4140XMPT2 PROGRAMMING FORM

Similar documents
*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

VISTA-50P VISTA-50PUL

VISTA-128BP/VISTA-250BP Programming Form

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

CUSTOMER INFORMATION

Ademco/Protection One 250P1-1 Programming Form

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

First Alert FA160C/162C Installer Notes M. Leuck

Property of Monitronics Inc

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

Property of Monitronics Inc

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

Ademco Vista-20SE/First Alert FA-162C Program Sheet

Property of Monitronics Inc

VISTA-50PADT VISTA-50PADTUL

Property of Monitronics Inc

ADEMCO VISTA-48A Security Systems

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

Programming Default Tables

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

High Security and Access System EVO48 V2.1 EVO192 V2.1

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Series. NX-8-EUR Control Panel. Installation manual

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

ADEMCO LYNXR-ENSIA Security System

Lynx Plus Security System

APX32EN Security Systems

Programming Worksheets

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

PROGRAMMING HELP GUIDE

Includes: 413oxM 513oxM 414oxM 414oxMP

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

2 IDS LCD Keypad User Manual C Issued March 2009

Digiplex EVO High Security and Access System What s New EVO192 V2.7

R A D I O N I C S. D7212B Control/Communicator Program Entry Guide C 9/95

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Modules Programming Guide

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

EVOHD. Programming Guide. Version

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

GEM-P9600 CONTROL PANEL/COMMUNICATOR

Control Panel Solution 2000 / 3000

Important Notice. Customer Information. 2 WisDom User Manual

Installation Instructions

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Modules Programming Guide. paradox.com

IDS X-Series User Manual E Issued June 2013

NetworX Series NX-8V2 Control Panel Installation and Startup

MG/SP Series (V4.9/V5.1) What s New

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

D1260/D1260B. Owner's Manual. Keypad

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

VISTA-120. Installation and Setup Guide. Partitioned Security System with Scheduling. N5944-8V1 Rev. B 6/99

NX-148 LCD KEYPAD INSTALLATION MANUAL

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

(To modify t he installer code, ref er to section [ 1000], Installer Code Programming on page 21) 1234 or

SOFTWARE VERSION 3.10

Security System. Owner s Manual

SOFTWARE VERSION 3.20

Solution 16 plus. User Guide Security System

Emergency Dialer DIAL-ALERT MODEL: AD-105.

DSC programming for the Alexor and Impassa

Ademco Group Compass Network Downloader

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

INT-KSG Keypad Quick user s guide

INT-KSG Keypad Quick user s guide

LCD User Station User Manual

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

FPD-7024 Fire Alarm Control Panel Version 1.03

INT-TSI Brief User Manual

SECURITY MODULE CG3 User Manual

SOFTWARE VERSION 3.10

Control Panels D9412GV4/D7412GV4. en Owner's Manual

Control Panel D9124. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.

Telephone and Reporting Setup in ElkRP

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

Control Panel D9112. Release Notes for Version 7.00 March Introduction. 2.0 Requirements. 4.0 Previous Version 6.

Colour Graphic Terminal User Manual. Rev 3.1

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

Transcription:

414XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown in brackets [ ], otherwise default =. Fields bordered by dotted line can be programmed using the #93 Menu mode. * INSTALLER CODE 4 1 4 Enter 4 digits, -9 [414] ASSIGN RESPONSE TYPE FOR ZONES 1-27, 95-99 (Enter -1) see fields 1*1-1*9 for response types for zones 28-87. *2 *3 *4 *5 1 9 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 1 3 11 3 12 3 13 3 14 3 15 3 16 3 17 18 19 2 21 22 23 24 25 26 27 Not Used 97 Polling Loop Short 95 9 (1+*/A) 96 8 (3+#/C) 99 7 (*+#/B) RESPONSE TYPES: = Disabled zone 1 = ENTRY/EXIT #1 2 = ENTRY/EXIT #2 3 = PERIMETER 4 = INTERIOR, FOLLOWER 5 = DAY/NIGHT 6 = 24-HOUR SILENT ALARM 7 = 24-HOUR AUDIBLE ALARM 8 = 24-HOUR AUXILIARY 9 = FIRE 1 = INTERIOR, DELAY 2 = ARM STAY 21 = ARM AWAY 22 = DISARM 23 = NO ALARM RESPONSE *9 ENTRY DELAY #1 Partition-Specific *1 EXIT DELAY #1 Partition-Specific *11 ENTRY DELAY #2 Partition-Specific *12 EXIT DELAY #2 Partition-Specific *13 ALARM SOUNDER DURATION Partition-Specific *14 ZONE 9 FAST/SLOW RESPONSE [=Slow]; 1=Fast "" for UL. *15 KEYSWITCH ASSIGNMENT Enter partition in which keyswitch used, 1-8; [ = Disable] *16 CONFIRMATION OF ARMING DING Partition-Specific *17 AC POWER LOSS SOUNDING 1 = yes; [ = no] *18 AC POWER LOSS ALARM 1=Yes;[=No] *19 AC RANDOMIZE 1=Randomize 1-4 min.;[=no] *21 DISABLE FIRE TIME-OUT 1=No timeout [=Fire time-out] *22 CONSOLE PANIC ENABLES Partition-Specific *23 MULTIPLE ALARMS Partition-Specific *24 EXPANSION ZONE (RF,RPM) TAMPER DISABLE 1=yes; [=enable for RF and RPMs] *25 BURGLARY TRIGGER 1 FOR ZONE RESPONSE TYPE 8 =enable; [1=disable] *26 INTELLIGENT TEST REPORTING Set "" for UL 1 1=Yes, (No report sent if any other report was recently sent); [=No] *27 TEST REPORT INTERVAL 2 4 Enter interval in hours, 1-199; =No report [24]; Max. 24 for UL. *28 POWER UP IN PREVIOUS STATE [1=Yes]; =No; "1" for UL 1 *29 QUICK ARM Partition-Specific *3 TOUCH TONE OR ROTARY DIAL 1 1=Touchtone; [=Rotary]; See field 1*33 for Touch-tone w/rotary backup *31 PABX ACCESS CODE -9; * = 14; # = 15 *32 PRIM. SBSCRBR ACCT# Partition-Specific *33 PRIMARY PHONE NUMBER Enter -9 for each digit *34 SECONDARY PHONE NUMBER Enter -9 for each digit *35 DOWNLOAD PHONE No. 1 8 7 6 2 7 8 3 1 Enter -9 for each digit *36 DOWNLOAD ID No. 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 Enter -9; A-F (1-15) [15 15 15 15 15 15 15 15] *37 DOWNLOAD COMMAND ENABLES 1 1 1 1 1 1 1 Dialer System Not Remote Remote Remote Upload Download Program Shutdown Shutdown Used Bypass Disarm Arm Program See 1*53 for Callback disable option. [1=Enable]; =Disable For UL installations, All options must be disabled. *38 INHIBIT BYPASS OF A ZONE Partition-Specific *39 OPEN/CLOSE REPORT FOR INSTALLER Partition-Specific *4 OPEN/CLOSE REPORTING FOR KEYSWITCH 1=Yes; [=No] *41 EOLR DISABLE (Zones 2-8) [1=N.C. Loops]; =EOLR supervision; Must be "" for UL. 1 *42 DIAL TONE PAUSE [=5 seconds]; 1=11 seconds; 2=3 seconds; * for UL *43 DIAL TONE DETECTION [1=wait for dial tone]; =pause then dial 1 *44 RING DETECTION COUNT 1-14; 15=answering machine; [=no detection] 1 5 *45 PRIMARY FORMAT [= Low Speed]; 1=Contact ID; 2=ADEMCO High Speed; 1 3=ADEMCO Express *46 LOW SPEED FORMAT (Primary) [=ADEMCO Low Speed]; 1=Sescoa/Radionics *47 SECONDARY FORMAT [=Low Speed]; 1=Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express *48 LOW SPEED FORMAT (Secondary) [=Ademco Low Speed]; 1=Sescoa/Radionics *49 CHECKSUM VERIFICATION 1=Yes; [=No] Primary Scndry *5 SESCOA/RADIONICS SELECT 1=Sescoa; [=Radionics] *51 DUAL REPORTING 1=Yes; [=No] If used with Split Reporting "1" option(1*34), alarms go to both primary and secondary numbers, while all other reports go to secondary only. if used with Split Reporting "2" option, open/close and test messages go to both lines, while all other reports go to primary. -1-414XMPT2-11+

*52 STANDARD/EXPANDED REPORT FOR PRIMARY Alarm Rstr Bypass Trbl Opn/Cls Low Bat [=Standard]; 1=expanded; Note: Expanded overrides 4+2 format. *53 STANDARD/EXPANDED REPORT FOR SECONDARY Alarm Rstr Bypass Trbl Opn/Cls Low Bat [=Standard]; 1=expanded; Note: Expanded overrides 4+2 format. ALARM REPORT CODE & ID DIGITS FOR ZONES 1-32 & SUPERVISORY & RESTORE CODES [All codes default to ] *54Code*55ID *56Code *57ID *58 *59Code *6ID *61Code *62ID *63 1 1 9 1 Alarm Rst. 17 25 2 2 1 2 Trouble 18 26 3 3 11 3 Trouble Rst. 19 27 4 5 12 4 Bypass 2 28 5 6 13 5 Bypass Rst. 21 29 6 7 14 6 22 3 7 8 15 7 23 31 8 9 16 8 24 32 ALARM REPORT CODE & ID DIGITS FOR ZONES 33-64 & SUPERVISORY & RESTORE CODES [All codes default to ] *64Code*65ID *66Code *67ID *68 *69Code *7ID *71Code *72ID *73 33 41 Alarm Rst. 49 57 34 42 Trouble 5 58 35 43 Trouble Rst. 51 59 36 44 Bypass 52 6 37 45 Bypass Rst. 53 61 38 46 54 62 39 47 55 63 4 48 56 64 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. ALARM REPORT CODE & ID DIGITS FOR ZONES 81-87, RF RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES [All codes default to ] *74Code*75ID 81 82 83 84 85 86 87 88 *76Code *77ID 89 9 91 Duress 1 97 95 1 96 1 99 1 *78 (1 + */A) (3 + #/C) (* + #/B) NOTES: 97 = Poll Loop Short; 88 & 9= RCVR not receiving transmitter signals. 89 & 91= RCVR not responding, bad conn. to panel. 87 = Voice Module supervision. *79 ZONE TYPE RESTORE for TYPES 1-8 1=Enable; [=Disable] 1 2 3 4 5 6 7 8 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. *8 ZONE TYPE RESTORE for TYPES 9 & 1 1 1=Enable; [=Disable] 9 1 SYSTEM NON-ALARM CODES *81 *82 First Digit Second Digit Close Open Low Battery Low Bat Res. AC Loss AC Restore Test Power Cancel Prog. tamper 1 2 Second digit of each applies only to 4+2 or expanded (fields *52 & *53) formats *83 FIRST TEST REPORT TIME 1 2 [Day; hour 12; min ] Days 1-7 Hours -23 Min -59; in all boxes = instant (Day 1 = Monday) *84 SWINGER SUPPRESSION Partition-Specific *85 ENABLE DIALER REPORTS Partition-Specific FOR PANICS & DURESS *86 428 MODULE ZONE ASIGNMENT 1 = allows 8 zone numbers (1-17) on one module, but prevents any other polling loop expansion; [ = Otherwise] *87 ENTRY WARNING Partition-Specific *88 BURG. ALARM COMM. DELAY Partition-Specific *89 RESTORE REPORT TIMING [= instant, as zone restores]; 1=after bell timeout if zone restored; 2=when system is subsequently disarmed *9 SECONDARY SUBSCRIBER Partition-Specific ACCOUNT # -2-414XMPT2-11+

ASSIGN RESPONSE TYPES FOR ZONES (Enter -1; see Response Types below) 1*1 1*2 1*3 1*4 1*5 28 29 3 31 32 65 66 67 68 69 7 71 72 33 34 35 36 37 38 39 4 41 42 43 44 45 46 47 48 SECOND PAGE PROGRAMMING FIELDS (press *94) 49 5 51 52 53 54 55 56 1*6 1*7 1*8 1*9 73 81 74 82 75 83 76 84 77 85 78 86 79 87 8 88 2nd RCVR 57 58 59 6 61 62 63 64 89 2nd RCVR 9 1st RCVR 91 1st RCVR RESPONSE TYPES: Disabled zone 1 ENTRY/EXIT #1 2 ENTRY/EXIT #2 3 PERIMETER 4 INTERIOR, FOLLOWER 5 DAY/NIGHT 6 24-HOUR SILENT 7 24-HOUR AUDIBLE ALARM 8 24-HOUR AUXILIARY 9 FIRE 1 INTERIOR, DELAY 2 ARM STAY 21 ARM AWAY 22 = DISARM 23 = NO ALARM RESPONSE NOTES: If using 1 or 2 RF RCVRs, enable their respective faults (88-91) as troubles (type 5) to provide trouble annunciation. Enter if no annunciation is desired. 88 9 RCVR not receiving transmitter signals. 89 & 91 = RCVR not responding, bad conn. to panel. MISCELLANEOUS WIRELESS OPTIONS 1*26 FIRST 428 RF RECEIVER SELECT 1=Yes; [=No] 1*27 SECOND 428 RF RECEIVER SELECT 1=Yes; [=No] 1*28 RF TRANSMITTER LOW BATTERY ANNUNCIATION 1=Immediate; [=when disarmed]; Must be "1" for UL. 1*29 RF TRANSMITTER 1 LOW BATTERY REPORT ENABLE 1=Enable; [=Disable] Must be "1" for UL. 1*3 RF RECEIVER CHECK-IN INTERVAL 6 2-15 times 2 Hours; disables transmitter supervision Max. "6" (12 hr) for UL. 1*31 RF TRANSMITTER CHECK-IN INTERVAL 1 2 2-15 times 2 Hours; disables supervision [12] Max. "6" (12 hr) for UL. 1*32 RF RECEIVER TYPE 1 [ = 428]; 1 = 4281 (must have correct revision level); 2=5881 1*33 TOUCH-TONE W/ROTARY BACKUP ENABLE 1=Enable; [=Disable] 1*34 COMM. SPLIT REPORT SELECTION [=No]; 1=Alarms primary, others secondary; 2=Open/close, test secondary, others primary; See *51 for comments. ALARM REPORT CODE & ID DIGITS FOR ZONES 65-8 & SUPV. & RESTORE CODES [codes default to zero] 1*36ID 1*37Code 1*35Code 65 66 67 68 69 7 71 72 73 74 75 76 77 78 79 8 1*38ID 1*39 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. DIALER CODES (Armed Stay, Time Set & Event Logging) 1*4 1*41 First Digit Second Digit Armed Stay Time/Date set or event log reset Event log 5% & 9% full Event log overflow 1*43 ENABLE PERMANENT BACKLIGHT Partition-Specific 1*44 WIRELESS KEYPAD TAMPER DETECT ENABLE 1=Enable; [=Disable] 1*45 CONSOLE ANNUNCIATION Partition-Specific DURING EXIT DELAY 1*46 AUXILIARY OUTPUT ENABLE [=Ground start]; 1=Open/close trigger; 2=Console sounding; 1*47 CHIME ANNUNCIATION Partition-Specific ON EXTERNAL SIREN 1*48 WIRELESS KEYPAD ASSIGNMENT [=Disable]; enter partition in which RF keypad used, 1-8. 1*49 SUPRESS TROUBLE SOUNDER FOR RF SUPERVISION [1=Disable]; =Enable. Must be "" for UL. 1*52 CANCEL REPORT RESTRICTION Partition-Specific 1*53 DOWNLOAD CALLBACK 1 1=callback not required; [=callback required]; Must be "" for UL. 1*57 ENABLE 58 RF BUTTON GLOBAL ARM Enter "1" to have the system arm/disarm following the button user's global arm settings. Enter [""] if the button is not to be used to global arm the system. 1*58 ENABLE 58 RF BUTTON FORCE BYPASS Enter "1" to enable. If a zone is faulted after pressing button, console will beep once. User should press button again within 4 sec. to force bypass those zones. Enter [""] to disable. Must be disabled for UL Listed installations. 1*7 EVENT LOG TYPES 1 1 1 1 1 1 Enable logging; = Disable Alarm Check Bypass Opn/Cls System 1*71 12/24 HOUR TIME STAMP FORMAT [=12 hour]; 1=24 hour 1*72 EVENT LOG PRINTER ON-LINE [=Disable]; 1=Enable 1*73 PRINTER BAUD RATE [=12]; 1=3 1*74 RELAY TIMEOUT XX MINUTES [] 1 Enter the relay timeout, -127 in multiples of 2 minutes, desired for #8 Menu Mode time driven event relay command numbers "4/9" and #93 Menu Mode Relay Programming output command "56". 1*75 RELAY TIMEOUT YY SECONDS [] 1 Enter the relay timeout, -127 seconds, desired for #8 Menu Mode time driven event relay command numbers "5/1" and #93 Menu Mode Relay Programming command "57". 1*76 ACCESS CONTROL FOR PARTITIONS -3-414XMPT2-11+

2* NUMBER OF PARTITIONS 1 Enter [1] - 8 2*1 DAYLGHT SAVINGS TIME [4, 1] 4 1 START/END MONTH Start End -12; if no daylight savings time, enter, THIRD PAGE PROGRAMMING FIELDS (press *94) PARTITIONING SETUP FIELDS Refer to the PARTITION-SPECIFIC program fields for programming each partition's variable characteristics. 2*2 DAYLIGHT SAVINGS TIME [1, 5] 1 5 START/END WEEKEND# Start End Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=3rd from last [1,5; 1st Sunday in April, last in Oct.] 2*17 NUMBER OF CODES PER PARTITION Enter 1-99. Total must be less than or equal to 128. 1 9 9 [99] 2 1 [1] 3 1 [1] 4 1 [1] 5 1 [1] 6 1 [1] 7 1 [1] 8 1 [1] 2*5 AUTO-ARM DELAY Partition-Specific 2*6 AUTO-ARM WARNING PERIOD Partition-Specific 2*7 AUTO-DISARM DELAY Partition-Specific 2*8 ENABLE FORCE ARM FOR AUTO-ARM Partition-Specific 2*9 ENABLE OPEN/CLOSE REPORTS Partition-Specific BY EXCEPTION 2*1 ALLOW DISARMING ONLY DURING Partition-Specific ARMING/DISARMING WINDOWS 2*11 ALLOW DISARM OUTSIDE WINDOW [] IF ALARM OCCURS Used only if field 2*1 (partition-specific field) is set to "1". If this field is enabled ("1") the system can be disarmed outside the disarm window if an alarm has occurred. If "", disarming can only be done during the disarm window. If field 2*1 is set to "" for a partition, this field has no effect for that partition. SCHEDULING RELATED DIALER REPORTS 2*13 2*14 1st Digit 2nd Digit Early opening report code Early closing report code Late opening report code Late closing report code No opening (late to open) report code No closing (late to close) report code Auto-arm failure report code Access schedule changed report code 2*18 ENABLE GOTO Partition-Specific FOR THIS PARTITION 2*19 USE PARTITION DESCRIPTORS [=Disable]; 1=Enable 2*2 ENABLE J7 TRIGGERS Partition-Specific BY PARTITION 2*21 ENABLE SUPERVISION PULSES [] FOR LRR TRIGGER OUTPUTS F B S Used for supervised connection to 792SE. Enter "" to disable or "1" to enable the listed outputs. F=Fire; B=Burglary; S=Silent panic/duress SUMMARY OF PROGRAMMING COMMANDS To enter program mode, enter installer code + [8] + [] + []. Enter first field address to begin programming. To set standard defaults, press *97 To set communications defaults, press *94 + one of the following: *8=low speed; *81=Ademco Express; *82=Ademco High Speed; *83=Ademco's Contact ID To change to next page of program fields, press *94 To return to previous set of fields, press *99 To erase account & phone number field entries, press [*] + field number + [*] To assign zone descriptors, press *93 + follow menu prompts To add custom words, press *93 + follow menu prompts To enter Installer's Message, press *93 + follow menu prompts To exit program mode, press *99 OR *98: *99 allows re-access to programming mode by installer code. *98 prevents re-access to programming mode by installer code. -4-414XMPT2-11+

*8 OUTPUT RELAYS S T A R T S T O P RELAY ZONE ZONE TYPE PART. ZONE LIST ZONE TYPE PART. OUTPUT RSTRC ACTION EVENT LIST RELAY (A) (EV) (ZL) (ZT) (ZL) (ZT) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 Where: A = RELAY ACTION = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off EV = EVENT = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore ZL = ZONE LIST 1,2,3 or 4. = Not Used. START ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, relay action will START. STOP ZONE LIST: Upon restore of ALL zones on this list, relay action will STOP. It need not be same list as used for START. ZT = ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are: = No Response 6 = 24 Hr Silent Note: Any zone in "ZT" going into alarm, 1 = Entry/Exit 1 7 = 24 Hr Audible fault, or trouble will actuate relay. 2 = Entry/Exit 2 8 = 24 Hr Aux Any zone of that type that restores 3 = Perimeter 9 = Fire Alarm or Trouble will stop relay action. 4 = Interior Follower 1 = Interior w/delay 5 = Trouble Day/Alarm Night 23 = No Alarm Response Choices for System Operation are: 2 = Arming-Stay 38 = Chime 52 = Kissoff 21 = Arming-Away 39 = Any Fire Alarm 54 = Smoke Detector Reset 22 = Disarming (Code + OFF) 4 = Bypassing 55 = Disarm + 1 minute 31 = End of Exit Time 41 = AC Power Failure 56 = XX minutes (Enter XX in field 32 = Start of Entry Time 42 = System Battery Low 1*74; stop condition only) 33 = Any Burglary Alarm 43 = Communication Failure 57 = YY seconds (Enter YY in field 34 = Code + # + 7 + 1 Key Entry 44 = RF Low Battery 1*75; stop condition only) 35 = Code + # + 7 + 2 Key Entry 45 = Polling Loop Failure 58 = Duress 36 = At Bell Timeout** 47 = Console Failure 37 = 2 Times Bell Timeout** 51 = RF Receiver Failure **Or at Disarming, whichever occurs earlier. -5-414XMPT2-11+

*81 ZONE LISTS FOR OUTPUT RELAYS Record desired zone numbers. More or fewer boxes than shown may be needed, since any list may include any or all of system's zone numbers. Zone List 1: Started or stopped by zone numbers (enter to end entries). Zone List 2: Started or stopped by zone numbers (enter to end entries). Zone List 3: Started or stopped by zone numbers (enter to end entries). Zone List 4: Started or stopped by zone numbers (enter to end entries). Zone List 5: Started or stopped by zone numbers (enter to end entries). Zone List 6: Started or stopped by zone numbers (enter to end entries). Zone List 7: Started or stopped by zone numbers (enter to end entries). Zone List 8: Started or stopped by zone numbers (enter to end entries). -6-414XMPT2-11+

Device Assignments Device Addr Device Type Parameter 1 Value Parameter 2 Value Alpha Console Master Partition 1 Sounder Opt No suppression 1 Alpha Console Master Partition 1 Sounder Opt No suppression 2 Alpha Console Master Partition 1 Sounder Opt No suppression 3 Alpha Console Master Partition 1 Sounder Opt No suppression 4 Not Used N/A N/A N/A N/A 5 Not Used N/A N/A N/A N/A 6 Not Used N/A N/A N/A N/A 7 Not Used N/A N/A N/A N/A 8 Not Used N/A N/A N/A N/A 9 Not Used N/A N/A N/A N/A 1 Not Used N/A N/A N/A N/A 11 Not Used N/A N/A N/A N/A 12 Not Used N/A N/A N/A N/A 13 Not Used N/A N/A N/A N/A 14 Not Used N/A N/A N/A N/A 15 Not Used N/A N/A N/A N/A 16 Not Used N/A N/A N/A N/A 17 Not Used N/A N/A N/A N/A 18 Not Used N/A N/A N/A N/A 19 Not Used N/A N/A N/A N/A 2 Not Used N/A N/A N/A N/A 21 Not Used N/A N/A N/A N/A 22 Not Used N/A N/A N/A N/A 23 Not Used N/A N/A N/A N/A 24 Not Used N/A N/A N/A N/A 25 Not Used N/A N/A N/A N/A 26 Not Used N/A N/A N/A N/A 27 Not Used N/A N/A N/A N/A 28 Not Used N/A N/A N/A N/A 29 Not Used N/A N/A N/A N/A 3 Not Used N/A N/A N/A N/A -1-414XMPT2-11+

Time Windows No Time Windows Currently Set 414XMPT2-11+ GLOBAL SCHEDULING DATA Limitation of Access Schedules Schedule # 1 Schedule # 2 WNDW 1 WNDW 2 WNDW 1 WNDW 2 Monday Schedule # 3 WNDW 1 WNDW 2 Schedule # 4 WNDW 1 WNDW 2 Schedule # 5 WNDW 1 WNDW 2 Schedule # 6 WNDW 1 WNDW 2 Schedule # 7 WNDW 1 WNDW 2 Schedule # 8 WNDW 1 WNDW 2 Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Daylight Savings Time Selections Month Start April Sunday First Enable Disarming Outside Disarm Window End October Last Time Driven Events Active Days Time Activation Time EventDescription M T W R F S Su H Window w/in Time Window Action 1 -- 2 -- 3 -- 4 -- 5 -- 6 -- 7 -- 8 -- 9 -- 1 -- 11 -- 12 -- 13 -- 14 -- 15 -- 16 -- 17 -- 18 -- 19 -- 2 Global Scheduling --Data 414XMPT2-11+

414XMPT2-11+ GLOBAL SCHEDULING DATA Timer Output Programming Timer Device On Time Off Time Monday Tuesday Wednesday Thursday Friday Saturday Sunday Permanent 1 *** No Relay : AM : AM 2 *** No Relay : AM : AM 3 *** No Relay : AM : AM 4 *** No Relay : AM : AM 5 *** No Relay : AM : AM 6 *** No Relay : AM : AM 7 *** No Relay : AM : AM 8 *** No Relay : AM : AM 9 *** No Relay : AM : AM 1 *** No Relay : AM : AM 11 *** No Relay : AM : AM 12 *** No Relay : AM : AM 13 *** No Relay : AM : AM 14 *** No Relay : AM : AM 15 *** No Relay : AM : AM 16 *** No Relay : AM : AM 17 *** No Relay : AM : AM 18 *** No Relay : AM : AM 19 *** No Relay : AM : AM 2 *** No Relay : AM : AM Scheduling Related Dialer Reports 1st Digit 2nd Digit EARLY OPENING EARLY CLOSING LATE OPENING LATE CLOSING NO OPENING NO CLOSING AUTO-ARM FAILURE ACCESS SCHEDULE CHANGED Holiday Schedule Holiday # Date Partition 1 1 Not Used -- 2 Not Used -- 3 Not Used -- 4 Not Used -- 5 Not Used -- 6 Not Used -- 7 Not Used -- 8 Not Used -- 9 Not Used -- 1 Not Used -- 11 Not Used -- 12 Not Used -- 13 Not Used -- 14 Not Used -- 15 Not Used -- 16 Not Used -- Global Scheduling Data 414XMPT2-11+

414XMPT2-11+ PARTITION SPECIFIC SCHEDULING DATA Open/Close Schedules Partition 1 Open Close Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Temporary Schedules Partition 1 Start Stop Start Stop Status Arm Arm Disarm Disarm Monday -- : AM : AM : AM : AM Tuesday -- : AM : AM : AM : AM Wednesday -- : AM : AM : AM : AM Thursday -- : AM : AM : AM : AM Friday -- : AM : AM : AM : AM Saturday -- : AM : AM : AM : AM Sunday -- : AM : AM : AM : AM Partition Specific Scheduling Data 414XMPT2-11+

414XMPT2-11+ PARTITION SPECIFIC SCHEDULING DATA Scheduling Options Partition Options Auto-Arm Times Force Arm Open/Close Disarm Only Partition for Reports During Delay Warning Disarm Auto-Arm by Exception Disarm Window 1 -- Disable 15 Disable Partition Specific Scheduling Data 414XMPT2-11+

To program these fields, 1. Press *91 to select a partition. 2. Enter a partition-specific field number (ex. *9). 3. Repeat steps 1 & 2 for each partition in the system. 4. To return to the global program fields, press *99. PARTITION-SPECIFIC FIELDS 1st Page Fields *9 ENTRY DELAY #1 2 [2] (-15 times 15 seconds) Maximum 3 for UL Listed installations. *1 EXIT DELAY #1 3 [3] (-15 times 15 seconds) Maximum 4 for UL Listed installations. *11 ENTRY DELAY #2 6 [6] (-15 times 15 seconds) Maximum 3 for UL Listed installations. *12 EXIT DELAY #2 8 [8] (-15 times 15 seconds) Maximum 4 for UL Listed installations. *13 ALARM SOUNDER DURATION 4 1-15 times 2 minutes [4]. Minimum 4 minutes for UL. *16 CONFIRMATION OF ARMING DING 1=enable; [=disable] *22 KEYPAD PANIC ENABLES [1] 1 1=enable; =disable 95 96 99 *23 MULTIPLE ALARMS 1 [1=Yes]; =No *29 QUICK ARM 1 [1=Yes]; =No *32 PRIM. SBSCRBR ACCT# 4 4 3 3 Enter -9; B-F (11-15) [15 15 15 15] *38 PREVENT ZONE XX BYPASS 1-86; [ if all zones (except Fire Zones) can be bypassed] *39 ENABLE OPEN/CLOSE REPORT 1 FOR INSTALLER CODE 1=Enable; [=Disable] *84 SWINGER SUPPRESSION 3 [15] -15 alarms; Must be "" (disabled) for UL. *85 ENABLE DIALER REPORTS FOR PANICS & DURESS 95 96 99 Duress 1=Enable; [=Disable] *87 ENTRY WARNING 1 [1=Continuous]; =3 Beeps *88 BURG. ALARM COMM. DELAY 1=16 seconds; [=no delay] *9 SECONDARY SUBSCRIBER ACCOUNT # Enter -9; B-F(11-15) 1 5 1 5 1 5 1 5 [15 15 15 15] CURRENT LCD DISPLAY FOR THIS PARTITION ****DISARMED**** READY TO ARM PARTITION # 1 PROGRAM FIELDS 2nd Page Fields 1*43 PERMANENT KEYPAD BACKLIGHT 1=Enable; [=Disable] When disabled, display lights when any key is pressed, and turns off after period of keypad inactivity. 1*45 EXIT DELAY SOUNDING 1=Enable; [=Disable] Produces quick beeping during exit delay if enabled. 1*47 CHIME ON EXTERNAL SIREN 1=Enable; [=Disable] 1*52 SEND CANCEL IF ALARM + OFF 1=No restriction; [=Within Bell Timeout period only] 1*76 ACCESS CONTROL RELAY [] FOR PARTITIONS Relay will be pulsed for 2 seconds whenever code + [] is pressed. Enter -16; = none 3rd Page Fields 2*5 AUTO-ARM DELAY 1 5 Enter the time between the end of the arming window and the start of auto-arming warning period, in values of 1-14 times 4 minutes =instant; [15=no auto arm at all]. When this delay expires, the Auto-Arm Warning Period begins. 2*6 AUTO-ARM WARNING PERIOD 1 5 This is the time during which the user is warned to exit the premises prior to the auto-arming of the system (beeps every 15 seconds; "ALERT" displayed). Enter 1-15 minutes. [=instant at end of arming delay]. 2*7 AUTO-DISARM DELAY 1 5 This is the time between the end of the disarming window and the start of auto-disarming. Enter 1-14 times 4 minutes; =instant at end of window; [15=no auto-disarm]. 2*8 ENABLE FORCE ARM FOR AUTO-ARM [=Disable]; 1=Enable 2*9 ENABLE OPEN/CLOSE REPORTS BY EXCEPTION [=Disable]; 1=Enable; If enabled, only openings and closings occurring outside the scheduled opening/closing windows will trigger dialer reports. Opening reports will also be suppressed during the closing window, in order to prevent false reports when the user arms the system and then reenters the premises to retrieve a forgotten item. 2*1 ALLOW DISARMING ONLY DURING ARMING/DISARMING WINDOWS See system-wide field 2*11 if enabling field 2*1. This feature adds high security to the installation. [=Disable]; 1=Enable 2*18 ENABLE GOTO FOR THIS PARTITION [=Disable]; 1=Enable 2*2 ENABLE J7 TRIGGERS BY PARTITION 1 =Disable for displayed partition; [1=Enable for displayed partition] Partition 1 414XMPT2-11+