MODEL NM42U NMEA 0183 USB Multiplexer

Similar documents
MiniPlex-41 NMEA-0184 multiplexer Manual

MiniPlex-41USB NMEA-0183 multiplexer Manual

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005

User Manual For software version 1.00

Getting started with your DGH module:

NM-251D-INC. Dual Axis Inclinometer Output Format converter User Guide V1.00. Introduction

Model RS11 v2.0 CANbus Engine Data Converter NoLand Engineering, Inc. 1. Introduction

NM-251D-DTM. Datum Generator - Data Multiplier User Guide V1.00

NMEA 0183 Multiplexer User s Manual

Trouble shooting the DeskCNC controller:

9103 Picoammeter User Guide

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

MiniPlex-41BT NMEA-0183 multiplexer Manual

NMEA 0183 Multiplexer User s Manual

education and advancement of the marine electronics industry and to waypoint, present Lat/Long, and a binary status byte.

DFS/Cutter. Debugging Communication Problems

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

ICP PANEL-TEC PEX3000 II

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

CLM-602 CAMERA LINK MULTIPLEXER. User s Manual. Document # , Rev 0.1, 2/17/2014 (preliminary)

NMEA Buffer NBF-2-A. User Manual

EGW1-IA3-MB User s Manual

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Evaluation Board for ELM4 / LSM4. Technical Reference Manual

1. Introduction Features Specifications System Requirements of PC Package Software Installation

EMX-AMP / EMX-I-AMP 4K HDMI Audio Extractor with Power Amplifier. GUI User s Manual CUSTOMER SUPPORT INFORMATION

USB485 USB to RS485 Converter Card

The ICP 300 is an ultra-compact, lightweight portable thermal printer with an easy-load paper feature.

Getting Started with your D3000M Series Module

QK-A031 NMEA 0183 Multiplexer with SeaTalk Converter Features

Updating Reader Firmware

Altair RU. Owner s Manual. Document name: AtrRU-EN Document version: 0.3 Release date: 25/03/2009

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Quick Network Block QNB-1-B. User Manual

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with a Trimble NetRS GPS Receiver

1. Main Features. TCIC User s Manual

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

Silverpak 17C/CE INTEGRATED STEP MOTOR, DRIVER AND CONTROLLER

OPERATING MANUAL AND TECHNICAL REFERENCE

NBF-3. User Manual. NMEA 0183 Buffer. For all variants: NBF-3-BAS, Rev A. Issue 1.01

ECV ecompass Series. Technical Brief. Rev A. Page 1 of 8. Making Sense out of Motion

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

NMEA Data Combiner NDC-3-B. User Manual

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

SeriBox. antrax Datentechnik GmbH

Brookhouse emux, the NMEA 0183 Ethernet TCP/IP server Installation instructions

BM1001 & BM2001 Serial & USB Adaptor

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

The JT-DO1 GPS-disciplined IRIG-B timecode generator produces timecode according to the IRIG-

PWRcheck Spring City Drive Waukesha, WI

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

3 Input Multiplexer Operation Manual

Flex Series User Guide

Moog Components Group Submux1 Manual December 7, 2009

NMEA Data Combiner NDC-3-B-USB. User Manual

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

BOARD LEVEL PRODUCTS OEM GPIB<->RS-232 INTERFACE BOARD GPIB

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc.

Multi-Port Controller

EX-HDU HDMI, AUDIO & USB EXTENSION

mbc082 Bus Converter

NMEA Data Multiplexer NDC-4 For all variants: NDC-4, NDC-4-USB, NDC-4-ASW NDC-4-AIS, NDC-4-AIS-USB. Install User Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

BNI USB A501. USB IO-Link Master User's Guide. english

A2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USP-S24 & USP-S48. Multi-purpose Web-browser Configurable 24 and 48 Pushbutton Switch Panels. USP-S24 and USP-S48 RELIABILITY

Interfacing BU-70 Display Units and BU-100/BU-101 Panels

RS485 MODBUS Module 8I8O

Blue Point Engineering

Wireless Receiver W/ USB Output BA/RCVxxx-USB Installation and Operating Instructions

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

I/O SIGNAL CONDITIONER

Bluetooth RS232 Serial Adapter

Allen-Bradley 1397 L11 I/O Expansion Card

Installation & Operation

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

User Manual A08. User Manual

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

7561-PSD Manual Portable Battery Powered Indicator

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

SEI-USB. SEI to USB Adapter Page 1 of 5. Description. Features

E600 VX01 Installation guide

EMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20

115S Serial I/O Module User Manual

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DC BRUSHLESS MOTOR CONTROLLER BLSD-20/BLSD-50

MEV Limited USB232/485 INSTRUCTION MANUAL

Transcription:

MANUAL MODEL NM42U NMEA 0183 USB Multiplexer This manual covers version 3.1. Future versions of this product may contain enhancements not covered here. TABLE OF CONTENTS 1. General Description 2. Installation Power and Ground Connection NMEA 0183 Inputs and Output NMEA 0183 Talker Connection Baud Terminal USB Connector Typical Installation Software Installation Windows 98,ME,NT,2000,XP 3. Operation Status LED Data Acquisition 4. Troubleshooting Testing with Status LED 5. Technical Specifications 6. Warranty

TABLES Table 1 - Interface Description Table 2 - LED Status Meanings Table 3 - Single Error Codes Table 4 - Multiple Error Codes Table 5 - Multiple Error Codes incl. TLK & ovfl FIGURES Figure 1 - NM42U Connections Figure 2 - Typical Installation with USB connected Figure 3 Typical Installation without USB Figure 4 Outline Drawing Programming Instructions APPENDIX A 1. General Description The NM42U USB Multiplexer combines up to four NMEA 0183 instruments (talkers) into a common NMEA 0183 output. This output would normally go to another NMEA listener such as a radar, chartplotter, or repeater. The USB connector provides a computer interface. The computer will receive all of the combined data from the instruments and can also send data back to the instruments, which will appear, at the TLK port of the NM42U. This can be used for downloading waypoints, requesting specific types of data, sending steering commands, and more. Installation and operation of the NM42U is simple. All connections to instruments are made via a terminal strip. The unit begins operating as soon as power is applied. No initialization or setup is required. The USB connector provides 2-way data communication to/from the computer. The NM42U may be operated either with or without a USB connection. Some configuration options are user programmable. (See Appendix A.) To assist in installation and troubleshooting, a multicolor LED is located on top of the NM42U. The LED will flicker green when valid NMEA sentences are being received on any of the four inputs. The LED flickers red when valid NMEA sentences are received from the USB interface. It will show a yellow color for about ½ second if an error is detected and simultaneously send an error identification sentence to the outputs (OUT+/OUT and USB). 2. Installation Installation of the NM42U requires connection to a power source and to NMEA talkers and listeners. All connections are made via a fifteen position terminal strip. A description of the connections is given in Table 1. Any unused connections open may be left disconnected. A USB connector is provided on the rear for connection to a computer. D.C. power to operate the NM42U must be supplied to the terminal strip. It does not come from the USB connection.

Table 1. Interface Description PWR, GND Baud OUT+, OUT- TLK+, TLK- IN1.. 4+, IN1.. 4- USB Conn. Ships power (8-28VDC), 50 ma. typical current draw. Baud rate select terminal. Ground this terminal for HIGH baud. Leave open for 4800 baud (default). Combined output (RS-422) from the 4 NMEA 0183 inputs. 4800 38,400 baud (selectable). Talker output (RS-422) from computer to listeners such as GPS, autopilot, etc. 4800 baud only. Listener inputs (opto-isolator) from instruments. IN1, 2 = 4800 or 9600 baud. IN3, 4 = 4800 baud only. USB interface to computer. A small amount of D.C. current (< 10 ma.) required from host. Power/Ground Connection The power (PWR) and ground (GND) connections are located at one end of the terminal strip. The power source can be anywhere in the 8-28 Vdc range. D.C. power must be supplied to this terminal even if USB power is present. There is no ON/OFF switch on the NM42U due to its low power consumption. NMEA 0183 Inputs and Output The four NM42U input connections are labeled IN1 through IN4, and the output is labeled OUT. When connecting instruments to these inputs, it is important to maintain the proper polarity of the lines. Always connect the + terminal of each talker to the corresponding + or A terminal of each listener. Likewise, connect the - terminal of each talker to the corresponding - or B terminal of each listener. Likewise, connect the - terminal of each talker to the corresponding - or B terminal of each listener. In some cases a device will not have +/- or A/B connections, but rather only a Data in or Data out which is referenced to ground. These are known as single-ended devices. For single-ended talkers, connect the Data out to IN+ connection of the NM42U. The INconnection must be connected to ground or common. For single-ended listeners, connect the

NM42 OUT+ terminal to the Data in. Leave the OUT- terminal open. Never connect OUT- to ground or common. The inputs (IN1-IN4) are configured to operate at 4800 baud. IN1 and IN2 can be reconfigured to operate at 9600 baud. See Appendix A. NMEA 0183 Talker Connection The talker (TLK) port outputs data received from the PC interface (USB). It may be connected to any instrument that is a listener, such as an autopilot or GPS receiver, which requires information from the PC. The TLK output baud rate is fixed at 4800 regardless of the baud rate of the PC interface. This port is also differential (RS-422) and follows the same convention as with the OUT+/OUT output. The TLK terminal should never be connected to ground or common. It can be left disconnected where necessary. Multiple listeners may be connected to this port within the loading limitations of the device (50 ma. max.) The TLK output data rate is always fixed at 4800 baud even if the baud terminal is set to HIGH (grounded). Multiple listeners may be connected to this port within the loading limitations of the device (50 ma. max.). The TLK output data rate is always fixed at 4800 baud even if the baud terminal is set to HIGH (grounded). Baud Terminal This connection is used to increase the output data rate, which increases the data throughput of the NM42U. With the terminal disconnected, the data rate is set at 4800 baud, the standard for NMEA 0183. Connecting baud to ground causes the output (OUT+/OUT-) data rate to change to the HIGH value. Normally the HIGH baud rate will be 9600 (factory preset) if the unit has not been reconfigured. To reconfigure the HIGH baud for 19,200 or 38,400 see Appendix A. The NMEA inputs and the TLK output will remain at 4800 baud even with baud grounded. The baud rate detection only takes effect at power-up. Any change to this terminal must be followed by a reset command or by power removal and restoration for the change to take effect. USB Connector The USB connector located on the rear of the NM42U provides a computer interface. The use of the USB interface requires software drivers be installed on the computer to which it is connected. These drivers convert the USB connection into a Virtual Com Power so that software expecting a serial COM_ port can send and receive data. A small of D.C. current (< 10 ma.) is drawn from the USB connection when connected. Typical Installation A typical NM42U installation with a computer connected to the USB interface would resemble Figure 2. A computer is present to collect all the data from onboard instruments and also to send steering commands to an autopilot and send waypoints to the GPS. The GPS provides position information while the autopilot provides heading. Any other instruments, such as a chartplotter, may obtain the combined instrument data from the OUT+ / OUT- terminals. The NM42U can also be used without the USB connection. In this case, D.C. power must be applied to the +12V terminal on the front of the unit. An optional computer with a COM Port can be connected to the OUT+ terminal as shown to receive the combined NMEA 0183 data. Figure 3 shows the connection.

Software Installation This section describes how to install the USB Serial Port drivers and Virtual COM Port drivers. Updates to these procedures may be found on the NoLand Engineering NM42U Drivers Disk. Windows 98,ME,NT,2000,XP 1) Plug NM42U into USB port of computer 2) Insert NoLand Engineering NM42U Drivers Disk into disk drive of computer

3) When the New Hardware Wizard window appears, select the Windows recommended option 4) Click Next 5) Click Finish If your computer does not automatically install the USB Port Drivers, a New Hardware Wizard will appear. In this case: 1) When the New Hardware Wizard window appears, select the Windows recommended option 2) Click Next 3) Click Finish Software driver installation is complete. To determine which COM port number was assigned to the USB serial port, look under Windows Device Manager, double click ports (COM and LPT), and look for USB Serial (COM #). If any problems occur, please reference the Readme.txt file on the installation disk. 3. Operation NOTE: The NM42U can be operated with or without the USB connection. See Installation for more details. Once the NM42U is installed and a computer is connected to the USB interface, the unit begins acquiring data automatically. The combined data rate will be 4800 baud (~480 characters/second). To change this to the HIGH baud rate, ground the baud terminal, remove D.C. power (or USB connection) and reapply power to reset the NM42U. The baud terminal is only checked at initialization, so any change will not take affect until a reset is issued or the D.C. power is removed and restored. Status LED A multicolor LED is situated in a recess on top of the NM42U. The colors and their meaning are summarized in Table 2. The LED will only show one color at a time as determined by its priority. The yellow color has highest priority to indicate an error has occurred. The red color has next highest priority and will be seen if no error is currently present and data is being sent to the TLK output. The green LED will only be lit if either of the other colors is not displayed. The green and red LED colors flicker as data is being sent. The yellow color is for error notification and remains lit for approximately ½ second. This makes it easier to discriminate from the red color. Table 2. LED Status Meanings Color/State Priority Meaning Yellow Steady ~ 1/2 sec Red Flickering Green Flickering highest middle lowest An error has occurred, and an error identification sentence is being sent. A valid sentence from the USB interface is being sent to the TLK output. A valid sentence from one of the four inputs is being sent to the outputs. Whenever the yellow LED is displayed, an error message is sent to both the NMEA output

(OUT+/OUT-) and the USB interface. Refer to Troubleshooting (Section 4) for more information about the error messages. Data Acquisition Acquiring data from marine navigational instruments is the primary function of the NM42U. Under the NMEA 0183 Standard, all data is transmitted as ASCII characters assembled into specific sentences. The format of every sentence is defined in the Standard. Every sentence begins with a dollar sign ($) and ends with a carriage return and linefeed, (<CR><LF>). Immediately following the $ is a five character identifier which defines the type of instrument and the specific sentence being sent. Following the identifier are data fields separated by commas. The easiest way to view the data is with a terminal program such as Hyperterminal available on most PC s. The following settings are used to view NMEA 0183 data: Baud Rate 4800 Data Bits 8 Parity none Stop Bits 1 Flow Control none NMEA 0183 devices may be either talkers or listeners or both. Data is typically sent once each second. 4. Troubleshooting A useful feature of the NM42U is the detection and reporting of errors. There are five types of errors, which can be detected, in any of the five internal channels (4 inputs + talker). An error message identifies both the channels and types of errors that have occurred. It is available at both the USB interface and the OUT+/OUT- terminals. The error message is sent simultaneously with the error LED (yellow) being displayed. The error message identifies the error channels and types with an alphanumeric code. The format is as follows: $PNOLE, c, t where c represents an alphanumeric code identifying the error channel(s), and t represents an alphanumeric code identifying the error type(s). The codes for a single error and their meaning are presented in Table 3. The error message is sent only once each half second when errors are present. The message will contain a summary of all error channels and types which occurred during the previous interval (~ ½ sec). Table 3. Single Error Codes CODE ERROR CHANNEL ERROR TYPE 1 IN1 sync 2 IN2 char 4 IN3 dolr 8 IN4 lnfd G(16) TLK ovfl

The meaning of the error types is as follows: sync This is a synchronization, or framing, error caused by an invalid START bit or STOP bit, usually from corrupted data. char This is a character error which occurs when an 8-bit ASCII character is detected. dolr This is an error generated when a $ (start of sentence) character is not received when expected. lnfd This is an error generated by a missing linefeed character or a sentence containing too many characters. ovfl This is a buffer overflow error which occurs when more data is coming into the NM42 than it can send out. In most instances only a single channel will have an error, but there may be several errors occurring during the reporting interval. For example, synchronization errors will usually occur simultaneously with character errors and possibly dollar and/or linefeed errors. If an input is connected or disconnected on-the-fly while it is sending data, an error will most likely occur. If an input is reverse polarized, it will generate continuous error messages about twice per second. As an example, the sentence $PNOLE,4,7 indicates that IN3 had sync, char, and dolr errors. We know this because 7 is the sum of 1(sync) + 2(char) + 4(dolr). Each of the five types of errors is assigned a binary power (1, 2, 4, 8, F). The sum of any of these binary powers equals a unique number, which can be decomposed into the simple error types. To accommodate quantities over 9, letters are used to represent the quantities 10(A), 11(B), 12(C), 13(D) and so on. The encoding of the error channel follows this same scheme used for error type. Table 4 provides codes, which represent multiple error types and multiple error channels. The TLK error code and the ovfl error code are not shown in Table 4, because they rarely occur in practice. If a TLK or ovfl error occurs with other errors, Table 5 can be used to decipher the codes. Testing with Status LED The LED provides a convenient means to test the NM42U in place. This is because the NM42U will always produce an output whenever any of the five input channels (4 + talker) is stimulated. If valid data is detected, the LED will flash red or green as appropriate and the data will be sent to the output. Table 4. Multiple Error Codes CODE ERROR CHANNEL(S) ERROR TYPE(S) 3 IN2 + IN1 char + sync 5 IN3 + IN1 dolr + sync

6 IN3 + IN2 dolr + char 7 IN3 + IN2 + IN1 dolr + char + sync 9 IN4 + IN1 lnfd + sync A(10) IN4 + IN2 lnfd + char B(11) IN4 + IN2 + IN1 lnfd + char + sync C(12) IN4 + IN3 lnfd + dolr D(13) IN4 + IN3 + IN1 lnfd + dolr + sync E(14) IN4 + IN3 + IN2 lnfd + dolr + char F(15) IN4 + IN3 + IN2 + IN1 lnfd + dolr + char + sync Table 5. Multiple Error Codes including TLK & ovfl CODE ERROR ERROR TYPE(S) CHANNEL(S) H(17) TLK+IN1 ovfl+sync I(18) TLK+IN2 ovfl+char J(19) TLK+IN2+IN1 ovfl+char+sync K(20) TLK+IN3 ovfl+dolr L(21) TLK+IN3+IN1 ovfl+dolr+sync M(22) TLK+IN3+IN2 ovfl+dolr+char N(23) TLK+IN3+IN2+IN1 ovfl+dolr+char+sync O(24) TLK+IN4 ovfl+lnfd P(25) TLK+IN4+IN1 ovfl+lnfd+sync Q(26) TLK +IN4+IN2 ovfl+lnfd+char R(27) TLK+IN4+IN2+IN1 ovfl+lnfd+sync S(28) TLK+IN4+IN3 ovfl+lnfd+dolr T(29) TLK+IN4+IN3+IN1 ovfl+lnfd+dolr+sync U(30) TLK+IN4+IN3+IN2 ovfl+lnfd+dolr+char V(31) TLK+IN4+IN3+IN2+I ovfl+lnfd+dolr+char+sync N1 If an input has invalid data, the error LED will light and an error sentence will be transmitted identifying the problem. If a computer is connected to the NM42U, the error message can be observed with a terminal program such as Hyperterminal. These tests are simple, requiring no special equipment. Voltmeter testing of differential signals (RS-422) can produce very confusing results and should not be relied upon to determine proper operation of the NM42U. 5. NM42U Technical Specifications Supply Voltage Supply Current Input Drive Voltage Input Impedance Talker Output Output drive (OUT, TLK) 8-28 VDC 50 ma. max 2-14 V (Active State) 1K Ohms (Min.) 4V Differential (RS-422) 50 ma. (max)

Serial Output Baud Rate 4800 38,400 (selectable) Serial Output Formats USB2.0 and RS-422 Size 3.75 x 3.0 x 1.0 Weight 3 oz. 6. Warranty NoLand Engineering, Inc., provides a two-year replacement warranty against manufacturing defects and component faults. Inquiry for warranty replacement may be made directly to NoLand Engineering via phone, fax, or e-mail. Include the model number and serial number of your unit with any inquiry. APPENDIX A Programming Instructions Introduction The NM42U is capable of accepting certain commands and taking appropriate action such as a device reset. The commands are also used to configure various options, such as baud rate selection. All programming is done through the PC (USB) interface. Although programming can be done while the unit is operating, it is much easier to stop data flow while programming is being done. This can be done with the stop device command, or all inputs can simply be disconnected or turned off. With the device connected to a computer, a terminal window (e.g., Hyperterminal) can be used for programming. Commands typed into the terminal window are sent to the NM42U, which will check their validity and take appropriate action. All commands begin with an @ character followed by another character which defines the action to take. Some actions will need additional characters (options) to more specifically define the action. A list of command characters and options is given in Table A-1. Programming Example An example will demonstrate how to program the NM42U. With the device connected to a computer and a terminal window open and configured for the correct COM port, we are ready to send a command. If the device is currently receiving data, we can stop the data flow by typing

@< This causes the data flow to stop. If we now type @? We will get a list of the current configuration options. TABLE A-1 NM42 Command (Factory presets are shown in bold.) Command Action Options Comments < Stop device (n/a) Stop data flow (i.e., for programming) > Reset (restart) device (n/a) Same as power disconnectreconnect? Help / Query configuration (n/a) Shows help / shows current device configuration B or b Set HIGH baud rate 1,2,3 9600, 19200, or 38400 baud available I or i Input baud rate select 1,2, 3,4 IN1 = 4800, 9600 IN2 = 4800, 9600 e or E Error reporting on/off 1,2 3,4 1 Error report on 2 Error report off 3 Max sentence length = 82 4 Max sentence length = 127 Assume you now want to reconfigure the HIGH baud rate for 38400. By typing @B3 the HIGH baud rate will be reconfigured to 38400. It will remain configured this way unless it is reconfigured sometime in the future. To verify the configuration change was accepted, you can again type @? which will show the current configuration. In this particular case, the actual baud rate change does not take effect unless power is removed and reapplied (forced reset) or the reset command (@>) is sent. The @I command is rarely used but is available for certain specialized users. It is used to increase IN1/IN2 baud rates to 9600. The @E command performs two different actions. It turns error reporting on or off and also sets the maximum sentence length. Turning error reporting off does not affect operation of the error (yellow) LED. The normal sentence length limit is 82 characters per the NMEA standards but can be increased to 127 chars when needed by issuing the @E4 command. NoLand Engineering Inc 728 E Lincoln Ave Suite 3 Melbourne, FL 32901 Tel: (321) 951 7329 Fax: (321) 951-8773 http://www.nolandengineering.com email: info@ nolandengineering.com