Owner s Manual Automatic Voltage Switch

Similar documents
Owner s Manual. USB 3.1 Gen 1 USB-C to DisplayPort Adapter with Charging. Model: U444-06N-DP-C

Owner s Manual. USB 3.1 Gen 1 USB-C to VGA Adapter

Quick Start Guide. KVM Extender USB

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station, Aluminum. Model: U442-DOCK10-S

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with PD Charging. Models: U444-06N-H4K6WC, U444-06N-H4K6BC

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

Quick Start Guide. Mini Bluetooth 4.0 (Class 1) USB Adapter. Model: U BT4

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Owner s Manual. HDMI to VGA + Audio Splitter 2-Port. Model: P131-06N-2VA-U

Owner s Manual. USB Type-C to HDMI, VGA, Gigabit Ethernet and USB-A Hub Adapter. Models: U444-06N-HV4GU (White), U444-06N-HV4GUB (Black)

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with Ethernet and PD Charging. Model: U444-T6N-H4GUBC

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station. Models: U442-DOCK1, U442-DOCK1-B

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapters

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Owner s Manual. USB to RJ45 Cisco Rollover Cable. Model: U RJ45-X PROTECT YOUR INVESTMENT!

Quick Start Guide. USB 2.0 Portable Laptop Crash Cart KVM Adapter Model: B032-VU1

Owner s Manual. USB 3.1 Gen 1 (5 Gbps) to CFast 2.0 Card Reader with SATA III Adapter and Built-in Cable

Quick Start Guide. USB 3.1 Gen 1 to DVI Alternate Mode Adapter. Models: U444-06N-DVI-AM (White), U444-06N-DVIBAM (Black)

Quick Start Guide. USB 3.1 Gen 1 to HDMI Alternate Mode Adapter. Models: U444-06N-HD-AM, U444-06N-HDB-AM

Owner s Manual. DVI Single Link with Audio Splitter. Models: B A and B A

Quick Start Guide. USB 3.1 Gen 1 to DisplayPort Alternate Mode Adapter White. Model: U444-06N-DP-AM, U444-06N-DP-RA (Right Angle)

Owner s Manual. 1-Port Gigabit Ethernet (GbE) PCI Express (PCIe) Card

DisplayPort Multi-Display Splitter/Expanders. Models: B , B DVI, B HDMI

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

Owner s Manual. 5200mAh Mobile Power Bank

Owner s Manual. 2-Port DB9 RS-232 Serial PCI Card

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Owner s Manual. USB to Serial Adapter. Model: U DB25 PROTECT YOUR INVESTMENT!

Owner s Manual. USB Type-C to Serial Adapter Cable. Model: U C. * USB Type-C and USB-C are trademarks of USB Implementers Forum

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

Owner s Manual. USB 3.1 Gen 1 USB-C to HDMI Adapter

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Owner s Manual. VGA Over Cat5 Extender Kits with EDID Copy 2 Local, 2 Remote. Models: B and B A

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station - Silver. Model: U442-DOCK4-S. USB Type-C and USB-C are trademarks of USB Implementers Forum.

Owner s Manual. HDMI over Cat5 Extenders and Extender/Splitters

Owner s Manual. 4-Port RS-232 Serial PCIe Card with Breakout Cable

Owner s Manual. Media Converters

Owner s Manual 2-Port USB to Serial Adapter Cable

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

Owner s Manual. USB Peripheral Sharing Switch

Owner s Manual HDMI Matrix Switch

Owner s Manual. DVI USB KVM Switch with Audio. Models: B004-DUA2-K-R, B004-DUA4-K-R

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

Owner s Manual Dual Vertical Flat Screen Desk or Clamp Mount

Owner s Manual. DisplayPort KVM Switch with Audio and SuperSpeed USB 3.0 Hub. Models: B004-DPUA2-K, B004-DPUA4-K

USB 3.0 to DisplayPort Adapter. Model #: U DP. USB 3.0 to DVI Adapter. Model #: U R. USB 3.0 to HDMI Adapter. Model #: U HDMI-R

Owner s Manual. USB 3.1 Gen 2 (10 Gbps) to Dual SATA Dock/Cloning Station. Model: U CG2. Este manual esta disponible en español en la página de

Owner s Manual. USB 3.0 Docking Station for Microsoft Surface. Models: U342-GU3, U342-HGU3 PROTECT YOUR INVESTMENT!

Quick Start Guide. NetDirector Console KVM Switch (8- or 16-Port) or Rackmount KVM Switch (8-Port)

Broadband Automatic Disconnect Switch. User Manual

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC)

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

Owner s Manual. SNMP/Web Management Accessory Card. Model: WEBCARDLX

USB to VGA/DVI Adapter. Model #: U R. USB to VGA Adapter. Model #: U VGA-R. USB to HDMI Adapter. Model #: U HDMI-R

Owner s Manual. USB 2.0 to VGA Adapter

Owner s Manual. DisplayPort / Mini DisplayPort v1.2 Multi-Stream Transport Hubs

Owner s Manual. USB 3.0 Mini Dock

Owner s Manual USB 3.1 Gen 1 (5 Gbps) Display Adapters

Owner s Manual. Media Converters Models: N SC & N ST

VGA Over Cat5 Extender with Audio

NetDirector Console KVM Switch (8- or 16-Port) or Rackmount KVM Switch (16-Port)

Owner s Manual. Gigabit Fiber to Ethernet Media Converters with PoE

Owner s Manual. HDBaseT HDMI Over Cat5/Cat6 Extenders

Quick Start Guide. Console Servers

Quick Start Guide. NetCommander IP Cat5 Multi-User KVM Switch

Owner s Manual. DVI/USB + Audio & Peripheral Sharing KVM Switch

Owner s Manual. Audio/Video with RS-232 and IR Control over IP Extenders

AC4G-D User s Manual

Owner s Manual. Secure KVM Switches, NIAP Protection Profile Version 3.0

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Rack Power Distribution Unit AP7530, AP7540

Owner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications

Zonit μats TM Users Guide μats1-lv Version 1.2

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

PSA200 User s Manual

User's Guide. MiniTec TM Series Model MN25 MultiMeter

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Wall. No opening (Example: LA-030-W)

MPF-1, Mains Power Filter User Manual

iconverter 2-Module Power Chassis

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Keyspan RF Remote for PCs & Laptops

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Progressive Industries, Inc. EMS Electrical Management System

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Quick Start Guide. NetCommander IP Cat5 KVM Switch. Model: B IP2. (Series Number: AG-00C3) Legal Notice Product Overview 2

User Manual Back-UPS BE650MC

Chore-Tronics Mobile Server

Owner s Manual. 4-Port HDMI/USB KVM Switch with Audio and Peripheral Sharing. Model: B004-HUA4-K

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

Installation Instructions

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

SNMP/Web Management Accessory Card Model: SNMPWEBCARD

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

USB 3.0 Spectra

FNet Repeater Installation & Operator s Instruction Manual

Owner s Instruction Manual

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

Transcription:

Owner s Manual Automatic Voltage Switch Model: AVS30D Introduction The AVS30D Automatic Voltage Switch is a 30 amp rated automatic voltage switch that protects appliances from high voltages, low voltages (including brownouts), power surges, spikes and lighting. It does this by switching off connected equipment if the power flowing to it goes outside preset limits, and will reconnect automatically when power returns to normal (except in the case of an overload condition). There will be a delay before the reconnection to ensure power stability. Ce manuel est disponible en français sur le site Web de Tripp Lite : www.tripplite.com Русскоязычная версия настоящего руководства представлена на веб-сайте компании Tripp Lite по адресу: www.tripplite.com 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright 2014 Tripp Lite. All rights reserved. 1 14-01-250-933301.indd 1 3/13/2014 12:18:36 PM

Product Overview 8 6 5 3 4 7 1 2 7 1 2 3 4 5 6 Input Terminal Connects mains power. Output Terminal Connects to appliance wiring. F1 & F2 Program Buttons Using the two buttons, you can set the output over/under voltage, overload protection value, browse settable parameters and change digital display mode. During normal operation, you can press F2 to display the load. After 3 seconds, the switch returns to the voltage display. Voltage LED Illuminates when the digital display shows voltage. Load LED Illuminates when the digital display shows the load in watts. 2 14-01-250-933301.indd 2

Product Overview 7 8 Cord Strain Reliefs Reduces strain on mains and appliance cables. Digital Display Shows voltage, wattage, status and settings. A) U-H Output Overvoltage Protection Status When output voltage exceeds the preset limit and doesn t return to within the preset limits after 1 second, your equipment will be disconnected by the switch. U-H will flash on the display every.5 seconds as long as the overvoltage condition exists. B) U-L Output Undervoltage Protection Status When output voltage goes lower than the preset limit and doesn t return to within the preset limits after 1 second, your equipment will be disconnected by the switch. U-L will flash on the display every.5 seconds as long as the undervoltage condition exists. C) P-H Overload Protection Status When the load exceeds the preset range (nominally 110-120%) and lasts longer than 6 seconds (within this 6 seconds no action will be taken by the AVS30D), the switch will disconnect from power. P-H will flash on the display every.5 seconds as long as the overload condition exists. When the load exceeds the preset range (nominally 150%) and lasts longer than 1 second, the switch will disconnect from power. P-H will flash on the display every.5 seconds as long as the overload condition exists. D) Start Up Delay When first powered up, the unit will count down a set number of seconds (default is 6) before monitoring voltage. E) Parameter Setting Codes E-0 Delay setting E-1 Undervoltage protection value setting E-2 Overvoltage protection value setting E-3 Overload protection value setting E-4 Displays output voltage or loading power value after startup (U= voltage, P= watts) E-5 Restores default settings Note: The code and value flash alternately every second while changing settings. 3 14-01-250-933301.indd 3

Operation Caution: Don t use this switch with any device that needs to be continually powered, as the switch is designed to cut power when unstable voltages occur. 1) Make sure your load doesn t exceed the 30 amp rating of the switch. 2) The switch must be wired to the mains supply and the equipment it s supplying. Please refer to Connection section for wiring and installation instructions. 3) After the switch is plugged in, it will display a 6 second countdown (default) before supplying power to your appliance and showing the voltage on the Digital Display. 4) If the default settings aren t appropriate for your situation, you can change them by following the procedure in the Changing Settings section. Notes: We strongly recommend you use the default settings to ensure safe operation of the switch. It s possible to adjust the parameters at any time. Changing the delay setting requires a power cycle for the new delay to take effect. Resetting an Overload Fault The unit doesn t reset automatically from an overload fault. To manually reset the unit: 1) Remove the cause of the overload. 2) Press and hold F1 until E-0 appears on the display, then release. 3) Wait for the unit to reset. It will count down from preset and turn the load back on. 4 14-01-250-933301.indd 4

Changing Settings Press and hold F1 for three seconds to enter settings mode. Setting Codes: E-0 will be displayed. (See Switch Settings chart for code explanations) Press F1 to cycle through the available codes. Press F2 to select the code you wish to change. Press F2 to adjust the value (the code and value will flash alternately every second). Each value changes by a certain increment every time you press F2 (See Switch Settings chart). Press F1 to confirm the value. Don t press anything for 10 seconds to exit and save the settings. Switch Settings Code Item Default E-0 E-1 E-2 E-3 E-4 E-5 Settable Range Delay Setting 6 seconds 6-120 seconds Undervoltage Protection Overvoltage Protection Overload Protection Digital Display Restore Defaults Increment # of Increments 6 seconds 20 180V 120V-200V 5V 16 255V 210V-270V 5V 12 3000W 800W-4800W 800W 6 Shows output voltage or loading power value after startup (U= voltage, P= watts) Restores all default settings. Unit will display defaults once confirmed, then reset and count down. Note: An A on the display indicates the load exceeds 1000 watts (e.g. 2A5 =2500W) 5 14-01-250-933301.indd 5

Connection DANGER! RISK OF ELECTRIC SHOCK! All wiring should be performed by a qualified electrician in accordance with all applicable electrical and safety codes. All wiring must comply with local ordinances and must be a proper type and size to support 30 amps. Incorrect wiring may damage the switch severely and cause serious personal injury and property damage. Connection Warnings The user must determine if this device is suitable for the intended application. The device should be installed indoors only. This device is not intended to serve as overcurrent protection. Overcurrent protection should be provided by the user and present on the input side of the device. Verify that the input source is not live when wiring this device. Once installed, never operate the device without the cover in place. Wiring 1) To get access to the connection terminals, you need to remove the bottom cover. To do this, remove the two black caps and then remove the two screws. Remove the bottom cover. 2) Loosen the cord strain reliefs. 3) Insert cable from the mains supply through the left side input cable port and make the screw terminal connections (refer to the Connection Terminals diagram). DO NOT OVERTIGHTEN SCREW TERMINALS. 4) Insert appliance cable through the right side output cable port and make the screw terminal connections (refer to the Connection Terminals diagram). 5) Tighten the cord strain reliefs, then replace the bottom cover, screws and caps. Note: Mount the switch to a screw on the wall by using the keyhole slot on the back. Connection Terminals INPUT Line to IN:L Neutral to IN:N Earth to E 6 OUTPUT Line to O:L Neutral to O:N Earth to E 14-01-250-933301.indd 6

Specifications Current Rating 30 amps Voltage Rating 230V (220-240V) Frequency 50/60 Hz Response Time Over/undervoltage 1 second Reflex Voltage Over/undervoltage 5~10V Radio Frequency Interference/Noise Protection Yes Spike/Surge Protection (Joules) 380J Spike/Surge Protection (Amps) 6500KA (8/20us) Spike/Surge Protection (Response Time) 10 nanoseconds Dimensions (HxWxD) 205x135x55 mm Weight.5 kg 7 14-01-250-933301.indd 7

Warranty 7-Year Limited Warranty TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of seven (7) years from the date of initial purchase. TRIPP LITE s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty, you must obtain a Returned Material Authorization (RMA) number from TRIPP LITE or an authorized TRIPP LITE service center. Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment, which has been damaged by accident, negligence or misapplication or has been altered or modified in any way. EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marketing name or model number of the product. WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union) Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to: Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country) Send the new equipment back for recycling when this ultimately becomes waste Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. Tripp Lite follows a policy of continuous improvement. Product specifications are subject to change without notice. 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support 8 14-01-250-933301.indd 8 3/13/2014 12:18:38 PM