Military COTS 28V IN Filter MVA-FIAM9

Similar documents
Military COTS 28V IN Filter M-FIAM9 Model Number M-FIAM9M21* Actual Size: 2.28 x 2.2 x 0.5in 57,9 x 55,9 x 12,7mm

Military COTS 28V IN Filter M-FIAM5B Model Number M-FIAM5B21*

Military COTS 28 Vin Filter M-FIAM5B Model Number M-FIAM5BM21*

FIAM 72 V Input. Filter Input Attenuator Module FIAM 072 C 1 1. Features. Absolute Maximum Rating. Product Highlights. Thermal Resistance

Compatible Products. Input Characteristics

Compatible Products. Mini, Micro, Maxi 48 V Input DC-DC converters. Absolute Maximum Rating. Pin soldering temperature. Thermal Resistance

Military COTS 28 Vin Filter M-FIAM7 Model Number M-FIAM7M21*

MicroPAC AC-DC Power Supply

VIPAC Array Family. of DC-DC Converters Up to 750 Watts. Description & Installation Guide. Product Description

Data Sheet VI-IAM, VE-IAM. Input Attenuator Modules. VI-IAM Specifications (Typical at TBP = 25 C, nominal line, 75% load, unless otherwise specified)

Description & Installation Guide

Maxi Family 110V Input

Maxi Family 72V Input

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

20W DC-DC Converter P20J-Series

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

DC Output Voltage range: 1V to 50V Current: up to 30A Power: up to 400W. Efficiency Typical 85-87% - (nominal line, full load, room temperature)

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

ORDERING INFORMATION SEE PAGE 6

Universal Power Supplies

Each module: 2.28 x 2.2 x 0.5in 57,9 x 55,9 x 12,7mm. Absolute Maximum Ratings. Pin soldering temperature

VITA 62 VPX-6U 18V - 40V. Input EMI. Operation: -40 C to 85 C (at Card Edge) VPX Features. Outputs: VS1:

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

End of Life - Not Recommended for New Designs. Data Sheet. Off-Line Front Ends. Single or Three Phase Strappable

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Continuous Input Voltage Filtering Outputs Maximum Output Power Typical Efficiency Operation: -40 C to 85 C (at Card Edge)

TEP 100WIR Series, 100 Watt

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

C B. Models. Operating up to 5000m altitude 5 year product warranty

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

Packaging (5) Protection (3) Isolation Voltage (4)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

VPX 6U 18V - 40V Continuous Input Voltage VITA 62 Compliant Power Supply Input EMI Filtering 5 Outputs 1000W Maximum Output Power Operation: -40 C to

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

CINT W Triple Output Industrial Series

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

PESD5V0U2BT. 1. Product profile. Ultra low capacitance bidirectional double ESD protection diode. 1.1 General description. 1.

Technical Specification VPX 3U Block Diagram for VPX-3U-DC28P VOUT Vin+ Vin rtn EMI Filter (Passive) Isolated Non-isolated +5VOUT Non-isolated

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

PESD3V3L1UA; PESD3V3L1UB; PESD3V3L1UL

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

TEP 75WI Series, 75 Watt

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

PESD5V0U1BA; PESD5V0U1BB; PESD5V0U1BL

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

CVN300-96P01A SERIES. Five Output. Special Features

DPX15W Rated Input voltage range 24V nominal input VDC 48V nominal input 18-75VDC. Input Fuse 24V input, 6A Fuse 48V input, 4A fuse

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

SY89645L. General Description. Features. Block Diagram. Applications. Markets. Precision Low Skew, 1-to-4 LVCMOS/LVTTL-to-LVDS Fanout Buffer

Military Product Catalog

12-15VDC (12V±5%) 24-28VDC (24V±5%)

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

CM1621. LCD and Camera EMI Filter Array with ESD Protection

CM DE. 4-Channel LCD and Camera EMI Filter Array with ESD Protection

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Package (4) Control Logic (3)

ML100SRI. Series. Ultra-Miniature, 1W High Isolation, SMT DC/DC Con vert ers. Key Features:

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

CM1409. LCD and Camera EMI Filter Array with ESD Protection

Vin+ Vin rtn Block Diagram for -6U-DC28T-001 EMI Filter (Transient Protection) EMI Filter (Transient Protection) ENABLE INHIBIT +12V_SHARE (+) Isolate

IEC/EN/UL60950 & CE certified, EN55032 Class B

ATR012-HEX-3U. 1/2 ATR Chassis, Sealed w/heat Exchange KEY FEATURES

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

ME to 30W Single Output External Power Medical Series. Features

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

SPECIFICATIONS. Input Output Agency Approvals

VRM 8.1 DC-DC Converter Design Guidelines

20W DC-DC Converter P20H-Series

SM320A~SM3200A SCHOTTKY DIODE REVERSE VOLTAGE 20 TO 200V FORWARD CURRENT 3.0A

Enclosed Power Supplies

VI-IAM /MI-IAM Input Attenuator Module

Output Current Input Current Max. capacitive Load

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Universal input VAC <150mW No load power consumption

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

CPCI - 6U - DC - 350W

Series AM20EW-NZ 20 Watt DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

PESD5V0C1USF. in portable electronics, communication, consumer and computing devices.

Series AM1S-Z 1 Watt DC-DC Converter

Transcription:

Military COTS 28V IN Filter MVA-FIAM9 Input Attenuator Module Features & Benefits EMI filtering-mil-std-461e [1] Transient protection-mil-std-704a/e/f, MIL-STD-1275A/B/D Environments-MIL-STD-810, MIL-STD-202 Environmental stress screening Output power up to 500W Output current up to 18A Inrush current limiting Cold plate mounting Product Highlights The MVA-FIAM9 is a DC front-end module that provides EMI filtering and transient protection. The MVA-FIAM9 enables designers using Vicor s Maxi, Mini, Micro Series 24V & Maxi Series 28V DC-DC converters or VIPAC Arrays to meet conducted emission / conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704A/E/F and MIL-STD-1275A/B/D. The MVA-FIAM9 accepts an input voltage of 10 36V DC and delivers output power up to 500W. MVA-FIAM9 is mounted on a 4.69 x 3.62 coldplate with a height of 0.81 and convenient input and output connectors. Absolute Maximum Rating Parameter Rating Unit Notes +IN to IN MTBF per MIL-HDBK-217F (MVA-FIAM9M) Temperature Environment MTBF Unit 25 C Ground Benign: G.B. 3,379 1,000Hrs 50 C Naval Sheltered: N.S. 608 1,000Hrs 65 C Airborne Inhabited Cargo: A.I.C. 476 1,000Hrs Part Numbering MVA-FIAM9 M - C Product 36 V DC Continuous 100 V DC 50ms, See Fig.1 250 V DC 70µs Product Grade Temperatures ( C) Grade Operating Storage H = 40 to +100 55 to +125 M = 55 to +100 65 to +125 Blank = Standard C = ON/OFF Control Enabled [1] EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified. Page 1 of 6 06/2017 800 927.9474

Specifications (Typical at T BP = 25 C, nominal line and 75% load, unless otherwise specified) INPUT SPECIFICATIONS Input voltage 10 28 36 V DC Continuous Inrush limiting 0.007 A/µF Transient immunity 100 V DC 50ms per MIL-STD-1275A/B/D, continuous operation 250 V DC 70µs per MIL-STD-1275A/B/D, continuous operation 70 V DC 20ms per MIL-STD-704A, continuous operation 50 V DC 12.5ms per MIL-STD-704E/F, continuous operation OUTPUT SPECIFICATIONS Output power 500 W Output current 18 A Efficiency 96 97 % Internal voltage drop 0.85 1.5 V 500W, 25 C baseplate External capacitance See Figure 5 on page 4 330 1000 µf 50V CONTROL PIN SPECIFICATIONS ON/OFF control Enable (ON) 0.0 1.0 V DC Referenced to V OUT Disable (OFF) 3.5 5.0 V DC 100kΩ internal pull up resistor SAFETY SPECIFICATIONS Dielectric withstand 1,500 V RMS Input/Output to Base 2,121 V DC Input/Output to Base EMI Standard Test Procedure Notes MIL-STD-461E Conducted emissions: Conducted susceptibility: CE101, CE102 CS101, CS114, CS115, CS116 When using with V28 series converters a 27µH inductor is needed between the filter and converter for compliance below 30% of rated power. EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified. GENERAL SPECIFICATIONS Weight 0.7 (318) Lbs (grams) Warranty 2 Years Page 2 of 6 06/2017 800 927.9474

Specifications (Cont.) MODULE ENVIRONMENTAL QUALIFICATION Altitude MIL-STD-810F, Method 500.4, Procedure I & II, 40,000ft. and 70,000ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6Grms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7Grms for 1 hour per axis. Shock MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts / axis, 1,3,5ft. MIL-STD-202F, Method 213B, 60g, 9ms half sine. MIL-STD-202F, Method 213B, 75g, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7g, 6 directions. Humidity MIL-STD-810F, Method 507.4. Solder Test MIL-STD-202G, Method 208H, 8 hour aging. MODULE ENVIRONMENTAL STRESS SCREENING Parameter H-Grade M-Grade Operating temperature -40 C to +100 C -55 C to +100 C Storage temperature -55 C to +125 C -65 C to +125 C Temperature cycling* 12 cycles 12 cycles -65 C to +100 C -65 C to +100 C Ambient test @ 25 C Yes Yes Power cycling burn-in 12 hours, 29 cycles 24 hours, 58 cycles Functional and parametric ATE tests -40 C and +100 C -55 C and +100 C Hi-Pot test Yes Yes Visual inspection Yes Yes Test data vicorpower.com vicorpower.com *Temperature cycled with power off, 17 C per minute rate of change. Storage Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20, Protection of Electrical and Electronic Parts, Assemblies and Equipment and should be maintained in a temperature controlled factory/ warehouse environment not exposed to outside elements controlled between the temperature ranges of 15 C and 38 C. Humidity shall not be condensing, no minimum humidity when stored in an ESD compliant package. Page 3 of 6 06/2017 800 927.9474

Figure 1 Transient Immunity: MVA-FIAM9 output response to an input transient Figure 2 Conducted Noise; MVA-FIAM9 and model V28A12M200B DC-DC converter operating at 28V DC, 200W Time (ms) 2000 1800 1600 1400 1200 1000 800 600 400 200 0 40 50 60 70 80 90 100 Vin (V) Figure 3 Shut down time of MVA-FIAM9 vs.overvoltage IL (db) 0-10 -20-30 -40-50 -60-70 -80-90 0.01 0.1 1 10 30 Frequency (MHz) CM Insertion Loss DM Insertion Loss Figure 4 MVA-FIAM9 insertion loss Note:The MVA-FIAM9 is shown in the on state. To disable, open the connection between ON/OFF and OUT. 4,700pF 0.01µF +IN +IN +OUT F1 Input Transorb P/N 19180-510 EMI GND MVA- FIAM9 +OUT ON/OFF +OUT C1 0.2µF PC PR Maxi, Mini, Micro 24 Vdc or 28 Vdc Input DC-DC Converter +S SC S IN IN OUT Component Suggestions Recommended Fuse: (F1) 20A (max), Bussmann ABC style Capacitance: (C1) 330µF (min), 1000µF (max) 4,700pF 0.01µF Figure 5 Transient, Surge Protection and Recommended Reverse Polarity Protection. Page 4 of 6 06/2017 800 927.9474

1 11 10 20 1 10 9 18 Input Connector Pin # Function 1 4 VIN 5 7 +VIN 8 NC 9 PE protective earth 10 PE protective earth 11 13 VIN 14 17 +VIN 18 NC 19 PE protective earth 20 PE protective earth Output Connector Pin # Function Pin # Function 1 +VOUT 10 +VOUT 2 +VOUT 11 +VOUT 3 +VOUT 12 +VOUT 4 N/C 13 NC 5 N/C 14 NC 6 N/C 15 On / Off 7 VOUT 16 VOUT 8 VOUT 17 VOUT 9 VOUT 18 VOUT Input Mating Vicor P/N Connector Housing 24795 Pin 24796 Kit 24828 Output Mating Vicor P/N Connector Housing 25050 Pin 24796 Kit 25067 Note: The MVA-FIAM9H and MVA-FIAM9M are delivered with the On / Off control already configured as On using a 0Ω resistor on the underside of the output connector board. The MVA-FIAM9H-C and MVA-FIAM9M-C are delivered without the 0Ω resistor installed, allowing for user control of the On / Off functionality. Figure 6 MVA-FIAM9 Outline and Pinouts Page 5 of 6 06/2017 800 927.9474

Vicor s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit http://www.vicorpower.com/mil-cots_dc-dc/mil-cots_m-fiam_filter_input_attenuator_module for the latest product information. Vicor s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor s Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com Page 6 of 6 06/2017 800 927.9474