Features. SC Switch Control Platforn. SC2000, SCX2000, SCP2000 SCM Series Modules

Similar documents
RF SWITCH NETWORK RFB 6000

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

Compact Redundancy Switch 2:1 RSCC-2

SUBMINIATURE SERIES R 591. SUBMINIATURE SPnT up to 40 GHz. Our Most Important Connection is with You. SMA SMA 2.9 QMA

PLATINUM SERIES R PART NUMBER SELECTION. High performance SPDT up to 40 GHz. Our Most Important Connection is with You. SMA - SMA 2.

Series 8000 RF Signal Switch Solution

S-Band Redundant LNA Systems

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

Compact Redundancy Switch 2:1 RSCC-2

ELECTROMECHANICAL SWITCH MATRICES

Redundancy Switch Controller 1:1 RSCM1

Series Watt DC Power Supplies

Product Overview. 50Ω DC to 18 GHz. Rack-Mounted USB & Ethernet Control

Prisma II Platform. Optoelectronics

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS

Series 8000 RF Signal Switch Solution

EMSwitch RF Switch Plug-In Card

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The

THAYER SCALE. AUDiTORTM CONTINUOUS WEIGHING & FEEDING OF BULK MATERIALS. NTEP CERTIFIED Conveyor Belt Scale Monitor and Software package.

CREATING YOUR OWN RF SWITCHING SYSTEM

SPDT up to 50 GHz Pc Board - SMA - SMA mm - QMA - SMC - SMB - mini SMB - DIN 1.6/5.6 R Actuator Voltage: 2: 12 Vdc 3: 28 Vdc

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Cisco Prisma II Platform

SP3T SP4T SP5T SP6T. (GHz) 4~ ~ Model Number Selection

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Media Converters. Media Converters. Product Selection Guides

Engine & Genset Controls Z, page 1 of 12

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Bus Bar Protection Relay B-PRO 4000

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Agilent 87406B Coaxial Matrix Switch dc to 20 GHz Product Overview

LightRules Network Infrastructure

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

PTP 810 SOLUTIONS LICENSED MICROWAVE WITH NATIVE ETHERNET AND NATIVE TDM SUPPORT IN ONE PLATFORM. PTP 810 SPECIFICATION SHEET from Release 01-00

Installing the IPS 4345 and IPS 4360

BSL Hardware Guide for MP35 and MP30-1 -

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

Precision thermometer Model CTR5000

TCF-142 Quick Installation Guide

High Voltage Power Supplies

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

TC-5972D Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filter on all Data and DC lines. Customizable Data connections

DMT345 and DMT346 Dewpoint Transmitters

RF switch network. RFB 2000, RFC 2010 or 2020

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

V C ALIANT OMMUNICATIONS. 4 x Ethernet over T1 (IP over TDM) Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Highest-performance Industrial PC

Installation Instructions

SEMS-4052-SPDT-SMA DATA SHEET

Technical Data Sheet OPUS A8 STANDARD Full TDS OPUS A8sF,

Modular Test System. ZTM Series

Domain 3000 Back Panel

R Actuator Terminals: 0: Solder pins 5: D-Sub connector

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

KVM Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB 2.0 Link Up To 200 Meters

TC-5915A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

SEMS-4066-DPDT-SMA DATA SHEET

Cisco ONS CL Shelf Assembly Hardware

HXV SERIES HIGH VOLTAGE SWITCHING SYSTEMS

MultiViu Flex 4 Data Sheet

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Specifications MLC Plus 50/100/200 Series

with Backlight Graphic LCD Screen

TC-5972DP Pneumatic Shield Box

General Specifications

DCM Dynamic Contact Measuring

ViaLite RF Splitter / Combiner

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Control Panel CP600-eCo CP604, CP604-B

Converter Box Data Sheet

Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF,

Stocked Electro-Mechanical Switches

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Series CCR-59S/CR-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

DF PROFI II PC/104-Plus

Agilent U2100A Series Digital IO, 32-Terminal Devices

SWITCH SOLUTIONS SWITCH MATRIX CATALOG ELECTROMECHANICAL MATRIX SOLID STATE MATRIX FIBER OPTIC MATRIX FULLY INTEGRATED SYSTEMS

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Wayside Wireless Pole Line Products

Wayside Wireless Pole Line Products

KONSTANTER SPL Series Programmable Electronic Load

horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Multiple Application Platform MAP-200

SEMS-4080-SP12T-SMA DATA SHEET

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

LDC 3700C Series. The Standard for High Performance Laser Diode Control. Laser Diode Controllers. Product Features

CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

RAMSES SERIES R 57. SPnT Terminated & non Terminated up to 40 GHz. Our Most Important Connection is with You.

DVI Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB + Audio Link Up To 800 Meters

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Transcription:

SC2, SCX2, Features The SC switch control platform is designed for a multitude of switching applications in RF systems. Each of the main chassis is equipped with five (5), rear-facing, user-configurable slots. Individual slots or groups of slots can be populated with a variety of SCM series RF switch modules. The Model SC2 can be fiber-optically combined with up to seven (7) model SCX2 expansion units. The model SCX2 is mechanically identical to the model SC2, but does not contain a control panel. Instead, control is provided by the connected model SC2. For backward compatibility with the legacy model SC1, the model was created. This model provides identical switch configuration and operation to the legacy model SC1 and its modifications (M1 M5). All of these switch controller systems can be controlled either manually, using the provided color LCD touch display, or remotely, using any of the four provided remote ports (USB, GPIB, RS-232, and Ethernet). System interlock capability is provided on the Models SC2 and by sensing switch closures on three independent inputs. Three separate user definable configurations are provided for times when interlock switch closures are not sensed. A user defined safe configuration is also provided for use during signal re-routing in order to assure cold switching of any attached amplifiers and loads. In addition to the three interlock configurations and single safe configuration, eight (8) user configurations can be saved and recalled for ease of use in complex systems. A positive 24 VDC signal along with four (4) open drain outputs, and four (4) digital outputs (TTL) are supplied for applications such as external switch/relay control. The export classification for this equipment is EAR99. SC2 RF switch control platform base unit. Can be controlled manually via front panel touch display or via four (4) provided remote ports. The SC2 has five (5) user configurable module slots on the rear panel. SCX2 RF switch control platform sub unit. The SCX2 does not have a control panel or remote control ports and therefore must be connected to a Model SC2 for local or remote control. The SCX2 has five (5) user configurable module slots on the rear panel. AR RF/Microwave Instrumentation 16 School House Rd Souderton, PA 18964 215-723-8181 For an applications engineer call:8.933.8181 RF switch control platform base unit configured to imitate a legacy Model SC1. Can be controlled manually via front panel touch display or via four (4) provided remote ports. The module slots are populated to provide drop-in replacement of the Model SC1 and any of its associated modifications (M1 M5). www.arworld.us

Page 2 SC2, SCX2, Rated Voltage Rated Frequency Rated Power 1 24 V AC 5 6 Hz 1 VA max. Dimensions W x H x D 48.26 x 13.34 x 44.77 cm (19. x 5.25 x 17.625 in) Weight SC2 (without modules) approx. 4.1 kg (9 lbs) SCX2 (without modules) approx. 3.9 kg (8.5 lbs) (with modules) approx. 6.8 kg (15. lbs) Interfaces (front panel) S C 2 S C X 2 S C P 2 Display/Control Panel for manual operation 1-1 48 x 272 pixel, resistive touch, LED backlight Interfaces (rear panel) USB for remote control 1-1 Test and Measurement Class; Full Speed (12 Mbps); Type-B Connector GPIB (IEEE-488) for remote control 1-1 24-pin, Female Connector RS-232 for remote control 1-1 9-pin, Subminiature D, Female Connector Ethernet for remote control 1-1 TCP/IP, 1 Mbps, RJ-45 Connector Fiber-Optic Serial connection of base unit with extension units 1 1 1 Separate Tx & Rx, SMA Connectors, 5 kbps Interlock Connector 1 1 1 15-pin, Subminiature D, Female Connector safety interlocks 3-3 Active low, Internal 1k pull-up to +5 VDC open drain outputs 4 4 4 8 ma current sinking each* digital outputs 4 4 4 TTL voltage supply (use with open drain outputs) 1 1 1 +24 VDC, 1.5 A max. (internally fused) ground return (use with open drain outputs) 2 2 2 *Open drains 3 and 4 have internal 1K Ohm pull-ups to 3.3V. Other Export Classification Module Slots Number of module slots Number of control buses for modules EAR99 5 on rear of unit 5 Dimensions (W x H x D) Single module slot slot 3 3.68 x 8.84 x 3.23 cm (1.45 x 3.48 x 11.9 in) Double-width module slot slots 1, 2, 4, 5 7.42 x 8.84 x 3.23 cm (2.92 x 3.48 x 11.9 in)

Page 3 SC2, SCX2, Module Specifications Model Connectors Frequency Range Description Buses Slots SCM1S1S2 SMA (f) DC 18 GHz RF switch module 1x SPDT coaxial switch SCM1S1K2 K (f) DC 4 GHz 1 single SCM1S1N2 N (f) DC 12 GHz SCM2S1S2 SMA (f) DC 18 GHz RF switch module 2x SPDT coaxial switch SCM2S1K2 K (f) DC 4 GHz 1 single SCM2S1N2 N (f) DC 12 GHz double SCM4S1S2 SMA (f) DC 18 GHz RF switch module 4x SPDT coaxial switch 1 double SCM4S1K2 K (f) DC 4 GHz SCM1S1S4 SMA (f) DC 18 GHz RF switch module 1x SP4T coaxial switch SCM1S1K4 K (f) DC 4 GHz SCM1S1N4 N (f) DC 12 GHz 1 double SCM2S1S4 SMA (f) DC 18 GHz RF switch module 2x SP4T coaxial switch 1 double SCM2S1K4 K (f) DC 4 GHz SCM1S1S6 SMA (f) DC 18 GHz RF switch module 1x SP6T coaxial switch SCM1S1K6 K (f) DC 4 GHz SCM1S1N6 N (f) DC 12 GHz 1 double SCM2S1S6 SMA (f) DC 18 GHz RF switch module 2x SP6T coaxial switch 1 double SCM2S1K6 K (f) DC 4 GHz Parameter SCM1S1S2 SCM1S1K2 SCM1S1N2 1x SPDT coaxial switch 5 Ω Frequency Range DC 18 GHz DC 4 GHz DC 12 GHz Switching time (nominal) < 35 ms < 15 ms < 5 ms Number of switching cycles 1 million 1 million 1 million Current consumption max. 15 ma (+24 VDC) max. 2 ma (+24 VDC) max. 135 ma (+24 VDC) Dimensions (W x H x D) 3.68 x 11.63 x 3.23 cm (1.45 x 4.58 x 11.9 in) Slot position 1, 2, 3, 4, or 5 3.68 x 11.63 x 3.23 cm (1.45 x 4.58 x 11.9 in) 3.68 x 11.63 x 3.23 cm (1.45 x 4.58 x 11.9 in) Weight approx..23 kg (.5 lb) approx..23 kg (.5 lb) approx..41 kg (.9 lb)

Page 4 SC2, SCX2, Parameter SCM2S1S2 SCM2S1K2 SCM2S1N2 2x SPDT coaxial switch 5 Ω Frequency Range DC 18 GHz DC 4 GHz DC 12 GHz Switching time (nominal) < 35 ms < 15 ms < 5 ms Number of switching cycles 1 million 1 million 1 million Current consumption max. 15 ma (+24 VDC) max. 4 ma (+24 max. 27 ma (+24 VDC) VDC) Dimensions (W x H x D) 3.68 x 11.63 x 3.23 cm 3.68 x 11.63 x 3.23 cm 7.42 x 11.63 x 3.23 cm (1.45 x 4.58 x 11.9 in) (1.45 x 4.58 x 11.9 in) (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 3, 4, or 5 1, 2, 4, or 5 Weight approx..27 kg (.6 lb) approx..27 kg (.6 lb) approx..41 kg (.9 lb) Parameter SCM4S1S2 SCM4S1K2 4x SPDT coaxial switch Connector Type SMA (f) K (f) 5 Ω Frequency Range DC 18 GHz DC 4 GHz Switching time (nominal) < 35 ms < 15 ms Number of switching cycles 1 million 1 million Current consumption max. 15 ma (+24 VDC) max. 8 ma (+24 VDC) Dimensions (W x H x D) 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 4, or 5 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Weight approx..41 kg (.9 lb) approx..41 kg (.9 lb) Parameter SCM1S1S4 SCM1S1K4 SCM1S1N4 1x SP4T coaxial switch 5 Ω Frequency Range DC 18 GHz DC 4 GHz DC 12 GHz Switching time (nominal) < 35 ms < 15 ms < 5 ms Number of switching 1 million 1 million 1 million cycles Current consumption max. 155 ma (+24 VDC) max. 13 ma (+24 VDC) max. 235 ma (+24 VDC) Dimensions (W x H x D) 7.42 x 11.63 x 3.23 cm 7.42 x 11.63 x 3.23 cm 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) (2.92 x 4.58 x 11.9 in) (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 4, or 5 1, 2, 3, or 4 Weight approx..36 kg (.8 lb) approx..36 kg (.8 lb) approx..68 kg (1.5 lb)

Page 5 SC2, SCX2, Parameter SCM2S1S4 SCM2S1K4 2x SP4T coaxial switch Connector Type SMA (f) K (f) 5 Ω Frequency Range DC 18 GHz DC 4 GHz Switching time (nominal) < 35 ms < 15 ms Number of switching cycles 1 million 1 million Current consumption max. 31 ma (+24 VDC) max. 26 ma (+24 VDC) Dimensions (W x H x D) 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 4, or 5 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Weight approx..54 kg (1.2 lb) approx..54 kg (1.2 lb) Parameter SCM1S1S6 SCM1S1K6 SCM1S1N6 1x SP6T coaxial switch 5 Ω Frequency Range DC 18 GHz DC 4 GHz DC 12 GHz Switching time (nominal) < 35 ms < 15 ms < 5 ms Number of switching cycles 1 million 1 million 1 million Current consumption max. 155 ma (+24 VDC) max. 13 ma (+24 VDC) max. 235 ma (+24 VDC) Dimensions (W x H x D) 7.42 x 11.63 x 3.23 cm 7.42 x 11.63 x 3.23 cm 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) (2.92 x 4.58 x 11.9 in) (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 4, or 5 1, 2, 3, or 4 Weight approx..36 kg (.8 lb) approx..36 kg (.8 lb) approx..73 kg (1.6 lb) Parameter SCM2S1S6 SCM2S1K6 2x SP6T coaxial switch Connector Type SMA (f) K (f) 5 Ω Frequency Range DC 18 GHz DC 4 GHz Switching time (nominal) < 35 ms < 15 ms Number of switching cycles 1 million 1 million Current consumption max. 31 ma (+24 VDC) max. 26 ma (+24 VDC) Dimensions (W x H x D) 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Slot position 1, 2, 4, or 5 7.42 x 11.63 x 3.23 cm (2.92 x 4.58 x 11.9 in) Weight approx..54 kg (1.2 lb) approx..54 kg (1.2 lb)

Page 6 SC2, SCX2, RF Switch Power Handling Frequency Range Notes K SMA N DC.1 GHz VSWR 1.1:1 4 W 45 W 12 W DC.5 GHz 2 W 275 W 6 W.5 1 GHz 15 W 2 W 45 W 1 GHz 4 GHz 75 W 1 W 25 W 4 GHz 8 GHz 55 W 75 W 175 W 8 GHz 12 GHz 45 W 55 W 15 W 12 GHz 18 GHz 35 W 5 W ----- 18 GHz 4 GHz 25 W ----- ----- RF Switch Power Derating Factor VSWR 1.5:1 94 2.:1 88 2.5:1 83 3.:1 78 3.5:1 73 4.:1 7 Derating Factor Block Diagram Model Configurations SLOT NUMBER 1 2 4 5 3 SWITCHES INSTALLED MODEL NUMBER SW1 SW2 SW3 SW4 SW5 SW6 SW7 SMA SMA N N SMA M1 SMA SMA N N SMA SMA N M2 SMA SMA SMA M3 SMA SMA SMA SMA M4 K K K K M5 SMA SMA SMA SMA N

Model Configurations Page 7 SC2, SCX2, M1 M2 M3 M4 M5 Controller designed for multi-amplifier/multi-load application where reverse power measurement is not necessary. Controller designed for multi-amplifier/multi-load applications with forward and reverse power measurement and emissions feedback. Controller accommodates forward power measurement and higher power/higher frequency amplifier and load combinations where switching and cable losses need to be minimized. Controller accommodates forward and reverse power measurement and higher power/higher frequency amplifier and load combinations where switching and cable losses need to be minimized. Controller accommodates forward and reverse power measurement and higher power/higher frequency (up to 4 GHz) amplifier and load combinations where switching and cable losses need to be minimized. Controller accommodates forward and reverse power measurement, higher power/higher frequency amplifier and load combinations where switching and cable losses need to be minimized, and emissions feedback. To order AR Products, call 215.723.8181. For an applications engineer call:8.933.8181. Direct to Service call: 215.723.275 or email: service@arworld.us For Faxing Orders:866.859.582 (Orders Only Please) info@arworld.us Approved for public release by AR RF/Microwave Instrumentation 5317