RAID Rack (RR2035RPHMS)

Similar documents
User Guide 5-Port HPM-XU (AD5HPMREU)

User Guide External Port Multiplier Ultra (AD5EHPMEU3)

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

User Guide RAID Rack (RR2035ASDML)

RAID Tower XIII (RT134SDEU3)

User Guide RAID Tower IV (RTIV535HEU3)

User Guide RAID Rack (RR2035ASDES)

User Guide Storage Tower IX (ST95HPMXA)

User Guide Storage Tower V (ST55HPMXU)

T E C H N O L O G I E S. User Guide. RAID Tower IX.

Addonics TECHNOLOGIES

1:5 Combo msata HDD Duplicator (MSHDUS5HS)

T E C H N O L O G I E S. User Guide. 1:5 HDD/SSD Duplicator Deluxe C (HD5SNDXHS, HDUS5SNDX)

Model: DS-2250J. Venus T5 mini 2.5 SATA RAID. User Manual.

T E C H N O L O G I E S. User Guide. 1:9 HS HDD Duplicator Pro (HD9SITDRHS)

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

User s guide for T5_R5 esuf

Taurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

T E C H N O L O G I E S. User Guide (HDUS4SNDXHS-A)

TOWERSTOR TS25CT. QUICK INSTALLATION GUIDE v1.0

NAS System. User s Manual. Revision 1.0

Highly Reliable Systems

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

XL-RAID-SATA-USB Data Backup System. User s Guide

NVIDIA / JMicron RAID Installation Guide

Introduction...1. Package Contents... 1 Product Features... 1 Specifications Product Schematic...2. HDD Installation...3

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

User Guide & Owners Manual

The term "physical drive" refers to a single hard disk module. Figure 1. Physical Drive

Diamond Cipher Drive Cartridge System (DCDC256S-C, DCDC256U-C)

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

FUSION R400 RAID USB 3.0

Taurus Mini Super-S LCM

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Taurus Super-S Combo

User Guide Diamond Drive Cartridge System DDCSSAS / DDCSIS DDCSSAU / DDCSIU

GENERAL INFORMATION...5 COPYRIGHT...5 NOTICES AND CLASSIFICATIONS...5 CONTACT US...5

ACT-ARS6032R Disk Array Series products

RAIDECKER BT-3058 User Manual

NVIDIA RAID Installation Guide

RAIDTech USER S MANUAL. Revised October 3, Features

GENERAL INFORMATION...5 COPYRIGHT...5 NOTICES AND CLASSIFICATIONS...5 CONTACT US...5

Mini-EPICa USB 3.0-to-SATA II RAID SUBSYSTEM

NVIDIA RAID Installation Guide

OWC Mercury Rack Pro Assembly Manual & User Guide

T E C H N O L O G I E S. User Guide. 1:5 Duplicator (HDU5SAS)

FIVE-BAY RAID SYSTEM FOR 3.5 SATA HARD-DISK DRIVES

User Guide Diamond Cipher AES 256-Bit ExDrive (DCED256ES / DCED256EU)

PCIE SATA II PATA RAID CARD

SafeTANK GR5630-SB3. User Manual. v.1.0 (April, 2011)

Rocsecure NE52 NAS System

Dual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan. User s Manual

MERCURY RACK PRO. Assembly Manual & User Guide

T E C H N O L O G I E S. User Guide. 1:1 Duplicator (HDUSAS)

Guide to SiS RAID Utility for Windows XP / 2000

AMD SP Promise SATA RAID Guide

CONTENT. Overview 1 LED indication. RAID Mode Selection 3. Quick Installation Guide 4. About RAID RAID function. System Requirements

Storage Profiles. Storage Profiles. Storage Profiles, page 12

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

InTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual

FiT RAID SUBSYSTEM. User s Manual V1.0

Chassis (FRU) Replacement Guide

Addonics T E C H N O L O G I E S. Portable Dual Drive RAID Enclosure. Model: AE25RDESU. Enclosure Overview. RAID Setting button

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

User Guide CipherUSB

Configuring Storage Profiles

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

XL-NAS-400SA. User s Guide

XL-RAID-213SA User Manual

Addonics T E C H N O L O G I E S. Storage Tower Overview. Storage Tower

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

RAID User Guide. Edition. Trademarks V1.0 P/N: U25-A2-0E

Version 3.0. User Manual Revised July 23, 2010

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English)

3. Specifications I Features System Requirements Creating A New Partition / Formatting The Hard Drive RAID Mode Selection...

Definition of RAID Levels

Your Challenges, Our Solutions. The NAS and/or laptop storage are not enough; how can I upgrade once and expand all?

Features Disk setup is near-instantaneous and is capable of JBOD, RAID 0 and 1 disk modes.

RM12_1394B. User Manual. Ver Date: 02/2006.

First Edition, July 2011

RocketU 1144BM Host Controller

SOHORAID Series. SR2611 Series. Manual. Two Bays RAID 1 Internal Module

FUSION QR. User s Guide. 4-Drive Hardware RAID 5 SATA Storage System with Quad Interface. For Windows

ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL. Version 2.2

A12S2-PS. Quick Start Guide. August, 2012 V.1.4

RocketRAID 600L. User s Guide. SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters. Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc.

RocketRAID esata For Mac HighPoint Technologies, Inc.

RocketU 1144CM Host Controller

RocketRAID 464. User, s Manual. Revision: 1.0 Date: Jun HighPoint Technologies, Inc.

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

Addonics. 4X SATA Multilane PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-ML) User s Guide Revision 1.1 T E C H N O L O G I E S

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

Venus T5c Series. Venus T5c series. SATA RAID User Manual. Model: DS-2350C. Model: DS-2250C. Page 1

Dual-Bay 2.5 to 3.5 SATA Hard Drive Adapter Enclosure with RAID

Managing Storage Adapters

Front of Unit. Rear of Unit. 1. Pre-Installation Steps. 1.2 Identifing Parts

SSD Bay U.2 NVMe RAID Enclosure. User Guide V1.00

RTX. RTX Secure 410-3QR User Manual

Transcription:

RAID Rack (RR2035RPHMS) www.addonics.com Technical Support If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at: Hours: 8:30 am - 6:00 pm PST Phone: 408-453-6212 Email: http://www.addonics.com/support/query/

Overview Array 1 Array 2 Array 3 Connector Power Switch: Activates the unit. NOTE: At least one Power Supply must be connected with its Power Supply Switch turned on. Reset Button: Not operational. Buzzer Reset: Silences audible alarm from Thermal Management Card, indicating a fan failure or temperature warning. Alarm will remain silent until unit is turned off and will sound again if the unit is turned on while alarm condition remains unresolved. Temp LED: Normally dark. Flashes when temperature exceeds setting on Thermal Management Card. Fan LED: Normally glows steadily. Flashes when Thermal Management Card senses a chassis fan has failed. HDD LED: Not operational. RPS LED: Normally glows steadily. Flashes to indicate only one power supply is operational. RPS Alarm Silence: Silences audible alarm from RPS subassembly, indicating only one power supply is operational. Alarm will remain silent until unit is turned off and will sound again if unit is turned on with only one power supply operational. 1 www.addonics.com Technical Support (M-F 8:30 am 6:00 pm)

Port Multiplier Compatibility The Port Multipliers in this unit will only work with a Port Multiplier aware esata host adapter when configured in JBOD Mode (individual drives). Identify your host controller and check with its hardware manufacturer if you are unsure. Addonics offers several Port Multiplier aware host adapters. Hot Swapping This unit supports hot swapping (inserting or removing drives while the drives are running and connected to a computer). The esata controller on the computer must also support hot swapping - be sure to confirm this before attempting to insert or remove drives while the system is running. Also be sure to practice the appropriate safe removal procedure before proceeding. Failure to practice safe removal procedures will result in loss or corruption of data. Drive Installation 1. Remove tray and align drive with mounting holes as indicated. The drive's connector end should protrude from the tray slightly. 2.5 3.5 3.5 2. Secure the drive to the tray using four large flat screws on a 3.5 drive, or three of the smaller screws for a 2.5 drive. 3. Insert tray into Disk Array, drive label side up, lever open. Push gently until the tray stops, don't force it. 4. Secure the tray into position by pressing the lever closed. If desired, rotate the lock. 2.5 3.5 3.5 2.5 Phone: 408-453-6212 Email: www.addonics.com/support/query/ 2

Thermal Management Card and Port Multipliers Host Port Target Ports (5) Dipswitch Set Button Audible Alarm Power Connector 3 www.addonics.com Technical Support (M-F 8:30 am 6:00 pm)

Port Multiplier Modes Using identical drives for all settings other than JBOD or LARGE is strongly recommended. Creating a LARGE array using drives that have different properties will use all space on all members, and performance will match that of the member in use during any particular I/O operation. Creating a RAID using drives that are not all the same size will result in all members using only as much space as the smallest member. Creating a RAID using drives that have different performance will degrade the overall performance of the array. The Port Multiplier supports individual drives (JBOD Mode), several types of RAID and some non-raid drive sets. Each configuration has different properties and requirements, as follows: JBOD Mode (Individual Drives) Number of drives: at least 1 Unit capacity: N/A (100% of each individual drive) Spares: no Fault tolerance: none JBOD mode offers all connected units to the host adapter, no RAID is defined at all. NOTE: JBOD mode requires a SATA controller featuring Port Multiplier support for esata connections. NOTE: Optical drives can only be configured as JBOD using an esata connection. RAID 0 (Stripe set) Number of drives: at least 2 Unit capacity: size of each member times number of members. Spares: no Fault tolerance: none - if any member is lost all data is lost. RAID 0 stripes the file system across the array by placing chunks of data sequentially between drives in a specific order. RAID 1 or 10 (Mirror set, Stripe of mirror sets) Number of drives: 2 (RAID 1) or 4 (RAID 10). Unit capacity: size of one member (RAID 1) or size of two members (RAID 10). Spares: yes if EZ mode is not disabled and 3 (RAID 1) or 5 (RAID 10) drives are present, the array will be initialized with a spare. Fault tolerance: RAID 1 can withstand the loss of one drive without losing data. RAID 10 can withstand the loss of one drive from each mirror set without losing data. RAID 1 works by duplicating the exact same data on two drives. RAID 10 works by using two RAID 1 sets configured as members of a RAID 0. Disks 1 and 2 are mirrored, disks 3 and 4 are mirrored, and the two mirror sets are striped together. RAID 3 (Stripe set with dedicated parity) Number of drives: at least 3 Unit capacity: size of one member times number of members minus one. Spares: yes Fault tolerance: can withstand the loss of one drive without losing data. RAID 3 works by striping data for individual I/O blocks across all members except one, which contains parity data for the stripe set computed internally by the Port Multiplier. In the event of failure, the missing information can be calculated using the parity information. Phone: 408-453-6212 Email: www.addonics.com/support/query/ 4

RAID 5 (Stripe set with striped parity) Number of drives: at least 3 Unit capacity: size of one member times number of members minus one. Spares: yes Fault tolerance: can withstand the loss of one drive without losing data. RAID 5 works by striping entire I/O blocks across all members of the set, with each member taking turns carrying parity data computed by the Port Multiplier. In the event of failure, the missing information can be calculated using the parity information. CLONE (Mirror set) Number of drives: at least 2 Unit capacity: size of one member. Spares: yes Fault tolerance: can withstand the loss of any number of drives without losing data as long as at least one complete member remains online. CLONE mode works the same way as RAID 1, by maintaining a complete copy of the entire set of data on each drive. LARGE (Spanned set) Number of drives: at least 2 Unit capacity: 100% of all drives together regardless of differences in size Spares: no Fault tolerance: cannot withstand the loss of any drives without losing data. However, some data may be recovered as long as the drive(s) carrying the file system data (boot record, directory, etc.) remain online. LARGE mode is neither a RAID nor is it a JBOD. It works by declaring the sum of all available space of the member drives as a single unit, without striping the data. As each member is filled, new data is stored on the next. Notes about Spare Drives If EZ mode is disabled (SW1:2 ON), all individual drives not configured as array members will be offered to the host adapter as separate units. To create an array with one or more spares, set or modify the RAID mode while the spares are disconnected from the Port Multiplier. When EZ mode is enabled (SW1:2 OFF), individual drives connected when an array is present are considered spare. Spare drives must be equal to or larger in size than the smallest member. When any type of array is defined, individual units will be considered spare. RAID 0 and LARGE arrays are not fault-tolerant and spare drives will not be useful; therefore, disabling EZ for these arrays is recommended. When a spare drive is present and a fault-tolerant RAID (1, 10, 3, or 5) is defined, EZ mode will automatically rebuild any available spares into the array to replace a failed member. 5 www.addonics.com Technical Support (M-F 8:30 am 6:00 pm)

Configuring the Port Multiplier Using Dipswitches Resetting the RAID NOTE: This procedure destroys all RAID data. It should not harm individual drives or their contents; however, creating backups of all data is strongly recommended before proceeding. Be sure the port multiplier is connected to an active host before proceeding. The port multiplier will not complete the process if it has no host connection. 1. Power down the unit and set the dip switch to the desired RAID Mode. 2. While holding the SET button, turn the unit on. A long beep will sound from the Port Multiplier. The SET button may be released once the long beep starts. Shortly after releasing the SET button, the port multiplier should chirp to indicate the process is complete. If instead of a chirp the Port Multiplier sounds a series of short beeps, an error has occurred during the process. Setting or Modifying the RAID Mode NOTE: Setting or modifying the RAID mode destroys all data. Be sure the port multiplier is connected to an active host before proceeding. The port multiplier will not complete the process if it has no host connection. 1. Follow the procedure for resetting the RAID Mode. 2. Power down the unit and set the dip switch to the desired RAID Mode. 3. While holding the SET button with a ballpoint pen, turn the unit on. A long beep will sound from the Port Multiplier. The SET button may be released once the long beep starts. Shortly afterward, the port multiplier should chirp to indicate the process is complete. If instead of a chirp the Port Multiplier sounds a series of short beeps, an error has occurred during configuration of the array. BZS Switch (SW1:1): The BZS switch is used to silence the audible alarm buzzer. The OFF position permits the audible alarm, and the ON position silences the audible alarm. The BZS switch has immediate effect. EZ Switch (SW1:2): The EZ (spare) switch inhibits spares when ON. When in the OFF position, all individual drives (not defined as members of an array) are considered spare and are not offered to the operating system. Should a RAID become degraded, when the EZ switch is in the OFF position a spare drive will be used automatically to rebuild the RAID, if present. EZ mode is determined when the unit is powered up. Changing the switch will have no effect until the unit has been re-powered. Warning: turning off the EZ switch to rebuild an array will consider any drives not declared array members to be eligible for rebuild as a spare. Rebuilding will destroy all existing data on that drive and the drive chosen is not predictable. Disconnect any individual drives with valuable data on them before enabling EZ Mode. Phone: 408-453-6212 Email: www.addonics.com/support/query/ 6

RAID Mode Switches M2, M1, M0 (SW1:3 SW1-5) The RAID Mode switches define what type of RAID will be initialized when the unit is powered up while the RAID Mode button is held down, as follows: Dipswitch Position 1 (BZS) 1 2 (EZ) 3 (M2) 4 (M1) 5 (M0) JBOD (Individual Drives) * FACTORY DEFAULT OFF OFF 2 OFF OFF OFF SETTING RAID 0 OFF ON 3 ON ON ON RAID 1 OR 10 OFF OFF ON ON OFF RAID 3 OFF OFF ON OFF OFF RAID 5 OFF OFF OFF ON OFF CLONE OFF OFF OFF ON ON LARGE OFF ON 3 ON OFF ON NOTES: 1 Audible Alarm is recommended at all times. 2 EZ mode has no effect when no array is defined. 3 Disabling EZ for RAID 0 and LARGE is strongly recommended. 7 www.addonics.com Technical Support (M-F 8:30 am 6:00 pm)

Configuring the Port Multiplier Using the JMicron RAID Manager Windows users may install the JMicron HW RAID Manager application located on the SATA Controller CD, or download it from http://addonics.com/drivers/driver_list.php. In the CD, browse to Configuration Utilities JMB393. Mac and Linux users may download those versions of the same utility from http://addonics.com/drivers/driver_list.php under Port Multiplier & Hub. The JMicron RAID Manager can be used to create, modify, and monitor the health status of the RAID drives, and provide status alerts with dialog boxes and even email. When configuring the RAID mode using the RAID Manager application, it is strongly recommended to leave the dip switch in the factory default setting. Setting or Modifying the RAID Mode This procedure briefly describes the steps for using the Jmicron RAID Manager's Basic Mode to create an array. The example shown is a LARGE set. There are other options available in the Advanced Modes, including building arrays using specified drives, setting up email notifications, and updating the firmware which are not discussed in this user guide. After starting the Jmicron RAID Manager, the first screen will show the status of any Port Multipliers detected and any drives connected. Shown below is a Port Multiplier with a variety of five drives connected: On the left pane is Controller 1 which is the first port multiplier detected by the software. Shown in a tree view are the five drives, listed as P0-P4. These are currently individual drives. On the right pane is a listing of the drives and below that is a graphical view of each drive. Disk 1 through Disk 4 indicate which physical port the drive is connected to. For the AD5HPMSXA, AD5HPMRXA-E, and AD5HPMREU this refers to ports P0-P4. On the CPR5SA unit, this refers to HD0-HD4. On the AD5EHPMEU3 this refers to D1-D5. On RAID Tower products this relates to the drives mounted left to right or top to bottom, except in cases where a drive map is included showing otherwise. Phone: 408-453-6212 Email: www.addonics.com/support/query/ 8

Next, click the Basic RAID Configuration tab and select the type of RAID desired. Note that RAID 1 is currently disabled as an option since more than two individual drives are available, and DELETE ALL RAID is disabled since there are currently no arrays to delete. Shown below is the same set of drives being selected as a LARGE array. Finally, click Apply. The Jmicron RAID Manager will confirm the operation with a reminder that existing data on the drives will be lost, then perform the RAID configuration and report with a dialog box when it is complete. 9 www.addonics.com Technical Support (M-F 8:30 am 6:00 pm)

The RAID and Disk Information screen (shown when the program was launched) will now show the Port Multiplier with an Array. The drives are now listed as M0-M4, indicating they are members of the array. If spares are present (individual drives added later, and the EZ switch is in the OFF position), they would be listed as S0, S1, etc. On the right pane, the RAID Level, status, capacity and members that are online are listed. Status will show Normal (all members on line), Degraded (a fault-tolerant array with a drive failure needing service), Rebuilding (a fault-tolerant array in the process of reconstructing lost data onto a spare) or Broken (an array that has lost all data). In the event of a drive failure, the Jmicron RAID Manager will present a dialog box such as the one shown below, even if it is currently minimized to the system tray: 10 Phone: 408-453-6212 Email: www.addonics.com/support/query/

Contact Us www.addonics.com Phone: 408-573-8580 Fax: 408-573-8588 Email: http://www.addonics.com/sales/query/