Chapter 2 BladeStation Enclosure

Similar documents
Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

Chapter 6 Cubix SP1 Blade Server

Xpander Rack Mount 8 5U Gen 3 User Guide

HostEngine 4U Host Computer User Guide

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

Junos WebApp Secure 5.0 Hardware Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Xpander Desktop Elite Gen 3 User Guide

Rack Installation Instructions

Xpander Rackmount Elite Gen 3.0 User Guide

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

HostEngine 3U Host Computer User Guide

CHASSIS INSTALLATION GUIDE

EMC1600 Series Media Converter and Ethernet Extender Chassis

JanusRAID SA-6692J Hardware User Manual

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

IBM. Rack Installation Instructions

HostEngine 4U Host Computer User Guide

HostEngine 4U Host Computer User Guide

HostEngine 5URP24 Computer User Guide

DMC-1000 Chassis-Based Media Converter

Rack Installation Instructions

Replacing an Advanced Power and Cooling (APC) Unit

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

Managing Individual Components

Installation and Maintenance

CVH Slot Media Converter Chassis Quick Installation Guide

1 Getting Started Installing & Configuring

OV-MCR116. Media Converter Chassis System. User s Manual

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Oracle <Insert Picture Here>

Arion PDU : Intelligent Power Distribution User Guide for 24xC13 Outlet Monitored PDU

Dell MD1280 Storage Enclosure Getting Started Guide

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

System Storage EXP3000 Rack Installation Instructions

Perle MCR200 Installation Guide

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

easyraid Q24P2-U4R4 Hardware Manual

LevelOne KVM User Manual. 17 Modularized KVM Console V

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Snap Server 4400 Power Supply

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Installation Job Aid for VSP 4850GTS

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

DKP-115/117/119-Fe Single Rail Console with Modular KVM Switch User Manual

Installing the Cisco AS5400XM Universal Gateway

Sivy SA-4327S Hardware User Manual

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch

VXI-SC-1000 CARRIER MODULE

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

1. Unpacking the System

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Rack Installation Instructions

Installing the Cisco SFS 3504 Server Switch

SGI InfiniteStorage 120

User Manual LKS-CD17DR LKS-CD19DR. 17 LCD Dual Rail Console Drawer with Modular KVM Switch. 19 LCD Dual Rail Console Drawer with Modular KVM Switch

Installation Job Aid for Avaya Virtual Services Platform 8400

FreeNAS MiniandMiniXL Basic Setup Guide. Version 2.1

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

User s Guide. for xmac mini Server 2H Thunderbolt -to-pcie Expansion System and 1U Rack Enclosure for Mac mini With Thunderbolt Port

QUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)

Unicorn 15 / 17 / 19 / 19W Single Rail Console with Modular KVM Switch User Manual

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Installation Job Aid for VSP 4450GTX-HT- PWR+

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

Epson SureColor F6070 Setup Guide

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

Installing the IPS 4345 and IPS 4360

Programmable Controller IC697ACC721/724/744

Upgrading and Servicing Guide

N3240 Installation and Setup Instructions

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Replacing the Power Supply

Installing the Cisco MDS 9020 Fabric Switch

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL

Power Enclosure Components

System Storage DS3950 Quick Start Guide

Power Supply and Fan Module Installation

Hard Drive user manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

Field Service Guide Supplement for the NS 7000/030

Liebert XDA Air Flow Enhancer. User Manual

The SC812/SC812L Chassis Series Installation Guide

16Hi HARDWARE INSTALLATION GUIDE

Gemini 15 / 17 / 19 / 19W Dual Rail Console with Modular KVM Switch User Manual

Upgrading and Servicing Guide

8 Port Rackmount USB VGA KVM Switch w/ Audio (Audio Cables Included) StarTech ID: SV831DUSBAU

Rack Mount LCD KVM Assembly. Installer/User Guide

Transcription:

Chapter 2 BladeStation Enclosure Cubix BladeStation is an enclosure that provides power and cooling to multiple Cubix Blade Servers. It consists of a steel case, a mid-plane, an Input / Output (I / O) panel, identification switches and fans. The 6U high BladeStation is 25.5 inches deep with the external fans. BladeStation fits inside a standard, 19-inch rack mount cabinet. With redundant, hot-plug 220Volt AC power supplies (as illustrated below), BladeStation weighs 40 lbs. Technical Specifications Dimensions RETMA-compatible rack mount enclosure 19 (482.6mm) wide x 10.5 (266.7mm) high (6U) x 25.5" (647.7mm) deep Weight 40 lbs (15 kg) with redundant AC power supplies Operating 0 to 30 Celsius (32 to 86 Fahrenheit) temperature Environment 5% to 80% non-condensing humidity Fans Airflow is front to rear using two, hot-swap 300 cfm fans (total 600 cfm) at the rear Power Two auto-ranging, load-sharing power supplies support up to 6 Blade Servers in BladeStation from a power source that Rear I / O Panel Cable Tunnel Option provides 190 to 264VAC power at 8Amps. Dual USB port for keyboard and mouse One video DB-15 port Two fan power connectors DIP switches for site, rack and chassis identification Optional cable tunnel located beneath BladeStation for running cables from front to rear or vice-versa adds 1 (25.4mm) to the height of each BladeStation for a total height of 11.5 (292.1mm)

Unpacking and Rack Mounting Procedure 1. Remove BladeStation from its packaging as shown below. First, remove the power cords, drives and peripherals from the top of the packaging (A). Next, remove the power supply packaging (B) and then the power supplies from the packaging (C). Remove the two packing retainers (D). Remove the BladeStation enclosure (E) and remove the plastic from the enclosure (F). 2. Remove the singlewide blade(s), if any, from packaging as shown below. Remove the two packaging retainers (G). Lift the blade from the package (H). Remove the plastic from the blade (I). 3. Remove the doublewide blade(s) and hot-plug drives, if any, from the packaging. The box at the top (J) contains the drives. Remove it and set it aside. Remove the two packaging retainers and the blade (K and L). Remove the plastic from the blade and drives (M). 4. Install the mounting plates on the left and right side at the rear of the cabinet before attempting to mount BladeStation in the rack mount cabinet. 5. Mount BladeStation in the rack mount cabinet by installing the center screw first on both the left and right sides at the front of BladeStation. The illustration at the right shows only the front of BladeStation mounted properly in the rack mount cabinet.

6. Once you have mounted the plates using all three mounting screws at the rear of BladeStation, you can mount BladeStation in the rack mount cabinet. Again, install the left and right center screws first. The illustration at the right shows the rear of BladeStation installed properly in the rack mount cabinet. 7. Mount the AC power supplies within the enclosure. See the Power section of this chapter for detail on removing and replacing a redundant, hot-plug AC power supply. Do not plug in the power cords for the power supplies yet. 8. Mount a blade in the BladeStation enclosure. See Chapter 4 for detail on removing and replacing Cubix blades. If this is a doublewide blade with hot-plug drives, be sure to mount the drives as specified by the labels inside the enclosure. 9. Mount the hot-plug SCA drives into the doublewide blade. See Chapter 5 for detail on removing and replacing SCA drives. 10. Mount the other Blade Servers in the BladeStation enclosure. 11. Connect KVM, USB peripherals and network cables. See Chapter 5 and Chapter 6 for detail on connecting cables. 12. Mount the filler panels in the BladeStation enclosure wherever you have not installed Blade Servers. These filler panels assure proper airflow across the Blade Servers in the BladeStation enclosure. Warning: Cubix ships filler panels to assure proper airflow across operating Blade Servers. Make sure all filler panels are in place before powering up the BladeStation enclosure. Check the fan power cables at the rear of the unit. Both cables should be securely connected before applying power to the enclosure. Warning: Do not apply power to BladeStation unless both fan power cables are securely connected to the rear I/O panel. 13. Apply power to the BladeStation enclosure. Use the procedure below: Power AC Power Supply To install or replace an AC Power Supply, use the following procedure: 1. Support the power supply with one hand while you guide it into the power supply bay with your other hand. 2. Push the power supply all the way in until it blind mates at the rear. 3. Hand-tighten the screws at the top and bottom of both power supplies. 4. Plug in the 220VAC power cords. 5. Switch on the power supplies.

To remove an AC Power Supply, use the following procedure: 1. Switch off the power supply. 2. Hand-loosen the screws at the top and bottom of both power supplies. 3. Grasp the front handle of the power supply bay and tug the power supply toward you. 4. As you draw it toward you, support the power supply with the other hand. Warning: Do not remove a power supply for any length of time. Leave the power supply in the BladeStation enclosure to assure proper ventilation until you are able to replace it with a new power supply. Fans BladeStation features two, redundant 300 cubic feet per minute (cfm) system fans, which ventilate air from front to back, for an enclosure total of 600 cfm. These fans are hot swappable. For details on removing and replacing fans, see the illustration and the procedure listed below. Behind each fan is a set of baffles that close in the event a fan fails. This ensures that airflow travels only through the working fan. To remove and replace a system fan while BladeStation is running, use the following procedure: 1. Disconnect the fan s two-pronged power connector. 2. Remove the mounting screws holding the fan to the enclosure at the outside edges of the fan. 3. Remove the fan. 4. Replace the fan.

5. Replace the four screws holding the fan to the enclosure at the outside edges of the fan. 6. Connect the fan s power connector. If the enclosure already has power, the fan will start up and run. Rear Input / Output (I/O) Panel Use the BladeStation rear I/O panel to connect the fan power and KVM switch. The panel also has three banks of switches to identify the location of the site, rack and BladeStation enclosure. The following illustration shows the detail of the BladeStation rear I/O panel components. Fan Power The rear I/O panel contains outlets for the chassis fans. Make sure that both fans are plugged securely into these power outlets before applying power to the BladeStation enclosure. KVM Switches Each BladeStation enclosure has a built-in KVM switch that supports a single keyboard, video and mouse per enclosure. Connect multiple BladeStations to a single KVM switch using the video port and the USB ports for keyboard and mouse. If the KVM switch supports KVM-over-IP, then you can connect it for this purpose as well. Cubix has qualified the Avocent AutoView 2000R (AV2000R) KVM switch for use with BladeStation. It supports multiple BladeStations connected to each switch and also supports two administrators using KVMover-IP at any one time. After you have mounted the AV2000R in the same rack mount cabinet with the BladeStation, use the following procedure to connect the two: 1. Connect the DSRIQ-USB module to the BladeStation s rear panel video port (DB-15) and USB port. This module is illustrated below.

2. Run a cable (e.g., Cat5) from the DSRIQ-USB module s RJ-45 port to an RJ- 45 port on the AV2000R s rear panel. See the illustration below for detail. 3. Repeat this procedure for each BladeStation mounted within the same or a nearby cabinet. Identification Switches Cubix provides three banks of eight Dual In-line Package (DIP) switches to identify location, rack and the BladeStation enclosure. The Cubix Management Controller (CMC) on each blade can read this information when it boots. For all switch positions, down is ON and up is OFF. You need not concern yourself with these switches if you intend to use Dynamic Host Configuration Protocol (DHCP) to assign an IP address to each blade s CMC module. If you plan to assign IP addresses automatically using DHCP, then set Bank 1, Switch 3 OFF, and ignore these switches. You also do not have to concern yourself with these switches if you set the IP addresses within the CubixVision configuration tab. You can see more detail about these IP address settings in Chapter 8, Management. Each singlewide blade position within the BladeStation enclosure provides an address to the CMC module mounted on a blade in that position. For detail on viewing the CMC using Microsoft Internet Explorer (IE) 6, Service Pack 1, see Chapter 8, Management. For example, the CMC module on the blade in the leftmost position of the first BladeStation enclosure always has the address of 10.0.0.1. The CMC module on the second blade has the address of 10.0.0.2, and so on through 10.0.0.6. The CMC modules on the doublewide blades have addresses as follows: 10.0.0.1, 10.0.0.3 and 10.0.0.5.

Once you have booted each blade and can see the CMC module using IE6, you can change the IP address for each CMC module. For detail on this procedure, see Chapter 8, Management. If you do not plan to use DHCP, use the switches according to the following guidelines: When Cubix ships a single enclosure, then the default factory setting for any BladeStation enclosure is Bank 1 / Switch 1 UP (OFF) and all other switch settings DOWN (ON). This assigns an IP address to the CMC module on each blade inside a BladeStation within the range of 10.0.0.1 through 10.0.0.6. If you are deploying two or more enclosures (for example, five) at a single location for mounting in the same rack or cabinet, then the settings are as follows: o The first enclosure switches are set default as listed above. o The second enclosure switches are set Bank 1, Switch 1 OFF and Bank 3, Switch 8 OFF. All other switches are set ON. This provides the CMC module on each blade inside the BladeStation with an IP address within the range of 10.0.0.17 through 10.0.0.22. o The third enclosure switches are set Bank 1, Switch 1 OFF and Bank 3, Switch 7 OFF. All other switches are set ON. This provides the CMC module on each blade inside the BladeStation with an IP address within the range of 10.0.0.33 through 10.0.0.38. o The fourth enclosure switches are set Bank 1, Switch 1 OFF and Bank 3, Switch 7 and 8 OFF. All other switches are set ON. This provides the CMC module on each blade inside the BladeStation with an IP address within the range of 10.0.0.49 through 10.0.0.54. o The fifth enclosure switches are set Bank 1, Switch 1 OFF and Bank 3, Switch 6 OFF. All other switches are set ON. This provides the CMC module on each blade inside the BladeStation with an IP address within the range of 10.0.0.65 through 10.0.0.70. Allocate a default IP address for the CMC modules using these settings. The IP address range is fixed to start at 10.0.0.1 and end at 10.128.0.6. The rightmost four switches on bank 1 as well as banks 2 and 3 provide site, rack and enclosure numbers. As discussed earlier, the management controllers identify blade position within the BladeStation enclosure using numbers from 1 through 7.

Bank 1. The first four switches of bank 1 provide switch options that apply to the BladeStation enclosure. See the table below for an explanation of each position. Description DIP DIP Switch Setting Switch Position UP (OFF) DOWN (ON) KVM Switch Connected 1 Disable Enable ~ Reserved ~ 2 CMC derives IP address from switch settings ~ Reserved ~ 4 Bold = Factory Default 3 Use DHCP Use Switch Settings The next four switches start the sequence for Location ID. See the table at the end of this chapter for switch settings. Bank 2. The next eight switches complete the location number. If a user requires more than sixteen racks at a physical location, he can subdivide the site and assign multiple locations to a physical site. See the table below for switch settings. Bank 3. The left 4 bits of the rightmost bank provide the rack number from 0 through 15. The next four switches provide the BladeStation enclosure with an identification number from 0 to 15. See the table below for switch settings.

10.0.0.6 Each blade's position from 1 thru 6 in BladeStation determines that blade's CMC ID. Add the 10.0.0.22 The first BladeStation's ID is always 0, which is all switches ON. CMC ID to the ID 10.0.0.38 The second BladeStation's ID is 1, which is Bank 3, Switch 8 OFF. of the BladeStation 10.0.0.70 This provides the CMCs on the blades in the second BladeStation with to arrive at the IP 10.0.0.134 IP addresses that range from 10.0.0.17 through 10.0.0.22. The third address of the blade 10.0.1.6 The first rack's ID is 0, the second is 1 and so on. If BladeStation's within a BladeStation 10.0.2.6 the first rack has 6 BladeStations with 6 blades each, ID is 2, enclosure. 10.0.4.6 then the first blade in the first BladeStation in the second which is 10.0.8.6 rack has an IP address of 10.0.1.1. The switch setting Bank 3, 10.0.16.6 The first location's ID is 0, the second is 1 on this Switch 7 10.0.32.6 and so on. If location #10 has a rack with six BladeStation OFF. This 10.0.64.6 BladeStations inside, the switch setting on is Bank 3, provides the 10.0.128.6 the sixth BladeStation is Bank 2, Switches 5 Switch 4 CMCs on 10.1.0.6 and 8 OFF. This provides the blades inside OFF. the blades 10.2.0.6 with an IP address range of 10.0.144.1-6. in the third 10.4.0.6 10.8.0.6 BladeStation with IP 10.16.0.6 addresses 10.32.0.6 that range 10.64.0.6 from 10.128.0.6 10.0.0.33 -- Each IP address at the left through -- corresponds to a switch 10.0.0.38. -- setting on the 3 Switch -- Banks below. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Switch Bank 1 Switch Bank 2 Switch Bank 3 Function* Location ID Rack ID Enclosure ID Blade ID** Add these two to arrive at Add these two to arrive at Add these two to arrive at 10. 0. 0. 6 Notes: All switch settings are binary. * Function settings appear in the Functions Table on the previous page. ** Each blade's position from 1 thru 6 in BladeStation determines that blade's CMC ID.

Move a Blade From BladePoint to BladeStation 1. Place BladePoint on a stable surface such as a bench. 2. Loosen the two twist-lock screws at the rear of BladePoint cover panel. 3. Remove the 8 screws securing the cover panel to BladePoint. 4. Remove the cover panel. 5. Use a Phillips screwdriver to remove the four screws on the blade cover panel. 6. Remove the Auxiliary Power Cable from the blade and power junction at the rear of BladePoint. See the illustration at the right for detail. 7. Remove the Drive Data Cables from the blade. 8. Remove the Drive Bracket Retaining screws to remove the drive(s). 9. Remove the four screws holding the drive(s) to the drive bracket. 10. Loosen the two retaining screws at the front of the blade holding it in BladeStation. 11. Gently tug the blade toward you and remove it from BladePoint. 12. Set the blade on the bench and remove the CMC module jumpers as shown in the illustration below. 13. Mount the drive(s) to the roof of the blade using three screws. 14. Connect the drive data cable(s) from the drive to the blade. 15. Connect the drive power cable(s) from the drive to the Auxiliary Power connector. 16. Remove the filler panel or blade from BladeStation. 17. Slide the blade gently into BladeStation, making sure that all the cables clear the neighboring filler panel or blade. Note: Do not leave the space where you intend to put the blade empty for too long while BladeStation is running because it may allow the blades to overheat. Removing the filler panel or blade just before you replace it with a blade assures that all the blades in BladeStation have proper cooling.

Go to Chapter 3 Blade Peripherals Or Return to Table of Contents