CTO CSLS CHARM Cabinets

Similar documents
CTO Server and Network Cabinets

CTO Cabinets. Introduction. Delivers Electronic Marshalling enabled by CHARMs technology or controller cabinet for CHARM system.

CTO CSLS Field Enclosure

CTO CHARM Field Enclosure

S-series Horizontal Carriers

DeltaV Electronic Marshalling for Migrations

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

DeltaV M-series I/O Subsystem Horizontal Carriers

Free Standing DeltaV Double Door Cabinet

S-series Electronic Marshalling for Migrations

S-series Horizontal Carriers

DeltaV Bulk Power Supplies

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SIS Conditioning Components

DeltaV SD Plus Controller

DeltaV VerticalPlus I/O Subsystem Carriers

Free Standing DeltaV Single Door Cabinet

DeltaV Bulk Power Supplies

S-series Mass Connection Solutions

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

DeltaV SIS with Electronic Marshalling - Virtual Simulation

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

S-Series DeltaV Controller Interface for PROVOX I/O

M-series Intrinsically Safe I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

S-series DeviceNet Interface Card

M-series MQ Controller

Smart Commissioning. White Paper February 2018

M-series MX Controller

M-series I/O Subsystem Horizontal Carriers

S-series Foundation Fieldbus I/O

S-series Sequence of Events Card

DeltaV Control Network Hardware

M-series Foundation Fieldbus I/O

Smart Commissioning. White Paper January 2019

M-series Profibus DP Series 2 Plus Interface Card

Use of Cisco Switches on the DeltaV Area Control Network (ACN)

GE Measurement & Control. Packaged Systems. Bently Nevada * Asset Condition Monitoring

M-series DC to DC Power Supply

DeltaV Safety Instrumented System (SIS) with Electronic Marshalling

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

S-series H1 I/O Card with Integrated Power

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

Roxar CorrLog High Accuracy Corrosion Monitoring

M-series DeltaV Controller Interface for PROVOX I/O

S-series Electronic Marshalling

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

Roxar SandLog High Accuracy Sand/Erosion Monitoring

EUROTHERM PRO ESS AUTOMATION NETWORK. T754X series control enclosures. Product Specification

Power-Style QED-2, Series 2 Low Voltage Switchboards

S-series DeviceNet Interface Card

DeltaV Simulate. Introduction. Product Data Sheet April DeltaV Distributed Control System

FP-PS-4. Features. Installation

Electrical Demand Specification (Reference SOP: )

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Fast Control Response Requirement

S-series Profibus DP Interface Card

Configuration Software Suite

TRC-190 User s Manual

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Ovation Controller Model OCR1100

Room unit with PPS2 interface

M-series DeltaV Controller Interface for RS3 I/O

Keysight Technologies E3620A and E3630A Non-programmable DC Power Supplies. Data Sheet

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

DPS SERIES DC POWER SUPPLIES

Ovation Compact Controller

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

CONTROL PANEL WIRING SPECIFICATIONS

Vertiv VR Rack 1.0 GENERAL

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

S-series Electronic Marshalling

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

S-series IS Electronic Marshalling

DeltaV Ethernet I/O Card

ISASecure SSA Certification for DeltaV and DeltaV SIS

E-Series Site Preparation Guide

4C Standard Horizontal Mailboxes

Configuration Software Suite

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Agilent 66000A 1200 W DC Modular Power System, GPIB

SECTION ( ) LIGHTING CONTROL PANELBOARD

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

PD-6506, PD & PD-6524

M-series Profibus DP Series 2 Plus Interface Card

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Power Enclosure Components

FLEX Ex Spring Clamp Terminal Base

Sustain.Ability Honeywell Users Group EMEA. Adriano Canale How Universal I/O Can Help Save Design Cost and Project Execution Time

Transcription:

DeltaV SIS Process Safety System Product Data Sheet November 2017 CTO CSLS CHARM Cabinets Rear View CTO CSLS CHARM Cabinet. Delivers Electronic Marshalling enabled by CHARMs technology Reduce system footprint Eliminate I/O home run cables Significantly reduce cabinet design engineering Fully documented package Introduction The DeltaV SIS Configure-To-Order (CTO) CHARMs Smart Logic Solver (CSLS) Cabinets provide an off-the-shelf solution for faster project execution and reduced installation costs. CTO CSLS Cabinets are factory tested and ready for installation in technical rooms. Electronic Marshalling eliminates traditional I/O design tasks and allows field wiring to start long before safety strategies are finalized.

Benefits Delivers Electronic Marshalling enabled by CHARMs technology: The CTO CSLS Cabinets offer the full benefits of Electronic Marshalling. The individual channels can be defined for any combination of field signal type, as required by the safety equipment. This allows for 100 % utilization of channels, regardless of the I/O signal mix. Late changes are easily accommodated with minimal re-engineering and no rewiring. Reduced system footprint: Equipment room footprint is reduced by eliminating the traditional marshalling cabinets with cross wiring to traditional I/O cards. Significantly reduce cabinet design engineering: The CTO CSLS cabinets are pre-engineered and factory tested. The I/O flexibility allows the same design to serve a wide variety of I/O signals, conditioned individually by the CHARM. Field wiring design is complete at the terminal block. Fully documented package: Each cabinet is supplied with full documentation and engineering drawings showing internal layout, bill of materials and internal wiring. They are designed to meet local building code and industry best practices in order to deliver proven functionality with minimal costs. Product Description The CTO CSLS Cabinets offering comprises a range of preengineered solutions based on industry standard, preinstalled with CHARM I/O and related equipment, ready to be installed in an equipment room and connected to safety instrumentation or equipment. The cabinets are typical, free standing enclosures intended for floor mounting in equipment room areas, where temperature and humidity are controlled within the requirements for computer/electronic equipment. They come ready to receive incoming plant AC power. All internal wiring to power distribution components and grounding conductors has been tested at the factory. Before delivery, each cabinet undergoes a full in-house inspection, to assure that it is fully operational before shipping directly to site. Electronic Marshalling eliminates the need for any internal cross wiring and I/O rationalization there is typically no need for FAT at a staging facility. These cabinets can be ordered and delivered directly together with the DeltaV SIS electronic marshalling equipment and LS CHARM I/O to site to begin field wiring (FAT may be optional). The CTO CSLS Cabinets are configured by selecting a base enclosure model and required options to meet specific project needs. Base enclosure models are available: For different cabinet sizes / entry (Front Access or Front and Rear access). For different power distribution needs: DC powered or AC powered. For different world area design standards and regulations: EUR (Europe) and NA (US/Canada). Configurable options examples: the type of LS CHARMS (I.S. or non I.S.), side panels, cabinet light, nameplate engraving and injected power. All CTO CSLS cabinets come with following equipment installed. Primary and secondary 24VDC power distribution for LS CHARM I/O Cards and field instrumentation. Wire ducts or wire basket. Grounding bars. Wiring plan pocket. Emerson Name Plate Holder and blank name plate insert. DeltaV LS CHARM I/O equipment based on your configuration (and priced seperately): including CSLS carriers, CHARM base plates, standard terminal blocks, address plugs and terminals. The CSLS cards and LS CHARMs are not included and are to be ordered separately. The required number of (redundant) LS CHARM I/O cards and CSLS cards depends on the actual number and types of I/O that will be wired into the cabinet. The following sections provide a more detailed specification for the CTO CSLS Cabinets and available options. www.emerson.com/deltavsis 2

Overview of CTO CSLS Cabinets Base Models Base Model number Description # LS CHARM IO Power Requirements (Pri and Sec) Permitted Location / World Area EU-CAB-800F-192-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 192 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations. 192 230 VAC Safe Area EUR EU-CAB-800FR-480-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 480 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations. 480 230 VAC Safe Area EUR NA-CAB-800F-192-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 192 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations. 192 120 VAC Safe Area US/CANADA NA-CAB-800F-252-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 252 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations. 252 120 VAC Safe Area US/CANADA NA-CAB-800FR-480-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 480 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations. 480 120 VAC Safe Area US/CANADA NA-CAB-800FR-504-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 504 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations. 504 120 VAC Safe Area US/CANADA The CTO base model reference for cabinets uses the following naming convention: EUR or NA-CAB-XXXYY-ZZZIO-IP-DDDD, where EUR : Europe Design Standards and Regulations / NA : US/Canada Design Standards and Regulations. XXX = cabinet width (mm), e.g. 800, 1200. YY = F for Front only access (600 mm deep), FR for Front and Rear access (800 mm deep). ZZZ= maximum I/O s count in this CTO. IP= Incoming Power, DC=24V DC or AC=120/230V AC. DDDD= short description of content and purpose. www.emerson.com/deltavsis 3

Overview of CTO CSLS Cabinets models and Options : Default option setting o : Configure To Order option setting, different from default blank : option setting not possible for the base enclosure : Intentionally left blank to fill in your configuration choices Nameplate Engraving G Enclosure Options Base Model NA-CAB-800F-252-AC-CSLS NA-CAB-800FR-504-AC-CSLS World Area US/CAN US/CAN US/CAN US/CAN EUR EUR Power Input (DC: 24VDC, AC:120/230VAC) AC AC AC AC AC AC Enclosure Access (F: Front, FR: Front-Rear) F F/R F F/R F F/R # CHARMI/O 252 504 192 480 192 480 0 No 1 Yes NA-CAB-800F-192-AC-CSLS NA-CAB-800FR-480-AC-CSLS EU-CAB-800F-192-AC-CSLS EU-CAB-800FR-480-AC-CSLS Type of CHARMS (to be specified for each row of CHARMS) Cabinet Light Temperature Monitoring Door Fans Plinth Side Panels Door Hing Cable Routing Baying Kit Cable Clamps Rail Utility Socket Selection 24VDC for Injected Power Certification C L T F D S H B B R U V Z 1 Non I.S. 2 I.S. 1 No 2 LED light with motion sensor 0 No 1 Thermostat 1 Continuous Run 2 Thermostat Controlled 1 100mm N/A 2 200mm 0 No 1 Yes 1 Left Hinged N/A 2 Right Hinged 1 Cable Duct N/A 2 Wire Basket 0 No 1 Yes 0 No 1 Yes 0 No N/A 1 Yes 1 Front side No 2 Front side Yes 3 Rear side No N/A 4 Rear side Yes 0 No 1 CE N/A 2 CSA N/A N/A N/A Following more detailed options can be specified upon order (if applicable) : Disconnect switches for DC power feeds can be configured separately for CSLS power and for injected power inputs Type of utility socket : German-Russia / France-Poland / Switzerland / UK-Ireland / USA-Canada / Italy Power supply configuration : Power for CSLS and/or injected power (with diode), Front and Rear position in cabinet 24VDC for injected power : optionally prewired (according specification to be provided) Wiring color scheme different from default : US (L- Black, N- White) / EUR (L- Brown, N- Blue) Input Voltage different from default : US (120VAC) / EUR (230VAC) www.emerson.com/deltavsis 4

Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800F-252-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side) Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 3 CSLS carriers is included. Example BOM: Power Supply subassembly. 3 LS CHARM IO rails, for total of 252 LS I/O, 3 x CSLS Carrier with redundant Copper Ethernet connectors 21 x CHARM Base Plate 21 x CHARM Address Plug 252 x CHARM terminal blocks - Screw type 3 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Size of Wire Baskets: 150mm H x 54mm D www.emerson.com/deltavsis 5

NA-CAB-800F-252-AC-CSLS External Layout Drawing for NA-CAB-800F-252-AC-CSLS: Front and. www.emerson.com/deltavsis 6

Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800FR-504-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 3 CSLS carriers is included. Example BOM: Power Supply subassembly. 6 LS CHARM IO rails, for total of 504 LS I/O, 6 x CSLS Carrier with redundant Copper Ethernet connectors 42 x CHARM Base Plate 42 x CHARM Address Plug 504 x CHARM terminal blocks - Screw type 6 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View Size of Wire Baskets: 150mm H x 54mm D www.emerson.com/deltavsis 7

NA-CAB-800FR-504-AC-CSLS Rear View External Layout Drawing for NA-CAB-800FR-504-AC-CSLS: Front/Rear and. www.emerson.com/deltavsis 8

Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800F-192-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 2 LS CHARM IO rails, for total of 192 LS I/O, 2 x CSLS Carrier with redundant Copper Ethernet connectors 16 x CHARM Base Plate 16 x CHARM Address Plug 192 x CHARM terminal blocks - Screw type 2 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Size of Wire Baskets: 150mm H x 54mm D www.emerson.com/deltavsis 9

NA-CAB-800F-192-AC-CSLS External Layout Drawing for NA-CAB-800F-192-AC-CSLS: Front and. www.emerson.com/deltavsis 10

Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800FR-480-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A (One set for front & one for rear) AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 5 LS CHARM IO rails, for total of 480 LS I/O, 5 x CSLS Carrier with redundant Copper Ethernet connectors 40 x CHARM Base Plate 40 x CHARM Address Plug 480 x CHARM terminal blocks - Screw type 5 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View Size of Wire Baskets: 150mm H x 54mm D www.emerson.com/deltavsis 11

NA-CAB-800FR-480-AC-CSLS Rear View External Layout Drawing for NA-CAB-800FR-480-AC-CSLS: Front/Rear and. www.emerson.com/deltavsis 12

Dimensions Access Protection Category IP54 NEMA 12 EU-CAB-800F-192-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm/200mm Plinth configurable. Front Access single door, right/left hand hinged configurable, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 230 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 2 LS CHARM IO rails, for total of 192 LS I/O, 2 x CSLS Carrier with redundant Copper Ethernet connectors 16 x CHARM Base Plate 16 x CHARM Address Plug 192 x CHARM terminal blocks - Screw type 2 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. www.emerson.com/deltavsis 13

EU-CAB-800F-192-AC-CSLS External Layout Drawing for EU-CAB-800F-192-AC-CSLS: Front and. www.emerson.com/deltavsis 14

Dimensions Access Protection Category IP54 NEMA 12 EU-CAB-800FR-480-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm/200mm Plinth Configurable. Front Access single door, right/left hand hinged configurable, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 230 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 5 LS CHARM IO rails, for total of 480LS I/O, 5 x CSLS Carrier with redundant Copper Ethernet connectors 40 x CHARM Base Plate 40 x CHARM Address Plug 480 x CHARM terminal blocks - Screw type 5 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View www.emerson.com/deltavsis 15

EU-CAB-800FR-480-AC-CSLS Rear View External Layout Drawing for EU-CAB-800FR-480-AC-CSLS: Front/Rear and. www.emerson.com/deltavsis 16

How to order a CTO Cabinet? CTO CSLS Cabinets are pre-engineered solutions developed by Emerson s Project Management Office (PMO) and made available from Emerson Supply Chain. Please follow the steps below to configure and order a CTO CSLS Cabinet: 1. Specify the CTO Cabinet by selecting the base model and the options required for the project. A configuration tool is available to aid in the selection of the right combination of optioned CTOs. 2. Based on the specification, you will then receive: A quotation for the fully assembled Cabinet. The detailed specification (drawing package) matching your configuration, including the Bill of Materials. 3. Approve the drawing package for construction. 4. Order the CTO Cabinet as per provided quotation and approved drawings. 5. The CTO Cabinet is assembled, factory tested and delivered to site. The delivery includes the as-built drawing package (AutoCAD). For questions related to specific project quotations or order processing, please contact your local Emerson Sales office or your regional Emerson assembly center: For US/Canada St. Louis icenter: icenterstl.quotes@emerson.com For Europe Cluj icenter: Cabinets.Quotes@Emerson.com For Asia Pacific Singapore icenter: icentersgpquotes@emerson.com Project Customizations What if a CTO Cabinet is 90% what I need, but I really need my Cabinet to have Minor customizations as a variation or addition to the standard CTO offering can often be developed in such a way that the additional effort is incremental. In case your project would require a customer witnessed Factory Acceptance Test, this can also be accommodated. Please work with your local Emerson Sales office or regional Emerson assembly center to evaluate any impacts of requested customizations to cost, delivery time and certifications. System Compatibility CSLS Cabinets are compatible with DeltaV version 12.3 and above CSLS cards require DeltaV SZ Controllers Certifications The CTO CHARMs Cabinet designs are designed to meet CE and CSA personal safety and EMC requirements. The designs have been submitted for the following certifications: Conformity to the relevant European directives, including EMC (CE Marking) CSA Mark for US and Canada For Europe Design Standards and Regulations, the cabinet default comes with CE Certification. Optionally, no certification can be specified. For US/Canada Design Standards and Regulations, the cabinet default does not come with certification. The CSA Certification is optional. Refer to the DeltaV SIS with Electronic Marshalling or to the DeltaV SIS with IS Electronic Marshalling Product Data Sheet for certification information on the DeltaV SIS system components. www.emerson.com/deltavsis 17

Related Products CSLS cards must be ordered separately LS CHARMs must be ordered separately LS CHARMS requiring other terminal blocks than the standard terminal block should be ordered with the non-standard terminal block Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltavsis 2017, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.