Communication Interface

Similar documents
Com X 210, Com X 510 Technical Datasheet

Communication Interface

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Electrical network management. Schneider Electric. EM4200 Technical Datasheet

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

Gateways & Energy Servers

MultiTech Router Commissioning for Com X 200/210/510

Com'X 510. User Manual DOCA0098EN-03 04/2016

Com X 510 Energy Server User manual DOCA0098EN-07 07/2017

Energy Management Smart Panel

Com'X 510. User Manual DOCA0098EN-02 12/2015

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Gateways & Energy Servers

How can I. Implement a cost-effective energy monitoring system for small to medium buildings using Com'X 510?

PowerLogic EM4000 series

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Web-enabled DAQ System

PowerLogic power-monitoring units. iem3000 Series. Technical data sheet

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

StruxureWare Power Monitoring Expert 8.0 Data Center Edition

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Quick Installation Guide

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

Panoramic Power Installation and configuration guide

GS828-H. GPRS Data Logger

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

GS828. GPRS Data Logger

Schneider Electric Easy UPS 3S

SH2WEB24. Central unit module. Benefits. Description

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

More than 150 integrated application-specific functions

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Schneider Electric Easy UPS 3S

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Catalogue 2017 Digital system for Smart Panels. schneider-electric.com

iologik E1200H Series

iologik 2500 HSPA/GPRS/WLAN Series

Energy Web Server. Viale Borri 231, Varese - Italy. Cat. no: PM1WS255

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

IFE Ethernet Interface for One Circuit Breaker User Guide

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

LoRa Gateway Receiver User Guide

Installation/User Manual

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

See it. Control it. The TelPro Solution

Acti 9 Communication System

UCM 94/1 3G/GPRS Modem for RTU32 Series

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

SA2WEB24. Central unit module. Benefits. Description

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

DOCA0069EN 10/2016. Ecoreach Online Help. Version /2016 DOCA0069EN-04.

Table of Contents. PowerTag - Smallest Wireless Energy Sensor

Business continuity made easy

ENMAT Premium Data Logger User Manual

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

User Manual For TX204B/TX204G/TX306 Receivers

Ethernet Interface Module

ZBRN1. Main. Device short name

QUICK-START EMU M-BUS CENTER ENGLISH

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

SCADAPack FlowStation 110. Pump station controller

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

W315 - W320 remote management modules

Panoramic Power Installation and configuration guide

RAY-3 DATA LOGGER USER S MANUAL

HSPA+ WiFi Router with Voice

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

MODULAR CIRCUIT MONITORING SYSTEM

KX GPRS M2M I-NET. User s Guide. Version: 1.0. Date: March 17, KORTEX PSI 3 Bd Albert Camus Tel:

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Compact NSX communication

Product Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)

Compact NSX communication

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

MIC-2 Multi-instrument DATA SHEET

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

TM241CE40R controller M IO relay Ethernet

Advancing AiHD Cloud Solution

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

POWERWISE INDAC SETUP MANUAL

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

SenNet Registered trademark of Satel Spain Dataloggers series DL170 DL171 DL172.

WattmonMEGA Remote Monitoring & Control Platform

X-Log Expert Data Logger

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Enerlin'x. Communication system for Smart Panels

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Intech Micro 2400-A16-SD

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

TM241CE24T controller M IO transistor PNP Ethernet

Transcription:

Communication Interface Com'X 200/Com'X 210/Com'X 510 Technical data sheet

Communications & gateways Com'X 200 / 210 Energy data loggers Main functions 1. Measure 2. Connect 3. Save PB114855 Wireless Meter Temperature sensors Analogue sensors with 4-20 ma or 0-10 V adaptor PowerView Remote Zigbee Pulse energy meters GPRS/3G Internet Com X 200/210 Modbus multi-meters Ethernet or Wi-Fi LAN Ethernet Modbus TCP Circuit-breakers Power Monitoring Expert Wireless transmitters Gas meter Ethernet or Wi-Fi LAN Modbus Serial Line Analogue / digital IOs Zigbee wireless Water meters Data collector Collects and stores energy data from up to 64 field devices, connected to either: Ethernet TCP/IP field network. Modbus Serial line network (up to 32 devices). Embedded digital and analogue inputs. Field devices consist of : PowerLogic devices for power and energy monitoring. Masterpact or Compact circuit-breakers for protection and monitoring. Acti 9 protection devices, meters, remote controlled switches, etc. Water, Air, Gas, Electricity, and Steam consumption meters, from specialized manufacturers, delivering pulses as per standard (see table next page). Environmental sensors such as temperatures, humidity, and CO 2 levels in a building, providing analogue information. Data logging and storage capabilities include: Configurable logging interval, from every minute to once a week. Data storage duration of several weeks, depending on quanitity of of collected data. 2 PLSED310098EN

Communications & gateways Com'X 200/ 210 Functions and characteristics PB112041 Data publisher Batches of collected data periodically transmitted to an Internet server, as: XML files, for processing by StruxureWare web services, such as Facility Insights. CSV files for viewing in Excel or transformed for upload into programs such as StruxureWare Power Monitoring Expert or any compatible software. Support for Weather Sentry. Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi: Energy Server Com'X 200 data logger HTTP. HTTPS. FTP. SMTP. Additional functions PB114328 Gateway If selected by the user, the Com X 200/210 can also make all data from connected devices available in real-time: In Modbus TCP/IP format over Ethernet or Wi-Fi. For requests by an energy management software. Gateway to Zigbee device data by external Modbus TCP/IP clients. Modbus packets can be sent from managing software to field devices through Modbus serial line or Modbus TCP/IP over Ethernet. Energy Server Com'X 210 data logger Com'X 200/210 Commercial reference numbers Com'X 200 data logger 24 V DC or 230 V AC power supplied EBX200 Com'X 210 data logger 24 V DC power supplied UL rated Com'X Wi-Fi USB interface Com'X GPRS interface with SIM card for RSP only Com'X GPRS interface Com'X External GPRS antenna Com'X Zigbee USB interface EBX210 EBXA-USB-WiFi EBXA-GPRS-SIM EBXA-GPRS EBXA-ANT-5M EBXA-USB-Zigbee Please see your Schneider Electric representative for complete ordering information. PLSED310098EN 3

Communications & gateways Com'X 510 Energy server Main functions PB114856 Web browser Ethernet or Wi-Fi LAN Modbus Serial Line Analogue / digital IOs 1. Measure 2. Connect 3. Save PowerView Remote Temperature sensors Analogue sensors with 4-20 ma or 0-10 V adaptor Pulse energy meters Internet GPRS/3G Com X 510 Modbus multi-meters Ethernet or Wi-Fi LAN Ethernet Modbus TCP Circuit-breakers Power Monitoring Expert Wireless transmitters Gas meter Water meters Data collector Collects and stores energy data from up to 64 field devices, connected to either: Ethernet TCP/IP field network. Modbus Serial line network (up to 32 devices). Embedded digital and analogue inputs. PB114852 Field devices consist of : PowerLogic meters for power and energy monitoring. Masterpact, Powerpact, or Compact circuit-breakers for protection and monitoring. Acti 9 protection devices, meters, remote controlled switches, etc. Water, Air, Gas, Electricity, and Steam consumption meters, from specialized manufacturers, delivering pulses as per standard (see table at end of this document). Environmental sensors such as temperatures, humidity, and CO 2 levels in a building, providing analogue information. Data logging and storage capabilities include: Data logging period: configurable from every minute to once a week. Data storage duration: up to 2 years, depending on quanitity of collected data. Able to set time and send reset instructions to field devices. Embedded energy management software The Com X provides the end-user with immediate visibility into energy consumption throughout the site. As soon as the Com X is connected to the Local Area Network (LAN), several web pages are accessible via any standard web browser, (without plug-in or additional components). Energy dashboard comparing accumulated over time energy values (partial screen) These web pages display real-time data as it is collected, in easy to understand tabular and summary formats. In addition, users can get simple analysis of historical data in bar graph or trending formats. 4 PLSED310098EN

Communications & gateways Com'X 510 Energy server PB114327 Additional functions Data publisher Batches of collected data can also be periodically transmitted to an Internet server, as: XML files, for processing by StruxureWare web services, such as Facility Insights. CSV files for viewing in Excel or transformed or uploading to programs such as StruxureWare Power Monitoring Expert or any compatible software. Energy Server Com'X 510 data logger Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi: HTTP. HTTPS. FTP. SMTP. PB114854 Gateway If selected by the user, the Com X510 can make data from connected devices available in real time: In Modbus TCP/IP format over Ethernet or Wi-Fi. For requests by energy management software. Gateway to Zigbee device data by external Modbus TCP/IP clients. Modbus packets can be sent from managing software to field devices through Modbus serial line or Modbus TCP/IP over Ethernet. Real-time Trending. Custom Web Page Support. Raw data and measurements from one field device (partial screen) PB114853 Historical trending comparing multiple devices or multiple topics (partial screen) Com'X 510 Commercial reference numbers Com'X 510 energy server 24 V DC power supplied UL rated Com'X Wi-Fi USB interface Com'X GPRS interface SIM card Com'X GPRS interface Com'X External GPRS antenna Com'X Zigbee USB interface EBX510 EBXA-USB-WiFi EBXA-GPRS-SIM EBXA-GPRS EBXA-ANT-5M EBXA-USB-Zigbee Please see your Schneider Electric representative for complete ordering information. PLSED310098EN 5

Communications Com'X 200/210/510 Connectivity PB112047 Connectivity Modbus SL /RS-485 connections to field devices By cable with RJ45 connector. Connection points 1 Terminal block 2 RJ45 cable 3 Ethernet port #1 4 Ethernet port #2 2 Ethernet ports Used to either separate upstream connection from field devices network or to daisy chain Ethernet devices. RJ45 10/100BASE connectors. Static IP address. Ethernet port #1 Connection to Local Area Network (LAN). PoE Class 3 (802.3af) can act as main/backup power supply for the Com'X. DHCP client. Ethernet port # 2 Connection to field devices. DHCP cleint or server. PB114859 Power supply to analogue and digital outputs Outputs to supply sensors and inputs when Com X is supplied through 24 V DC input on top: 12 V DC 60 ma for digital inputs. 24 V DC for analogue inputs. Compliant with electrical switchboard environment (temperature, electromagnetic compatibilty). Power supply to analogue and digital inputs 2 inputs for analogue sensors PT100 or PT1000 temperature probes. Various sensors (humidity, CO 2, etc.) with 0-10 V output. Various sensors with 4-20 ma output 6 inputs for dry contact sensors or pulse counters Max 25 pulses per second (min duration 20 ms) IEC 62053-31 Class A PB112042 PB112044 Wi-Fi USB stick Wi-Fi USB stick As an alternative to publication over Ethernet, connects Com X to the site Wi-Fi router for regular data transmission. Can also be used for Com'X 510 configuration through one-to-one connection with laptop or tablet. Simply plugs into USB port 2 under front cover. GPRS/3G modem For connection to the data processing server through cellular or user's APN network. Also connect to Schneider Electric's Digital Service Platform. Especially suitable for sites with no internet access. Simply plugs into dedicated port under the front cover. GPRS modem PB112045 GPRS antenna Improves GPRS signal strength in case of poor transmission conditions. Recommended for Com X located inside metallic electrical panels. Zigbee dongle (not shown) For connection to wireless digital enabled field devices such as PowerLogic EM4300 meters. Plugs into USB ports. GPRS antenna PowerLogic WT4200 wireless transmitters, connected to Modbus RS-485, enables collecting data also from water, air, gas or steam meters. 6 PLSED310098EN

Communications Com'X 200/210/510 Setup and configuration PB114857 Installation DIN rail fitting (Front face IP40, terminals IP20). Weight 450 g Dimensions (H x W x D) 91 x 144 x 65.8 mm Setup and configuration Device settings page (partial), as displayed after autodiscovery, enabling user to assign circuit identifications and select data for logging and publication. Connection to LAN As soon as they are connected to the LAN, it can be detected and assigned an IP address by DHCP. Your operating system's DPWS feature allows your computer to automatically recognize the device as Com'X. Embedded web pages are then immediately accessible by clicking each Com X device icon or by typing the assigned IP address into your web browser. Field device auto-discovery The user-activated device discovery function automatically identifies all field devices connected to Modbus SL, Ethernet port or Zigbee dongle. Known Schneider Electric devices display with the product image. Other devices appear as unknown, allowing the user to manually assign a device type. User can assign their own device types. Users can complete additional device identification fields, such as circuit ID or building zone. Custom Library available for unknown field devices Ability to create your own custom model based upon Modbus RTU/TCP, Pulse, sensor, etc. Log data from the custom model Export / Import the custom model into other Com'X devices. Data selection for logging and publication Web page configuration tabs allow you to configure, in just a few clicks, which connected field devices collect and publish data. Advanced diagnostics and troubleshooting features Modbus serial and TCP/IP device statistics. Ethernet network statistics. Communications check wizard. Direct reading of register values from local and remote devices. Additional features and benefits Cybersecurity - works well with your cybersecurity architecture. 2 Ethernet ports to separate upstream cloud connection, or to daisy chain with other Ethernet devices, from field device network. Data storage in case of communications failure. Local backup of configuration parameters - back up your system to a USB storage device and have it available for system restore or to duplicate the configuration on another box. When associated with Schneider Electric Services: Remotely managed (configuration backup, troubleshooting, parameter setting). GPRS SIM contract management (with EBXA-GPRS-SIM). PLSED310098EN 7

Communications Com'X 200/210/510 Specifications Com'X 200/210/510 Environment Operating temperature -25 ºC to 60 C Com'X 200-25 ºC to 70 C Com'X 210/510 Storage temperature -40 ºC to 85 C GPRS dongle -20 ºC to 60 C Operating temperature GPRS dongle -40 ºC to 85 C Storage temperature Wif-Fi dongle 0 ºC to 50 C Operating temperature Wi-Fi dongle -20 ºC to 80 C Storage temperature Humidity 5 % to 95 % relative humidity (without condensation) at 55 ºC Pollution Class III Safety standards / regulation International (CB scheme) IEC 60950 USA UL 508 USA UL 60950 (Com'X 210 and Com'X 510 only) Canada cul 60950 (Com'X 210 and Com'X 510 only) Canada culus 508 Europe EN 60950 Quality Brands CE, UL Power Supply Com'X 200 Com'X 210 Com'X 510 AC 100 to 230 V (+/- 15 %) (50-60 Hz) b DC 24 V (+/- 10 %) b b b Power over Ethernet 15.4 W DC b b b Max power 26 W max b b b Mechanical IP Front face IP40, terminals IP20 b b b Dimensions (HxWxD) 91 x 144 x 65.8 mm b b b Weight 450 g b b b 8 PLSED310098EN

Schneider Electric Industries SAS 35, Rue Joseph Monier, CS 30323 F - 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com Com'X 200/210/510 PLSED310098EN As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document. Design: Schneider Electric Photos: Schneider Electric Over 75 % of Schneider Electric products have been awarded the Green Premium ecolabel 2016 - Schneider Electric - All rights reserved 04-2016