NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

Similar documents
MEASUREMENT OF PATTERNED WAFER SURFACE DEFECTS USING ANNULAR EVANESCENT LIGHT ILLUMINATION METHOD

Polarized light scattering measurements of roughness, subsurface defects, particles, and dielectric layers on silicon wafers

A SUPER-RESOLUTION MICROSCOPY WITH STANDING EVANESCENT LIGHT AND IMAGE RECONSTRUCTION METHOD

Optical Topography Measurement of Patterned Wafers

ksa MOS Ultra-Scan Performance Test Data

INTERNAL DEFECT DETECTION IN THE VICINITY OF SI WAFER SURFACE USING EVANESCENT WAVE

HIGH PRECISION INSTRUMENT FOR MICRO SURFACE PROFILE MEASUREMENT BASED ON OPTICAL INVERSE SCATTERING PHASE METHOD

MEMS SENSOR FOR MEMS METROLOGY

High spatial resolution measurement of volume holographic gratings

Defect Repair for EUVL Mask Blanks

specular diffuse reflection.

DAMAGE INSPECTION AND EVALUATION IN THE WHOLE VIEW FIELD USING LASER

Microscopy. Marc McGuigan North Quincy High School Thursday, May 11, 2006

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

Inspection System for High-Yield Production of VLSI Wafers

2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes

Mu lt i s p e c t r a l

TFT-LCD Technology Introduction

Chapter 82 Example and Supplementary Problems

Compact Disc How it Works?

Chapter 24. Wave Optics. Wave Optics. The wave nature of light is needed to explain various phenomena

Optical Scattering. Analysis. Measurement and SPIE PRESS. John C. Stover THIRD EDITION. Bellingham, Washington USA

Surface and thickness profile measurement of a transparent film by three-wavelength vertical scanning interferometry

SURFACE FINISH INSPECTION OF WOOD USING 3D PROFILOMETRY

Comparison between 3D Digital and Optical Microscopes for the Surface Measurement using Image Processing Techniques

WORCESTER POLYTECHNIC INSTITUTE

Applications of Piezo Actuators for Space Instrument Optical Alignment

HOLOGRAPHIC FEMTOSECOND LASER PROCESSING AND THREE-DIMENSIONAL RECORDING IN BIOLOGICAL TISSUES

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

Analysis of Slanted Gratings for Lightguide Coupling

Supplementary Figure 1 Optimum transmissive mask design for shaping an incident light to a desired

Chapter 38. Diffraction Patterns and Polarization

Chapter 36. Diffraction. Dr. Armen Kocharian

Advances in Disk Metrology

Chapter 24. Wave Optics. Wave Optics. The wave nature of light is needed to explain various phenomena

Condenser Optics for Dark Field X-Ray Microscopy

Chapter 2: Wave Optics

MICHELSON S INTERFEROMETER

SOLAR CELL SURFACE INSPECTION USING 3D PROFILOMETRY

Chapter 36. Diffraction. Copyright 2014 John Wiley & Sons, Inc. All rights reserved.

Chapter 24. Wave Optics

Supporting information

Selective Optical Assembly of Highly Uniform. Nanoparticles by Doughnut-Shaped Beams

Michelson Interferometer

Intermediate Physics PHYS102

An Inspection and Measurement Technology Platform Leading the Way to More Advanced Manufacturing

Use of the surface PSD and incident angle adjustments to investigate near specular scatter from smooth surfaces

Optics for nonlinear microscopy

Benefiting from Polarization: Effects at High-NA Imaging

T-Solar Overview. * Patent-pending

Physics 1C, Summer 2011 (Session 1) Practice Midterm 2 (50+4 points) Solutions

H.-J. Jordan (NanoFocus Messtechnik GmbH), R. Brodmann (Brodmann Marketing & Vertrieb)

diffraction patterns obtained with convergent electron beams yield more information than patterns obtained with parallel electron beams:

Optics Vac Work MT 2008

Near Field Observation of a Refractive Index Grating and a Topographical Grating by an Optically Trapped Gold Particle

White-light interference microscopy: minimization of spurious diffraction effects by geometric phase-shifting

NEAR-IR BROADBAND POLARIZER DESIGN BASED ON PHOTONIC CRYSTALS

3D Surface Metrology on PV Solar Wafers

FRESNEL LENS DIMENSIONS USING 3D PROFILOMETRY

Textbook Reference: Physics (Wilson, Buffa, Lou): Chapter 24

AP* Optics Free Response Questions

Single Photon Interference

Lab2: Single Photon Interference

The Measurement System for Particle Size on Surface of Hard Disk Drive based on Experimental Light Scattering of BRDF Simulation

TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS

At the interface between two materials, where light can be reflected or refracted. Within a material, where the light can be scattered or absorbed.

Diffraction. Single-slit diffraction. Diffraction by a circular aperture. Chapter 38. In the forward direction, the intensity is maximal.

Confocal Raman Imaging with WITec Sensitivity - Resolution - Speed. Always - Provable - Routinely

Single Photon Counting Module

Light Tec. Characterization of ultra-polished surfaces in UV and IR. ICSO October 2016 Biarritz, France

Imaging Sphere Measurement of Luminous Intensity, View Angle, and Scatter Distribution Functions

INTERFERENCE. where, m = 0, 1, 2,... (1.2) otherwise, if it is half integral multiple of wavelength, the interference would be destructive.

Coupling of surface roughness to the performance of computer-generated holograms

2/26/2016. Chapter 23 Ray Optics. Chapter 23 Preview. Chapter 23 Preview

Emission characteristics of debris from Nd:YAG LPP and CO 2 LPP

To see how a sharp edge or an aperture affect light. To analyze single-slit diffraction and calculate the intensity of the light

Scanning Capacitance Microscopy Investigations of Focused Ion Beam Damage in Silicon

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Ray Optics. Lecture 23. Chapter 23. Physics II. Course website:

New Scatterometer for Spatial Distribution Measurements of Light Scattering from Materials

Lab Report: Optical Image Processing

Physics 309 Lab 3. where the small angle approximation has been used. This pattern has maxima at. Y Max. n L /d (2)

10.4 Interference in Thin Films

SUPPLEMENTARY INFORMATION

12X Zoom. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts.

UNDERSTANDING CALCULATION LEVEL AND ITERATIVE DECONVOLUTION

Experiment 8 Wave Optics

EMPIR Grant Agreement 14IND07 3D Stack

Progress of the Thomson Scattering Experiment on HSX

Surface and thickness measurement of a transparent film using wavelength scanning interferometry

Optical diffraction gratings embedded in BK-7 glass by low-density plasma formation using femtosecond laser

Multiple optical traps from a single laser beam using a mechanical element

Chapter 24. Wave Optics

MICROSPHERE DIMENSIONS USING 3D PROFILOMETRY

Ray Optics. Lecture 23. Chapter 34. Physics II. Course website:

CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR. John C. Fleming

13. Brewster angle measurement

AUTOFOCUS SENSORS & MICROSCOPY AUTOMATION IR LASER SCANNING CONFOCAL MICROSCOPE IRLC DEEP SEE. Now See Deeper than ever before

Chapter 8: Physical Optics

Transcription:

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS Satoru Takahashi 1, Takashi Miyoshi 1, Yasuhiro Takaya 1, and Takahiro Abe 2 1 Department of Mechanical Engineering and Systems, Osaka University 2-1, Yamadaoka, Suita, Osaka 565-871, Japan 2 Seiko Epson Corporation 3-3-5, Yamato, Suwa, Nagano 392-852, Japan Abstract: This paper presents new optical measurement method for evaluating the microdefects on a silicon wafer surface using annular illumination based on the Fourier transform optics with crossed nicols. In order to verify a feasibility of this new measurement technique, the basic experiments are carried out by measuring the various types of Si wafer surface defects such as microscratches, particulate contaminations, COP (Crystal Originated Particle) [1], etc. All defects employed in this experiment are identified by making the use of AFM (Atomic Force Microscope) and SEM (Scanning Electron Microscope). Then it is found that microscratches induced in the CMP (Chemical Mechanical Polishing) processes with the depth of only 1nm can be detected by this method independent of their directions. And another result is also presented that the proposed method enables to clearly discriminate the defect types by combining with the normal illumination. Key words: laser applied measurement, surface inspection, silicon wafer, surface defects 1. INTRODUCTION In modern semiconductor technology, the reduction of the density of Si wafer surface defects that may decrease device yield has become an important issue. In order to fabricate the semiconductor device with high reliability, it is necessary to measure directly them during processing and control the fabrication process. The light scattering methods[2-4] based on the total integrated scatter (TIS) using oblique illumination are very often used for the inspection of Si wafer surface texture. However these optical measurement methods have the following disadvantages: (1) It is difficult to sensitively detect the oriented defects such as microscratches due to oblique illumination from one direction, because the oriented defects preferentially scatter perpendicular to their long dimension. The microscratches will be more important in CMP (Chemical Mechanical Polishing) processes and may be main yield-limiting in the next VLSI generation. (2) It is hard to discriminate the different types of defects due to intensity detection of scattered light. Defect types for Si wafer surface are classified two types such as contaminant defects on the surface and pit defects at the surface. The contaminant defects mean particulate contaminants, film contaminants and so on, which are on the surface. And the pit defects do COP (Crystal Originated Particle) [1], microscratches, and so on, which are surface-breaking defects. And the wafer manufactures strongly need to classify into two types of contaminant defects and pit defects, because the strategy on management of yield is dependent on their defect types. These disadvantages are great trouble to achieve the yield enhancement of VLSI in next generation. Therefore, the purpose of this study is to develop a new optical measurement technique resolving the above disadvantages, which can detect the microscratch with the depth of 1 nanometer scale and can discriminate the different types of Si wafer surface defects such as contaminant defects or

pit defects. 2. PRINCIPLE OF MEASUREMENT The normal configuration of optical microdefect detection widely used as commercial instruments is illustrated in Fig. 1. The laser beam is obliquely illuminated to the work surface from one direction. The incident angle is usually near to 7 degree. The several detectors are placed at arbitrary angle except specular direction to pick up the scattered light of the defect surface. In this optical configuration, when there exists no defect on the silicon wafer surface, the detectors do not get any output about the scattered light because the scatter is confined to a small angle around the specular Incident laser beam I 3 D3 Scattered light Stronger scattered light Oriented microdefect Perpendicular geometry Higher sensitivity I 2 D2 Detector D1 Microdefect Output I 1 Specular reflection Weaker scattered light Oriented microdefect Parallel geometry Lower sensitivity Fig. 1 Normal configuration of optical microdefect detection direction. On the contrary, if there exists any defect on the surface, the scatter results from the defect at wide angle and the detectors pick up some of the scattered light as shown at the top of Fig. 1. The sizes and the types of the microdefects are estimated from the detected intensity value of I 1, I 2 and I 3, namely the sum of the ratio of I 1, I 2 and I 3, the difference between I 1, I 2 and I 3, the ratio of I 1 or I 3 to I 2 and so on. This optical arrangement is equivalent to dark field optical system based on far field optics, however, it is difficult to sensitively detect the oriented microdefects such scratches due to oblique illumination from one direction as shown at the bottom of Fig. 1. In order to overcome this major disadvantage, we proposed a new optical measurement method, which can be applied to the oriented microdefects independent of their directions with high sensitivity. Fig. 2 shows the principle of our proposed measurement technique, which is based on the annular illumination and the Fourier transform optical system with crossed nicols. And this measurement technique is expected to have the following characteristics. (A) Annular illumination for oriented microdefects Oriented microdefect (A) Si wafer Annular illumination Laser Scattered Defect Pattern (LSDP) with Annular incident beam Scattered light Detection of microdefects Annular converging incident beam (36-degree incident illumination) (B) Crossed nicols (B) Crossed nicols configuration for high sensitivity detection Polarizer Plane-polarized annular incident beam Plane-polarized annular converging incident beam Annular incident beam Half mirror Si wafer Microdefect Laser Scattered Defect Pattern (LSDP) Analyzer Depolarized light consisting mainly of scattered light by the defect Polarized light consisting mainly of reflected light from the surface enables to detect the micodefect with high sensitivity independent of its direction CCD area sensor at Fourier plane Fig. 2 Principle of measurement based on annular illumination with crossed nicols

Polarization maintaining optical fiber Lens2 Collimating lens Lens1 (B) Analyzer High-sensitive cooled CCD area sensor (B) Polarizer (A) Annular beam transparency filter Power monitor Power meter X Polarizing state Z Half mirror Y d 1 XY - coarse positioning unit f f - df d 1 + d 2 = f 1 d 2 f 1 XY - fine positioning unit with stepping motor f = 1. f 1 = 6 f 2 = 15 f 2 High-power objective (2x) Silicon wafer f 2 Analyzing state Closed-loop position control system Z - Piezoelectric translator Ar + laser Digital CCD driver Personal computer GPIB interface Stage controller Monitor TV Fig. 3 Schematic diagram of silicon wafer surface defects measurement system (1) The annular illumination generated by the high power objective, in which the Si wafer surface is obliquely illuminated from every direction, enables the oriented defects to be detected high sensitively independent of their directions(fig. 2(A)). And the light polarizers arranged in the crossed nicols plays an extremely important role in enhancing sensitivity(fig. 2(B)). (2) As shown in Fig. 2(A)(B), since this optical measurement method detects scattering light intensity patterns of the defects (called Laser Scattered Defect Pattern (LSDP) [5,6]), which are generated based on the Fourier transform optics with crossed nicols, it is possible not only to detect the defects but also to discriminate the different types of ones such as contaminant defects or pit defects. Optical microscope image AFM image Printer 3. MEASUREMENT SYSTEM Fig. 3 shows the schematic diagram of silicon wafer surface defects measurement system based on the measurement principle mentioned above. An Ar + laser of wavelength 488.nm is used as the light source. After passing through the single-mode optical fiber (mode field diameter = 4.µm), the beam is collimated and polarized. This polarized Gaussian beam is converted into annular incident beam by passing the transparency filter made of the glass plate with the inside Cr coat (the diameter of Cr coat is taken 12µm). The annular light beam focused by the high-power objective (with the numerical aperture of.95) is illuminated on the silicon wafer surface with the beam spot of about 1µm. These configurations enable the annular oblique illumination with the average incident angle of 68 degree (from 63 degree to 72 degree). Width :.2 µm Length : 5 µm 2µm Depth :.5 µm Fig. 4 Sample microgroove fabricated by FIB machining used in basic experiment (a) (b) Fig. 5 Intensity pattern detected by Fourier transform optical system (a) Reference pattern from smooth surface (b) LSDP detecting the microgroove

4.5 µm A' Intensity of scattering pattern nm 2. -2. A 3 µm Beam spot Depth : 9 nm : 9 nm Scanning direction 2. 4. 6. µm 8. 2. 4. 6. 8. Fig. 6 AFM image of process inducing microscratch used in experiment µm Intensity of scattering pattern a.u. 1. 4.5µm.99.98.97.96.95 5 1 15 Scanning distance of beam spot µm Fig. 7 Intensity variations of scattering patterns obtained from scanning experiments 2 The annular oblique beam spot is relatively scanned over the silicon wafer surface by the computer controlled xy-stage. The scattered light resulting from a microdefect within the annular oblique beam spot travels through the objective and the relay lens, and then forms LSDP corresponding to a Fourier transform image on the high sensitivity cooled CCD area sensor. The intensity distributions are converted to 12 bit digital image data and stored in the image memory. 4. EXPERIMENTAL RESULTS 4.1 Basic experiment for microgroove detection In order to investigate the basic properties of this optical measurement method, primarily, experiments for detecting microgroove were carried out. Fig. 4 shows the optical and atomic force microscope image of the sample microgroove, whose size is.2µm wide, 5µm long and.5µm deep, which is fabricated as a typical oriented microdefect by FIB (Focused Ion Beam) machining. First, the intensity pattern of the smooth surface without any microdefects is detected as a reference one which is dark in the center part as seen in Fig. 5(a). Next, the defect pattern scattered from the microgroove is detected. Fig. 5(b) shows the defect pattern from the microgroove obtained as LSDP in Fourier transform optical system. As shown in LSDP of microgroove, a clear fringe image can be seen at the dark area in the intensity pattern. This fact means that a scattered light from the microdefect can be detect by this proposed optical system. 4.2 Scanning experiment for detection of microscratches induced in the CMP processes Based on the basic experiment mentioned above, the scanning experiment for detecting the actual microscratches induced in the CMP (Chemical Mechanical Polishing) processes was performed by measuring the intensity variations of the scattering patterns. Fig. 6 shows the AFM image of the microscratches employed in this experiment, whose depth is only 9nm. Fig. 7 shows the intensity variations of the scattering pattern vs. the scanning distance of the annular oblique beam spot. In this experiment, the intensity of scattering pattern means the scattered light intensity monitored at the dark area of intensity pattern as shown at the top of this figure. This graph shows that the

Annular Oblique illumination Contaminant defect Intensity_oblique (Io) Scattered light collected by the objective Pit defect Intensity_oblique (Io) Normal illumination Scattered light Intensity_normal Oblique illumination (In) Scattered light collected by the objective Intensity_normal Weak scattered light (In) Scattered light Normal illumination light >> Discrimination factor (Io / In) (Io / In) Fig. 8 Concept of defect type discrimination intensity rapidly increases at the scanning distance of about 8µm and repeats up and down several times until about 12µm. The scanning range of about 4.5µm indicating the high intensity is equal to the horizontal size of microscratches area. This experimental results suggest that the proposed method can detect the oriented microdefects such as the microscratches induced in the CMP processes independent of their directions with the depth of 1 nanometer scale. 5. DISCUSSION OF DEFECT TYPE DISCRIMINATION IN COMBINATION WITH NORMAL ILLUMINATION It is known that there is the difference between contaminant defects and pit defects coming from their responses to normal and oblique illumination. That is, in normal incidence, the scatter light from a pit defect is almost the same intensity as that from a contaminant defect, however, in oblique incidence, the scatter light from a pit defect becomes much smaller than that from a contaminant defect.fig. 8 indicates the concept of defect type discrimination based on this characteristics using our proposed optical system. Here, in order to prevent the effect of absolute scattered intensity value dependent of defect sizes, normal illumination is combined with the annular oblique illumination mentioned before. And the ratio of scattered intensity at oblique illumination to one at normal illumination, Io/In, is employed as discrimination factor of the defect types In order to verify a feasibility of this concept, the defect type discrimination experiments were Scattered Table1 Microdefects employed in the defect type discrimination experiment T y p e Microscope image Contaminant defects Pit defects Standard particle Particulate conataminant Film contaminant FIB fabricating pit COP defect Microscratch SEM image AFM image AFM image AFM image AFM image AFM image 1µm 1µm.5µm 1µm 2nm 1µm Horizontal size Vertical size.21µm.28 x.31µm.21µm (Diameter) 91nm (Height).66 x.9µm.8 x 1.µm.15 x.2µm 11nm (Height) 65nm (Depth) 131nm (Depth) 4.5 x 3.µm 5nm (Depth)

carried out by measuring the various kinds of Si wafer surface defects such as microscratches, particulate contaminants, film contaminants, COP, etc. All defects employed in this experiment are identified by making the use of AFM (Atomic Force Microscope) and SEM (Scanning Electron Microscope) as shown in Table 1. Fig. 9 shows the discrimination factor Io/In measured by each defect. The defect types, namely whether a contaminant defects or a pit defects, were clearly classified by the value Io/In in spite of various different kinds of defects. 6. CONCLUSIONS In order to verify a feasibility of new optical Si surface defect measurement technique Fig. 9 Relationship between defect type and discrimination factor using annular illumination based on the Fourier transform optics with crossed nicols, the several basic experiments were carried. The results obtained in this paper are summarized as follows; 1. The microscratches induced in the CMP (Chemical Mechanical Polishing) process with the depth of only 1nm can be detected by the proposed method independent of their directions. 2. The proposed method enables to classify the various difference kinds of defects into two types of the contaminant defect and the pit defect by LSDP in combining with the normal illumination. REFERENCES [1] J. Ryuta, E. Morita, T. Tanaka, and Y. Shimanuki: Jpn. J. Appl. Phys., 29/11(199)1947. [2] B. R. Locke and R. P. Donovan: J. Electronchem. Soc., 134/7(1987)1763. [3] Thomas A. Germer: Appl. Opt., 36/33(1997)8798. [4] Yu. Eremin and N. Orlov: Appl. Opt., 35/33(1996)6599 [5] S. Takahashi, T. Miyoshi, Y. Takaya, and K. Saito: Annals of the CIRP, 47/1(1998)459. [6] T. Miyoshi, S. Takahashi, Y. Takaya, and S. Shimada: Annals of the CIRP, 5/1(21)389. Discrimination factor Io / In 9 8 7 6 5 4 3 2 1 Particulate contaminant A Film contaminant Contaminant defects Particulate contaminant B Pit defects Contaminant defects PSL standard particle Particulate contaminant C Pit defects FIB fabricating pit COP A COP B Microscratch