For Sales and Support call KMParts.com (866)

Similar documents
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

15, 6" panel PC with capacitive multi-touch (PCT), 2xEthernet, 2xUSB3.0, 1xRS232, 1xRS485, Galileo Runtime License

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

1492-SP Supplementary Protectors

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

IEC An introduction. 28 March 2012 By Craig McKee Technical Manager

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Disconnect Switches. Safe Switching and Disconnecting

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors. Contents

UL 489 DIN rail branch circuit breakers

Supplementary Circuit Protectors Type GSB63

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Miniature Circuit Breakers for Railway Applications

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Jtec 10kA Miniature Circuit Breaker

60103 Circuit Breaker

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Mini feed-through terminal block - MSDBV 2,5-M

Combined RCD/MCB Devices FRBmM, 1+N-pole

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1B004TLH cam switch - 1 pole A - screw mounting

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

K1D012ULH cam changeover switch - 2-pole A - screw mounting

140M C 2 E A63 KN CC GJ

Cat. No. 140M-F M-D8E-B

Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame

140M C 2 N A63 KN CC GJ

Applying branch circuit breakers and supplementary protectors in North America

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

TeSys protection components

Installation / Control Technique

Selection Guide. Control Circuit and Load Protection

CS8 Industrial Control Relays

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Product Guide. UL 489 DIN rail miniature circuit breakers

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

K1F006ALH cam switch - 6-pole A - screw mounting

Applying branch circuit breakers and supplementary protectors in North America

Miniature Circuit-Breaker IEC Series 8562

TeSys IEC Contactors and Overload Relays

D-Series. Circuit Breaker

Solid-State Contactors

9926 Series Branch Rated Circuit Breakers AC Version

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Allen-Bradley 1492-RCDA4A40

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Section 4 Ground-Fault Protection Devices

Motor protection circuit breakers

Selection Guide. Control Circuit and Load Protection

Datasheet - SLB 200-C04-1R

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RiLine Compact The smart power distribution system

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Protection Equipment

Control Circuit and Load Protection Products

WEG Contactors - CWM and CWME Series

Datasheet - SRB 402EM-24V

Introduction Circuit Protection

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

Datasheet - SRB 301LC/B-24V

Add-on Residual Current Protection PBSM MW

Datasheet - RSS 36-D-R-ST

Bulletin 1489 Circuit Breakers. Selection Guide

Solid-State Switching Devices

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Thermal-Magnetic Circuit Breaker 4220-T...

Solid-State Switching Devices

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

Datasheet SRB301ST 24V (V.2)

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Contact protection relay

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Transcription:

Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping characteristic B Application Switchgear for industrial and advanced commercial applications Rated current I n A 5 Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Product range FAZ Technicaldata Electrical Standards IEC/EN 60947-2 IEC/EN 60898 Rated operational voltage U e V U e V AC 230/400 V DC 48 (per pole) Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Operational switching capacity ka 7.5 Characteristic B, C, D Max. back-up fuse A gl/gg 125 Selectivity Class 3 Lifespan Operations > 10000 Direction of incoming supply as required Mechanical Standard front dimension mm 45 Enclosure height mm 80 Terminal protection Finger and back-of-hand proof to BGV A2 Mounting width per pole mm 17.5 Mounting IEC/EN 60715 top-hat rail Degree of Protection IP20, IP40 (when fitted) Terminals top and bottom Twin-purpose terminals Terminal capacities mm 2 mm 2 1 x 25 mm 2 2 x 10 Thickness of busbar material mm 0.8 2 Mounting position As required DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 5 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 1.9 Static heat dissipation, non-current-dependent P vs W 0 10/31/2016 278528 - HPL-ED2016 V26.0 EN 1 / 8

Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -40 Operating ambient temperature max. C 75 linear, per +1 C, results in a 0.5% reduction of current carrying capacity IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01 [AAB905011]) Release characteristic B Number of poles (total) 1 Number of protected poles 1 Nominal rated current A 5 Nominal rated voltage V 230 Rated short-circuit breaking capacity Icn EN 60898 at 230 V ka 10 Rated short-circuit breaking capacity Icn EN 60898 at 400 V ka 10 Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V ka 15 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V ka 15 Voltage type AC Current limiting class 3 Frequency Hz 50-60 Concurrently switching N-neutral No Suitable for flush-mounted installation No Over voltage category 3 Pollution degree 2 Width in number of modular spacings 1 Built-in depth mm 70.5 Additional equipment possible Yes Degree of protection (IP) IP20 10/31/2016 278528 - HPL-ED2016 V26.0 EN 2 / 8

Approvals Product Standards IEC/EN 60947-2; IEC/EN 60898; UL 1077; CSA-C22.2 No. 235; CE marking UL File No. E177451 UL Category Control No. QVNU2, QVNU8 CSA File No. 204453 CSA Class No. 3215-30 North America Certification UL recognized, CSA certified Conditions of Acceptability Supplementary Protector only Suitable for Branch Circuits; not as BCPD Current Limiting Circuit-Breaker No Max. Voltage Rating 277 VAC; 48 VDC Degree of Protection IEC: IP20; UL/CSA Type: - Characteristics 10/31/2016 278528 - HPL-ED2016 V26.0 EN 3 / 8

Let-through energy I 2 t According to IEC/EN 60898 10/31/2016 278528 - HPL-ED2016 V26.0 EN 4 / 8

Let-through current î D According to IEC/EN 60898 10/31/2016 278528 - HPL-ED2016 V26.0 EN 5 / 8

10/31/2016 278528 - HPL-ED2016 V26.0 EN 6 / 8

Tripping characteristic at 30 C: B, C, D to IEC/EN 60898 10/31/2016 278528 - HPL-ED2016 V26.0 EN 7 / 8

Dimensions Additionalproductinformation(links) AWA1220-1755Circiut-breaker AWA1220-1755 Circiut-breaker ftp://ftp.moeller.net/documentation/awa_instructions/17550701.pdf 10/31/2016 Eaton Industries GmbH http://www.eaton.eu 10/2016 by Eaton Industries GmbH 278528 - HPL-ED2016 V26.0 EN 8 / 8