN drives with DES or NES Supply voltage: N~0V, PE / ~0V, PE / N~00V, PE / ~00V, PE Operating frequency: 0 / 0 Hz Mains supply ratings for external devices: 0V AC (.A) Permissible temperature range: -0...+0 C Housing Dimensions W x H x D [mm]: x 8 x 90 (7 ) IP rated when hard wired or IP if CEE plug used Protection against contact provided by covers for live parts Connection cable that plugs into the ELEKTROMATEN unit, insertable from below or above Design Integrated OPEN-STOP-CLOSE control device Safety reversing contactor (with independent shutdown options) Settings via selector switch with digital display Pluggable connection technology Connection cable running to ELEKTROMATEN available in various lengths Independent, programmable relay contact, e.g. usable for green traffic-lights or ramp enabling Slack-rope and pass-door plug-in connection points Accessories Emergency-stop switch Key switch For description and details on further accessories, see 8.09 Functions Automatic detection of DES or NES limit switches Change of rotating direction from control panel push buttons Adjustment of limit positions (only DES) and all functions from the operator level Selectable operating mode: CLOSE / OPEN in hold-to-run mode CLOSE in hold-to-run mode / OPEN in self-hold mode Hold to run FULLY CLOSE FUNCTION / self-hold OPEN Keep the CLOSE button pressed until the door is completely CLOSED. If the CLOSE button is released early, the door will reverse automatically to its OPEN position. Status and information display (including display of most-recent faults); extensive evaluation via optionally-available service kit (adaptor + software, see 8.09) Cycle counter (non-resettable) Maintenance-cycle counter: Setting range:,000-99,000 cycles Display or switch to hold-to-run operation once the maintenance-cycle limit is reached Detects door / drive blockage (only DES); in this event the control deactivates the drive unit Dynamic run time monitoring (only NES): With every door movement, the time taken to run between the end positions is measured and compared with the most-recently set reference duration If the run duration is increased (pre-settable deviation), the control panel is deactivated Settable force monitoring in OPEN direction (only DES): For counterbalanced doors, sudden changes to the counter-balancing are detected Self-learning feature and consequently no activation of force monitoring function due to, e.g., a change in spring tension Version with mains switch Subject to alterations. (7_Ok) 8.0
Connection options Part no. installation drawing: 000 TS 99 N E S D E S 0 V /. A External N~0 V, PE ~0 V, PE N~00 V, PE ~00 V, PE Complete door control with connection kit TS 99 with connection kit, when hardwired With mains supply terminal and slide gland 009900.0000 TS 99 with CEE N~00V (-pole) 009900.0000 TS 99 with CEE N~0V (-pole) 009900.0000 TS 99 with CEE N~0V asym. (-pole) For SI. WS / SI.7 WS / ST. WS; with pluggable mains supply cable 009900.000 TS 99 with mains switch / isolator N~00V With mains switch / isolator in large cover 009900.000 TS 99 with mains switch / isolator N~0V With mains switch / isolator in large cover 009900.000 8.0 Subject to alterations. (7_Ok)
Separate connection kits, when hardwired Mains supply terminal and slide gland 000.0000 CEE N~00V (-pole.) 000.0000 CEE N~00V, IP (-pole) 000.0000 CEE N~0V (-pole) ; 000.0000 CEE N~0V asym. (-pole) For SI. WS / SI.7 WS / ST. WS; with pluggable mains supply cable 000.000 CEE ~0V (-pole) 000.0007 with connection kit N~00V Assembly kit for mains switch / isolator (complete) 000.000 with connection kit N~0V Assembly kit for mains switch / isolator (complete) 000.000 Subject to alterations. (7_Ok) 8.07
Accessories Designation Description DES connection cable NES connection cable Part no. Connection to ELEKTROMATEN drives with digital limit switch, pluggable on both sides; length of cable:,0m,0m 7,0m 9,0m,0m,0m,0m Further lengths available, upon request Connection to ELEKTROMATEN drives with mechanical limit switch, pluggable on both sides; length of cable:,0m,0m 7,0m 9,0m,0m,0m,0m Further lengths available, upon request 0000.0000 0000.0000 0000.00700 0000.00900 0000.000 0000.000 0000.000 0000.0000 0000.0000 0000.00700 0000.00900 0000.000 0000.000 0000.000 Spiral cable with junction box (IP) for System System = one junction box; Straight cable ends (.0m/0.m); length of coiled cable: 0.9m; max. stretched length:.0m 0000.00008 Spiral cable with junction box (IP) for System System = junction box + junction end box; Straight cable ends (.0m/0.m); length of coiled cable: 0.9m; max. stretched length:.0m 0000.0000 Are also required for system : + Junction end box (IP) for system With plug-in connection points for for pass-door and slack-rope switches Connection cable for system Pluggable on both sides, -wire, cable length:,m,m 8,m 0,m Splash guard 7 7 0008 0000.000 0000.000 0000.0080 0000.000 Mechanical protection against water; For spiral cable with junction box / and junction end box 00778.0000 Further accessories are described in Section 9 Example with system Example with system / 8.08 Subject to alterations. (7_Ok) /
Accessories with connection kit See Separate connection kits on page 8.07 Key switch Assembly kit for installation in small cover, supplied with keys 000 Emergency-stop switch Assembly kit for installation in small cover 000 Keypad cover For preventing unintentional pressing of keypad buttons (e.g. for use in underground car parks), increased protection against direct contact with water 0077.0000 GfA-Stick For use with smartphone or tablet PC together with the GfA+ App; for reading out and displaying of important data from the door control (e.g. programming, stored error logs, etc.) 0009 Arrangement Spare parts TS 99 TS 99 board Within cover incl. keyboard 000.0000 Bottom section of housing TS-B For installation of the TS-board 007 Cover kit TS-B + + Consists of: small cover, large cover 0009.0000 Cover kit TS-B for mains switch Spacer foot TS-B + + Consists of: small cover, large cover, prepared for mains switch pc. 0009.0000 000 Subject to alterations. (7_Ok) 8.09