Version: LED2-Matrix Display. LED2 Matrix Display. User Manual

Similar documents
LED-Matrix Display. LED2 Matrix Display. User Manual. Version 2.0

UPS SNMP Watch User manual

CS121 AUX Adapter for AS 400 UPS interface CS 121 AUX RJ11 6-pol Layout:

SITEMANAGER II. User Manual English. Version:

UPS Management Software

SITEMONITOR II. User Manual English. Version:

Description UPS Management Software

Ethernet-Adapter for the control and the management of UPS Facilities

UPS-Management Software

ADN. System Installer. Instruction manual

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

CRU Configurator. User Manual for Windows. Features

CS121 SPI_II / BACS SPI_II

CRU Configurator. User Manual for Mac OS X. Features

Version: UPS WEB/SNMP MANAGER. CS121 Series. Additional Components (CS121 Extensions) User Manual English

UPS MANAGEMENT SOFTWARE

ALL0236R. User s Manual. Wireless N Extender V1.0. Table of Contents

Quick Installation Guide

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

Installation Guide. ProView. For System Center operations Manager ProView Installation Guide. Dynamic Azure and System Center insights

Ethernet-Adapter for the control and the management of UPS Facilities. CS141Pro and MODBUS with Battery Management Function BACS

ADVANCED OPERATOR PANEL (AOP)

Bar Code Discovery. Administrator's Guide

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1

UPS WEB/SNMP MANAGER. CS121 Series. User Manual English Rel.52

Q VLAN User s Guide

FES BMS CONTROL MANUAL

All the registered trademarks referred to this manual are belonging to their respective companies.

Redirector User Guide

Content. 1. SOFTWARE RCCMD for IBMs AS400 Chinese and Korean USW Version 2.07c RCCMD 3

Microsoft Dynamics GP. Extender User s Guide

GSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface

Manual# Installation Manual SDU 410. Safety Shutdown Unit

AT-S79 Version ( ) Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

AT-S79 Version Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

ivms-4200 Access Control Client User Manual UD00895N

UNMS II UPS Network Management System

LCD62. Keypad. User Manual

CS141 SNMP / WEB / MODBUS MANAGER

TECHILA WORKER INSTALLATION GUIDE WINDOWS ADMINISTRATOR DOCUMENT

MusicTel-Net/Net+ Installation and Operation Manual

Microsoft Dynamics GP. Inventory Kardex

Using Templates. 5.4 Using Templates

Leaf Aptus-II. User Guide

Toad Data Point - Professional Edition. The Toad Data Point Professional edition includes the following new features and enhancements.

Integrate APC Smart UPS

LogTunnel Deployment Guide

ezfinder User Guide Version 1.0

TA Instruments TA Update. Getting Started Guide

User Manual WatchPower

Share Online 2.0. Copyright 2007 Nokia. All rights reserved.

Tanium Asset User Guide. Version 1.1.0

Cascade Configuration Tool

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Innovative Electronics for a Changing World INDEX

Toad Edge Installation Guide

NEC ESMPRO Manager Monitoring Tool Installation Guide

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

One Identity Manager 8.0. Administration Guide for Connecting to a Universal Cloud Interface

pakedgedevice&software inc.

PCMCIA Flash Card User Guide

MAG. Explorer. Reference for the latest revision of the Magnetek Explorer software

LED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module)

Setup manual VU COM. VU COM - version V2.04. Product reference number:

Manual Version: V1.00. Video Decoder User Manual

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

FES BMS CONTROL MANUAL

Mile Terms of Use. Effective Date: February, Version 1.1 Feb 2018 [ Mile ] Mileico.com

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

UPS WEB/SNMP MANAGER. CS121 Series. User Manual English Rel.52

User Manual WatchPower

SK hynix Drive Manager Easy Kit. Installation Guide

Cisco C880 M4 Server User Interface Operating Instructions for Servers with E v2 and E v3 CPUs

WL556E Portable Wireless-N Repeater

factory field upgrade

Serial to Ethernet Converter

MyCreditChain Terms of Use

TIE1.80InstallationGuideUK

Destinator SP for Symbian User Guide. Destinator Technologies. Destinator SP for Symbian User Guide 1

Content. 1. UPSMAN with RCCMD Huge savings on RCCMD licenses. 2. CS121 B B as in BUDGET

Deploying Devices. Cisco Prime Infrastructure 3.1. Job Aid

Cisco TelePresence IP GW MSE 8350

BlackBerry Wireless Handheld Getting Started Guide

Galaxy Shore Connection 500 kva. Operation 04/

Esensors. Websensor User Guide. Save trees. Print only when necessary

UPS COMMUNICATION Web Card

MonitAir Program Waitt Radio Networks

Profiles (permissions) Document Version: V1.6 March 2018

One Identity Manager Target System Synchronization Reference Guide

The HPV Explorer is a serial communication program used to work with the HPV 600/900 s parameters via a computer s serial port

One Identity Manager Administration Guide for Connecting to SharePoint

IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar

Xcalibur Global Version 1.2 Quick Configuration Guide Document Version 3.0

Installation Guide. RADview-EMS/NGN (PC) PC-Based Element Management System for NGN Applications Version 1.8

BlackBerry Wireless Handheld Getting Started Guide

E-Series Cabling E-Series Hardware

Staff User s Guide Task Manager. Version 22

Mobile Connect for USA Mobility Pagers for BlackBerry

Transcription:

Version: 2016-08-18 LED2-Matrix Display LED2 Matrix Display User Manual

www.generex.de Revision History Date -001-011 -012-013 -014-015 -016 First Release. New Release. Updated LED_2 screenshots Updated LED & UPS State Messages Configuration Added: UPS standard variables Added: SiteManager II variables Added: Buzzer integrated 09/2006 05/2008 10/2008 01/2009 02/2009 11/2011 08/2012 Copyright Statement for Intellectual Property and Confidential Information The information contained in this manual is non-conditional and may be changed without due notice. Although Generex has attempted to provide accurate information within this document, Generex assumes no responsibility for the accuracy of this information. Generex shall not be liable for any indirect, special, consequential, or accidental damage including, without limitations, lost profits or revenues, costs of replacement goods, loss or damage to data arising out of the use of this document. Generex the manufacturer of the BACS products undertakes no obligations with this information. The products that are described in this brochure are given on the sole basis of information to its channel partners for them to have a better understanding of the Generex products. Generex allows its channel partners to transfer information contained in this document to third persons, either staff within their own Company or their own customers, either electronically or mechanically, or by photocopies or similar means. Generex states that the content must not be altered or adapted in any way without written permission from Generex. It is agreed that all rights, title and interest in the Generex s trademarks or trade names (whether or not registered) or goodwill from time to time of Generex or in any intellectual property right including without limitation any copyright, patents relating to the Products, shall remain the exclusive property of Generex. Generex will undertake to deal promptly with any complaints about the content of this document. Comments or complaints about the document should be addressed to Generex Systems GmbH. Copyright of the European Union is effective (Copyright EU). Copyright (c) 1995-2016 GENEREX GmbH, Hamburg, Germany. All rights reserved. LED2 User Manual 2

Contents Introduction Overview... 4 Display... 4 Configuration LED-Matrix Configuration... 8 Configuring the sender... 9 Mode 1: Send UPS State and Data automatically... 9 Mode 2: Send RCCMD Messages from UPS Events... 10 Appendix... 14 LED2 User Manual iii

Introduction Overview The LED Matrix is based on the CS121 web-adapter. Please, refer to the CS121 user manual for an explanation regarding the configuration of the network settings, event handling etc.. The CS121 user manual will be delivered with the LED Matrix or can be downloaded from our website: CS121 User Manual This document describes the special features, which are unique to the LED Matrix, that do not pertain to the standard CS121 and provides instructions, how to operate the LED Matrix. The LED Matrix is a remote display unit for relaying either UPS status and values or customized RCCMD messages, which can be operated via the ethernet. Any CS121 web-adapter and any other RCCMD 2 compatible products can send text messages and/or environmental data values to the LED Matrix and can add audible alarms for warnings, that require immediate attention (optional, SM-Buzz connected to AUX port only). Display Depending on the length of the LED Matrix display, from 4 up to 30 characters can be displayed at one-time. If the intended message is too long for the number of displayable characters, the message will be scrolled automatically through the display. Figure: LED2-Matrix display, short version LED2_40 The desired messages can be either send from the CS121 devices in the network or via RCCMD of any other network enabled devices. LED2 User Manual 4

The LED Matrix is displaying the current text on the status site LED Matrix. Figure: LED Display Status, Text and Buzzer Page Use the button Toggle Buzzer to set the internal buzzer on or off. The display will be refreshed all the time, so that the messages can always be monitored via web-browser. For example: The text above is generated by the configuration site Automatic Mode, cleft 2, string: UPS%n Output Frequency: %1.1Hz. Figure: LED Matrix Display Settings & Templates In the LED settings are the following options possible: Display Type LED2_40 or LED2_130 depends on LED type LED2 User Manual 5

UPS Type 1 or 3-phase, depends on connected sender type (1 or 3-phase UPS). Note: We recommend to use the LED2_130 for 3phase UPS, because the LED2_40 is pre-configured for 1-phase UPS by default only. Number of connected UPS Number of connected UPS, this specifies how many CS121/UPSMAN are permitted to send messages (10 at most) Refresh Time in seconds Definition of the term, how long a message will be displayed until the next will be Fonts Default is SS7, more fonts are available Display Mode Hold or flash You can add audible alarms for the standard events like Powerfail, Bypass Operation, Overload, Overtemperature, General Alarm and Communication lost. Optional: The GENEREX SM-Buzz can be connected to the AUX port of the LED Matrix. The alarm buzzer events are predefined. For further configuration information, please take a look into the CS121 User Manual The default messages and measurement values of the automatic mode are displayed in the LED templates. You can modify them if necessary. Status - UPS%n Status: %1 (% is a variable, which can be replaced by the CS121 sender and its current measurement value) Input Voltage - UPS%n Input: %1V %2V %3V (if 3-phase) Input Frequency - UPS%n Input Frequency: %1.1Hz Battery Voltage - UPS%n Battery Voltage: %1V Autonomy Time - UPS%n Autonomy Time: %1 Min. Output Voltage - UPS%n Output Voltage: %1V Output Frequency - UPS%n Output Frequency: %1.1Hz LED2 User Manual 6

The firmware version 3.88 (or higher) contains a new configuration menu, that provides the option to configure the state in the desired language. Figure: LED & UPS State Messages (italian) During the sending of a message, the following will be registered in the log file of the CS121/UPSMAN sender: RCCMD is connecting to 192.168.202.101:6002 (RccmdConn01) RCCMD finished to send. OK (RccmdConn01) LED2 User Manual 7

Configuration LED-Matrix Configuration The first configuration step is to choose the LED Display in the UPS Model & System menu. Figure: LED-Matrix UPS Model & System Page Note: LED Matrix devices built before 08/2012 require the configuration items Exchange COM Ports set as active. Devices after 08/2012 this function has to be disabled.. As second step follows the RCCMD Listener settings on the Network & Security Page. The RCCMD Listener is enabled in the default configuration of the LED Matrix and its Port is set on 6002. It is recommended to keep this settings. The other configuration parameters should be adjusted to the local network settings using TELNET, a terminal program or a web-browser. Add the configuration route 10.10.10.10 (via route add 10.10.10.10 ip-address of your local host). For further setting information of the SNMP web-interface, please take a look into the CS121 User Manual Figure: LED-Matrix Configuration Page LED2 User Manual 8

Configuring the sender Note: You have to decide between one of the following modes. Do not connect senders in different modes to the same LED Matrix! You can run the LED Matrix in Automatic Mode or either in the Manual Mode. We want to explain subsequent, how to set up the CS121 or rather the UPSMAN (as senders) and the LED Matrix. Every RCCMD sender (CS121, UPSMAN and any other kind of licenzed RCCMD senders) is able to send messages to the LED Matrix. Every RCCMD client is also able to send messages via scripting-language. Mode 1: Send UPS State and Data automatically In order to display the UPS status and measurement values in the LED Matrix, you need to set up the following configuration in the CS121 Network & Security configuration page of the web-interface. Note: These settings are for the CS121/UPSMAN senders only and not for the LED Matrix! Click the Enable LED Display Sender box Enter a unique Number in the range from 0 to 9 in the field LED Display Sender ID. This Number is used to identify this device on the LED-Matrix Enter the IP Address of the LED-Matrix in the field LED Display Listener Address Note: Remember to click the Apply button to confirm your changes. After all changes are done, click the Save Configuration Page and click Save, Exit & Reboot. In this mode all data and measurement values of the UPS, which got the LED mode activated, will automatically displayed. For the use of the Automatic Mode is a firmware of 3.80 or higher required. LED2 User Manual 9

Mode 2: Send RCCMD Messages from UPS Events Example: Configuring the CS121 to send event messages to the LED Matrix. Set up the sender (CS121) manually with the text message and the accordant syntax as you can see below. If you want to display the autonomy time of the UPS on the LED Matrix, you need to set up the following in the menu Events and Alarms / Powerfail: Click the Add new job button and select the function Send RCCMD Command to remote client. Set up the ip-address of the destination (LED Matrix) and the port 6002 into the job parameters. Note: 6003 is the default port, which is reserved for all the other RCCMD commands. As described before, the 6002 port is the default Listener port of the LED Matrix. The command-line is the following: Examples: 1. UPSCMD 2000 Welcome to GENEREX " : The text Welcome to GENEREX will be displayed until an other text is received. 2. The configuration below will display the text BATT directly and onetime in accordance to the selected circular button, after the UPS is in Battery Mode. LED2 User Manual 10

3. If you want to display further messages on the LED Matrix, click the Apply button to commit the current job and return to the event overview. Click the Add new job button and set up your desired job. In the example above are the settings for the display of the variable #ATIME, the balance time of the batteries, recorded. This time will be displayed with a delay of 30 seconds in a 30 seconds interval. The balance time of the batteries are the autonomy time in minutes. Please take a look into the Appendix (page 14), where you will see the UPS standard variables. If you want to add a text, e. g. a dimension unit, you can execute it, if you separate the command with a blank: UPSCMD 2000 #ATIME Minutes 4. To send an all-clear message to cancel an alarm like Power restored after a Powerfail, just select the event Power restored in the event overview and record a suitable text like Grid Okay. LED2 User Manual 11

Note: Remember to click the Apply button to commit your changes every time. After all changes are done, click the Save & Exit and Reboot button in the Save Configuration menu. Tests: If the CS121 is connected to the UPS, the green LED is flashing and the web-browser is displaying measurement values, tests can be started, like UPS in battery mode or to send test-signals out of the Events & Alarms section of the CS121/UPSMAN. 5. ALARM BUZZER: Switching the alarm buzzer at the LED Matrix, a CS121 RCCMD execute signal is needed. Set up the destination (ipaddress of the LED Matrix) and the port 6002. Use the syntax: AUX 3 1 to switch on, AUX 3 0 to switch off. Buzzer ON: Buzzer OFF: Every RCCMD sender (CS121, UPSMAN and any other kind of licenzed RCCMD senders) is able to send messages to the LED Matrix. Every RCCMD client is also able to send messages via scripting-language. Use the RCCMD syntax to switch off: rccmd -s -a <your LED MATRIX IP address> -p 6002 -se "EXECUTE AUX 1 0" LED2 User Manual 12

To switch on the alarm buzzer via UPSMAN software: Please note, that every command is initiated with 6. Try to test the alarm buzzer in the menu AUX & TEMPMAN Status with the Switch On buttons. Do not connect several senders with different configurations to one LED Matrix! Basically the LED Matrix is running in the automatic mode OR the manually mode! Every other settings of the LED Matrix according to the features of the CS121 Please take a look into the CS121 User Manual for further information. LED2 User Manual 13

Appendix UPS Standard Variables #STATUS #INVOLT0 #INVOLT1 #INVOLT2 #INCURR #BATTVOLT #TEMPDEG #AUTONOMTIME #BATTCAP #OUTPOWER0 (Last in %) #OUTPOWER1 #OUTPOWER2 #INFREQ0 #INFREQ1 #INFREQ2 #OUTFREQ0 #OUTFREQ1 #OUTFREQ2 #SECONBAT (Powerfail: seconds on battery) #MANUFACTURER #MODEL (defined value) #LOCATION (defined value) #ATTACHED_DEVICES (defined value) #POWER (defined value) #LOAD (defined value) #HOLDTIME (defined value) #RECHARGETIME (defined value) #LOCALTIME ("dd.mm.yyyy hh:mm") #DATE ("dd/mm/yyyy") #TIME ("hh:mm") #BATTINSTDATE ("dd.mm.yyyy") #AGENTSOFTREV (Firmware Version) #TEMP1 (SensorManager variables) #TEMP2 #TEMP3 #TEMP4 #TEMP5 #TEMP6 #TEMP7 #TEMP8 LED2 User Manual 14

#SM2_ANALOG0 (SiteManager II variables) #SM2_ANALOG1 #SM2_ANALOG2 #SM2_ANALOG3 #SM2_ANALOG4 #SM2_ANALOG5 #SM2_ANALOG6 #SM2_ANALOG7 All other variables depend of the type of UPS. ATTENTION!!! The manually display mode is not provided for CS121 Budget adapters! LED2 User Manual 15