USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

Similar documents
CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

PROGRAMMER WITH A USB LINK PD14 USER S MANUAL

MODULE WITH 8 LOGIC INPUTS SM5 TYPE

LARGE SIZE DIGITAL CLOCKS DZ2 AND DZ3 TYPES

ANALYSER OF 3-PHASE POWER NETWORK PARAMETERS ND1 TYPE

DIGITAL CLOCK. DLZ Type. Service manual

GSM/GPRS TRANSMISSION MODULE SM8 TYPE

PROGRAMMER FOR N15, N15Z, N17Z DIGITAL METER SERIES and P15, P16 TRANSDUCERS

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE

SCREEN RECORDER KD-Series TYPE

Microlectra bv. 2-CHANNEL MODULE of LOGIC or COUNTER INPUTS SM3 TYPE USERS MANUAL

Microlectra bv. 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USERS MANUAL

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

KS5 SYNCHRONIZATION METER

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

Hardware Manual RM CANview Gateway

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

100% electricity. Automatic transfer switch controllers ATL series

NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

Commercial Grade USB to RS-422/485 Adapter User's Manual

MCX06C Programmable controller

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Island bus expansion module

TCNM-ACBB1 Installation Manual

LARGE SIZE DISPLAY PANELS

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

ICF-1150 Series Quick Installation Guide

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

AEW Pulse Adapter. Building Technologies

CEM M-ETH INSTRUCTION MANUAL (M060B A)

MULTICHANNEL DATA RECORDERS

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RS485 MODBUS Module 6RO

Communication module to connect M-bus devices to POL6xx.xxx controllers.

DIRIS Digiware D and C Communication and control power interfaces

K-LINE. USB RS485 Asynchronous Converter CONVERTERS AND INTERFACES. Serial Converters

ICF-1150 Series Quick Installation Guide

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

MC 11 EB-2 Power supply cabinet with external bus, AC version

Operating Manual MPI-300 NCS-M Parameter Tool

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

CEM-C6 INSTRUCTION MANUAL (M187B B)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Installation instructions Ethernet switch EC / / 2011

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

R507 I.S. Interface Module User Manual

Expansion Port RS485/RS422

Hand-held thermometer Model CTH6200

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

Room unit with PPS2 interface

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Power supply module, bus connection module

RE92.CHECKMATE. Dual loop controller for industry purpose. measuring inputs. Automatic parameter selection according to the controlled object

Extruder Controls ExtruVision S

Voltage Transducer UMT516 / MT516

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

I/O SIGNAL CONDITIONER

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

SUBJECT TO CHANGE WITHOUT NOTICE

Fiber optic converter audio and CAN TA OPERATION MANUAL

CBA HV Circuit Breaker Analyzer and Microhmmeter

EX-RC1 Remote I/O Adapter

P3-SCM. General Specifications

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

PXR11 PXR12. System controllers DESIGO PX

EX-RC1 Remote I/O Adapter

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

MU110-6U. Analog output module 6 channel. User guide

IO1000. Type designation. Product description I/O module INSTALLATION MANUAL. Catalog no. from software version Document no I/O module 1.

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Room unit with PPS2 interface

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Hardware Manual RM CANview

General information Engineering with Programming package. Display with display

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

RS485 MODBUS Module 8AO

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

M-Bus Central Unit. Use

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

DI572 Digital Input Module

Operating instructions Evaluation system for flow sensors VS / / 2013

Transcription:

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description of converter leads... 7 3.3. Installation of the COM port for Windows... 8 3.4. Installation of COM port controllers on the computer... 8 3.5. Example of Lumel Heat and Lumel 3000 configuration... to co-operate with PD10... 11 4. OPERATION DESCRIPTION... 11 5. TECHNICAL DATA... 12 6. EXECUTION CODES AND ORDERING... 13 7. MAINTENANCE AND GUARANTEE... 14

1. APPLICATION The PD10 converter is a device which transmits data from the USB interface to the RS-485 industrial interface. USB interface, as the first, is destined to communicate with the device having a USB Host port, which is the most frequently a PC computer. The RS-485 interface, as the second, is destined to communicate with devices in the object side. The maximal baud rate is 1 Mb/s. This baud rate depends on the RS-485 cable length. The converter does not interfere in the structure of transmitted data and is compatible with several industrial communication protocols, e.g. Modbus RTU, Modbus ASCII, a.s.l. In order to protect devices at both sides of interfaces, a galvanic separation is applied. A program controller of the virtual serial port COM for the computer PC is added to the set. It allows to exchange data by master programs with industrial objects through the P10 converter. 2. CONVERTER SET The PD10 converter set includes: PD10 converter pc User s manual pc Guarantee card pc USB cable of 1.8 m long 1 pc CD with drivers pc When unpacking the converter, please check the set completeness and whether the type and execution code on the data plate correspond to the order code.

3. CONVERTER INSTALLATION 3.1 Converter installation and operational safety The converter is a portable device supplied from the USB bus. Dimensions of the converter are presented on the fig. 1. Fig.1 Overall dimensions of the PD10 converter In the safety service scope, the PD10 converter meets to requirements of the EN 61010-1 standard. Observations concerning the operational safety All operations concerning transport, installation, and commissioning as well as maintenance, must be carried out by qualified, skilled personnel, and national regulations for the prevention of accidents must be observed. Before switching converter on, one must check the correctness of connection to the network. Do not connect the converter to the network through an autotransformer. Before removing the converter housing, one must switch the supply off and disconnect measuring circuits. The removal of the meter housing during the guarantee contract period may cause its cancellation. The PD10 converter is destined to be installed and used in industrial electromagnetic environment conditions.

One must remember that in the building installation a switch or a circuit-breaker should be installed. This switch should be located near the device, easy accessible by the operator, and suitably marked. 3.2. Description of converter leads Markings of individual leads are shown on the fig. 2 Fig. 2 External leads of the PD10 converter External signals must be connected acc. to tables 1 and 2, in which the assignment of individual PD10 converter leads are described. There are two diodes on the frontal plate: Green (RxD) signals the reception of data via RS-485. Yellow (TxD) signals the transmission of data via RS-485. RS-485 interface leads Table 1 Nr of the RS-485 pin RS-485 signals (5) V+ Line +5 V (for teminator) (4) A Line A (3) B Line B (2) GND Line GND (1) GND Line GND

USB interface leads Table 2 Nr of USB pin (type B) USB signal 1 +5 V d.c. 2 -Data 3 +Data 4 GND 3.3. Installation of the COM port for Windows The PD10 converter makes use of FTDIBUS Driver and FTDIPORT Driver, licensed by the Future Technology Devices International Ltd company. This software creates in the system a device of Universal Serial Bus - The Converter USB-RS485 of PD10 type and connected to it, the virtual COM port, named USB-RS485 Converter Port Com of PD10 type. The controller installation in the Windows system causes the addition of a successive COM serial port to the list of ports serviced by the operating system. 3.4. Installation of COM port controllers on the computer After connecting the connector to the USB port, the operating system informs about the appearance of a new device by means of a message presented on the fig. 4. The creator to find the new hardware of the Universal Serial Bus. One must operate acc. to the creator, choosing the installation from the indicated location and giving the path to controllers being in the added CD. 8

Controllers are compatible with systems: Windows 2000, Windows XP, Windows Vista, Windows Server 2003 (x86 and x64). When installing controllers, information about the lack of controller digital signature can occur. One must ignore this information and further continue the installation. Fig. 3 Systemic message about the detection of the PD10 converter through the System After the creator closure, the system immediately detects the next device USB Serial Port (fig. 4). The creator to find new hardware will be started again. Fig. 4 Systemic message about the find of a new device. After a successful termination of the installation, the system informs about the installation of the new hardware (fig.5) In the Device Manager, two new devices appear: - Converter USB RS485 of P10 type and Port COM named: Converter USB-RS485 of PD10 type, acc. the fig. 6.

Fig. 5 Systemic message ending the installation of PD10 controllers Fig. 6. Correct installation of PD10 in the Win32 system 10

3.5. Example of Lumel Heat and Lumel 3000 configuration to co-operate wit PD10 Lumel Heat and Lumel Energy systems communicate with industrial devices by means of COM serial ports. After the installation of additional virtual COM serial ports, one can appeal to them in systems of Lumel series. Then, one must introduce or modify supervising appeals to added communication ports in new or existing applications or system configurations. 4. OPERATION DESCRIPTION The RS-485 standard enables the data exchange of half duplex type. That means that they can be in the same time transmitted or received. PD10 converters can work with a maximal baud rate up to 1 Mb/s depending on the line length (e.g. 9600 kb/s on lines up to 1000 m long, 1 Mb/s on lines up to 10 m long). At lines over 800 m, between lines A and B of the RS-485 interface, one must use terminators (resistors) on ends of the bus. The terminator value should be adapted to the application. In the environment with unknown interference level it is recommended to observe following principles: Connections of communication interface circuits must be conducted individually by twisted wires in a screen. Apply the general principle that wires (group of wires) leading different signals should be led in the possible farthest distance between them (not less than 50 cm) and the crossing of such group of wires should be made at right angle. The device does not fulfil requirements concerning the electromagnetic compatibility in residential environment 11

5. TECHNICAL DATA Transmission data - baud rate up to 1000 kb/s, depending on the line length - data flow direction control automatic - controllers Windows 2000, XP, Server 2003, Vista, Server 2008 (x86 and x64). Converter power consumption 1,5 W Rated operation conditions: - supply voltage V d.c., from the USB port - ambient temperature 0...55 C - relative humidity < 85% - working position any Storage and transport conditions: - ambient temperature 0...70 C - relative humidity < 85% Ensured protection grades (EN 60529): - from the housing side IP 40 - from the terminal side IP 20 Dimensions 44 24 mm Weight 0,1 kg Electromagnetic compatibility: - immunity EN 61000-6-2 - emission EN 61000-6-4 Maximal working voltage in relation to earth: < 50 V 12

6. EXECUTION AND ORDERING CODES PD10 execution codes Table 3 CONVERTER PD10-1 XX X Kind of execution katalogue...00 custom-made*... XX Acceptance tests without extra requirements... 8 with an extra quality inspection certificate... 7 other requirements*... X * The execution code is established by the manufacturer Example of ordering: PD10-1 0 7 code means: PD10 - USB-RS485 interface converter : 1 - with galvanic insulation 00 - catalogue execution 7 - with an extra quality inspection certificate 13

7. MAINTENANCE AND GUARANTEE The PD10 converter does not require any periodical maintenance. In case of some incorrect operations: 1. After the dispatch date and within the period stated in the guarantee card One should return the instrument to the manufacturer s Quality Inspection Dept. If the instrument has been used in compliance with the instructions, the manufacturer guarantees to repair it free of charge. The disassembling of the housing causes the cancellation of the granted guarantee. 2. After the guarantee period: One should send the instrument to repair it in an authorized service workshop. Our policy is one of continuous improvement and we reserve the right to make changes in design and specifications of any products as engineering advances or necessity requires and revise the above specifications without notice. 14

15

SALES PROGRAM MEASUREMENT DIGITAL and BARGRAPH PANEL METERS CONTROL MEASURING TRANSDUCERS RECORDING ANALOG PANEL METERS (DIN INSTRUMENTS) DIGITAL CLAMP-ON METERS INDUSTRIAL PROCESS and POWER CONTROLLERS CHART and PAPERLESS RECORDERS LARGE SIZE DISPLAY PANELS ELEMENTS OF INTEGRATION SYSTEMS ACCESSORIES for MEASURING INSTRUMENTS (SHUNTS) MEASURING SYSTEMS (ENERGY, HEAT, CONTROL) CUSTOM-MADE PRODUCTS ACCORDING CUSTOMER S REQUIREMENTS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF: ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING and THERMOPLASTICS PARTS SUBCONTRACTING of ELECTRONIC DEVICES (SMT) PRESSURE CASTINGS and OTHER TOOLS QUALITY PROCEDURES: According to ISO 9001 and ISO 14001 international requirements. All our instruments have CE mark. For more information, please write to or phone our Export Department Lubuskie Zak³ady Aparatów Elektrycznych LUMEL S.A. ul. Sulechowska 1, 65-022 Zielona Góra, Poland Tel.: (48-68) 329 51 00 (exchange) Fax: (48-68) 329 51 01 e-mail:lumel@lumel.com.pl http://www.lumel.com.pl Export Department: Tel.: (48-68) 329 53 02 Fax: (48-68) 325 40 91 e-mail: export@lumel.com.pl 16 PD10-07.A