To Our Valued Customers

Similar documents
CIB 3097 ESD Suppression Kit

Encore XT Manual Gun Upgrade Kit

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

OLPC XO-4 Touch Mouse Buttons Controller Replacement

AP-120 Series AP Mounting Kit

How To Install: C4000 EMV Upgrade Kit

Motorola Atrix 4G Bottom Speaker

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

OLPC XO-4 Touch Touchpad Controller Replacement

Peel/Rewind Upgrade Kit

G12/G12x USER S MANUAL

How to Perform an IBM ThinkPad X60s Fan Spindle Replacement

PC9/P9 CPU Card Replacement

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Upgrading LVDS Cables Instruction Sheet

LumaRail Free Stand Bed Assist Rail with IntelliBrite LED Night Light

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

Motorola Droid X Camera Replacement

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen.

MODE. Welch Allyn 767 SureTemp 4 Thermometer System. Directions For Use

Motorola Cliq LCD Screen Replacement

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Dual Drive Installation

INSIDE-OUTSIDE THERMOMETER WITH MIN/MAX MEMORY USER S MANUAL

0. Silicon Graphics O2 and Silicon Graphics Octane R12000 CPU Upgrade Information

F2A (M527) F2A (M506n/dn) F2A (M506x)

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation

ASSEMBLY INSTRUCTIONS for 16 WAY GT MIXED 150/280 SEALED CONNECTION SYSTEM

imac Intel 20" EMC 2133 and 2210 Optical Drive Data Cable Replacement

Further Information can be found at

imac Intel 27" EMC 2639 Hard Drive

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

Model R2400. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments

imac Intel 21.5" EMC 2428 SSD Dual Drive

Replacement Instructions. Backplane PCA for the HP Router 650

Motorola Atrix 4G Screen Replacement

Replacing a Disk Drive

Royal RVV-500 (B) Retrofit Kit

S E R V I C E N O T E

Motorola Droid X Motherboard Replacement

Written By: Walter Galan

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Mac mini Late 2014 Power Supply Replacement

Reflowing Xbox 360 Motherboard

Removal and Installation8

imac Intel 20" EMC 2133 and 2210 SSD

Snap Server 4400 Power Supply

TDM To MiniMech conversion ProceDure

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

Model ST-610B. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments. www. com

MacBook Pro 13" Unibody Mid 2010 SSD Dual Drive Installation

Written By: senordingdong

MacBook Unibody Model A1278 SSD Dual Drive

Samsung Galaxy Tab Wi-Fi Motherboard

Installation Guide for DV8 Off-Road Tailgate-Mounted Tire Carrier (18-19 Jeep Wrangler JL)

Ribbon Supply Spindle Maintenance Kit

Replacing the SATA PCI Controller Card

Dell Inspiron 1525 Upper Case Replacement

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Written By: Andrew Bookholt

Field-Replaceable Units

OPERATING USER MANUAL for PRESSURE RECORDERS

Assembly Instructions for #5630 Medication PalWOW

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

PDC / ECIS. Display Update update with conversion kit Display Update. Contents. General information. Important notes.

ipad Mini Wi-Fi Front Facing Camera Replacement

Nikon D610 Flash Capacitor Replacement

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 Optical Drive Replacement

Xbox 360 Motherboard Replacement

Nikon D5000 Viewfinder Replacement

64-Ch Windows-based NVR. with 8-Bay Hard Disks NVR-E6480. Quick Installation Guide

Rack Installation Instructions

IBM. Rack Installation Instructions

E2460GS Oscilloscope Upgrade Kit

Apple 3.5 Drive External Floppy Drive

SCXI-1345 Shielded Cable

Written By: Miroslav Djuric

HP C8000 Workstation Disassembly Procedures

Replacing Preamplifier Circuit Boards

UNITY 2 TM. With ULTRA (50:50) & Air Server Series 2. Version 1.2. September 2012

imac Intel 27" Retina 5K Display CPU Replacement

HP TouchPad USB Connector Board Replacement

Sonnet AV/HPV Card Video Adapter Kit

imac Intel 21.5" EMC 2389 Stand Replacement

iphone 6 Plus Front Facing Camera and Sensor Assembly Replacement

Universal Desktop and Monitor Stand

imac Intel 24" EMC 2134 and 2211 Hard Drive

3 1 ROM. Installation Manual

TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

(Hardware and case keys are provided inside the chassis storage compartment.)

Indoor Protected Entrance Terminal 4588 Series

INSTALLATION INSTRUCTIONS

RACKMOUNT CONSOLE KVM SWITCH QUICK INSTALLATION GUIDE

BCM Rls 6.0. Redundancy. Task Based Guide

ipad Mini 2 Wi-Fi Front Panel Assembly Replacement

PlayStation 3 Teardown PS3. Written By: Mint137. ifixit CC BY-NC-SA Page 1 of 22

Written By: Miroslav Djuric

1500SE UPGRADE DOCUMENT

iphone 1st Generation Camera Replacement Written By: irobot ifixit CC BY-NC-SA Page 1 of 11

Transcription:

To Our Valued Customers ADC s Adview Modular Diagnostic Station provides a truly customizable diagnostic medical instrument. With your purchase of an Adview unit that includes a thermometry module, you will also receive a probe well and temperature probe as component parts of this module. Recently, in an effort to provide continued support for the thermometry module included on equipped Adview models, a change has been made to the temperature probe and probe well for Adview devices manufactured after 5/18/15. If you are ordering replacement parts or trying to install them on your Adview diagnostic station, this field guide will provide you with information relating to the component parts and with instructions on properly attaching the new replacement parts and upgrading your older Adview device. This guide is applicable to both new Adview Modular Diagnostic Stations and replacement parts that have been ordered for an older system. Before you start, you should ensure that you have the latest temperature probe well and probe, as these instructions will guide you on the installation and replacement of these components. To help you identify the types of components you have, refer to the images on the following page. You will want to install only new parts on your Adview device, and you should determine whether or not you have an older or newer style probe well and probe before beginning installation. If you have identified that your thermometer probe well and probe are older, we recommend purchasing an entire upgrade kit, item numbers 9000TWBKIT for oral models and 9000TWRKIT for rectal models. It is important to note that the new probe well has two parts, including the well itself and a back piece that attaches to the well once the probe has been connected. All component parts are included in the replacement part kits.

Old Style Parts Temperature Probe Well Probe New Style Parts Temperature Probe Well Probe

It is important to note that there is a distinct difference in the profiles of the older and newer temperature probe wells on the Adview diagnostic modular station. OLD NEW Thermometer module assembly Follow the steps below to assemble your new Adview probe well and temperature probe. The connector of the Temperature Probe is the portion that connects the probe itself to the probe well on the back of the device. The configuration of this probe is one of the primary differences between the new and older style temperature probes and probe wells.

Before you can assemble the temperature probe and the temperature module back cover, you will first need to prepare the back cover to receive the probe s connector. To begin, you will need to remove a small access plate on the rear of the cover. This component slides outwards and can be completely removed as illustrated below. This entire component can be removed to access the connection point for the thermometer probe on the back of the housing. The access plate is pulled out and away from the back cover, and is completely disconnected.

The thermometer probe connector is then threaded through the opening on the access plate that has just been removed. Care should be taken to ensure that the access plate is properly oriented, with the external surface of the plate facing you as the connector is inserted into the plate. The access plate must be oriented as shown to ensure that the temperature probe s connector has been inserted in the proper orientation.

As shown in the image below, the connector has been threaded through the opening of the access plate and is now ready for connection to the back housing of the temperature module. The temperature probe connector has been threaded through the access plate. The connector is then connected to the port on the back of the thermometer module s back housing as shown below. The thermometer connector is inserted into the back of the temperature module housing, connecting it to this component.

It is important to note that the connector is held in place within the housing by a plastic tab that prevents it from coming free. The connector should be inserted until this tab clicks into place as shown below. This tab will lock into place once the connector has been fully inserted. Check the security of the probe s connector before proceeding to the next step. Once the connector is in place, the access plate can be put back in place. This component is connected using small tabs on the underside of the plate that fit into grooves on the back housing of the temperature module. Each of the tabs on the access plate have corresponding slots on the back housing of the module.

The complete assembly will be flush against the back housing of the temperature module and will be secure. Slide the Temperature Module Back Cover onto the Temperature Module Chassis. Use the outside rails to guide the parts into place. The top of the back cover will be flush with the top of the temperature module once the cover is pushed into place.

For systems with a new thermometer module installation, you may need to set the display units to F by pressing the button on the side of the module s body as shown below. Please note that the device must be powered on during this process. The button you must access is recessed into the device and is not the check button for the thermometer module. If the device is already set to Fahrenheit, this step will not be necessary. A tool will be needed to reach the recessed button. The test probe must be inserted into the well in order to change the settings from Fahrenheit to Celsius. Once the steps above have been completed, your Adview temperature module will be fully operational. This guide may be used when installing a new temperature module or when replacing worn or broken parts. For further assistance with your Adview Modular Diagnostic Station, please contact our Customer Service department toll free at 1-800-ADC-2670 or visit us on the web at www.adctoday.com.