IntesisBox BACnet/IP Server DALI

Similar documents
IntesisBox BACnet IP Server - M-Bus

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server Panasonic

IntesisBox KNX - BACnet/IP Client

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.


See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IntesisBox Modbus Server - Honeywell XLS 80

Modbus Server SIEMENS Algorex (printer port)

IntesisBox KNX - BACnet/IP Client

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IntesisBox KNX SAMSUNG NASA Air Conditioners

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

IntesisBox KNX - Mitsubishi Electric G50

IntesisBox LON - KNX

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

IntesisBox Modbus Server Fidelio IP

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server - LON

IntesisBox KNX - AIRZONE

IntesisBox ASCII Server - KNX

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Modbus Server - Mitsubishi Electric G50

IntesisBox ME-AC-BAC-1

IntesisBox Modbus Server Siemens Synova FC330A

IntesisBox BACnet/IP Server Modbus TCP Master

IntesisBox Modbus Server KNX

IntesisBox BACnet/IP Server Modbus RTU Master

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IntesisBox BACnet/IP Server M-Bus meters

IntesisBox Modbus Server BACnet/IP Client

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

IntesisBox Modbus Server M-Bus

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

IntesisBox ASCII Server KNX

IntesisBox KNX. BACnet/IP Client. User's Manual v10 r10 eng

IntesisBox KNX. Mitsubishi Electric G-50A/GB-50A/GB-50ADA/AG-150A. User's Manual Issue date: 03/08/2012 r21 eng

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Manual and application description 4 channel 0-10V dimmer V2.0

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

IntesisBox SMS - Mitsubishi Electric air conditioners

Installation and User Guide

IntesisBox. Making Building Automation go further. BACnet Products

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Operating and mounting instructions

Remote I/O Product Specification

IntesisBox KNX. Modbus RTU master. User's Manual v10 r11 eng

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Remote I/O Product Specification

Webdom Datalogger 1.5

BAS Router BACnet Multi-Network Router

Gateway configuration manual DALI KNX EK-BP1-TP

User Manual Anybus Modbus TCP/RTU Gateway

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

BACnet/IP to BACnet MS/TP Router

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Product and Application Description

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

QUICK-START EMU M-BUS CENTER ENGLISH

BACnet/IP Web Interface

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

PG AC Modbus TCP to LonWorks Protocol Converter

Manual and application description KNX/EIB LED driver V2.0

Artistic Licence. Dali-Scope. User Guide. Dali-Scope User Guide. Version 1-8

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

NetBiter Serial Server User Manual

ABB i-bus KNX AC/S Application Controller

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

User Manual Anybus Serial Server

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

IntesisBox KNX LG Air Conditioning

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

BMEP processor module M580 - Level 1 - Distributed

Web interface BACnet/IP

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TM258LD42DT4L compact base M I/O - 24 V DC

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Short Instructions CG-S / IP-Router

TM258LF42DT compact base M I/O - 24 V DC - CANopen

ECLYPSE Communication Modules

USER'S MANUAL. IntesisBox KNX K01-KNX-1B/16/64 v1.0. r1 eng Issue Date: 2014/06

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Transcription:

IntesisBox BACnet/IP Server - DALI Gateway for integration of DALI ballasts into BACnet/IP networks BACnet IP client BACnet/IP Ethernet DALI bus BACnet IP client LAN TCP/IP IntesisBox DALI ballasts LinkBoxBacnet Configuration Software EIA232 Only needed for configuration (configuration can also be done using Ethernet) IntesisBox is a DALI master device, monitoring and controlling DALI ballasts connected to a DALI bus (up to 64 ballasts can be integrated within a single channel). IntesisBox also supplies the necessary power for the DALI Bus. BACnet client devices connected to the BACnet/IP network can read IntesisBox's internal datapoints by continuous polling or by means of BACnet subscription requests (COV). DALI ballasts can be monitored and controlled from BACnet using standard BACnet objects. IntesisBox BACnet/IP Server series are configured using LinkBoxBacnet, a software tool for Windows TM which is supplied along with the purchase of IntesisBox with no additional cost. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 1 / 7

BACnet interface of IntesisBox BACnet Interface Device type BACnet physical layer / media BACnet configurable parameters Interactivity with the BACnet system Server BACnet/IP (accessible through Ethernet) IP address. Subnet mask. Default gateway address. BACnet port. Device name. Device instance number. Internal point s Read / Write allowed. Subscription requests (COV) allowed. For more details see BACnet interface specifications below. BACnet interface specifications BACnet Conformance Class Supported: Class 3 Data Link Layer Option: BACnet IP, (Annex J) Segmented Requests/Responses Not Supported BACnet Standard Application Services Supported and more details are explained in BACnet IP Server KNX PICS (protocol implementation conformance statement) http://www.intesis.com/pdf/intesisbox_bacnet_ip_server_dali_pics.pdf TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 2 / 7

Existing BACnet objects/properties for each ballast Object name Object type Property Description Dali Sts Analog Input Present Value Byte value representing the status of the ballast Dali PwrLvl Analog Input Present Value Actual power level on the ballast, periodically read by IntesisBox (0 100%) Dali PwrSet Analog Output Present Value Object/property allowing to set the power level control of the ballast (0 100%) Dali Cmd Analog Output Present Value Object/property allowing to send DALI commands to the applying ballast (enumeration-based): Off, 100% Step Up Step Down Go To Scene X Store Current Level as Scene X Remove Scene X Set Fade Rate Set Fade Time Configure Min Level Configure Max Level Configure Power-on Level Configure System failure Level Existing BACnet objects/properties for each group (and broadcast/all ballasts too) Object name Object type Property Description Dali PwrSet Analog Output Present Value Object/property allowing to set the power level control of the group (0 100%) Dali Cmd Analog Output Present Value Object/property allowing to send DALI command to the applying group (enumeration-based): Off, 100% Step Up Step Down Go To Scene X Store Current Level as Scene X Remove Scene X Set Fade Rate Set Fade Time Configure Min Level Configure Max Level Configure Power-on Level Configure System failure Level TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 3 / 7

DALI interface of IntesisBox DALI Interface DALI Bus Supplies power to the DALI bus (+15V +/-2%) Max current drain is 250mA. Opto-isolated from the rest of ports of IntesisBox. Number of ballasts 1 channel / 64 ballasts Parameters that can All of those defined in the DALI standard be configured in each Short Address ballasts using Min Level IntesisBox Max Level Power-on Level System failure Level Fade rate Fade time Group 0..15 membership Scene 0..15 preset value TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 4 / 7

Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 159mm 105mm x 58mm. Color Light Grey / RAL 7035. Supply Voltage 230Vac +/-10% 6W (3-pole plug-in terminal block line, neutral and earth) Mounting Wall. DIN rail EN60715 TH35. DALI bus power source DALI port 15Vdc +/-2% 250mA. (DALI bus is powered from IntesisBox) 1 x DALI electrically isolated (2-pole plug-in terminal block). Ethernet port 1 x Ethernet 10BT RJ45. (BACnet/IP, device config) LED indicators 1 x Power indicator. 2 x DALI activity (Tx, Rx). 2 x Ethernet link & activity (LNK, ACT). 1 x DALI bus power 1 x DALI test 1 Push buttons 1 x DALI test 1 Console port EIA232. DB9 female connector (DCE). Configuration Via Ethernet or serial console port. 2 Firmware Allows upgrades via console port. Operational 0 C to +60 C temperature Operational 25-90% at 50ºC, non condensing humidity Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 2 DALI test push-button and LED are meant to perform a quick test of your DALI line and connected ballasts. Standard cable DB9 male-db9 female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device using the serial port (Ethernet is also possible). The configuration software, compatible with Windows operating systems, is also supplied. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 5 / 7

Connections Ethernet / BACnet/IP (and IntesisBox configuration) DALI Bus ETH (BACnet/IP) IntesisBox www.intesis.com DALI - + Serial Port (Not used) PC Console POWER 230VAC 6W N L Power 230Vac LinkBoxBacnet Only needed for configuration, configuration can also be done using Ethernet Console cable 1.8 m long. DB9 Female - DB9 Male standard. Supplied. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 6 / 7

Dimensions External dimensions Ethernet port DALI port 58 mm Serial console port AC mains power 159 mm 105 mm Free space recommended in the install location of the device, with spacing enough for external connections. 100 mm 167 mm 130 mm TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 7 / 7