Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

Similar documents
Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Adapter Module

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Do Not Copy. Important User Information For More Information... 3

1769 Compact I/O Communication Bus Expansion Cables

SLC Point Analog Output Module

SLC 500 Analog I/O Modules

Installation Instructions

Installation Instructions

MicroLogix 1762-OB16 Solid State 24V dc Source Output Module

Compact I/O DeviceNet Scanner Module

MicroLogix 1200 Isolated Relay Output Module

Compact 120V ac Input Module

Compact 1769-IF4 (Series B or Later) Analog Input Module

SLC 500 BASIC and BASIC-T Modules

Compact 16-Point 100 to 240V ac Solid State Output Module

MicroLogix Analog Input/Output Module

Compact Individually Isolated AC/DC Relay Output Module


ControlLogix Redundant Power Supply Chassis Adapter Module

Compact 16-point 24V dc Sink/Source High-speed Input Module

Compact Solid State 24V dc Source, High Current Output Module

Compact 32-point Solid-state 24V dc Source Output Module

Compact I/O 1769-IT6 Thermocouple/mV Input Module

Digital I/O Modules. Installation Instructions. (Catalog Number 1746 Series)

Installation Guide. MicroLogix Combo Analog Input Module (Catalog Number 1762sc-IF4OF4) For Technical Support. Contents

Compact 32-point Solid-state 24V dc Source Output Module

Compact 32-point Solid-state 24V dc Sink Output Module

Installation Instructions

Connecting SLC Systems as Remote I/O to PLC-5 Processors

ControlLogix DC ( V) Electronically Fused Output Module

(Catalog Number 1747-SN) Product Data

ControlLogix DC (10-30V) Isolated Output Module

CompactLogix Controllers

PanelView Plus/VersaView CE Terminals and Display Modules

Compact I/O Analog Output Module

Allen-Bradley PL. ControlLogix Drive Module. Installation Instructions. (Catalog Numbers: 1756-DMD30 and 1756-DMF30)

FlexArmor 24V dc Sinking Input Modules

Compact Combination 24V dc Sink Input/Source Output BOOLEAN Control Module

Barrel Temperature Control Module

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

Digital ac/dc (24V) Input Module

Compact 1769-OF8C Analog Output Module

MicroLogix 1200 Isolated Relay Output Module

FLEX Ex Spring Clamp Terminal Base

Solid-State Output Module

24 Input/8 Output AC Block I/O Module

Compact 1769-OF4VI Isolated Analog Output Module

ArmorBlock MaXum 4 Output Module Series B

FLEX I/O EtherNet/IP Adapter Module

Compact 1769-OF4CI Isolated Analog Output Module

FLEX Integra 4 Input Module

SLC Channel Analog Output Modules

FLEX Integra 2 Input/2 Protected Output Module

Installation Instructions

ISE 021 S-DIAS Interface Module RS232 / RS485

ICA 012 S-DIAS Interface Module CAN

H704-42(H)(E), H704-42/1(H)(E)

Bulletin 2707 DTAM Plus Operator Interface Product Data

Compact Combination Fast Analog I/O Module

ControlNet PCI Communication Interface Card

ControlLogix Isolated Analog Voltage/Current Input Module

DataSite Natural Gas Flow Meter and Remote Terminal Unit

Throughout this manual we use notes to make you aware of safety considerations:

P3-08RTD Analog Input

PACSystems RX7i IC698CHS009/119

ArmorBlock MaXum 8 Input / 8 Output Module Series B

XM-124 Standard Dynamic Measurement Module

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

ControlLogix RTD Input Module

ControlLogix DeviceNet Scanner Module

InView Marquee Message Display

SLC 5/03 and SLC 5/04 Processors Firmware/Operating System Upgrade

SERVICE BULLETIN MAINTENANCE OF WAY EQUIPMENT

DeviceNet CompactPCI Communication Interface Card

AIC+ Advanced Interface Converter. Catalog Number 1761-NET-AIC. User Manual. Allen-Bradley Spares

Data Highway/Data Highway Plus Asynchronous Communication Interface Module, Series D

1 PORT HARDENED SERIAL SERVER

POINT I/O Source Input Module

Solar Combiner Enclosure

Installing the Panel. Installing the Panel

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

ControlLogix Thermocouple Input Module

Micro800 4 Ch Universal Thermistor Input Module (Catalog Number 2080sc-NTC)

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

POINT I/O Protected Output Module

Backup Scanner Module

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

PanelView Plus and PanelView Plus Compact 400 and 600 Terminals

ControlLogix DH-485 Communications Module

Anybus X-gateway USER MANUAL

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options.

Installation Instructions

InView Marquee Message Display

Installation Instructions

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

PLC Racks IC697CHS782/783

Digital ac/dc (24V) Input Module

POINT I/O 120/220V ac Output Module

Removable Terminal Block Specifications

Transcription:

Installation Instructions Remote I/O Scanner (Catalog Number 1747-SN) Inside...page Hazardous Location Considerations... 2 Environnements dangereux... 2 Overview... 3 Hardware Features... 4 Required Tools and Equipment... 6 Installation... 7 RIO Link Wiring... 8 Specifications... 10 For More Information... 11

2 Remote I/O Scanner Hazardous Location Considerations This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following WARNING statement applies to use in hazardous locations. WARNING! EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2. Do not replace components or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Do not connect or disconnect components unless power has been switched off or the area is known to be non-hazardous. All wiring must comply with N.E.C. article 501-4(b). Environnements dangereux Cet équipement est conçu pour être utilisé dans des environnements de Classe I, Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante s applique à une utilisation dans des environnements dangereux. WARNING! DANGER D EXPLOSION La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement de Classe I, Division 2. Ne pas remplacer de composants ou déconnecter l'équipement sans s'être assuré que l'alimentation est coupée. Ne pas connecter ou déconnecter des composants sans s'être assuré que l'alimentation est coupée.

Remote I/O Scanner 3 Overview The Remote I/O (RIO) Scanner, 1747-SN, enables communication between an SLC processor and remotely located 1746 I/O chassis and other RIO-compatible Allen-Bradley operator interface and control devices. The 1747-SN scanner communicates with remote devices using the A-B Remote I/O link. The RIO link consists of a single master (scanner) and multiple slaves (adapters). Communication between devices occurs over twisted-pair cable with the devices daisy-chained together. Maximum distance for remote communication is 3,048 m (10,000 ft.). The scanner is compatible with any standard RIO adapter device. The SLC processor transfers a maximum of 4 logical racks (32 input and 32 output image words) of discrete remote I/O data into the SLC input and output image files. You can adjust the size of the scanner image files during configuration of your SLC system so that the scanner only transfers the discrete I/O data required by your application program. The 1747-SN Series B or later RIO Scanner can be configured to transfer up to 64 words of data to a remote device via block transfer. Refer to publication 1747-6.6, Remote I/O Scanner User Manual, for information on configuration, programming, and block transfers. The SLC 500 processor (SLC 5/02 or higher) supports multiple scanners in its local I/O chassis. The maximum number is dependent on the following: backplane power requirements (power supply dependent) SLC 500 processor I/O data table limit (4,096 input and output bits) processor memory to support the application (SLC processor dependent) SLC 5/02 or later processor RIO Scanner (Master of the RIO Link) 1747-ASB Module (Adapter/Slave) Remote Chassis Remote Expansion Chassis Local SLC Chassis Dataliner Message Display (Adapter/Slave) PanelView Operator Terminal (Adapter/Slave) Redi PANEL (Adapter/Slave)

4 Remote I/O Scanner Hardware Features The figure below shows the scanner s features. RIO Link Connector, Status LED, and DIP Switch information follows. SERIAL NO. FAC CAT SER SLC 500 Remote I/O Scanner SCANNER COMM FAULT SW1 O 1 2 N Status LEDs MADE IN U.S.A. B OPERATING LISTED IND. CONT. EQ. UL FOR HAZ. LOC. A196 SA TEMPERATURE CODE T3C CLASS I, GROUPS A, B, C, AND D, DIV 2 CURRENT REQUIREMENT 600 ma @ 5VDC HOST FRN PLUG FRN 1 2 KBAUD ON ON 57.6 ON OFF 115.2 OFF ON 230.4 OFF OFF 230.4 CONNECT ONE END OF CABLE SHIELD TO CHASSIS MOUNTING BOLT. REFER TO USERS MANUAL. Line 1 Shield Line 2 1747-SN O 1 2 N Dip Switch Cable Tie Slots RIO Link Connector RIO Link Connector This 3-pin male connector connects the scanner to the RIO link. The Allen-Bradley replacement part number is 1746-RT29. Status LEDs The scanner has two LEDs, FAULT and COMM, which indicate its operating status. FAULT LED - indicates the scanner s overall status. The red FAULT LED is off whenever the scanner is configured and operating properly. COMM LED - allows you to monitor communication with all configured devices. This LED is green once the scanner is in the Run mode. It is red if a hardware fault is detected. The COMM LED status information is valid only when the FAULT LED is off.

Remote I/O Scanner 5 The table below explains the scanner and communication status as indicated by the FAULT and COMM LEDs. FAULT LED COMM LED Status Information Flashing Red Not applicable Scanner configuration error. No RIO link communication attempted. Duplicate scanner detected on RIO link. Red Not applicable Major fault on scanner. No RIO link communication attempted. Off Red Hardware fault detected. Off Off Scanner is operating properly. Scanner is offline (no RIO link communication attempted). Off Green Scanner is operating properly. Scanner is online (active communication established with all devices). Off Flashing Green Scanner is operating properly. At least one configured RIO link device is not communicating. Off Flashing Red Scanner is operating properly. None of the configured RIO link devices are communicating.

6 Remote I/O Scanner Baud Rate DIP Switch The figure below shows the location of the DIP switch and the DIP switch settings for the supported baud rates. IMPORTANT For proper system operation, the baud rate of all devices on the RIO link must be the same. 12 12 12 12 O O O O N N N N 57.6K baud 115.2K baud 230.4K baud 230.4K baud Required Tools and Equipment Have the following tools and equipment ready: medium blade screwdriver termination kit (the package, containing resistors and a ring lug, which was included with the scanner) approximately 38 cm (15 inches) of #20 AWG wire for grounding the drain shield to the SLC chassis (for Series A retrofits) adequate length of RIO communication cable (Belden 9463) for your specific application

Remote I/O Scanner 7 Installation ATTENTION! Before installation, make sure that your modular SLC power supply has adequate reserve current capacity. The scanner requires 600 ma at 5V dc. Make sure you have set the DIP switch properly before installing the scanner. IMPORTANT Before installation, make sure that your modular SLC power supply has adequate reserve current capacity. The scanner requires 600 ma at 5V dc. Insertion Module Release Card Guide Cable Tie 1. Disconnect power. 2. Align the full-sized circuit board with the chassis card guides. The first slot (slot 0) of the first rack is reserved for the SLC 500 processor. 3. Slide the module into the chassis until the top and bottom latches catch.

8 Remote I/O Scanner 4. Attach the RIO link cable to the connector on the front of the module, behind the door. Ground the cable s shield wire to a chassis mounting bracket. Refer to the RIO link wiring illustration on page 9. 5. Insert the cable tie in the slots. 6. Route the cable down and away from module, securing it with the cable tie. 7. Cover all unused slots with the Card Slot Filler, Catalog Number 1746-N2. Removal 1. Disconnect power. 2. Remove all cabling. 3. Press the releases at the top and bottom of the module and slide the module out of the chassis slot. 4. Cover all unused slots with the Card Slot Filler, Catalog Number 1746-N2. RIO Link Wiring The scanner is connected to other devices on the RIO link in a daisy chain (serial) configuration. There are no restrictions governing the space between each device, provided the maximum cable distance (Belden 9463) is not exceeded. A 1/2 watt terminating resistor (included with the module) must be attached across line 1 and line 2 of the connectors at each end (scanner and last physical device) of the RIO link. The size of the resistor depends on the baud rate and extended node capability, as shown in the table below. Note: To use extended node, all devices on the RIO link must support it. Refer to each device s user manual. Using Extended Node Capability Not Using Extended Node Capability Baud Rate Max. Cable Distance (Belden 9463) Resistor Size 57.6K baud 3048 m (10,000 ft.) 82Ω 1/2 Watt 115.2K baud 1524 m (5,000 ft.) Gray-Red-Black-Gold 230.4K baud 762 m (2,500 ft.) 57.6K baud 3048 m (10,000 ft.) 150Ω 1/2 Watt 115.2K baud 1524 m (5,000 ft.) Brown-Green-Brown-Gold 230.4K baud 762 m (2,500 ft.) 82Ω 1/2 Watt Gray-Red-Black-Gold

Remote I/O Scanner 9 RIO Scanner Terminating Resistor Last Physical Device End RIO Link Connector RIO Link Connector Terminating Resistor Scanner End Chassis Mounting Bracket Shield Drain Wire Ring Lug (For Series A Retrofits) Shield Drain Wire (For New Series B Installations) For New Installations To ensure a proper earth ground of the cable shield, follow these steps: 1. While the RIO link connector is plugged into the scanner and lines 1 and 2 are connected, strip the cable back to expose enough shield drain wire to reach a chassis mounting bracket. 2. Attach the ring terminal lug (supplied) to the end of the shield drain wire. 3. Attach the ring terminal lug to the SLC chassis mounting bracket. Note that for new installations the middle (shield) terminal is not used when connecting to the scanner. IMPORTANT The RIO cable shield must be grounded at the scanner end only.

10 Remote I/O Scanner For Series A Scanner Retrofits Refer to the illustration on page 9. To eliminate the need to strip the cable back, follow these steps: 1. Attach the shield wire and a short piece of #20 AWG wire (dotted line) to the shield lug of the RIO link connector. 2. Attach the other end of the #20 AWG wire to the ring terminal lug. 3. Attach the ring terminal lug to a chassis mounting bracket. IMPORTANT The RIO cable shield must be grounded at the scanner end only. Ensure that the unshielded portion of the link communication wire (blue and clear) is as short as possible. Specifications Backplane Current Consumption Operating Temperature Storage Temperature Humidity 600 ma at 5V dc 0 C to +60 C (+32 F to +140 F) -40 C to +85 C (-40 F to +185 F) 5 to 95% without condensation Noise Immunity NEMA Standard ICS 2-230 Agency Certification UL listed / CSA Certified Class I, Division 2, Groups A,B, C, D CE marked for all applicable directives

Remote I/O Scanner 11 For More Information For Refer to this Document Pub. No. A more detailed description on how to install, configure, and operate your Remote I/O Scanner. A more detailed description on how to install and use your modular SLC 500 system A reference manual that contains status file data and instruction set information for SLC 500 processors. If you would like a manual you can: download a free electronic version from the internet: www.theautomationbookstore.com purchase a printed manual by: Remote I/O Scanner User Manual SLC 500 Modular Hardware Style Installation and Operation Manual SLC 500 and MicroLogix 1000 Instruction Set Reference Manual 1747-6.6 1747-6.2 1747-6.15 contacting your local distributor or Rockwell Automation representative visiting www.theautomationbookstore.com and placing your order calling 1.800.963.9548 (USA/Canada) or 001.330.725.1574 (Outside USA/Canada

SLC 500, PanelView, RediPANEL, and Dataliner are trademarks of Rockwell Automation, Inc. Belden is a trademark of Belden, Inc. Supersedes Publication 1747-5.33 - October 1999 PN 40071-038-01(B) 2001 Rockwell International Corporation. Printed in the U.S.A.