TEPI11 P/I signal converter

Similar documents
LME620-AI/-AN (Contrac) Electrical Linear Actuator

FICHA TÉCNICA DE PRODUTO

Digital Indicator DS 48/24 E

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

Series 3730 Electropneumatic Positioner Type

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

LineMaster 100 Continuous-line Recorder

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Adapter Plates for continuous Part-Turn Actuators (Contrac)

ABB i-bus KNX AC/S Application Controller

DC561, digital input/output module,

DI561 Digital Input Module

Control Panel CP600-eCo CP604, CP604-B

DX561 Digital Input/Output Module

PI-EX-ME-2NAM/COC-24VDC

AI561 Analog Input Module

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

DC562, digital input/output module,

Indicomp 4 Bargraph Indicator

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

Series 3730 Type Electropneumatic Positioner

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Control Panel CP600 CP651, CP651-WEB

C160 Wall-/Pipe Mounted Universal Process Indicator

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

DI572 Digital Input Module

Messaging module CP-C MM

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Crane-Boy / Crane-BoyP Load limitation electronics

Control Panel CP600 CP635, CP635-B, CP635-WEB

FICHA TÉCNICA DE PRODUTO

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

Redundancy unit CP-A RU

Operating Instructions

PHOENIX CONTACT - 05/2007

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

PROFIBUS-PA Positioner Type 3785

Pluggable interface relays CR-P Pcb relays

INDI BOY DSP Load limitation electronics

Power supply CP-D 12/2.1 Primary switch mode power supply

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

AO561 Analog Output Module

TU531, TU532 Terminal Unit

Power supply CP-E 48/1.25 Primary switch mode power supply

Switching relay CT-IRE with 1 c/o (SPDT) contact

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Bus Connection Unit 560BCU04

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

AO523 Analog Input Module

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Coded Non-Contact Safety Sensor Eden OSSD

Inductive sensor with analog output BI15-M30-LI-EXI

STEP-PS/1AC/24DC/1.75

TF501, TF521 Terminal Bases

Accessories for pluggable interface relays CR-P Sockets

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Power supply CP-E 24/0.75 Primary switch mode power supply

Redundancy Module QUINT-DIODE/40

Operating instructions. Standstill monitor A / / 2011

Power Supply HARTING pcon

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Thermal Mass Flowmeter Sensyflow FMT200-D

Control Panel CP600 CP635-FB, CP635-FW

Pluggable interface relays CR-M Miniature relays

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Power Supply HARTING pcon

T EN TROVIS Electropneumatic Positioner

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Power supply CP-E 24/10.0 Primary switch mode power supply

DeltaV Bulk Power Supplies

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Temperature Transmitter head mounted TF02/TF02-Ex, field mounted TF202/TF202-Ex

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB MEASUREMENT & ANALYTICS DATA SHEET. Testomat AW101 Water hardness monitor

SITRANS P measuring instruments for pressure

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Transcription:

Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation Sturdy construction and solid functionality Influence of shock and vibration < 1 % at 10 g Variety of signal ranges Input 0.2... 1 bar (3... 15 psi) Output 4... 20 ma Characteristic curve (linear) Max. deviation 0.5 % Supply voltage 12... 30 V DC Intrinsic Safety, EEx ib IIC T6

Wechsel ein-auf zweispaltig P/I signal converter TEPI11 Air pressure 0.2... 1 bar (3... 15 psi) in 4... 20 ma current Wechsel ein-auf zweispaltig 1 Concept The signal converter transforms the input signal 0.2... 1 bar (3... 15 psi) into the output signal 4 20 ma. The pressure at the input is recorded by the DMS sensor and converted by the downstream electronics unit to the output signal in proportion to the measured value. The electronic unit is designed for two-wire technology, i.e. the power supply and output signal flow across the same wire pair. Secondary equipment such as the display, recorder or controller must be looped into the electrical circuit. A direct current is required for the power supply, and can be between 12... 30 V. The converter can be provided for intrinsically safe operation. For supply power, a power supply unit approved for intrinsically safe operation or an approved feed separator is required. 2 Technical data Wechsel ein-auf zweispaltig 2.1 Input (pneumatic) Sensing element DMS sensor with silicon membrane Input 0,2... 1 bar (3... 15 psi) Overload limit 2 bar (30 psi) 2.2 Output (electrical) Signal range 4 20 ma, two-wire technology Load voltage U B = U S - 12 V (U S = Supply voltage V) Capacitance/Inductance 15 nf and 90 µh 2.3 Power supply (electrical) Supply voltage 12... 30 V DC, ripple U SS 0.2 V Power consumption 20 ma (at 100 % input signal) 2.4 Transmission data and influences Characteristic linear, direct or reverse action Deviation 0.5 % Hysteresis 0.15 % Response sensitivity 0.1 % Temperature influence (zero point and span) 1.4 % / 10 K Power supply 0.015 % / V change in supply voltage Mechanical vibration 0.5 % to 1 g and 80 hz Mounting orientation 0.1 % at 90 change of position. 10/18-0.15-EN EMC meets EMC directive 89/336/EEC as of May 1989 (increased EMI shielding per EN 50082-2 PR as of 11/93) CE mark complies with EC directive for CE certificate of conformity 2.5 Explosion protection ae Intrinsic Safety EEx ib IIC T6 2.6 Environmental capabilities Climate class ZUF acc. to DIN 40040 Temperature Relative humidity 2.7 Design for rail mounting Material/protection Housing IP 20 aluminum with plastic cap -20 60 C (-4... 140 F) -20 80 C (-4... 176 F) for operation, storage or transport 75 % mean, 95 % short-term no condensation Mounting Rail mounting EN 50022-35 x 7,5 EN 50035 - G 32 EN 50045-15 x 5 Electrical connection 2-pole screw terminal for 2.5 mm 2 (14 AWG) Pneumatic connection Two 1/8 NPT threads for air supply and output Weight 0.25 kg (0.55 lb) Dimensions Refer to dimensional drawings 2

Data Sheet P/I signal converter TEPI11 Air pressure 0.2... 1 bar (3... 15 psi) P/I signal converter TEPI11 Air pressure 0.2... 1 bar (3... 15 psi) in 4... 20 ma current 2.8 Dimensioned drawings 2.8.1 Design for control room housing unit for rail mounting 10/18-0.15-EN Fig. 1: Dimensions in mm (inch) 1 Electrical connections 2 Filter 3 Output 4 Supply air 5 Mounting bracket for DIN rails 3

P/I signal converter TEPI11 Air pressure 0.2... 1 bar (3... 15 psi) in 4... 20 ma current Order information 3 Ordering information 10/18-0.15-EN P/I Converter Variant digit No. 1-7 8 9 10 11 12 TEPI11 Catalog No. V18321- Design / Explosion protection Control room housing for rail mounting standard 1 0 0 Intrinsic Safety EEx ib IIC 5 0 0 Characteristic curve rising 1 falling 2 Input signal range 0.2... 1 bar 1 3... 15 psi 2 (other ranges on request) Ex stock versions Catalog No. P/I Converter TEPI11 Design Explosion protection Input signal range Control room case, for rail mounting none 0.2... 1 bar V18321-10011 3... 15 psi V18321-10012 4

Contact us ABB Ltd. Process Automation Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Phone: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. Process Automation 125 E. County Line Road Warminster, PA 18974 USA Phone: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2010 ABB All rights reserved 10/18-0.15-EN Rev. A 12.2010 3KXE321001R1001 ABB Automation Products GmbH Process Automation Schillerstr. 72 32425 Minden Germany Phone: +49 551 905-534 Fax: +49 551 905-555 www.abb.com